Poor concordance of contemporary performance measures in detecting complications in complex endovascular aortic repair

The Agency for Healthcare Research and Quality Patient Safety Indicators (PSI) are quality improvement indicators used to determine hospital performance and, increasingly, to rank surgical programs. The American College of Surgeons National Surgical Quality Improvement Program and the Society for Va...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of vascular surgery 2021-07, Vol.74 (1), p.28-37
Hauptverfasser: Giuliano, Katherine A., Sorber, Rebecca, Hicks, Caitlin W., Abularrage, Christopher J., Lum, Ying Wei, Black, James H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 37
container_issue 1
container_start_page 28
container_title Journal of vascular surgery
container_volume 74
creator Giuliano, Katherine A.
Sorber, Rebecca
Hicks, Caitlin W.
Abularrage, Christopher J.
Lum, Ying Wei
Black, James H.
description The Agency for Healthcare Research and Quality Patient Safety Indicators (PSI) are quality improvement indicators used to determine hospital performance and, increasingly, to rank surgical programs. The American College of Surgeons National Surgical Quality Improvement Program and the Society for Vascular Surgery Vascular Quality Improvement databases are also frequently used to compare outcomes, but definitions of complications vary between the systems and the optimal system for tracking complications in complex endovascular repair remains unclear. Herein we assess the three outcome tracking systems and their ability to capture complications after fenestrated endovascular abdominal aortic aneurysm repair (FEVAR) and open aortic aneurysm repair in a large complex aortic program. Demographic and operative data for patients undergoing repair of juxtarenal or pararenal aortic aneurysms between 2004 and 2018 via both open and FEVAR approaches at the Johns Hopkins Medical Institutions were compiled in a prospectively maintained retrospective database. Postoperative complications were defined according to a surgeon-defined system, the Society for Vascular Surgery Vascular Quality Initiative, the American College of Surgeons National Surgical Quality Improvement Program, and the Agency for Healthcare Research and Quality PSI data dictionaries and were compared between surgical approaches as well as eras before and after the introduction of FEVAR. Complication rates between the classification systems were compared using proportion testing and the strength of the correlation between the systems was evaluated with Spearman's rank test. Of 145 patients, 60 (41.4%) underwent FEVAR and 85 (58.6%) underwent open aortic aneurysm repair. The introduction of fenestrated technology was associated with a decrease in the overall number of complications from 37.2% to 20.6% by surgeon-defined classification system (P = .036). The VQI identified the most complications (39.9% of the entire cohort and 25% of FEVAR cases), followed by the NSQIP (29.0% and 33.3%, respectively) and PSI (4.1% and 5%). The two clinically focused databases were found to correlate well with a surgeon-designed classification system, as well as each other (Spearman ρ ≥ 0.735) but not with PSI (ρ < 0.23). Proportion testing demonstrated the rate of complications identified by PSI to be significantly less than either VQI or NSQIP (P < .001). Specifically, PSI did not effectively identify renal complications
doi_str_mv 10.1016/j.jvs.2020.11.046
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9833289</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0741521420325945</els_id><sourcerecordid>2471456809</sourcerecordid><originalsourceid>FETCH-LOGICAL-c403t-ae235c24f447d503c0a52629de60267750d648262cf0df45158d41ad2d51f1043</originalsourceid><addsrcrecordid>eNp9UcuO1DAQtBCIHRY-gAvKkUuGbj_yEBISWvGSVoIDnC1jdxaPEjvYSbT8PZ6ZZQUXTlZ3VVe7qxh7jrBHwObVYX_Y8p4DLzXuQTYP2A6hb-umg_4h20ErsVYc5QV7kvMBAFF17WN2IYSQ0ALu2PYlxlTZGGxMzgRLVRyO5ULTHJNJv6qZ0hDTdMImMnlNlCsfKkcL2cWHm0Kf5tFbs_gYTtCpQbcVBRc3k-06mlSZmBZvq0Sz8ekpezSYMdOzu_eSfXv_7uvVx_r684dPV2-vaytBLLUhLpTlcpCydQqEBaN4w3tHDfCmbRW4RnalYwdwg1TlPCfROO4UDghSXLI3Z915_T6RsxSWZEY9Jz-V23Q0Xv-LBP9D38RN950QvOuLwMs7gRR_rpQXPflsaRxNoLhmzWWLUh39LlQ8U22KOSca7tcg6GNe-qBLXvqYl0bUJa8y8-Lv_91P_AmoEF6fCVRc2jwlna2nkoXzqdivXfT_kf8NR2OpkQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2471456809</pqid></control><display><type>article</type><title>Poor concordance of contemporary performance measures in detecting complications in complex endovascular aortic repair</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Giuliano, Katherine A. ; Sorber, Rebecca ; Hicks, Caitlin W. ; Abularrage, Christopher J. ; Lum, Ying Wei ; Black, James H.