FISH in chips: turning microfluidic fluorescence in situ hybridization into a quantitative and clinically reliable molecular diagnosis toolElectronic supplementary information (ESI) available. See DOI: 10.1039/c4lc01059k

Microfluidic systems bear promise to provide new powerful tools for the molecular characterization of cancer cells, in particular for the routine detection of multiple cancer biomarkers using a minute amount of the sample. However, taking miniaturized cell-based assays into the clinics requires the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Perez-Toralla, Karla, Mottet, Guillaume, Guneri, Ezgi Tulukcuoglu, Champ, Jérôme, Bidard, François-Clément, Pierga, Jean-Yves, Klijanienko, Jerzy, Draskovic, Irena, Malaquin, Laurent, Viovy, Jean-Louis, Descroix, Stéphanie
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 822
container_issue 3
container_start_page 811
container_title
container_volume 15
creator Perez-Toralla, Karla
Mottet, Guillaume
Guneri, Ezgi Tulukcuoglu
Champ, Jérôme
Bidard, François-Clément
Pierga, Jean-Yves
Klijanienko, Jerzy
Draskovic, Irena
Malaquin, Laurent
Viovy, Jean-Louis
Descroix, Stéphanie
description Microfluidic systems bear promise to provide new powerful tools for the molecular characterization of cancer cells, in particular for the routine detection of multiple cancer biomarkers using a minute amount of the sample. However, taking miniaturized cell-based assays into the clinics requires the implementation and validation of complex biological protocols on chip, as well as the development of disposable microdevices produced at a low cost. Based on a recently developed microfluidic chip made of Cyclic Olefin Copolymer for cell immobilization with minimal dead volume and controlled shear stress, we developed a protocol performed entirely in the liquid phase, allowing the immobilization and fixation of cells and their quantitative characterization by fluorescence in situ hybridization. We demonstrated first in cell lines and then in two clinical case studies the potential of this method to perform quantitative copy number measurement and clinical scoring of the amplification of the ERBB2 gene, a decisive biomarker for the prescription of HER2+ related targeted therapies. This validation was performed in a blind protocol in two clinical case studies, in reference to the gold standard and clinically used method based on glass slides. We obtained a comparable reproducibility and a minor difference in apparent amplification, which can be corrected by internal calibration. The method thus reaches the standard of robustness needed for clinical use. The protocol can be fully automated, and its consumption of samples and DNA probes is reduced as compared to glass slide protocols by a factor of at least 10. The total duration of the assay is divided by two. A complete, simple and low cost FISH platform suitable for the quantitative molecular typing of prognostic biomarkers for cancer patient management.
doi_str_mv 10.1039/c4lc01059k
format Article
fullrecord <record><control><sourceid>rsc</sourceid><recordid>TN_cdi_rsc_primary_c4lc01059k</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>c4lc01059k</sourcerecordid><originalsourceid>FETCH-rsc_primary_c4lc01059k3</originalsourceid><addsrcrecordid>eNqFkDtPw0AQhE8IJMKjoUdaOigSzrJD4rTgKK4oTG9dzudkYX1n7hHJ_FZ-DBeBoECCalbzjWalYewi4ZOEp_mtzEjyhE_zlwM2SrJZOubJPD_8vvPZMTtx7pnzZJrdzUfsfVlWK0ANcou9W4APVqPeQIfSmpYCNighqrHKSaWl2mcd-gDbYW0jfRMejY6uNyDgNQjt0Udvp0DoBiShRimIBrCKUKxJQWdIyUDCQoNio41DB94YKqLtrYl5cKHvSXVKe2GHWN4a230-ui6q8gbETiDtyyZQKQUPj-UCfm9wxo5aQU6df-kpu1wWT_ersXWy7i12sbz-iaf_86u_eN03bfoBGiN-YQ</addsrcrecordid><sourcetype>Enrichment Source</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>FISH in chips: turning microfluidic fluorescence in situ hybridization into a quantitative and clinically reliable molecular diagnosis toolElectronic supplementary information (ESI) available. See DOI: 10.1039/c4lc01059k</title><source>Royal Society Of Chemistry Journals</source><source>Alma/SFX Local Collection</source><creator>Perez-Toralla, Karla ; Mottet, Guillaume ; Guneri, Ezgi Tulukcuoglu ; Champ, Jérôme ; Bidard, François-Clément ; Pierga, Jean-Yves ; Klijanienko, Jerzy ; Draskovic, Irena ; Malaquin, Laurent ; Viovy, Jean-Louis ; Descroix, Stéphanie</creator><creatorcontrib>Perez-Toralla, Karla ; Mottet, Guillaume ; Guneri, Ezgi Tulukcuoglu ; Champ, Jérôme ; Bidard, François-Clément ; Pierga, Jean-Yves ; Klijanienko, Jerzy ; Draskovic, Irena ; Malaquin, Laurent ; Viovy, Jean-Louis ; Descroix, Stéphanie</creatorcontrib><description>Microfluidic systems bear promise to provide new powerful tools for the molecular characterization of cancer cells, in particular for the routine detection of multiple cancer biomarkers using a minute amount of the sample. However, taking miniaturized cell-based assays into the clinics requires the implementation and validation of complex biological protocols on chip, as well as the development of disposable microdevices produced at a low cost. Based on a recently developed microfluidic chip made of