Stimulation Rate and Voice Pitch Perception in Cochlear Implants
The stimulation rate in cochlear implant (CI) sound coding, or the “carrier” rate in pulses per second (pps), is known to influence pitch perception, as well as loudness perception and sound quality. Our main objective was to investigate the effects of reduced carrier rate on the loudness and pitch...
Gespeichert in:
Veröffentlicht in: | Journal of the Association for Research in Otolaryngology 2022-10, Vol.23 (5), p.665-680 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 680 |
---|---|
container_issue | 5 |
container_start_page | 665 |
container_title | Journal of the Association for Research in Otolaryngology |
container_volume | 23 |
creator | Kovačić, Damir James, Chris J. |
description | The stimulation rate in cochlear implant (CI) sound coding, or the “carrier” rate in pulses per second (pps), is known to influence pitch perception, as well as loudness perception and sound quality. Our main objective was to investigate the effects of reduced carrier rate on the loudness and pitch of coded speech samples. We describe two experiments with 16 Nucleus® CI users, where we controlled modulation characteristics and carrier rate using Spectral and Temporal Enhanced Processing (STEP), a novel experimental multichannel sound coder. We used a fixed set of threshold and comfortable stimulation levels for each subject, obtained from clinical MAPs. In the first experiment, we determined equivalence for voice pitch ranking and voice gender categorization between the Advanced Combination Encoder (ACE), a widely used clinical strategy in Nucleus® recipients, and STEP for fundamental frequencies (F0) 120–250 Hz. In the second experiment, loudness was determined as a function of the input amplitude of speech samples for carrier rates of 1000, 500, and 250 pps per channel. Then, using equally loud sound coder programs, we evaluated the effect of carrier rate on voice pitch perception. Although nearly all subjects could categorize voice gender significantly above chance, pitch ranking varied across subjects. Overall, carrier rate did not substantially affect voice pitch ranking or voice gender categorization: as long as the carrier rate was at least twice the fundamental frequency, or when stimulation pulses for the lowest, 250 pps carrier were aligned to F0 peaks. These results indicate that carrier rates as low as 250 pps per channel are sufficient to support functional voice pitch perception for those CI users sensitive to temporal pitch cues; at least when temporal modulations and pulse timings in the coder output are well controlled by novel strategies such as STEP. |
doi_str_mv | 10.1007/s10162-022-00854-2 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9613839</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2729558589</sourcerecordid><originalsourceid>FETCH-LOGICAL-c402t-aeb537d545b40c42b4599e9a145d6ad19cdc10a10dfff5306878c06251dde69e3</originalsourceid><addsrcrecordid>eNp9kUlLBDEQhYMo7n_AU4MXL61ZOknnIsrgBoKD2zVkkmonQ3dnTLoF_709zuB28FBUQb33UcVD6IDgY4KxPEkEE0FzTIfCJS9yuoa2ScHKXHLJ1n_MW2gnpRnGRHKhNtEW44qUHJNtdPbQ-aavTedDm92bDjLTuuw5eAvZ2Hd2mo0hWph_7n2bjYKd1mBidtPMa9N2aQ9tVKZOsL_qu-jp8uJxdJ3f3l3djM5vc1tg2uUGJpxJxws-KbAt6KTgSoEypOBOGEeUdZZgQ7CrqoozLEpZWiwoJ86BUMB20emSO-8nDTgLbRdNrefRNya-62C8_r1p_VS_hDetBGElUwPgaAWI4bWH1OnGJwv18AWEPmkqlBSSMiIH6eEf6Sz0sR3e01RSxXnJywWQLlU2hpQiVF_HEKwXAellQHoISH8GpOlgYktTGsTtC8Rv9D-uD8QbkXI</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2729558589</pqid></control><display><type>article</type><title>Stimulation Rate and Voice Pitch Perception in Cochlear Implants</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>SpringerNature Journals</source><source>PubMed Central</source><creator>Kovačić, Damir ; James, Chris J.</creator><creatorcontrib>Kovačić, Damir ; James, Chris J.</creatorcontrib><description>The stimulation rate in cochlear implant (CI) sound coding, or the “carrier” rate in pulses per second (pps), is known to influence pitch perception, as well as loudness perception and sound quality. Our main objective was to investigate the effects of reduced carrier rate on the loudness and pitch of coded speech samples. We describe two experiments with 16 Nucleus® CI users, where we controlled modulation characteristics and carrier rate using Spectral and Temporal Enhanced Processing (STEP), a novel experimental multichannel sound coder. We used a fixed set of threshold and comfortable stimulation levels for each subject, obtained from clinical MAPs. In the first experiment, we determined equivalence for voice pitch ranking and voice gender categorization between the Advanced Combination Encoder (ACE), a widely used clinical strategy in Nucleus® recipients, and STEP for fundamental frequencies (F0) 120–250 Hz. In the second experiment, loudness was determined as a function of the input amplitude of speech samples for carrier rates of 1000, 500, and 250 pps per channel. Then, using equally loud sound coder programs, we evaluated the effect of carrier rate on voice pitch perception. Although nearly all subjects could categorize voice gender significantly above chance, pitch ranking varied across subjects. Overall, carrier rate did not substantially affect voice pitch ranking or voice gender categorization: as long as the carrier rate was at least twice the fundamental frequency, or when stimulation pulses for the lowest, 250 pps carrier were aligned to F0 peaks. These results indicate that carrier rates as low as 250 pps per channel are sufficient to support functional voice pitch perception for those CI users sensitive to temporal pitch cues; at least when temporal modulations and pulse timings in the coder output are well controlled by novel strategies such as STEP.