</creator><creatorcontrib>Giuliano, Katherine A. ; Sorber, Rebecca ; Hicks, Caitlin W. ; Abularrage, Christopher J. ; Lum, Ying Wei ; Black, James H.</creatorcontrib><description>The Agency for Healthcare Research and Quality Patient Safety Indicators (PSI) are quality improvement indicators used to determine hospital performance and, increasingly, to rank surgical programs. The American College of Surgeons National Surgical Quality Improvement Program and the Society for Vascular Surgery Vascular Quality Improvement databases are also frequently used to compare outcomes, but definitions of complications vary between the systems and the optimal system for tracking complications in complex endovascular repair remains unclear. Herein we assess the three outcome tracking systems and their ability to capture complications after fenestrated endovascular abdominal aortic aneurysm repair (FEVAR) and open aortic aneurysm repair in a large complex aortic program. Demographic and operative data for patients undergoing repair of juxtarenal or pararenal aortic aneurysms between 2004 and 2018 via both open and FEVAR approaches at the Johns Hopkins Medical Institutions were compiled in a prospectively maintained retrospective database. Postoperative complications were defined according to a surgeon-defined system, the Society for Vascular Surgery Vascular Quality Initiative, the American College of Surgeons National Surgical Quality Improvement Program, and the Agency for Healthcare Research and Quality PSI data dictionaries and were compared between surgical approaches as well as eras before and after the introduction of FEVAR. Complication rates between the classification systems were compared using proportion testing and the strength of the correlation between the systems was evaluated with Spearman's rank test. Of 145 patients, 60 (41.4%) underwent FEVAR and 85 (58.6%) underwent open aortic aneurysm repair. The introduction of fenestrated technology was associated with a decrease in the overall number of complications from 37.2% to 20.6% by surgeon-defined classification system (P = .036). The VQI identified the most complications (39.9% of the entire cohort and 25% of FEVAR cases), followed by the NSQIP (29.0% and 33.3%, respectively) and PSI (4.1% and 5%). The two clinically focused databases were found to correlate well with a surgeon-designed classification system, as well as each other (Spearman ρ ≥ 0.735) but not with PSI (ρ &lt; 0.23). Proportion testing demonstrated the rate of complications identified by PSI to be significantly less than either VQI or NSQIP (P &lt; .001). Specifically, PSI did not effectively identify renal complications (1.4% vs 9.0% by NSQIP and 27.3% by VQI definitions; P &lt; .001). The introduction of FEVAR is associated with an overall decrease in complications in this study. The clinically relevant VQI and NSQIP databases show good concordance in capturing complications; however, PSI did not correlate with either and captured significantly fewer complications. These data highlight the value of high scrutiny classification systems to track postoperative complications and suggest that PSI are insufficient to rank complex aortic programs with high levels of FEVAR use.</description><identifier>ISSN: 0741-5214</identifier><identifier>EISSN: 1097-6809</identifier><identifier>DOI: 10.1016/j.jvs.2020.11.046</identifier><identifier>PMID: 33340701</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Abdominal aortic aneurysm ; Aged ; Aged, 80 and over ; Aortic Aneurysm, Abdominal - diagnostic imaging ; Aortic Aneurysm, Abdominal - surgery ; Baltimore ; Blood Vessel Prosthesis Implantation - adverse effects ; Databases, Factual ; Endovascular Procedures - adverse effects ; Endovascular repair ; Female ; Fenestrated endovascular aortic repair ; Humans ; Male ; Middle Aged ; Patient Safety ; Patient Safety Indicator ; Postoperative Complications - etiology ; Quality Improvement ; Quality Indicators, Health Care ; Retrospective Studies ; Risk Assessment ; Risk Factors ; Time Factors ; Treatment Outcome</subject><ispartof>Journal of vascular surgery, 2021-07, Vol.74 (1), p.28-37</ispartof><rights>2020 Society for Vascular Surgery</rights><rights>Copyright © 2020 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c403t-ae235c24f447d503c0a52629de60267750d648262cf0df45158d41ad2d51f1043</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0741521420325945$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,776,780,881,3536,27903,27904,65309</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33340701$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Giuliano, Katherine A.