Syndesmosis screw breakage: An analysis of multiple breakage locations
Concerns have been raised about screw breakage within the tibia or fibula, referred to as intraosseous breakage. The purpose of this investigation is to analyze the technical aspects of syndesmotic screw placement in multiple anatomic breakage locations. A retrospective analysis of over 1056 patient...
Gespeichert in:
Veröffentlicht in: | Journal of orthopaedics 2022-01, Vol.29, p.38-43 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 43 |
---|---|
container_issue | |
container_start_page | 38 |
container_title | Journal of orthopaedics |
container_volume | 29 |
creator | Vander Maten, Josh W. McCracken, Matthew Liu, Jiayong Ebraheim, Nabil A. |
description | Concerns have been raised about screw breakage within the tibia or fibula, referred to as intraosseous breakage. The purpose of this investigation is to analyze the technical aspects of syndesmotic screw placement in multiple anatomic breakage locations.
A retrospective analysis of over 1056 patients who underwent syndesmosis fixation was completed. Demographics, screw length, width, number, height above the tibial plafond, angle, breakage location, and breakage location on the screw were collected and analyzed.
Intraosseous (IO) screw breakage (91 screws, 68 patients) was more common than clear space (CS) breakage (28 screws, 18 patients) (P = |
doi_str_mv | 10.1016/j.jor.2022.01.004 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8801966</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0972978X22000046</els_id><sourcerecordid>2628670412</sourcerecordid><originalsourceid>FETCH-LOGICAL-c451t-2f609c05cf29f5b1a5e439ea51136b916f124002bce777f98d3213e622a147573</originalsourceid><addsrcrecordid>eNp9kMFO3DAQhq2qFUuBB-gF5djLhhk7duJWQkIIWiQkDrQSN8txJlsvSbzYWdC-fbNauoJLTzPSfPPP6GPsC0KOgOpsmS9DzDlwngPmAMUHdgi65HNdVg8f3_Qz9jmlJYDgUokDNhMSpShQH7Lr-83QUOpD8ilLLtJLVkeyj3ZB37KLIbOD7TbbWWizft2NftXRnsi64Ozow5CO2afWdolOXusR-3199evy5_z27sfN5cXt3BUSxzlvFWgH0rVct7JGK6kQmqxEFKrWqFrkBQCvHZVl2eqqERwFKc4tFqUsxRE73-Wu1nVPjaNhjLYzq-h7GzcmWG_eTwb_xyzCs6kqQK3UFPD1NSCGpzWl0fQ-Oeo6O1BYJ8MVr1QJBfIJxR3qYkgpUrs_g2C2_s3STP7N1r8BNJP_aef07X_7jX_CJ-D7DqDJ0rOnaJLzNDhqfCQ3mib4_8T_BWjNlqw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2628670412</pqid></control><display><type>article</type><title>Syndesmosis screw breakage: An analysis of multiple breakage locations</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Vander Maten, Josh W. ; McCracken, Matthew ; Liu, Jiayong ; Ebraheim, Nabil A.</creator><creatorcontrib>Vander Maten, Josh W. ; McCracken, Matthew ; Liu, Jiayong ; Ebraheim, Nabil A.</creatorcontrib><description>Concerns have been raised about screw breakage within the tibia or fibula, referred to as intraosseous breakage. The purpose of this investigation is to analyze the technical aspects of syndesmotic screw placement in multiple anatomic breakage locations.
A retrospective analysis of over 1056 patients who underwent syndesmosis fixation was completed. Demographics, screw length, width, number, height above the tibial plafond, angle, breakage location, and breakage location on the screw were collected and analyzed.
Intraosseous (IO) screw breakage (91 screws, 68 patients) was more common than clear space (CS) breakage (28 screws, 18 patients) (P = < 0.001). Within the IO group, screw breakage within the tibia (60 screws, 52 patients) was more common compared to fibula breakage (29 screws, 24 patients) (P = < 0.001).
Increased BMI and the use of multiple screws were associated with IO breakage (P = .007) and CS breakage (P = .012), respectively. Increased screw angle and age were associated with fibular IO breakage (P = .021, P = .036) when compared to other IO breakage locations. Screw angle and placement showed no significant differences between compared groups (P = .629, P = .570).
Syndesmosis screw breakage, overall, occurred more commonly in an IO location. When compared to IO breakage, the use of multiple syndesmosis screws is most associated with CS breakage. Increased BMI is associated with increased IO breakage when compared to CS breakage. Patients with IO screw breakage within the fibula had increased age and placed at a higher angle when compared to other IO breakage locations. No other factors related to screw placement, including the height of placement, were found to be significantly associated with location of screw breakage.