Cyclic Olefin Copolymer for cell immobilization with minimal dead volume and controlled shear stress, we developed a protocol performed entirely in the liquid phase, allowing the immobilization and fixation of cells and their quantitative characterization by fluorescence in situ hybridization. We demonstrated first in cell lines and then in two clinical case studies the potential of this method to perform quantitative copy number measurement and clinical scoring of the amplification of the ERBB2 gene, a decisive biomarker for the prescription of HER2+ related targeted therapies. This validation was performed in a blind protocol in two clinical case studies, in reference to the gold standard and clinically used method based on glass slides. We obtained a comparable reproducibility and a minor difference in apparent amplification, which can be corrected by internal calibration. The method thus reaches the standard of robustness needed for clinical use. The protocol can be fully automated, and its consumption of samples and DNA probes is reduced as compared to glass slide protocols by a factor of at least 10. The total duration of the assay is divided by two. A complete, simple and low cost FISH platform suitable for the quantitative molecular typing of prognostic biomarkers for cancer patient management.</description><identifier>ISSN: 1473-0197</identifier><identifier>EISSN: 1473-0189</identifier><identifier>DOI: 10.1039/c4lc01059k</identifier><language>eng</language><creationdate>2015-01</creationdate><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Perez-Toralla, Karla</creatorcontrib><creatorcontrib>Mottet, Guillaume</creatorcontrib><creatorcontrib>Guneri, Ezgi Tulukcuoglu</creatorcontrib><creatorcontrib>Champ, Jérôme</creatorcontrib><creatorcontrib>Bidard, François-Clément</creatorcontrib><creatorcontrib>Pierga, Jean-Yves</creatorcontrib><creatorcontrib>Klijanienko, Jerzy</creatorcontrib><creatorcontrib>Draskovic, Irena</creatorcontrib><creatorcontrib>Malaquin, Laurent</creatorcontrib><creatorcontrib>Viovy, Jean-Louis</creatorcontrib><creatorcontrib>Descroix, Stéphanie</creatorcontrib><title>FISH in chips: turning microfluidic fluorescence in situ hybridization into a quantitative and clinically reliable molecular diagnosis toolElectronic supplementary information (ESI) available. See DOI: 10.1039/c4lc01059k</title><description>Microfluidic systems bear promise to provide new powerful tools for the molecular characterization of cancer cells, in particular for the routine detection of multiple cancer biomarkers using a minute amount of the sample. However, taking miniaturized cell-based assays into the clinics requires the implementation and validation of complex biological protocols on chip, as well as the development of disposable microdevices produced at a low cost. Based on a recently developed microfluidic chip made of Cyclic Olefin Copolymer for cell immobilization with minimal dead volume and controlled shear stress, we developed a protocol performed entirely in the liquid phase, allowing the immobilization and fixation of cells and their quantitative characterization by fluorescence in situ hybridization. We demonstrated first in cell lines and then in two clinical case studies the potential of this method to perform quantitative copy number measurement and clinical scoring of the amplification of the ERBB2 gene, a decisive biomarker for the prescription of HER2+ related targeted therapies. This validation was performed in a blind protocol in two clinical case studies, in reference to the gold standard and clinically used method based on glass slides. We obtained a comparable reproducibility and a minor difference in apparent amplification, which can be corrected by internal calibration. The method thus reaches the standard of robustness needed for clinical use. The protocol can be fully automated, and its consumption of samples and DNA probes is reduced as compared to glass slide protocols by a factor of at least 10. The total duration of the assay is divided by two. A complete, simple and low cost FISH platform suitable for the quantitative molecular typing of prognostic biomarkers for cancer patient management.</description><issn>1473-0197</issn><issn>1473-0189</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNqFkDtPw0AQhE8IJMKjoUdaOigSzrJD4rTgKK4oTG9dzudkYX1n7hHJ_FZ-DBeBoECCalbzjWalYewi4ZOEp_mtzEjyhE_zlwM2SrJZOubJPD_8vvPZMTtx7pnzZJrdzUfsfVlWK0ANcou9W4APVqPeQIfSmpYCNighqrHKSaWl2mcd-gDbYW0jfRMejY6uNyDgNQjt0Udvp0DoBiShRimIBrCKUKxJQWdIyUDCQoNio41DB94YKqLtrYl5cKHvSXVKe2GHWN4a230-ui6q8gbETiDtyyZQKQUPj-UCfm9wxo5aQU6df-kpu1wWT_ersXWy7i12sbz-iaf_86u_eN03bfoBGiN-YQ</recordid><startdate>20150122</startdate><enddate>20150122</enddate><creator>Perez-Toralla, Karla</creator><creator>Mottet, Guillaume</creator><creator>Guneri, Ezgi Tulukcuoglu</creator><creator>Champ, Jérôme</creator><creator>Bidard, François-Clément</creator><creator>Pierga, Jean-Yves</creator><creator>Klijanienko, Jerzy</creator><creator>Draskovic, Irena</creator><creator>Malaquin, Laurent</creator><creator>Viovy, Jean-Louis</creator><creator>Descroix, Stéphanie</creator><scope/></search><sort><creationdate>20150122</creationdate><title>FISH