</creatorcontrib><creatorcontrib>Sorber, Rebecca</creatorcontrib><creatorcontrib>Hicks, Caitlin W.</creatorcontrib><creatorcontrib>Abularrage, Christopher J.</creatorcontrib><creatorcontrib>Lum, Ying Wei</creatorcontrib><creatorcontrib>Black, James H.</creatorcontrib><title>Poor concordance of contemporary performance measures in detecting complications in complex endovascular aortic repair</title><title>Journal of vascular surgery</title><addtitle>J Vasc Surg</addtitle><description>The Agency for Healthcare Research and Quality Patient Safety Indicators (PSI) are quality improvement indicators used to determine hospital performance and, increasingly, to rank surgical programs. The American College of Surgeons National Surgical Quality Improvement Program and the Society for Vascular Surgery Vascular Quality Improvement databases are also frequently used to compare outcomes, but definitions of complications vary between the systems and the optimal system for tracking complications in complex endovascular repair remains unclear. Herein we assess the three outcome tracking systems and their ability to capture complications after fenestrated endovascular abdominal aortic aneurysm repair (FEVAR) and open aortic aneurysm repair in a large complex aortic program. Demographic and operative data for patients undergoing repair of juxtarenal or pararenal aortic aneurysms between 2004 and 2018 via both open and FEVAR approaches at the Johns Hopkins Medical Institutions were compiled in a prospectively maintained retrospective database. Postoperative complications were defined according to a surgeon-defined system, the Society for Vascular Surgery Vascular Quality Initiative, the American College of Surgeons National Surgical Quality Improvement Program, and the Agency for Healthcare Research and Quality PSI data dictionaries and were compared between surgical approaches as well as eras before and after the introduction of FEVAR. Complication rates between the classification systems were compared using proportion testing and the strength of the correlation between the systems was evaluated with Spearman's rank test. Of 145 patients, 60 (41.4%) underwent FEVAR and 85 (58.6%) underwent open aortic aneurysm repair. The introduction of fenestrated technology was associated with a decrease in the overall number of complications from 37.2% to 20.6% by surgeon-defined classification system (P = .036). The VQI identified the most complications (39.9% of the entire cohort and 25% of FEVAR cases), followed by the NSQIP (29.0% and 33.3%, respectively) and PSI (4.1% and 5%). The two clinically focused databases were found to correlate well with a surgeon-designed classification system, as well as each other (Spearman ρ ≥ 0.735) but not with PSI (ρ &lt; 0.23). Proportion testing demonstrated the rate of complications identified by PSI to be significantly less than either VQI or NSQIP (P &lt; .001). Specifically, PSI did not effectively identify renal complications (1.4% vs 9.0% by NSQIP and 27.3% by VQI definitions; P &lt; .001). The introduction of FEVAR is associated with an overall decrease in complications in this study. The clinically relevant VQI and NSQIP databases show good concordance in capturing complications; however, PSI did not correlate with either and captured significantly fewer complications. These data highlight the value of high scrutiny classification systems to track postoperative complications and suggest that PSI are insufficient to rank complex aortic programs with high levels of FEVAR use.