Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report

Fibrotic hypersensitivity pneumonitis (FHP) is an allergic and diffuse pneumonia caused by repeated inhalation of antigenic substances, and sometimes developed in people working in specific environments. While novel antigens and exposures continued to be described, physicians should maintain a high...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:World journal of clinical cases 2022-01, Vol.10 (2), p.741-746
Hauptverfasser: Wang, Min, Fang, Hao-Hui, Jiang, Zi-Feng, Ye, Wei, Liu, Rong-Yu
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 746
container_issue 2
container_start_page 741
container_title World journal of clinical cases
container_volume 10
creator Wang, Min
Fang, Hao-Hui
Jiang, Zi-Feng
Ye, Wei
Liu, Rong-Yu
description Fibrotic hypersensitivity pneumonitis (FHP) is an allergic and diffuse pneumonia caused by repeated inhalation of antigenic substances, and sometimes developed in people working in specific environments. While novel antigens and exposures continued to be described, physicians should maintain a high suspicion of potential exposures. A detailed assessment of the patient's occupational exposures as well as living environment is necessary and complete allergen avoidance is the first and most important step in the management of FHP once the allergens are determined. A 35-year-old female was admitted to the hospital with a cough and breathing difficulties for more than one year. She was a nonsmoker and a manufacturer of halogen dishes, which are characteristic Chinese foods, for 15 years without any protection. High resolution computed tomography of the chest demonstrated an interstitial pneumonia pattern. Pulmonary function examination showed restricted ventilation dysfunction and a significant reduction in dispersion ability. Cell differentiation in bronchoalveolar lavage fluid demonstrated lymphocytosis (70.4%) with an increased lymphocyte CD4/CD8 ratio (0.94). Transbronchial lung biopsy combined with lung puncture pathology showed diffuse uniform alveolar interval thickening, chronic inflammatory cell infiltration, a proliferation of tissue in the bronchial wall fiber and alveolar epithelial follicle degeneration, resulting in fibrosis. Exposure to spices used for the production of halogen dishes may cause FHP.
doi_str_mv 10.12998/wjcc.v10.i2.741
format Article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8771394</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>35097102</sourcerecordid><originalsourceid>FETCH-LOGICAL-c316t-c1d5616b6a4b25c4a11f13a24e3ea87178876133498b8b1568aafe8724da92403</originalsourceid><addsrcrecordid>eNpVkE1LAzEQhoMottTePUn-QGsm2d1kPQil-AWFXvQcZ7PZNqXNLslupf_e1arU08zw8rwDDyHXwKbA81zdfmyMme770_GpTOCMDLlgcqLyjJ2f7AMyjnHDGANgKWTikgxEynIJjA_J-9KYrsHW1R63tHJFqFtn6PrQ2BCtj651e9ceaONtt6u9Q-o8RbrGbb2ynpYurm2kO_Rdhabtgg13dEYNRkuDberQXpGLCrfRjn_miLw9PrzOnyeL5dPLfLaYGAFZOzFQphlkRYZJwVOTIEAFAnlihUUlQSolMxAiyVWhCkgzhVhZJXlSYs4TJkbk_tjbdMXOlsb6NuBWN8HtMBx0jU7_T7xb61W910pKEHnSF7BjgQl1jMFWfyww_S1cfwnXvXDtuO6F98jN6c8_4Fev-ATX_oAm</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report</title><source>Baishideng "World Journal of" online journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><creator>Wang, Min ; Fang, Hao-Hui ; Jiang, Zi-Feng ; Ye, Wei ; Liu, Rong-Yu</creator><creatorcontrib>Wang, Min ; Fang, Hao-Hui ; Jiang, Zi-Feng ; Ye, Wei ; Liu, Rong-Yu</creatorcontrib><description>Fibrotic hypersensitivity pneumonitis (FHP) is an allergic and diffuse pneumonia caused by repeated inhalation of antigenic substances, and sometimes developed in people working in specific environments. While novel antigens and exposures continued to be described, physicians should maintain a high suspicion of potential exposures. A detailed assessment of the patient's occupational exposures as well as living environment is necessary and complete allergen avoidance is the first and most important step in the management of FHP once the allergens are determined. A 35-year-old female was admitted to the hospital with a cough and breathing difficulties for more than one year. She was a nonsmoker and a manufacturer of halogen