</description><identifier>ISSN: 1438-7573</identifier><identifier>ISSN: 1525-3961</identifier><identifier>EISSN: 1438-7573</identifier><identifier>DOI: 10.1007/s10162-022-00854-2</identifier><identifier>PMID: 35918501</identifier><language>eng</language><publisher>New York: Springer US</publisher><subject>Cochlea ; Cochlear implants ; Frequency ; Gender ; Information processing ; Medicine ; Medicine & Public Health ; Neurobiology ; Neurosciences ; Otorhinolaryngology ; Research Article ; Sound ; Speech ; Speech perception ; Transplants & implants</subject><ispartof>Journal of the Association for Research in Otolaryngology, 2022-10, Vol.23 (5), p.665-680</ispartof><rights>The Author(s) under exclusive licence to Association for Research in Otolaryngology 2022</rights><rights>The Author(s) under exclusive licence to Association for Research in Otolaryngology 2022.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c402t-aeb537d545b40c42b4599e9a145d6ad19cdc10a10dfff5306878c06251dde69e3</cites><orcidid>0000-0002-1007-3735</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC9613839/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC9613839/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,315,729,782,786,887,27933,27934,41497,42566,51328,53800,53802</link.rule.ids></links><search><creatorcontrib>Kovačić, Damir</creatorcontrib><creatorcontrib>James, Chris J.</creatorcontrib><title>Stimulation Rate and Voice Pitch Perception in Cochlear Implants</title><title>Journal of the Association for Research in Otolaryngology</title><addtitle>JARO</addtitle><description>The stimulation rate in cochlear implant (CI) sound coding, or the “carrier” rate in pulses per second (pps), is known to influence pitch perception, as well as loudness perception and sound quality. Our main objective was to investigate the effects of reduced carrier rate on the loudness and pitch of coded speech samples. We describe two experiments with 16 Nucleus® CI users, where we controlled modulation characteristics and carrier rate using Spectral and Temporal Enhanced Processing (STEP), a novel experimental multichannel sound coder. We used a fixed set of threshold and comfortable stimulation levels for each subject, obtained from clinical MAPs. In the first experiment, we determined equivalence for voice pitch ranking and voice gender categorization between the Advanced Combination Encoder (ACE), a widely used clinical strategy in Nucleus® recipients, and STEP for fundamental frequencies (F0) 120–250 Hz. In the second experiment, loudness was determined as a function of the input amplitude of speech samples for carrier rates of 1000, 500, and 250 pps per channel. Then, using equally loud sound coder programs, we evaluated the effect of carrier rate on voice pitch perception. Although nearly all subjects could categorize voice gender significantly above chance, pitch ranking varied across subjects. Overall, carrier rate did not substantially affect voice pitch ranking or voice gender categorization: as long as the carrier rate was at least twice the fundamental frequency, or when stimulation pulses for the lowest, 250 pps carrier were aligned to F0 peaks. These results indicate that carrier rates as low as 250 pps per channel are sufficient to support functional voice pitch perception for those CI users sensitive to temporal pitch cues; at least when temporal modulations and pulse timings in the coder output are well controlled by novel strategies such as STEP.</description><subject>Cochlea</subject><subject>Cochlear implants</subject><subject>Frequency</subject><subject>Gender</subject><subject>Information processing</subject><subject>Medicine</subject><subject>Medicine & Public Health</subject><subject>Neurobiology</subject><subject>Neurosciences</subject><subject>Otorhinolaryngology</subject><subject>Research Article</subject><subject>Sound</subject><subject>Speech</subject><subject>Speech perception</subject><subject>Transplants & implants</subject><issn>1438-7573</issn><issn>1525-3961</issn><issn>1438-7573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kUlLBDEQhYMo7n_AU4MXL61ZOknnIsrgBoKD2zVkkmonQ3dnTLoF_709zuB28FBUQb33UcVD6IDgY4KxPEkEE0FzTIfCJS9yuoa2ScHKXHLJ1n_MW2gnpRnGRHKhNtEW44qUHJNtdPbQ-aavTedDm92bDjLTuuw5eAvZ2Hd2mo0hWph_7n2bjYKd1mBidtPMa9N2aQ9tVKZOsL_qu-jp8uJxdJ3f3l3djM5vc1tg2uUGJpxJxws-KbAt6KTgSoEypOBOGEeUdZZgQ7CrqoozLEpZWiwoJ86BUMB20emSO-8nDTgLbRdNrefRNya-62C8_r1p_VS_hDetBGElUwPgaAWI4bWH1OnGJwv18AWEPmkqlBSSMiIH6eEf6Sz0sR3e01RSxXnJywWQLlU2hpQiVF_HEKwXAellQHoISH8GpOlgYktTGsTtC8Rv9D-uD8QbkXI</recordid><startdate>20221001</startdate><enddate>20221001</enddate><creator>Kovačić, Damir</creator><creator>James, Chris J.