Simultaneous Determination of the Five Constituents in Maiwei Dihuang Pills by the HPLC-DAD Method

Objective. The purpose of study is to establish an HPLC-DAD method for determination of the five constituents (deoxyschizandrin, γ-schizandrin, loganin, paeoniflorin, and paeonol) in Maiwei Dihuang Pills. Methods. An Agilent ZORBAX SB-C18 chromatographic column was carried out to determine the five...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Evidence-based complementary and alternative medicine 2021, Vol.2021, p.2536558-7
Hauptverfasser: Jia, Danchun, Cai, Hong, Ke, Yuan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 7
container_issue
container_start_page 2536558
container_title Evidence-based complementary and alternative medicine
container_volume 2021
creator Jia, Danchun
Cai, Hong
Ke, Yuan
description Objective. The purpose of study is to establish an HPLC-DAD method for determination of the five constituents (deoxyschizandrin, γ-schizandrin, loganin, paeoniflorin, and paeonol) in Maiwei Dihuang Pills. Methods. An Agilent ZORBAX SB-C18 chromatographic column was carried out to determine the five constituents of 50% methanol extract of Maiwei Dihuang Pills. Results. It was found the chromatographic peak resolution of each component in the study sample solution was 1.5 higher than that of other peaks and no peaks appeared in the blank control solution during the same time, suggesting specificity of HPLC-DAD was well established. The linearity test indicated that deoxyschizandrin, γ-schizandrin, loganin, paeoniflorin, and paeonol were 11.6–72.3 μg/mL, 6.4–45.2 μg/mL, 35.2–237.6 μg/mL, 18.1–114.2 μg/mL, and 32.2–215.3 μg/mL, respectively, suggesting each component has a good linear relationship within its own range. Additionally, the precision of HPLC-DAD was confirmed by a precision test; the stability of the study sample solution was confirmed by a stability test; and good reproducibility of HPLC-DAD was proved by a reproducible test. The recovery rate test showed that relative standard deviation (RSD) of recovery rate in deoxyschizandrin, γ-schizandrin, loganin, paeoniflorin, and paeonol was 100.26% (1.80%), 101.39% (1.74%), 101.19% (1.76%), 102.50% (1.65%), and 102.30% (1.58%), respectively. Conclusions. HPLC-DAD used to determine the five constituents in Maiwei Dihuang Pills, and it was easier and faster to operate, showing good condition in repeatability, precision, stability, and recovery, which is a great option for quality control.
doi_str_mv 10.1155/2021/2536558
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8433003</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2571758766</sourcerecordid><originalsourceid>FETCH-LOGICAL-c448t-7a0eb32d42b0bf93b73bf03f4702dc0aca9b3dbb1c32d1c3f32d3c5b0001f9e13</originalsourceid><addsrcrecordid>eNp9kU1LxDAQhoMoft88S8CLoNV8NJv2Isiuq8KKggreQtKmNtIm2qTK_nuz7rqoBy8zA_PMy8y8AOxhdIIxY6cEEXxKGB0wlq2ATcxTnKQky1aXNX_aAFvevyBEcs75OtigKcOEc7oJ1L1p-yZIq13v4UgH3bXGymCcha6CodZwbN41HDrrgwm9tsFDY-GNNB_awJGpe2mf4Z1pGg_V9Gvg6m4yTEbnI3ijQ-3KHbBWycbr3UXeBo_ji4fhVTK5vbwenk-SIk2zkHCJtKKkTIlCqsqp4lRViFYpR6QskCxkrmipFC4iFEMVEy2YQgjhKteYboOzue5rr1pdFnHVTjbitTOt7KbCSSN-d6ypxbN7F1lKKUI0ChwuBDr31msfRGt8oZtm_h1BGCcE54Msj-jBH_TF9Z2N580ozFnGB4NIHc-ponPed7paLoORmJknZuaJhXkR3_95wBL-disCR3OgNraUH-Z_uU_3cKHZ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2571758766</pqid></control><display><type>article</type><title>Simultaneous Determination of the Five Constituents in Maiwei Dihuang Pills by the HPLC-DAD Method</title><source>PubMed Central Open Access</source><source>Wiley-Blackwell Open Access Titles</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Jia, Danchun ; Cai, Hong ; Ke, Yuan</creator><contributor>Tan, Songwen ; Songwen Tan</contributor><creatorcontrib>Jia, Danchun ; Cai, Hong ; Ke, Yuan ; Tan, Songwen ; Songwen Tan</creatorcontrib><description>Objective. The purpose of study is to establish an HPLC-DAD method for determination of the five constituents (deoxyschizandrin, γ-schizandrin, loganin, paeoniflorin, and paeonol) in Maiwei Dihuang Pills. Methods. An Agilent ZORBAX SB-C18 chromatographic column was carried out to determine the five constituents of 50% methanol extract of Maiwei Dihuang Pills. Results. It was found the chromatographic peak resolution of each component in the study sample solution was 1.5 higher than that of other peaks and no peaks appeared in the blank control solution during the same time, suggesting specificity of HPLC-DAD was well established. The linearity test indicated that deoxyschizandrin, γ-schizandrin, loganin, paeoniflorin, and paeonol were 11.6–72.3 μg/mL, 6.4–45.2 μg/mL, 35.2–237.6 μg/mL, 18.1–114.2 μg/mL, and 32.2–215.3 μg/mL, respectively, suggesting each component has a good linear relationship within its own range. Additionally, the precision of HPLC-DAD was confirmed by a precision test; the stability of the study sample solution was confirmed by a stability test; and good reproducibility of HPLC-DAD was proved by a reproducible test. The recovery rate test showed that relative standard deviation (RSD) of recovery rate in deoxyschizandrin, γ-schizandrin, loganin, paeoniflorin, and paeonol was 100.26% (1.80%), 101.39% (1.74%), 101.19% (1.76%), 102.50% (1.65%), and 102.30% (1.58%), respectively. Conclusions. HPLC-DAD used to determine the five constituents in Maiwei Dihuang Pills, and it was easier and faster to operate, showing good condition in repeatability, precision, stability, and recovery, which is a great option for quality control.</description><identifier>ISSN: 1741-427X</identifier><identifier>EISSN: 1741-4288</identifier><identifier>DOI: 10.1155/2021/2536558</identifier><identifier>PMID: 34512773</identifier><language>eng</language><publisher>United States: Hindawi</publisher><subject>Chinese medicine ; Chromatography ; High-performance liquid chromatography ; Noise ; Quality control ; Sensors</subject><ispartof>Evidence-based complementary and alternative medicine, 2021, Vol.2021, p.2536558-7</ispartof><rights>Copyright © 2021 Danchun Jia et al.</rights><rights>Copyright © 2021 Danchun Jia et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. https://creativecommons.org/licenses/by/4.0</rights><rights>Copyright © 2021 Danchun Jia et al. 2021</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c448t-7a0eb32d42b0bf93b73bf03f4702dc0aca9b3dbb1c32d1c3f32d3c5b0001f9e13</citedby><cites>FETCH-LOGICAL-c448t-7a0eb32d42b0bf93b73bf03f4702dc0aca9b3dbb1c32d1c3f32d3c5b0001f9e13</cites><orcidid>0000-0001-8223-6831</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8433003/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8433003/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,4024,27923,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34512773$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><contributor>Tan, Songwen</contributor><contributor>Songwen Tan</contributor><creatorcontrib>Jia, Danchun</creatorcontrib><creatorcontrib>Cai, Hong</creatorcontrib><creatorcontrib>Ke, Yuan</creatorcontrib><title>Simultaneous Determination of the Five Constituents in Maiwei Dihuang Pills by the HPLC-DAD Method</title><title>Evidence-based complementary and alternative medicine</title><addtitle>Evid Based Complement Alternat Med</addtitle><description>Objective. The purpose of study is to establish an HPLC-DAD method for determination of the five constituents (deoxyschizandrin, γ-schizandrin, loganin, paeoniflorin, and paeonol) in Maiwei Dihuang Pills. Methods. An Agilent ZORBAX SB-C18 chromatographic column was carried out to determine the five constituents of 50% methanol extract of Maiwei Dihuang Pills. Results. It was found the chromatographic peak resolution of each component in the study sample solution was 1.5 higher than that of other peaks and no peaks appeared in the blank control solution during the same time, suggesting specificity of HPLC-DAD was well established. The linearity test