in chips: turning microfluidic fluorescence in situ hybridization into a quantitative and clinically reliable molecular diagnosis toolElectronic supplementary information (ESI) available. See DOI: 10.1039/c4lc01059k</title><author>Perez-Toralla, Karla ; Mottet, Guillaume ; Guneri, Ezgi Tulukcuoglu ; Champ, Jérôme ; Bidard, François-Clément ; Pierga, Jean-Yves ; Klijanienko, Jerzy ; Draskovic, Irena ; Malaquin, Laurent ; Viovy, Jean-Louis ; Descroix, Stéphanie</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-rsc_primary_c4lc01059k3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Perez-Toralla, Karla</creatorcontrib><creatorcontrib>Mottet, Guillaume</creatorcontrib><creatorcontrib>Guneri, Ezgi Tulukcuoglu</creatorcontrib><creatorcontrib>Champ, Jérôme</creatorcontrib><creatorcontrib>Bidard, François-Clément</creatorcontrib><creatorcontrib>Pierga, Jean-Yves</creatorcontrib><creatorcontrib>Klijanienko, Jerzy</creatorcontrib><creatorcontrib>Draskovic, Irena</creatorcontrib><creatorcontrib>Malaquin, Laurent</creatorcontrib><creatorcontrib>Viovy, Jean-Louis</creatorcontrib><creatorcontrib>Descroix, Stéphanie</creatorcontrib></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Perez-Toralla, Karla</au><au>Mottet, Guillaume</au><au>Guneri, Ezgi Tulukcuoglu</au><au>Champ, Jérôme</au><au>Bidard, François-Clément</au><au>Pierga, Jean-Yves</au><au>Klijanienko, Jerzy</au><au>Draskovic, Irena</au><au>Malaquin, Laurent</au><au>Viovy, Jean-Louis</au><au>Descroix, Stéphanie</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>FISH in chips: turning microfluidic fluorescence in situ hybridization into a quantitative and clinically reliable molecular diagnosis toolElectronic supplementary information (ESI) available. See DOI: 10.1039/c4lc01059k</atitle><date>2015-01-22</date><risdate>2015</risdate><volume>15</volume><issue>3</issue><spage>811</spage><epage>822</epage><pages>811-822</pages><issn>1473-0197</issn><eissn>1473-0189</eissn><abstract>Microfluidic systems bear promise to provide new powerful tools for the molecular characterization of cancer cells, in particular for the routine detection of multiple cancer biomarkers using a minute amount of the sample. However, taking miniaturized cell-based assays into the clinics requires the implementation and validation of complex biological protocols on chip, as well as the development of disposable microdevices produced at a low cost. Based on a recently developed microfluidic chip made of Cyclic Olefin Copolymer for cell immobilization with minimal dead volume and controlled shear stress, we developed a protocol performed entirely in the liquid phase, allowing the immobilization and fixation of cells and their quantitative characterization by fluorescence in situ hybridization. We demonstrated first in cell lines and then in two clinical case studies the potential of this method to perform quantitative copy number measurement and clinical scoring of the amplification of the ERBB2 gene, a decisive biomarker for the prescription of HER2+ related targeted therapies. This validation was performed in a blind protocol in two clinical case studies, in reference to the gold standard and clinically used method based on glass slides. We obtained a comparable reproducibility and a minor difference in apparent amplification, which can be corrected by internal calibration. The method thus reaches the standard of robustness needed for clinical use. The protocol can be fully automated, and its consumption of samples and DNA probes is reduced as compared to glass slide protocols by a factor of at least 10. The total duration of the assay is divided by two. A complete, simple and low cost FISH platform suitable for the quantitative molecular typing of prognostic biomarkers for cancer patient management.</abstract><doi>10.1039/c4lc01059k</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1473-0197
ispartof
issn 1473-0197
1473-0189
language eng
recordid cdi_rsc_primary_c4lc01059k
source Royal Society Of Chemistry Journals; Alma/SFX Local Collection
title FISH in chips: turning microfluidic fluorescence in situ hybridization into a quantitative and clinically reliable molecular diagnosis toolElectronic supplementary information (ESI) available. See DOI: 10.1039/c4lc01059k
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T08%3A57%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-rsc&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=FISH%20in%20chips:%20turning%20microfluidic%20fluorescence%20in%20situ%20hybridization%20into%20a%20quantitative%20and%20clinically%20reliable%20molecular%20diagnosis%20toolElectronic%20supplementary%20information%20(ESI)%20available.%20See%20DOI:%2010.1039/c4lc01059k&rft.au=Perez-Toralla,%20Karla&rft.date=2015-01-22&rft.volume=15&rft.issue=3&rft.spage=811&rft.epage=822&rft.pages=811-822&rft.issn=1473-0197&rft.eissn=1473-0189&rft_id=info:doi/10.1039/c4lc01059k&rft_dat=%3Crsc%3Ec4lc01059k%3C/rsc%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true