</description><subject>Abdominal aortic aneurysm</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Aortic Aneurysm, Abdominal - diagnostic imaging</subject><subject>Aortic Aneurysm, Abdominal - surgery</subject><subject>Baltimore</subject><subject>Blood Vessel Prosthesis Implantation - adverse effects</subject><subject>Databases, Factual</subject><subject>Endovascular Procedures - adverse effects</subject><subject>Endovascular repair</subject><subject>Female</subject><subject>Fenestrated endovascular aortic repair</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Patient Safety</subject><subject>Patient Safety Indicator</subject><subject>Postoperative Complications - etiology</subject><subject>Quality Improvement</subject><subject>Quality Indicators, Health Care</subject><subject>Retrospective Studies</subject><subject>Risk Assessment</subject><subject>Risk Factors</subject><subject>Time Factors</subject><subject>Treatment Outcome</subject><issn>0741-5214</issn><issn>1097-6809</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9UcuO1DAQtBCIHRY-gAvKkUuGbj_yEBISWvGSVoIDnC1jdxaPEjvYSbT8PZ6ZZQUXTlZ3VVe7qxh7jrBHwObVYX_Y8p4DLzXuQTYP2A6hb-umg_4h20ErsVYc5QV7kvMBAFF17WN2IYSQ0ALu2PYlxlTZGGxMzgRLVRyO5ULTHJNJv6qZ0hDTdMImMnlNlCsfKkcL2cWHm0Kf5tFbs_gYTtCpQbcVBRc3k-06mlSZmBZvq0Sz8ekpezSYMdOzu_eSfXv_7uvVx_r684dPV2-vaytBLLUhLpTlcpCydQqEBaN4w3tHDfCmbRW4RnalYwdwg1TlPCfROO4UDghSXLI3Z915_T6RsxSWZEY9Jz-V23Q0Xv-LBP9D38RN950QvOuLwMs7gRR_rpQXPflsaRxNoLhmzWWLUh39LlQ8U22KOSca7tcg6GNe-qBLXvqYl0bUJa8y8-Lv_91P_AmoEF6fCVRc2jwlna2nkoXzqdivXfT_kf8NR2OpkQ</recordid><startdate>20210701</startdate><enddate>20210701</enddate><creator>Giuliano, Katherine A.</creator><creator>Sorber, Rebecca</creator><creator>Hicks, Caitlin W.</creator><creator>Abularrage, Christopher J.</creator><creator>Lum, Ying Wei</creator><creator>Black, James H.</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20210701</creationdate><title>Poor concordance of contemporary performance measures in detecting complications in complex endovascular aortic repair</title><author>Giuliano, Katherine A. ; Sorber, Rebecca ; Hicks, Caitlin W. ; Abularrage, Christopher J. ; Lum, Ying Wei ; Black, James H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c403t-ae235c24f447d503c0a52629de60267750d648262cf0df45158d41ad2d51f1043</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Abdominal aortic aneurysm</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Aortic Aneurysm, Abdominal - diagnostic imaging</topic><topic>Aortic Aneurysm, Abdominal - surgery</topic><topic>Baltimore</topic><topic>Blood Vessel Prosthesis Implantation - adverse effects</topic><topic>Databases, Factual</topic><topic>Endovascular Procedures - adverse effects</topic><topic>Endovascular repair</topic><topic>Female</topic><topic>Fenestrated endovascular aortic repair</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Patient Safety</topic><topic>Patient Safety Indicator</topic><topic>Postoperative Complications - etiology</topic><topic>Quality Improvement</topic><topic>Quality Indicators, Health Care</topic><topic>Retrospective Studies</topic><topic>Risk Assessment</topic><topic>Risk Factors</topic><topic>Time Factors</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Giuliano, Katherine A.</creatorcontrib><creatorcontrib>Sorber, Rebecca</creatorcontrib><creatorcontrib>Hicks, Caitlin W.</creatorcontrib><creatorcontrib>Abularrage, Christopher J.</creatorcontrib><creatorcontrib>Lum, Ying Wei</creatorcontrib><creatorcontrib>Black, James H.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of vascular surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Giuliano, Katherine A.</au><au>Sorber, Rebecca</au><au>Hicks, Caitlin W.</au><au>Abularrage, Christopher J.</au><au>Lum, Ying Wei</au><au>Black, James H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Poor concordance of contemporary performance measures in detecting complications in complex endovascular aortic repair</atitle><jtitle>Journal of vascular surgery</jtitle><addtitle>J Vasc Surg</addtitle><date>2021-07-01</date><risdate>2021</risdate><volume>74</volume><issue>1</issue><spage>28</spage><epage>37</epage><pages>28-37</pages><issn>0741-5214</issn><eissn>1097-6809</eissn><abstract>The Agency for Healthcare Research and Quality Patient Safety Indicators (PSI) are quality improvement indicators used to determine hospital performance and, increasingly, to rank surgical programs. The American College of Surgeons National Surgical Quality Improvement Program and the Society for Vascular Surgery Vascular Quality Improvement databases are also frequently used to compare outcomes, but definitions of complications vary between