indicated that deoxyschizandrin, γ-schizandrin, loganin, paeoniflorin, and paeonol were 11.6–72.3 μg/mL, 6.4–45.2 μg/mL, 35.2–237.6 μg/mL, 18.1–114.2 μg/mL, and 32.2–215.3 μg/mL, respectively, suggesting each component has a good linear relationship within its own range. Additionally, the precision of HPLC-DAD was confirmed by a precision test; the stability of the study sample solution was confirmed by a stability test; and good reproducibility of HPLC-DAD was proved by a reproducible test. The recovery rate test showed that relative standard deviation (RSD) of recovery rate in deoxyschizandrin, γ-schizandrin, loganin, paeoniflorin, and paeonol was 100.26% (1.80%), 101.39% (1.74%), 101.19% (1.76%), 102.50% (1.65%), and 102.30% (1.58%), respectively. Conclusions. HPLC-DAD used to determine the five constituents in Maiwei Dihuang Pills, and it was easier and faster to operate, showing good condition in repeatability, precision, stability, and recovery, which is a great option for quality control.</description><subject>Chinese medicine</subject><subject>Chromatography</subject><subject>High-performance liquid chromatography</subject><subject>Noise</subject><subject>Quality control</subject><subject>Sensors</subject><issn>1741-427X</issn><issn>1741-4288</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>RHX</sourceid><sourceid>8G5</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><sourceid>GUQSH</sourceid><sourceid>M2O</sourceid><recordid>eNp9kU1LxDAQhoMoft88S8CLoNV8NJv2Isiuq8KKggreQtKmNtIm2qTK_nuz7rqoBy8zA_PMy8y8AOxhdIIxY6cEEXxKGB0wlq2ATcxTnKQky1aXNX_aAFvevyBEcs75OtigKcOEc7oJ1L1p-yZIq13v4UgH3bXGymCcha6CodZwbN41HDrrgwm9tsFDY-GNNB_awJGpe2mf4Z1pGg_V9Gvg6m4yTEbnI3ijQ-3KHbBWycbr3UXeBo_ji4fhVTK5vbwenk-SIk2zkHCJtKKkTIlCqsqp4lRViFYpR6QskCxkrmipFC4iFEMVEy2YQgjhKteYboOzue5rr1pdFnHVTjbitTOt7KbCSSN-d6ypxbN7F1lKKUI0ChwuBDr31msfRGt8oZtm_h1BGCcE54Msj-jBH_TF9Z2N580ozFnGB4NIHc-ponPed7paLoORmJknZuaJhXkR3_95wBL-disCR3OgNraUH-Z_uU_3cKHZ</recordid><startdate>2021</startdate><enddate>2021</enddate><creator>Jia, Danchun</creator><creator>Cai, Hong</creator><creator>Ke, Yuan</creator><general>Hindawi</general><general>Hindawi Limited</general><scope>RHU</scope><scope>RHW</scope><scope>RHX</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7RV</scope><scope>7T5</scope><scope>7TO</scope><scope>7X7</scope><scope>7XB</scope><scope>88G</scope><scope>8AO</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>H94</scope><scope>K9.</scope><scope>KB0</scope><scope>M0S</scope><scope>M2M</scope><scope>M2O</scope><scope>MBDVC</scope><scope>NAPCQ</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PSYQQ</scope><scope>Q9U</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0001-8223-6831</orcidid></search><sort><creationdate>2021</creationdate><title>Simultaneous Determination of the Five Constituents in Maiwei Dihuang Pills by the HPLC-DAD Method</title><author>Jia, Danchun ; Cai, Hong ; Ke, Yuan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c448t-7a0eb32d42b0bf93b73bf03f4702dc0aca9b3dbb1c32d1c3f32d3c5b0001f9e13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Chinese medicine</topic><topic>Chromatography</topic><topic>High-performance liquid chromatography</topic><topic>Noise</topic><topic>Quality control</topic><topic>Sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jia, Danchun</creatorcontrib><creatorcontrib>Cai, Hong</creatorcontrib><creatorcontrib>Ke, Yuan</creatorcontrib><collection>Hindawi Publishing Complete</collection><collection>Hindawi Publishing Subscription Journals</collection><collection>Hindawi Publishing Open Access Journals</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Nursing &amp; Allied Health Database</collection><collection>Immunology Abstracts</collection><collection>Oncogenes and Growth Factors Abstracts</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Psychology Database (Alumni)</collection><collection>ProQuest Pharma Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Psychology