Sensitive, quantitative, and high-throughput detection of angiogenic markers using shape-coded hydrogel microparticlesElectronic supplementary information (ESI) available. See DOI: 10.1039/c5an00358j

Elevated serum concentrations of angiogenic markers including vascular endothelial growth factor (VEGF), fibroblast growth factor (FGF), and platelet-derived growth factor (PDGF) have been correlated with various clinical disorders including cancer, cardiovascular diseases, diabetes mellitus, and li...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Al-Ameen, Mohammad Ali, Li, Ji, Beer, David G, Ghosh, Gargi
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 4539
container_issue 13
container_start_page 453
container_title
container_volume 14
creator Al-Ameen, Mohammad Ali
Li, Ji
Beer, David G
Ghosh, Gargi
description Elevated serum concentrations of angiogenic markers including vascular endothelial growth factor (VEGF), fibroblast growth factor (FGF), and platelet-derived growth factor (PDGF) have been correlated with various clinical disorders including cancer, cardiovascular diseases, diabetes mellitus, and liver fibrosis. In addition, the correlation between the serum concentrations of these factors, clinical diagnosis, prognosis, and response to therapeutic agents is significant. Thereby suggesting high-throughput detection of serum levels of angiogenic markers has important implications in early detection of different clinical disorders as well as for subsequent therapy monitoring. Here, we demonstrate the feasibility of utilization of shape-coded hydrogel microparticle based suspension arrays for quantitative and reproducible measurement of VEGF, FGF, and PDGF in single and multiplexed assays. Bio-inert PEG hydrogel attenuated the background signal thereby improving the sensitivity of the detection method as well as eliminating the need for blocking the proteins. In the singleplexed assay, the detection limits of 1.7 pg ml −1 , 1.4 pg ml −1 , and 1.5 pg ml −1 for VEGF, FGF, and PDGF respectively indicated that the sensitivity of the developed method exceeds that of the conventional technologies. We also demonstrated that in the multiplexed assays, recovery of the proteins was within 20% of the expected values. The practical applicability of the hydrogel microparticle based detection system was established by demonstrating the ability of the system to quantify the production of VEGF, FGF, and PDGF by breast cancer cells (MDA-MB-231). Demonstration of the application of shape coded hydrogel microparticles for multiplexed detection of angiogenic molecules. Utilization of single fluorophore eliminates the spectral overlap associated with microparticle based multiplexed analysis.
doi_str_mv 10.1039/c5an00358j
format Article
fullrecord <record><control><sourceid>rsc</sourceid><recordid>TN_cdi_rsc_primary_c5an00358j</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>c5an00358j</sourcerecordid><originalsourceid>FETCH-rsc_primary_c5an00358j3</originalsourceid><addsrcrecordid>eNqFj01PwzAMhiMEEuPjwh3J3ECiI13XaXCFIXbiMO6TSd3WI01Ckk7qL-RvET4kDkhwsl6_j1_bQpzkcpzL4vpKlWikLMr5ZkeM8mI2zcpyMt8VI5m62WRWTvfFQQibJHNZypF4W5EJHHlLl_Dao4kc8UuhqaDlps1i623ftK6PUFEkFdkasHUCGrYNGVbQoX8hH6APbBoILTrKlK0oJQyVT5CGjpW3Dn1kpSksdMrx9mM29M5p6shE9AOwqa3v8HPH-WK1vADcImt81jSGFRHcPS5v4Pe7R2KvRh3o-LseitP7xdPtQ-aDWjvP6cJh_YMX__tnf_lrV9XFO2W8dr0</addsrcrecordid><sourcetype>Enrichment Source</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Sensitive, quantitative, and high-throughput detection of angiogenic markers using shape-coded hydrogel microparticlesElectronic supplementary information (ESI) available. See DOI: 10.1039/c5an00358j</title><source>Royal Society of Chemistry Journals Archive (1841-2007)</source><source>Royal Society Of Chemistry Journals</source><source>Alma/SFX Local Collection</source><creator>Al-Ameen, Mohammad Ali ; Li, Ji ; Beer, David G ; Ghosh, Gargi</creator><creatorcontrib>Al-Ameen, Mohammad Ali ; Li, Ji ; Beer, David G ; Ghosh, Gargi</creatorcontrib><description>Elevated serum concentrations of angiogenic markers including vascular endothelial growth factor (VEGF), fibroblast growth factor (FGF), and platelet-derived growth factor (PDGF) have been correlated with various clinical disorders including cancer, cardiovascular diseases, diabetes mellitus, and liver fibrosis. In addition, the correlation between the serum concentrations of these factors, clinical diagnosis, prognosis, and response to therapeutic agents is significant. Thereby