dishes, which are characteristic Chinese foods, for 15 years without any protection. High resolution computed tomography of the chest demonstrated an interstitial pneumonia pattern. Pulmonary function examination showed restricted ventilation dysfunction and a significant reduction in dispersion ability. Cell differentiation in bronchoalveolar lavage fluid demonstrated lymphocytosis (70.4%) with an increased lymphocyte CD4/CD8 ratio (0.94). Transbronchial lung biopsy combined with lung puncture pathology showed diffuse uniform alveolar interval thickening, chronic inflammatory cell infiltration, a proliferation of tissue in the bronchial wall fiber and alveolar epithelial follicle degeneration, resulting in fibrosis. Exposure to spices used for the production of halogen dishes may cause FHP.</description><identifier>ISSN: 2307-8960</identifier><identifier>EISSN: 2307-8960</identifier><identifier>DOI: 10.12998/wjcc.v10.i2.741</identifier><identifier>PMID: 35097102</identifier><language>eng</language><publisher>United States: Baishideng Publishing Group Inc</publisher><subject>Case Report</subject><ispartof>World journal of clinical cases, 2022-01, Vol.10 (2), p.741-746</ispartof><rights>The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved.</rights><rights>The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved. 2021</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c316t-c1d5616b6a4b25c4a11f13a24e3ea87178876133498b8b1568aafe8724da92403</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8771394/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8771394/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,27903,27904,53769,53771</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35097102$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wang, Min</creatorcontrib><creatorcontrib>Fang, Hao-Hui</creatorcontrib><creatorcontrib>Jiang, Zi-Feng</creatorcontrib><creatorcontrib>Ye, Wei</creatorcontrib><creatorcontrib>Liu, Rong-Yu</creatorcontrib><title>Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report</title><title>World journal of clinical cases</title><addtitle>World J Clin Cases</addtitle><description>Fibrotic hypersensitivity pneumonitis (FHP) is an allergic and diffuse pneumonia caused by repeated inhalation of antigenic substances, and sometimes developed in people working in specific environments. While novel antigens and exposures continued to be described, physicians should maintain a high suspicion of potential exposures. A detailed assessment of the patient's occupational exposures as well as living environment is necessary and complete allergen avoidance is the first and most important step in the management of FHP once the allergens are determined. A 35-year-old female was admitted to the hospital with a cough and breathing difficulties for more than one year. She was a nonsmoker and a manufacturer of halogen dishes, which are characteristic Chinese foods, for 15 years without any protection. High resolution computed tomography of the chest demonstrated an interstitial pneumonia pattern. Pulmonary function examination showed restricted ventilation dysfunction and a significant reduction in dispersion ability. Cell differentiation in bronchoalveolar lavage fluid demonstrated lymphocytosis (70.4%) with an increased lymphocyte CD4/CD8 ratio (0.94). Transbronchial lung biopsy combined with lung puncture pathology showed diffuse uniform alveolar interval thickening, chronic inflammatory cell infiltration, a proliferation of tissue in the bronchial wall fiber and alveolar epithelial follicle degeneration, resulting in fibrosis. Exposure to spices used for the production of halogen dishes may cause FHP.