Diagnostic Performance of Optical Coherence Tomography and Nonspecialist Gonioscopy to Detect Angle Closure
AimTo compare the usefulness of gonioscopy performed by general ophthalmologists (GO) and anterior segment optical coherence tomography (AS-OCT) in detecting angle closure in patients with a shallow anterior chamber. MethodsForty-four patients with a shallow anterior chamber (defined by a ratio of p...
Gespeichert in:
Veröffentlicht in: | Journal of current glaucoma practice 2022-01, Vol.16 (1), p.53-58 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | AimTo compare the usefulness of gonioscopy performed by general ophthalmologists (GO) and anterior segment optical coherence tomography (AS-OCT) in detecting angle closure in patients with a shallow anterior chamber. MethodsForty-four patients with a shallow anterior chamber (defined by a ratio of peripheral anterior chamber depth to peripheral corneal thickness lower than 1/2) were included in this cross-sectional study. Gonioscopy was performed in all subjects by two glaucoma experts (GE1 and GE2) and one GO. Anterior segment imaging was performed using Visante® OCT (Carl Zeiss Meditec Inc.). Agreement between examiners was assessed with first-order agreement coefficients (AC1). Diagnostic accuracies of GO gonioscopy and AS-OCT were evaluated using sensitivity, specificity, and area under the receiver operating characteristic (AROC) curves. ResultsFor static gonioscopy, the agreement between GE1 and GE2 was substantial (AC1 = 0.65), and that between GE1 and GO was moderate (AC1 = 0.50). For indentation gonioscopy, the agreement between GE1 and GE2 was slightly lower (AC1 = 0.55); however, the agreement between GE1 and GO showed a larger reduction (AC1 = 0.12). GO's gonioscopy presented a low specificity (25%) and the AROC to angle closure detection was lower than AS-OCT (0.56-0.73). Combined information of GO gonioscopy and AS-OCT improved specificity (85.7%) and AROC (0.77) of angle closure evaluation. ConclusionAgreement between GO and glaucoma experts was moderate for static gonioscopy and slight for indentation gonioscopy. AS-OCT performed better than GO gonioscopy in detecting angle closure in patients with a shallow anterior chamber. The addition of AS-OCT to clinical information in patients with GO positive gonioscopy improved the specificity and AROC of gonioscopy test. How to cite this articleEsporcatte BLB, Vessani RM, Melo Jr LAS, et al. Diagnostic Performance of Optical Coherence Tomography and Nonspecialist Gonioscopy to Detect Angle Closure. J Curr Glaucoma Pract 2022;16(1):53-58. |
---|---|
ISSN: | 0974-0333 0975-1947 |
DOI: | 10.5005/jp-journals-10078-1354 |