suggesting high-throughput detection of serum levels of angiogenic markers has important implications in early detection of different clinical disorders as well as for subsequent therapy monitoring. Here, we demonstrate the feasibility of utilization of shape-coded hydrogel microparticle based suspension arrays for quantitative and reproducible measurement of VEGF, FGF, and PDGF in single and multiplexed assays. Bio-inert PEG hydrogel attenuated the background signal thereby improving the sensitivity of the detection method as well as eliminating the need for blocking the proteins. In the singleplexed assay, the detection limits of 1.7 pg ml −1 , 1.4 pg ml −1 , and 1.5 pg ml −1 for VEGF, FGF, and PDGF respectively indicated that the sensitivity of the developed method exceeds that of the conventional technologies. We also demonstrated that in the multiplexed assays, recovery of the proteins was within 20% of the expected values. The practical applicability of the hydrogel microparticle based detection system was established by demonstrating the ability of the system to quantify the production of VEGF, FGF, and PDGF by breast cancer cells (MDA-MB-231). Demonstration of the application of shape coded hydrogel microparticles for multiplexed detection of angiogenic molecules. Utilization of single fluorophore eliminates the spectral overlap associated with microparticle based multiplexed analysis.</description><identifier>ISSN: 0003-2654</identifier><identifier>EISSN: 1364-5528</identifier><identifier>DOI: 10.1039/c5an00358j</identifier><language>eng</language><creationdate>2015-06</creationdate><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,2836,27933,27934</link.rule.ids></links><search><creatorcontrib>Al-Ameen, Mohammad Ali</creatorcontrib><creatorcontrib>Li, Ji</creatorcontrib><creatorcontrib>Beer, David G</creatorcontrib><creatorcontrib>Ghosh, Gargi</creatorcontrib><title>Sensitive, quantitative, and high-throughput detection of angiogenic markers using shape-coded hydrogel microparticlesElectronic supplementary information (ESI) available. See DOI: 10.1039/c5an00358j</title><description>Elevated serum concentrations of angiogenic markers including vascular endothelial growth factor (VEGF), fibroblast growth factor (FGF), and platelet-derived growth factor (PDGF) have been correlated with various clinical disorders including cancer, cardiovascular diseases, diabetes mellitus, and liver fibrosis. In addition, the correlation between the serum concentrations of these factors, clinical diagnosis, prognosis, and response to therapeutic agents is significant. Thereby suggesting high-throughput detection of serum levels of angiogenic markers has important implications in early detection of different clinical disorders as well as for subsequent therapy monitoring. Here, we demonstrate the feasibility of utilization of shape-coded hydrogel microparticle based suspension arrays for quantitative and reproducible measurement of VEGF, FGF, and PDGF in single and multiplexed assays. Bio-inert PEG hydrogel attenuated the background signal thereby improving the sensitivity of the detection method as well as eliminating the need for blocking the proteins. In the singleplexed assay, the detection limits of 1.7 pg ml −1 , 1.4 pg ml −1 , and 1.5 pg ml −1 for VEGF, FGF, and PDGF respectively indicated that the sensitivity of the developed method exceeds that of the conventional technologies. We also demonstrated that in the multiplexed assays, recovery of the proteins was within 20% of the expected values. The practical applicability of the hydrogel microparticle based detection system was established by demonstrating the ability of the system to quantify the production of VEGF, FGF, and PDGF by breast cancer cells (MDA-MB-231). Demonstration of the application of shape coded hydrogel microparticles for multiplexed detection of angiogenic molecules. Utilization of single fluorophore eliminates the spectral overlap associated with microparticle based multiplexed analysis.