Development of miniaturized solid phase microextraction of copper in serum using a micropipette tip in-syringe system combined with micro sampling flame atomic absorption spectrometry

A new miniaturized solid phase microextraction (SPmE) method, using a micropipette tip, packed with carbon cloth, mounted on a syringe, was developed for preconcentration and determination of trace levels of copper in serum samples of male adolescents having hepatitis C. For comparative purposes hea...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical methods 2015-01, Vol.7 (8), p.3431-3437
Hauptverfasser: Arain, S. A, Kazi, T. G, Afridi, H. I, Ullah, N, Arain, M. S, Panhwar, A. H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3437
container_issue 8
container_start_page 3431
container_title Analytical methods
container_volume 7
creator Arain, S. A
Kazi, T. G
Afridi, H. I
Ullah, N
Arain, M. S
Panhwar, A. H
description A new miniaturized solid phase microextraction (SPmE) method, using a micropipette tip, packed with carbon cloth, mounted on a syringe, was developed for preconcentration and determination of trace levels of copper in serum samples of male adolescents having hepatitis C. For comparative purposes healthy boys of the same age group (12-15 years), socioeconomic status and residential areas were also selected. The sample solution was treated with a complexing reagent 8-hydroxyquinoline (oxine), drawn into the syringe fitted with an ACC filled micropipette tip and dispensed manually for 2-10 drawing/discharging cycles. The analytes retained on ACC in a micropipette tip-syringe system were eluted with different volumes (50-200 μL) of 2 mol L −1 HNO 3 in ethanol by 1-5 drawing/dispensing cycles. The influence of different analytical parameters (amount of ACC, oxine concentration, sample volume, pH, drawing and dispensing cycles, type and volume of eluent) was investigated to optimize the developed method. The developed method showed a linear response for standards of Cu, over the concentration range of 5-75 μg L −1 with correlation coefficients ( R 2 ) ≥0.997. Under the optimized experimental variables, the enhancement factors and limits of detection (LODs) were obtained to be 56 and 0.36 μg L −1 , respectively, with a relative standard deviation of ≤5%. The validity and accuracy of the developed method were checked using the matrix matched certified reference material of human serum (Sero-M10181). The method was successfully applied for the preconcentration and determination of trace levels of Cu 2+ in serum samples of adolescent male HCV patients and healthy controls of the same age group. A new miniaturized solid phase microextraction (SPmE) method was developed for determining the trace levels of copper in hepatitis C patients.
doi_str_mv 10.1039/c5ay00393h
format Article
fullrecord <record><control><sourceid>proquest_rsc_p</sourceid><recordid>TN_cdi_rsc_primary_c5ay00393h</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1685815177</sourcerecordid><originalsourceid>FETCH-LOGICAL-c349t-98aac58c11ceb5aa70677fe34e94721fee0ceee021783e5763f23dbaef6945c73</originalsourceid><addsrcrecordid>eNp9kcFuFDEMhkcIJErhwh0p3BDSQLLZTCbHagstUiUucOA08mYdNmgyCXGmMLwYr0e2g8qNi235_2zL-pvmueBvBJfmrVWw8FrI44PmTGhlWtNp8_C-7vjj5gnRN847Iztx1vy-xFscYwo4FRYdC37yUObsf-GBURz9gaUjEFbB5og_SwZbfJxOrI0pYWZ-YoR5DmwmP31lsKLJJywFWfGpEi0tuYrIaKGCoY6GvZ_qiR--HNcBRhDSeNrgRgjIoMTaZ7CnmNPdSUpoS44BS16eNo8cjITP_ubz5vP7d5921-3Nx6sPu4ub1sqtKa3pAazqrRAW9wpA805rh3KLZqs3wiFyizVshO4lKt1Jt5GHPaDrzFZZLc-bV-velOP3GakMwZPFcYQJ40yD6HrVCyX0CX29ovUZooxuSNkHyMsg-HByZ9ipiy937lxX-MUKZ7L33D_3qv7yf_qQDk7-AQkmnso</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1685815177</pqid></control><display><type>article</type><title>Development of miniaturized solid phase microextraction of copper in serum using a micropipette tip in-syringe system combined with micro sampling flame atomic absorption spectrometry</title><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Arain, S. A ; Kazi, T. G ; Afridi, H. I ; Ullah, N ; Arain, M. S ; Panhwar, A. H</creator><creatorcontrib>Arain, S. A ; Kazi, T. G ; Afridi, H. I ; Ullah, N ; Arain, M. S ; Panhwar, A. H</creatorcontrib><description>A new miniaturized solid phase microextraction (SPmE) method, using a micropipette tip, packed with carbon cloth, mounted on a syringe, was developed for preconcentration and determination of trace levels of copper in serum samples of male adolescents having hepatitis C. For comparative purposes healthy boys of the same age group (12-15 years), socioeconomic status and residential areas were also selected. The sample solution was treated with a complexing reagent 8-hydroxyquinoline (oxine), drawn into the syringe fitted with an ACC filled micropipette tip and dispensed manually for 2-10 drawing/discharging cycles. The analytes retained on ACC in a micropipette tip-syringe system were eluted with different volumes (50-200 μL) of 2 mol L −1 HNO 