•Syndesmosis screw breakage, overall, occurred more commonly in an IO location.•When compared to IO breakage, the use of multiple syndesmosis screws is most associated with CS breakage.•Increased BMI is associated with increased IO breakage when compared to CS breakage.•Patients with IO screw breakage within the fibula had increased age and placed at a higher angle.•No other factors related to screw placement were found to be significantly associated with location of screw breakage.</description><identifier>ISSN: 0972-978X</identifier><identifier>EISSN: 0972-978X</identifier><identifier>DOI: 10.1016/j.jor.2022.01.004</identifier><identifier>PMID: 35153419</identifier><language>eng</language><publisher>India: Elsevier B.V</publisher><subject>Breakage ; Clear space ; Intraosseous ; Screw ; Syndesmosis</subject><ispartof>Journal of orthopaedics, 2022-01, Vol.29, p.38-43</ispartof><rights>2022 Professor P K Surendran Memorial Education Foundation</rights><rights>2022 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved.</rights><rights>2022 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved. 2022 Professor P K Surendran Memorial Education Foundation</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c451t-2f609c05cf29f5b1a5e439ea51136b916f124002bce777f98d3213e622a147573</citedby><cites>FETCH-LOGICAL-c451t-2f609c05cf29f5b1a5e439ea51136b916f124002bce777f98d3213e622a147573</cites><orcidid>0000-0002-5895-8276 ; 0000-0002-7395-3246</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8801966/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8801966/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,724,777,781,882,27905,27906,53772,53774</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35153419$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Vander Maten, Josh W.</creatorcontrib><creatorcontrib>McCracken, Matthew</creatorcontrib><creatorcontrib>Liu, Jiayong</creatorcontrib><creatorcontrib>Ebraheim, Nabil A.</creatorcontrib><title>Syndesmosis screw breakage: An analysis of multiple breakage locations</title><title>Journal of orthopaedics</title><addtitle>J Orthop</addtitle><description>Concerns have been raised about screw breakage within the tibia or fibula, referred to as intraosseous breakage. The purpose of this investigation is to analyze the technical aspects of syndesmotic screw placement in multiple anatomic breakage locations.
A retrospective analysis of over 1056 patients who underwent syndesmosis fixation was completed. Demographics, screw length, width, number, height above the tibial plafond, angle, breakage location, and breakage location on the screw were collected and analyzed.
Intraosseous (IO) screw breakage (91 screws, 68 patients) was more common than clear space (CS) breakage (28 screws, 18 patients) (P = < 0.001). Within the IO group, screw breakage within the tibia (60 screws, 52 patients) was more common compared to fibula breakage (29 screws, 24 patients) (P = < 0.001).
Increased BMI and the use of multiple screws were associated with IO breakage (P = .007) and CS breakage (P = .012), respectively. Increased screw angle and age were associated with fibular IO breakage (P = .021, P = .036) when compared to other IO breakage locations. Screw angle and placement showed no significant differences between compared groups (P = .629, P = .570).
Syndesmosis screw breakage, overall, occurred more commonly in an IO location. When compared to IO breakage, the use of multiple syndesmosis screws is most associated with CS breakage. Increased BMI is associated with increased IO breakage when compared to CS breakage. Patients with IO screw breakage within the fibula had increased age and placed at a higher angle when compared to other IO breakage locations. No other factors related to screw placement, including the height of placement, were found to be significantly associated with location of screw breakage.
•Syndesmosis screw breakage, overall, occurred more commonly in an IO location.•When compared to IO breakage, the use of multiple syndesmosis screws is most associated with CS breakage.•Increased BMI is associated with increased IO breakage when compared to CS breakage.•Patients with IO screw breakage within the fibula had increased age and placed at a higher angle.•No other factors related to screw placement were found to be significantly associated with location of screw breakage.</description><subject>Breakage</subject><subject>Clear space</subject><subject>Intraosseous</subject><subject>Screw</subject><subject>Syndesmosis</subject><issn>0972-978X</issn><issn>0972-978X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kMFO3DAQhq2qFUuBB-gF5djLhhk7duJWQkIIWiQkDrQSN8txJlsvSbzYWdC-fbNauoJLTzPSfPPP6GPsC0KOgOpsmS9DzDlwngPmAMUHdgi65HNdVg8f3_Qz9jmlJYDgUokDNhMSpShQH7Lr-83QUOpD8ilLLtJLVkeyj3ZB37KLIbOD7TbbWWizft2NftXRnsi64Ozow5CO2afWdolOXusR-3199evy5_z27sfN5cXt3BUSxzlvFWgH0rVct7JGK6kQmqxEFKrWqFrkBQCvHZVl2eqqERwFKc4tFqUsxRE73-Wu1nVPjaNhjLYzq-h7GzcmWG_eTwb_xyzCs6kqQK3UFPD1NSCGpzWl0fQ-Oeo6O1BYJ8MVr1QJBfIJxR3qYkgpUrs_g2C2_s3STP7N1r8BNJP_aef07X_7jX_CJ-D7DqDJ0rOnaJLzNDhqfCQ3mib4_8T_BWjNlqw</recordid><startdate>20220101</startdate><enddate>20220101</enddate><creator>Vander Maten, Josh W.