</description><issn>0003-2654</issn><issn>1364-5528</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNqFj01PwzAMhiMEEuPjwh3J3ECiI13XaXCFIXbiMO6TSd3WI01Ckk7qL-RvET4kDkhwsl6_j1_bQpzkcpzL4vpKlWikLMr5ZkeM8mI2zcpyMt8VI5m62WRWTvfFQQibJHNZypF4W5EJHHlLl_Dao4kc8UuhqaDlps1i623ftK6PUFEkFdkasHUCGrYNGVbQoX8hH6APbBoILTrKlK0oJQyVT5CGjpW3Dn1kpSksdMrx9mM29M5p6shE9AOwqa3v8HPH-WK1vADcImt81jSGFRHcPS5v4Pe7R2KvRh3o-LseitP7xdPtQ-aDWjvP6cJh_YMX__tnf_lrV9XFO2W8dr0</recordid><startdate>20150615</startdate><enddate>20150615</enddate><creator>Al-Ameen, Mohammad Ali</creator><creator>Li, Ji</creator><creator>Beer, David G</creator><creator>Ghosh, Gargi</creator><scope/></search><sort><creationdate>20150615</creationdate><title>Sensitive, quantitative, and high-throughput detection of angiogenic markers using shape-coded hydrogel microparticlesElectronic supplementary information (ESI) available. See DOI: 10.1039/c5an00358j</title><author>Al-Ameen, Mohammad Ali ; Li, Ji ; Beer, David G ; Ghosh, Gargi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-rsc_primary_c5an00358j3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Al-Ameen, Mohammad Ali</creatorcontrib><creatorcontrib>Li, Ji</creatorcontrib><creatorcontrib>Beer, David G</creatorcontrib><creatorcontrib>Ghosh, Gargi</creatorcontrib></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Al-Ameen, Mohammad Ali</au><au>Li, Ji</au><au>Beer, David G</au><au>Ghosh, Gargi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sensitive, quantitative, and high-throughput detection of angiogenic markers using shape-coded hydrogel microparticlesElectronic supplementary information (ESI) available. See DOI: 10.1039/c5an00358j</atitle><date>2015-06-15</date><risdate>2015</risdate><volume>14</volume><issue>13</issue><spage>453</spage><epage>4539</epage><pages>453-4539</pages><issn>0003-2654</issn><eissn>1364-5528</eissn><abstract>Elevated serum concentrations of angiogenic markers including vascular endothelial growth factor (VEGF), fibroblast growth factor (FGF), and platelet-derived growth factor (PDGF) have been correlated with various clinical disorders including cancer, cardiovascular diseases, diabetes mellitus, and liver fibrosis. In addition, the correlation between the serum concentrations of these factors, clinical diagnosis, prognosis, and response to therapeutic agents is significant. Thereby suggesting high-throughput detection of serum levels of angiogenic markers has important implications in early detection of different clinical disorders as well as for subsequent therapy monitoring. Here, we demonstrate the feasibility of utilization of shape-coded hydrogel microparticle based suspension arrays for quantitative and reproducible measurement of VEGF, FGF, and PDGF in single and multiplexed assays. Bio-inert PEG hydrogel attenuated the background signal thereby improving the sensitivity of the detection method as well as eliminating the need for blocking the proteins. In the singleplexed assay, the detection limits of 1.7 pg ml −1 , 1.4 pg ml −1 , and 1.5 pg ml −1 for VEGF, FGF, and PDGF respectively indicated that the sensitivity of the developed method exceeds that of the conventional technologies. We also demonstrated that in the multiplexed assays, recovery of the proteins was within 20% of the expected values. The practical applicability of the hydrogel microparticle based detection system was established by demonstrating the ability of the system to quantify the production of VEGF, FGF, and PDGF by breast cancer cells (MDA-MB-231). Demonstration of the application of shape coded hydrogel microparticles for multiplexed detection of angiogenic molecules. Utilization of single fluorophore eliminates the spectral overlap associated with microparticle based multiplexed analysis.</abstract><doi>10.1039/c5an00358j</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2654
ispartof
issn 0003-2654
1364-5528
language eng
recordid cdi_rsc_primary_c5an00358j
source Royal Society of Chemistry Journals Archive (1841-2007); Royal Society Of Chemistry Journals; Alma/SFX Local Collection
title Sensitive, quantitative, and high-throughput detection of angiogenic markers using shape-coded hydrogel microparticlesElectronic supplementary information (ESI) available. See DOI: 10.1039/c5an00358j
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-01T07%3A35%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-rsc&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sensitive,%20quantitative,%20and%20high-throughput%20detection%20of%20angiogenic%20markers%20using%20shape-coded%20hydrogel%20microparticlesElectronic%20supplementary%20information%20(ESI)%20available.%20See%20DOI:%2010.1039/c5an00358j&rft.au=Al-Ameen,%20Mohammad%20Ali&rft.date=2015-06-15&rft.volume=14&rft.issue=13&rft.spage=453&rft.epage=4539&rft.pages=453-4539&rft.issn=0003-2654&rft.eissn=1364-5528&rft_id=info:doi/10.1039/c5an00358j&rft_dat=%3Crsc%3Ec5an00358j%3C/rsc%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true