Database</collection><collection>Research Library</collection><collection>Research Library (Corporate)</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest One Psychology</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Evidence-based complementary and alternative medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jia, Danchun</au><au>Cai, Hong</au><au>Ke, Yuan</au><au>Tan, Songwen</au><au>Songwen Tan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simultaneous Determination of the Five Constituents in Maiwei Dihuang Pills by the HPLC-DAD Method</atitle><jtitle>Evidence-based complementary and alternative medicine</jtitle><addtitle>Evid Based Complement Alternat Med</addtitle><date>2021</date><risdate>2021</risdate><volume>2021</volume><spage>2536558</spage><epage>7</epage><pages>2536558-7</pages><issn>1741-427X</issn><eissn>1741-4288</eissn><abstract>Objective. The purpose of study is to establish an HPLC-DAD method for determination of the five constituents (deoxyschizandrin, γ-schizandrin, loganin, paeoniflorin, and paeonol) in Maiwei Dihuang Pills. Methods. An Agilent ZORBAX SB-C18 chromatographic column was carried out to determine the five constituents of 50% methanol extract of Maiwei Dihuang Pills. Results. It was found the chromatographic peak resolution of each component in the study sample solution was 1.5 higher than that of other peaks and no peaks appeared in the blank control solution during the same time, suggesting specificity of HPLC-DAD was well established. The linearity test indicated that deoxyschizandrin, γ-schizandrin, loganin, paeoniflorin, and paeonol were 11.6–72.3 μg/mL, 6.4–45.2 μg/mL, 35.2–237.6 μg/mL, 18.1–114.2 μg/mL, and 32.2–215.3 μg/mL, respectively, suggesting each component has a good linear relationship within its own range. Additionally, the precision of HPLC-DAD was confirmed by a precision test; the stability of the study sample solution was confirmed by a stability test; and good reproducibility of HPLC-DAD was proved by a reproducible test. The recovery rate test showed that relative standard deviation (RSD) of recovery rate in deoxyschizandrin, γ-schizandrin, loganin, paeoniflorin, and paeonol was 100.26% (1.80%), 101.39% (1.74%), 101.19% (1.76%), 102.50% (1.65%), and 102.30% (1.58%), respectively. Conclusions. HPLC-DAD used to determine the five constituents in Maiwei Dihuang Pills, and it was easier and faster to operate, showing good condition in repeatability, precision, stability, and recovery, which is a great option for quality control.</abstract><cop>United States</cop><pub>Hindawi</pub><pmid>34512773</pmid><doi>10.1155/2021/2536558</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0001-8223-6831</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1741-427X
ispartof Evidence-based complementary and alternative medicine, 2021, Vol.2021, p.2536558-7
issn 1741-427X
1741-4288
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8433003
source PubMed Central Open Access; Wiley-Blackwell Open Access Titles; EZB-FREE-00999 freely available EZB journals; PubMed Central; Alma/SFX Local Collection
subjects Chinese medicine
Chromatography
High-performance liquid chromatography
Noise
Quality control
Sensors
title Simultaneous Determination of the Five Constituents in Maiwei Dihuang Pills by the HPLC-DAD Method
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T18%3A50%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simultaneous%20Determination%20of%20the%20Five%20Constituents%20in%20Maiwei%20Dihuang%20Pills%20by%20the%20HPLC-DAD%20Method&rft.jtitle=Evidence-based%20complementary%20and%20alternative%20medicine&rft.au=Jia,%20Danchun&rft.date=2021&rft.volume=2021&rft.spage=2536558&rft.epage=7&rft.pages=2536558-7&rft.issn=1741-427X&rft.eissn=1741-4288&rft_id=info:doi/10.1155/2021/2536558&rft_dat=%3Cproquest_pubme%3E2571758766%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2571758766&rft_id=info:pmid/34512773&rfr_iscdi=true