3 in ethanol by 1-5 drawing/dispensing cycles. The influence of different analytical parameters (amount of ACC, oxine concentration, sample volume, pH, drawing and dispensing cycles, type and volume of eluent) was investigated to optimize the developed method. The developed method showed a linear response for standards of Cu, over the concentration range of 5-75 μg L −1 with correlation coefficients ( R 2 ) ≥0.997. Under the optimized experimental variables, the enhancement factors and limits of detection (LODs) were obtained to be 56 and 0.36 μg L −1 , respectively, with a relative standard deviation of ≤5%. The validity and accuracy of the developed method were checked using the matrix matched certified reference material of human serum (Sero-M10181). The method was successfully applied for the preconcentration and determination of trace levels of Cu 2+ in serum samples of adolescent male HCV patients and healthy controls of the same age group. A new miniaturized solid phase microextraction (SPmE) method was developed for determining the trace levels of copper in hepatitis C patients.</description><identifier>ISSN: 1759-9660</identifier><identifier>EISSN: 1759-9679</identifier><identifier>DOI: 10.1039/c5ay00393h</identifier><language>eng</language><subject>Adolescents ; Copper ; Ethyl alcohol ; Mathematical analysis ; Serums ; Solid phases</subject><ispartof>Analytical methods, 2015-01, Vol.7 (8), p.3431-3437</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c349t-98aac58c11ceb5aa70677fe34e94721fee0ceee021783e5763f23dbaef6945c73</citedby><cites>FETCH-LOGICAL-c349t-98aac58c11ceb5aa70677fe34e94721fee0ceee021783e5763f23dbaef6945c73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Arain, S. A</creatorcontrib><creatorcontrib>Kazi, T. G</creatorcontrib><creatorcontrib>Afridi, H. I</creatorcontrib><creatorcontrib>Ullah, N</creatorcontrib><creatorcontrib>Arain, M. S</creatorcontrib><creatorcontrib>Panhwar, A. H</creatorcontrib><title>Development of miniaturized solid phase microextraction of copper in serum using a micropipette tip in-syringe system combined with micro sampling flame atomic absorption spectrometry</title><title>Analytical methods</title><description>A new miniaturized solid phase microextraction (SPmE) method, using a micropipette tip, packed with carbon cloth, mounted on a syringe, was developed for preconcentration and determination of trace levels of copper in serum samples of male adolescents having hepatitis C. For comparative purposes healthy boys of the same age group (12-15 years), socioeconomic status and residential areas were also selected. The sample solution was treated with a complexing reagent 8-hydroxyquinoline (oxine), drawn into the syringe fitted with an ACC filled micropipette tip and dispensed manually for 2-10 drawing/discharging cycles. The analytes retained on ACC in a micropipette tip-syringe system were eluted with different volumes (50-200 μL) of 2 mol L −1 HNO 3 in ethanol by 1-5 drawing/dispensing cycles. The influence of different analytical parameters (amount of ACC, oxine concentration, sample volume, pH, drawing and dispensing cycles, type and volume of eluent) was investigated to optimize the developed method. The developed method showed a linear response for standards of Cu, over the concentration range of 5-75 μg L −1 with correlation coefficients ( R 2 ) ≥0.997. Under the optimized experimental variables, the enhancement factors and limits of detection (LODs) were obtained to be 56 and 0.36 μg L −1 , respectively, with a relative standard deviation of ≤5%. The validity and accuracy of the developed method were checked using the matrix matched certified reference material of human serum (Sero-M10181). The method was successfully applied for the preconcentration and determination of trace levels of Cu 2+ in serum samples of adolescent male HCV patients and healthy controls of the same age group. A new miniaturized solid phase microextraction (SPmE) method was developed for determining the trace levels of copper in hepatitis C patients.</description><subject>Adolescents</subject><subject>Copper</subject><subject>Ethyl alcohol</subject><subject>Mathematical analysis</subject><subject>Serums</subject><subject>Solid phases</subject><issn>1759-9660</issn><issn>1759-9679</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNp9kcFuFDEMhkcIJErhwh0p3BDSQLLZTCbHagstUiUucOA08mYdNmgyCXGmMLwYr0e2g8qNi235_2zL-pvmueBvBJfmrVWw8FrI44PmTGhlWtNp8_C-7vjj5gnRN847Iztx1vy-xFscYwo4FRYdC37yUObsf-GBURz9gaUjEFbB5og_SwZbfJxOrI0pYWZ-YoR5DmwmP31lsKLJJywFWfGpEi0tuYrIaKGCoY6GvZ_qiR--HNcBRhDSeNrgRgjIoMTaZ7CnmNPdSUpoS44BS16eNo8cjITP_ubz5vP7d5921-3Nx6sPu4ub1sqtKa3pAazqrRAW9wpA805rh3KLZqs3wiFyizVshO4lKt1Jt5GHPaDrzFZZLc-bV-velOP3GakMwZPFcYQJ40yD6HrVCyX0CX29ovUZooxuSNkHyMsg-HByZ9ipiy937lxX-MUKZ7L33D_3qv7yf_qQDk7-AQkmnso</recordid><startdate>20150101</startdate><enddate>20150101</enddate><creator>Arain, S. A</creator><creator>Kazi, T. G</creator><creator>Afridi, H. I</creator><creator>Ullah, N</creator><creator>Arain, M. S</creator><creator>Panhwar, A. H</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20150101</creationdate><title>Development