</description><subject>Case Report</subject><issn>2307-8960</issn><issn>2307-8960</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNpVkE1LAzEQhoMottTePUn-QGsm2d1kPQil-AWFXvQcZ7PZNqXNLslupf_e1arU08zw8rwDDyHXwKbA81zdfmyMme770_GpTOCMDLlgcqLyjJ2f7AMyjnHDGANgKWTikgxEynIJjA_J-9KYrsHW1R63tHJFqFtn6PrQ2BCtj651e9ceaONtt6u9Q-o8RbrGbb2ynpYurm2kO_Rdhabtgg13dEYNRkuDberQXpGLCrfRjn_miLw9PrzOnyeL5dPLfLaYGAFZOzFQphlkRYZJwVOTIEAFAnlihUUlQSolMxAiyVWhCkgzhVhZJXlSYs4TJkbk_tjbdMXOlsb6NuBWN8HtMBx0jU7_T7xb61W910pKEHnSF7BjgQl1jMFWfyww_S1cfwnXvXDtuO6F98jN6c8_4Fev-ATX_oAm</recordid><startdate>20220114</startdate><enddate>20220114</enddate><creator>Wang, Min</creator><creator>Fang, Hao-Hui</creator><creator>Jiang, Zi-Feng</creator><creator>Ye, Wei</creator><creator>Liu, Rong-Yu</creator><general>Baishideng Publishing Group Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>5PM</scope></search><sort><creationdate>20220114</creationdate><title>Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report</title><author>Wang, Min ; Fang, Hao-Hui ; Jiang, Zi-Feng ; Ye, Wei ; Liu, Rong-Yu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c316t-c1d5616b6a4b25c4a11f13a24e3ea87178876133498b8b1568aafe8724da92403</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Case Report</topic><toplevel>online_resources</toplevel><creatorcontrib>Wang, Min</creatorcontrib><creatorcontrib>Fang, Hao-Hui</creatorcontrib><creatorcontrib>Jiang, Zi-Feng</creatorcontrib><creatorcontrib>Ye, Wei</creatorcontrib><creatorcontrib>Liu, Rong-Yu</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>World journal of clinical cases</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, Min</au><au>Fang, Hao-Hui</au><au>Jiang, Zi-Feng</au><au>Ye, Wei</au><au>Liu, Rong-Yu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report</atitle><jtitle>World journal of clinical cases</jtitle><addtitle>World J Clin Cases</addtitle><date>2022-01-14</date><risdate>2022</risdate><volume>10</volume><issue>2</issue><spage>741</spage><epage>746</epage><pages>741-746</pages><issn>2307-8960</issn><eissn>2307-8960</eissn><abstract>Fibrotic hypersensitivity pneumonitis (FHP) is an allergic and diffuse pneumonia caused by repeated inhalation of antigenic substances, and sometimes developed in people working in specific environments. While novel antigens and exposures continued to be described, physicians should maintain a high suspicion of potential exposures. A detailed assessment of the patient's occupational exposures as well as living environment is necessary and complete allergen avoidance is the first and most important step in the management of FHP once the allergens are determined. A 35-year-old female was admitted to the hospital with a cough and breathing difficulties for more than one year. She was a nonsmoker and a manufacturer of halogen dishes, which are characteristic Chinese foods, for 15 years without any protection. High resolution computed tomography of the chest demonstrated an interstitial pneumonia pattern. Pulmonary function examination showed restricted ventilation dysfunction and a significant reduction in dispersion ability. Cell differentiation in bronchoalveolar lavage fluid demonstrated lymphocytosis (70.4%) with an increased lymphocyte CD4/CD8 ratio (0.94). Transbronchial lung biopsy combined with lung puncture pathology showed diffuse uniform alveolar interval thickening, chronic inflammatory cell infiltration, a proliferation of tissue in the bronchial wall fiber and alveolar epithelial follicle degeneration, resulting in fibrosis. Exposure to spices used for the production of halogen dishes may cause FHP.</abstract><cop>United States</cop><pub>Baishideng Publishing Group Inc</pub><pmid>35097102</pmid><doi>10.12998/wjcc.v10.i2.741</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2307-8960
ispartof World journal of clinical cases, 2022-01, Vol.10 (2), p.741-746
issn 2307-8960
2307-8960
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8771394
source Baishideng "World Journal of" online journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central
subjects Case Report
title Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T06%3A29%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Occupational%20fibrotic%20hypersensitivity%20pneumonia%20in%20a%20halogen%20dishes%20manufacturer:%20A%20case%20report&rft.jtitle=World%20journal%20of%20clinical%20cases&rft.au=Wang,%20Min&rft.date=2022-01-14&rft.volume=10&rft.issue=2&rft.spage=741&rft.epage=746&rft.pages=741-746&rft.issn=2307-8960&rft.eissn=2307-8960&rft_id=info:doi/10.12998/wjcc.v10.i2.741&rft_dat=%3Cpubmed_cross%3E35097102%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/35097102&rfr_iscdi=true