</creator><general>Springer US</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TK</scope><scope>K9.</scope><scope>NAPCQ</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-1007-3735</orcidid></search><sort><creationdate>20221001</creationdate><title>Stimulation Rate and Voice Pitch Perception in Cochlear Implants</title><author>Kovačić, Damir ; James, Chris J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c402t-aeb537d545b40c42b4599e9a145d6ad19cdc10a10dfff5306878c06251dde69e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Cochlea</topic><topic>Cochlear implants</topic><topic>Frequency</topic><topic>Gender</topic><topic>Information processing</topic><topic>Medicine</topic><topic>Medicine & Public Health</topic><topic>Neurobiology</topic><topic>Neurosciences</topic><topic>Otorhinolaryngology</topic><topic>Research Article</topic><topic>Sound</topic><topic>Speech</topic><topic>Speech perception</topic><topic>Transplants & implants</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kovačić, Damir</creatorcontrib><creatorcontrib>James, Chris J.</creatorcontrib><collection>CrossRef</collection><collection>Neurosciences Abstracts</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Premium</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of the Association for Research in Otolaryngology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kovačić, Damir</au><au>James, Chris J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Stimulation Rate and Voice Pitch Perception in Cochlear Implants</atitle><jtitle>Journal of the Association for Research in Otolaryngology</jtitle><stitle>JARO</stitle><date>2022-10-01</date><risdate>2022</risdate><volume>23</volume><issue>5</issue><spage>665</spage><epage>680</epage><pages>665-680</pages><issn>1438-7573</issn><issn>1525-3961</issn><eissn>1438-7573</eissn><abstract>The stimulation rate in cochlear implant (CI) sound coding, or the “carrier” rate in pulses per second (pps), is known to influence pitch perception, as well as loudness perception and sound quality. Our main objective was to investigate the effects of reduced carrier rate on the loudness and pitch of coded speech samples. We describe two experiments with 16 Nucleus® CI users, where we controlled modulation characteristics and carrier rate using Spectral and Temporal Enhanced Processing (STEP), a novel experimental multichannel sound coder. We used a fixed set of threshold and comfortable stimulation levels for each subject, obtained from clinical MAPs. In the first experiment, we determined equivalence for voice pitch ranking and voice gender categorization between the Advanced Combination Encoder (ACE), a widely used clinical strategy in Nucleus® recipients, and STEP for fundamental frequencies (F0) 120–250 Hz. In the second experiment, loudness was determined as a function of the input amplitude of speech samples for carrier rates of 1000, 500, and 250 pps per channel. Then, using equally loud sound coder programs, we evaluated the effect of carrier rate on voice pitch perception. Although nearly all subjects could categorize voice gender significantly above chance, pitch ranking varied across subjects. Overall, carrier rate did not substantially affect voice pitch ranking or voice gender categorization: as long as the carrier rate was at least twice the fundamental frequency, or when stimulation pulses for the lowest, 250 pps carrier were aligned to F0 peaks. These results indicate that carrier rates as low as 250 pps per channel are sufficient to support functional voice pitch perception for those CI users sensitive to temporal pitch cues; at least when temporal modulations and pulse timings in the coder output are well controlled by novel strategies such as STEP.</abstract><cop>New York</cop><pub>Springer US</pub><pmid>35918501</pmid><doi>10.1007/s10162-022-00854-2</doi><tpages>16</tpages><orcidid>https://orcid.org/0000-0002-1007-3735</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1438-7573 |
ispartof | Journal of the Association for Research in Otolaryngology, 2022-10, Vol.23 (5), p.665-680 |
issn | 1438-7573 1525-3961 1438-7573 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9613839 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; SpringerNature Journals; PubMed Central |
subjects | Cochlea Cochlear implants Frequency Gender Information processing Medicine Medicine & Public Health Neurobiology Neurosciences Otorhinolaryngology Research Article Sound Speech Speech perception Transplants & implants |
title | Stimulation Rate and Voice Pitch Perception in Cochlear Implants |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-11-30T08%3A48%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Stimulation%20Rate%20and%20Voice%20Pitch%20Perception%20in%20Cochlear%20Implants&rft.jtitle=Journal%20of%20the%20Association%20for%20Research%20in%20Otolaryngology&rft.au=Kova%C4%8Di%C4%87,%20Damir&rft.date=2022-10-01&rft.volume=23&rft.issue=5&rft.spage=665&rft.epage=680&rft.pages=665-680&rft.issn=1438-7573&rft.eissn=1438-7573&rft_id=info:doi/10.1007/s10162-022-00854-2&rft_dat=%3Cproquest_pubme%3E2729558589%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2729558589&rft_id=info:pmid/35918501&rfr_iscdi=true |