</creator><creator>McCracken, Matthew</creator><creator>Liu, Jiayong</creator><creator>Ebraheim, Nabil A.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-5895-8276</orcidid><orcidid>https://orcid.org/0000-0002-7395-3246</orcidid></search><sort><creationdate>20220101</creationdate><title>Syndesmosis screw breakage: An analysis of multiple breakage locations</title><author>Vander Maten, Josh W. ; McCracken, Matthew ; Liu, Jiayong ; Ebraheim, Nabil A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c451t-2f609c05cf29f5b1a5e439ea51136b916f124002bce777f98d3213e622a147573</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Breakage</topic><topic>Clear space</topic><topic>Intraosseous</topic><topic>Screw</topic><topic>Syndesmosis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vander Maten, Josh W.</creatorcontrib><creatorcontrib>McCracken, Matthew</creatorcontrib><creatorcontrib>Liu, Jiayong</creatorcontrib><creatorcontrib>Ebraheim, Nabil A.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of orthopaedics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vander Maten, Josh W.</au><au>McCracken, Matthew</au><au>Liu, Jiayong</au><au>Ebraheim, Nabil A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Syndesmosis screw breakage: An analysis of multiple breakage locations</atitle><jtitle>Journal of orthopaedics</jtitle><addtitle>J Orthop</addtitle><date>2022-01-01</date><risdate>2022</risdate><volume>29</volume><spage>38</spage><epage>43</epage><pages>38-43</pages><issn>0972-978X</issn><eissn>0972-978X</eissn><abstract>Concerns have been raised about screw breakage within the tibia or fibula, referred to as intraosseous breakage. The purpose of this investigation is to analyze the technical aspects of syndesmotic screw placement in multiple anatomic breakage locations.
A retrospective analysis of over 1056 patients who underwent syndesmosis fixation was completed. Demographics, screw length, width, number, height above the tibial plafond, angle, breakage location, and breakage location on the screw were collected and analyzed.
Intraosseous (IO) screw breakage (91 screws, 68 patients) was more common than clear space (CS) breakage (28 screws, 18 patients) (P = < 0.001). Within the IO group, screw breakage within the tibia (60 screws, 52 patients) was more common compared to fibula breakage (29 screws, 24 patients) (P = < 0.001).
Increased BMI and the use of multiple screws were associated with IO breakage (P = .007) and CS breakage (P = .012), respectively. Increased screw angle and age were associated with fibular IO breakage (P = .021, P = .036) when compared to other IO breakage locations. Screw angle and placement showed no significant differences between compared groups (P = .629, P = .570).
Syndesmosis screw breakage, overall, occurred more commonly in an IO location. When compared to IO breakage, the use of multiple syndesmosis screws is most associated with CS breakage. Increased BMI is associated with increased IO breakage when compared to CS breakage. Patients with IO screw breakage within the fibula had increased age and placed at a higher angle when compared to other IO breakage locations. No other factors related to screw placement, including the height of placement, were found to be significantly associated with location of screw breakage.
•Syndesmosis screw breakage, overall, occurred more commonly in an IO location.•When compared to IO breakage, the use of multiple syndesmosis screws is most associated with CS breakage.•Increased BMI is associated with increased IO breakage when compared to CS breakage.•Patients with IO screw breakage within the fibula had increased age and placed at a higher angle.•No other factors related to screw placement were found to be significantly associated with location of screw breakage.</abstract><cop>India</cop><pub>Elsevier B.V</pub><pmid>35153419</pmid><doi>10.1016/j.jor.2022.01.004</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0002-5895-8276</orcidid><orcidid>https://orcid.org/0000-0002-7395-3246</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0972-978X |
ispartof | Journal of orthopaedics, 2022-01, Vol.29, p.38-43 |
issn | 0972-978X 0972-978X |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8801966 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central; Alma/SFX Local Collection |
subjects | Breakage Clear space Intraosseous Screw Syndesmosis |
title | Syndesmosis screw breakage: An analysis of multiple breakage locations |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T12%3A31%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Syndesmosis%20screw%20breakage:%20An%20analysis%20of%20multiple%20breakage%20locations&rft.jtitle=Journal%20of%20orthopaedics&rft.au=Vander%20Maten,%20Josh%20W.&rft.date=2022-01-01&rft.volume=29&rft.spage=38&rft.epage=43&rft.pages=38-43&rft.issn=0972-978X&rft.eissn=0972-978X&rft_id=info:doi/10.1016/j.jor.2022.01.004&rft_dat=%3Cproquest_pubme%3E2628670412%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2628670412&rft_id=info:pmid/35153419&rft_els_id=S0972978X22000046&rfr_iscdi=true |