the systems and the optimal system for tracking complications in complex endovascular repair remains unclear. Herein we assess the three outcome tracking systems and their ability to capture complications after fenestrated endovascular abdominal aortic aneurysm repair (FEVAR) and open aortic aneurysm repair in a large complex aortic program. Demographic and operative data for patients undergoing repair of juxtarenal or pararenal aortic aneurysms between 2004 and 2018 via both open and FEVAR approaches at the Johns Hopkins Medical Institutions were compiled in a prospectively maintained retrospective database. Postoperative complications were defined according to a surgeon-defined system, the Society for Vascular Surgery Vascular Quality Initiative, the American College of Surgeons National Surgical Quality Improvement Program, and the Agency for Healthcare Research and Quality PSI data dictionaries and were compared between surgical approaches as well as eras before and after the introduction of FEVAR. Complication rates between the classification systems were compared using proportion testing and the strength of the correlation between the systems was evaluated with Spearman's rank test. Of 145 patients, 60 (41.4%) underwent FEVAR and 85 (58.6%) underwent open aortic aneurysm repair. The introduction of fenestrated technology was associated with a decrease in the overall number of complications from 37.2% to 20.6% by surgeon-defined classification system (P = .036). The VQI identified the most complications (39.9% of the entire cohort and 25% of FEVAR cases), followed by the NSQIP (29.0% and 33.3%, respectively) and PSI (4.1% and 5%). The two clinically focused databases were found to correlate well with a surgeon-designed classification system, as well as each other (Spearman ρ ≥ 0.735) but not with PSI (ρ &lt; 0.23). Proportion testing demonstrated the rate of complications identified by PSI to be significantly less than either VQI or NSQIP (P &lt; .001). Specifically, PSI did not effectively identify renal complications (1.4% vs 9.0% by NSQIP and 27.3% by VQI definitions; P &lt; .001). The introduction of FEVAR is associated with an overall decrease in complications in this study. The clinically relevant VQI and NSQIP databases show good concordance in capturing complications; however, PSI did not correlate with either and captured significantly fewer complications. These data highlight the value of high scrutiny classification systems to track postoperative complications and suggest that PSI are insufficient to rank complex aortic programs with high levels of FEVAR use.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>33340701</pmid><doi>10.1016/j.jvs.2020.11.046</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0741-5214
ispartof Journal of vascular surgery, 2021-07, Vol.74 (1), p.28-37
issn 0741-5214
1097-6809
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9833289
source MEDLINE; Elsevier ScienceDirect Journals; EZB-FREE-00999 freely available EZB journals
subjects Abdominal aortic aneurysm
Aged
Aged, 80 and over
Aortic Aneurysm, Abdominal - diagnostic imaging
Aortic Aneurysm, Abdominal - surgery
Baltimore
Blood Vessel Prosthesis Implantation - adverse effects
Databases, Factual
Endovascular Procedures - adverse effects
Endovascular repair
Female
Fenestrated endovascular aortic repair
Humans
Male
Middle Aged
Patient Safety
Patient Safety Indicator
Postoperative Complications - etiology
Quality Improvement
Quality Indicators, Health Care
Retrospective Studies
Risk Assessment
Risk Factors
Time Factors
Treatment Outcome
title Poor concordance of contemporary performance measures in detecting complications in complex endovascular aortic repair
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T12%3A56%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Poor%20concordance%20of%20contemporary%20performance%20measures%20in%20detecting%20complications%20in%20complex%20endovascular%20aortic%20repair&rft.jtitle=Journal%20of%20vascular%20surgery&rft.au=Giuliano,%20Katherine%20A.&rft.date=2021-07-01&rft.volume=74&rft.issue=1&rft.spage=28&rft.epage=37&rft.pages=28-37&rft.issn=0741-5214&rft.eissn=1097-6809&rft_id=info:doi/10.1016/j.jvs.2020.11.046&rft_dat=%3Cproquest_pubme%3E2471456809%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2471456809&rft_id=info:pmid/33340701&rft_els_id=S0741521420325945&rfr_iscdi=true