of miniaturized solid phase microextraction of copper in serum using a micropipette tip in-syringe system combined with micro sampling flame atomic absorption spectrometry</title><author>Arain, S. A ; Kazi, T. G ; Afridi, H. I ; Ullah, N ; Arain, M. S ; Panhwar, A. H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c349t-98aac58c11ceb5aa70677fe34e94721fee0ceee021783e5763f23dbaef6945c73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Adolescents</topic><topic>Copper</topic><topic>Ethyl alcohol</topic><topic>Mathematical analysis</topic><topic>Serums</topic><topic>Solid phases</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Arain, S. A</creatorcontrib><creatorcontrib>Kazi, T. G</creatorcontrib><creatorcontrib>Afridi, H. I</creatorcontrib><creatorcontrib>Ullah, N</creatorcontrib><creatorcontrib>Arain, M. S</creatorcontrib><creatorcontrib>Panhwar, A. H</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Analytical methods</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Arain, S. A</au><au>Kazi, T. G</au><au>Afridi, H. I</au><au>Ullah, N</au><au>Arain, M. S</au><au>Panhwar, A. H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of miniaturized solid phase microextraction of copper in serum using a micropipette tip in-syringe system combined with micro sampling flame atomic absorption spectrometry</atitle><jtitle>Analytical methods</jtitle><date>2015-01-01</date><risdate>2015</risdate><volume>7</volume><issue>8</issue><spage>3431</spage><epage>3437</epage><pages>3431-3437</pages><issn>1759-9660</issn><eissn>1759-9679</eissn><abstract>A new miniaturized solid phase microextraction (SPmE) method, using a micropipette tip, packed with carbon cloth, mounted on a syringe, was developed for preconcentration and determination of trace levels of copper in serum samples of male adolescents having hepatitis C. For comparative purposes healthy boys of the same age group (12-15 years), socioeconomic status and residential areas were also selected. The sample solution was treated with a complexing reagent 8-hydroxyquinoline (oxine), drawn into the syringe fitted with an ACC filled micropipette tip and dispensed manually for 2-10 drawing/discharging cycles. The analytes retained on ACC in a micropipette tip-syringe system were eluted with different volumes (50-200 μL) of 2 mol L −1 HNO 3 in ethanol by 1-5 drawing/dispensing cycles. The influence of different analytical parameters (amount of ACC, oxine concentration, sample volume, pH, drawing and dispensing cycles, type and volume of eluent) was investigated to optimize the developed method. The developed method showed a linear response for standards of Cu, over the concentration range of 5-75 μg L −1 with correlation coefficients ( R 2 ) ≥0.997. Under the optimized experimental variables, the enhancement factors and limits of detection (LODs) were obtained to be 56 and 0.36 μg L −1 , respectively, with a relative standard deviation of ≤5%. The validity and accuracy of the developed method were checked using the matrix matched certified reference material of human serum (Sero-M10181). The method was successfully applied for the preconcentration and determination of trace levels of Cu 2+ in serum samples of adolescent male HCV patients and healthy controls of the same age group. A new miniaturized solid phase microextraction (SPmE) method was developed for determining the trace levels of copper in hepatitis C patients.</abstract><doi>10.1039/c5ay00393h</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1759-9660
ispartof Analytical methods, 2015-01, Vol.7 (8), p.3431-3437
issn 1759-9660
1759-9679
language eng
recordid cdi_rsc_primary_c5ay00393h
source Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Adolescents
Copper
Ethyl alcohol
Mathematical analysis
Serums
Solid phases
title Development of miniaturized solid phase microextraction of copper in serum using a micropipette tip in-syringe system combined with micro sampling flame atomic absorption spectrometry
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T06%3A34%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_rsc_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20miniaturized%20solid%20phase%20microextraction%20of%20copper%20in%20serum%20using%20a%20micropipette%20tip%20in-syringe%20system%20combined%20with%20micro%20sampling%20flame%20atomic%20absorption%20spectrometry&rft.jtitle=Analytical%20methods&rft.au=Arain,%20S.%20A&rft.date=2015-01-01&rft.volume=7&rft.issue=8&rft.spage=3431&rft.epage=3437&rft.pages=3431-3437&rft.issn=1759-9660&rft.eissn=1759-9679&rft_id=info:doi/10.1039/c5ay00393h&rft_dat=%3Cproquest_rsc_p%3E1685815177%3C/proquest_rsc_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1685815177&rft_id=info:pmid/&rfr_iscdi=true