Use of Intracardiac Echocardiography to Evaluate Continuous-Flow Left Ventricular Assist Device Function in a Man With Obesity
Aortic insufficiency with recirculation can be difficult to diagnose echocardiographically in patients who have continuous-flow left ventricular assist devices. Transthoracic and transesophageal echocardiography can underestimate its severity; moreover, transesophageal echocardiography necessitates...
Gespeichert in:
Veröffentlicht in: | Texas Heart Institute journal 2021-01, Vol.48 (3) |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 3 |
container_start_page | |
container_title | Texas Heart Institute journal |
container_volume | 48 |
creator | Rohm, Charlene L. Howard, Brian Lakhani, Baqir Wilim, Marian Holden, Rachel W. Snipelisky, David |
description | Aortic insufficiency with recirculation can be difficult to diagnose echocardiographically in patients who have continuous-flow left ventricular assist devices. Transthoracic and transesophageal echocardiography can underestimate its severity; moreover, transesophageal echocardiography necessitates general anesthesia. We report the case of a 58-year-old man with obesity and end-stage nonischemic cardiomyopathy who, after 3 months of support with a continuous-flow left ventricular assist device, underwent intracardiac echocardiography to evaluate complications potentially associated with the device. The findings ruled out aortic insufficiency, preventing an unnecessary valvular intervention. |
doi_str_mv | 10.14503/THIJ-20-7303 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8367287</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2550267627</sourcerecordid><originalsourceid>FETCH-LOGICAL-c364t-c7cceb35cca825582a2307efa029537d154fb8edcacc8ddaa4a1e192a97952433</originalsourceid><addsrcrecordid>eNpVUU1PGzEQtVBRCdAjdx-5uPXH7nr3UgmlSQlKxYWPozWZ9RJXGzvY3qBc-O3dAELqaUYzb968mUfIheDfRVFy9ePuenHDJGdacXVEJqKUFas0l1_IhI81JlWhT8hpSn8550oK-ZWcqEIWStTNhLzeJ0tDRxc-R0CIrQOkM1yHtzw8Rdiu9zQHOttBP0C2dBp8dn4IQ2LzPrzQpe0yfbDjvMOhh0ivUnIp019259DS-eAxu-Cp8xToH_D00eU1vV3Z5PL-nBx30Cf77SOekfv57G56zZa3vxfTqyVDVRWZoUa0K1UiQi3LspYgFde2Ay6bUulWlEW3qm2LgFi3LUABwopGQqObcjxVnZGf77zbYbUZcQe50JttdBuIexPAmf873q3NU9iZWlVa1nokuPwgiOF5sCmbjUto-x68HV9hRlVcVrqSByh7h2IMKUXbfa4R3Lx5Zg6eGcnNwTP1D9wji1E</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2550267627</pqid></control><display><type>article</type><title>Use of Intracardiac Echocardiography to Evaluate Continuous-Flow Left Ventricular Assist Device Function in a Man With Obesity</title><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Rohm, Charlene L. ; Howard, Brian ; Lakhani, Baqir ; Wilim, Marian ; Holden, Rachel W. ; Snipelisky, David</creator><creatorcontrib>Rohm, Charlene L. ; Howard, Brian ; Lakhani, Baqir ; Wilim, Marian ; Holden, Rachel W. ; Snipelisky, David</creatorcontrib><description>Aortic insufficiency with recirculation can be difficult to diagnose echocardiographically in patients who have continuous-flow left ventricular assist devices. Transthoracic and transesophageal echocardiography can underestimate its severity; moreover, transesophageal echocardiography necessitates general anesthesia. We report the case of a 58-year-old man with obesity and end-stage nonischemic cardiomyopathy who, after 3 months of support with a continuous-flow left ventricular assist device, underwent intracardiac echocardiography to evaluate complications potentially associated with the device. The findings ruled out aortic insufficiency, preventing an unnecessary valvular intervention.</description><identifier>ISSN: 0730-2347</identifier><identifier>EISSN: 1526-6702</identifier><identifier>DOI: 10.14503/THIJ-20-7303</identifier><identifier>PMID: 34243189</identifier><language>eng</language><publisher>Texas Heart® Institute, Houston</publisher><subject>Case Reports</subject><ispartof>Texas Heart Institute journal, 2021-01, Vol.48 (3)</ispartof><rights>2021 by the Texas Heart® Institute, Houston 2021</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c364t-c7cceb35cca825582a2307efa029537d154fb8edcacc8ddaa4a1e192a97952433</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8367287/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8367287/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,725,778,782,883,27907,27908,53774,53776</link.rule.ids></links><search><creatorcontrib>Rohm, Charlene L.</creatorcontrib><creatorcontrib>Howard, Brian</creatorcontrib><creatorcontrib>Lakhani, Baqir</creatorcontrib><creatorcontrib>Wilim, Marian</creatorcontrib><creatorcontrib>Holden, Rachel W.</creatorcontrib><creatorcontrib>Snipelisky, David</creatorcontrib><title>Use of Intracardiac Echocardiography to Evaluate Continuous-Flow Left Ventricular Assist Device Function in a Man With Obesity</title><title>Texas Heart Institute journal</title><description>Aortic insufficiency with recirculation can be difficult to diagnose echocardiographically in patients who have continuous-flow left ventricular assist devices. Transthoracic and transesophageal echocardiography can underestimate its severity; moreover, transesophageal echocardiography necessitates general anesthesia. We report the case of a 58-year-old man with obesity and end-stage nonischemic cardiomyopathy who, after 3 months of support with a continuous-flow left ventricular assist device, underwent intracardiac echocardiography to evaluate complications potentially associated with the device. The findings ruled out aortic insufficiency, preventing an unnecessary valvular intervention.</description><subject>Case Reports</subject><issn>0730-2347</issn><issn>1526-6702</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNpVUU1PGzEQtVBRCdAjdx-5uPXH7nr3UgmlSQlKxYWPozWZ9RJXGzvY3qBc-O3dAELqaUYzb968mUfIheDfRVFy9ePuenHDJGdacXVEJqKUFas0l1_IhI81JlWhT8hpSn8550oK-ZWcqEIWStTNhLzeJ0tDRxc-R0CIrQOkM1yHtzw8Rdiu9zQHOttBP0C2dBp8dn4IQ2LzPrzQpe0yfbDjvMOhh0ivUnIp019259DS-eAxu-Cp8xToH_D00eU1vV3Z5PL-nBx30Cf77SOekfv57G56zZa3vxfTqyVDVRWZoUa0K1UiQi3LspYgFde2Ay6bUulWlEW3qm2LgFi3LUABwopGQqObcjxVnZGf77zbYbUZcQe50JttdBuIexPAmf873q3NU9iZWlVa1nokuPwgiOF5sCmbjUto-x68HV9hRlVcVrqSByh7h2IMKUXbfa4R3Lx5Zg6eGcnNwTP1D9wji1E</recordid><startdate>20210101</startdate><enddate>20210101</enddate><creator>Rohm, Charlene L.</creator><creator>Howard, Brian</creator><creator>Lakhani, Baqir</creator><creator>Wilim, Marian</creator><creator>Holden, Rachel W.</creator><creator>Snipelisky, David</creator><general>Texas Heart® Institute, Houston</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20210101</creationdate><title>Use of Intracardiac Echocardiography to Evaluate Continuous-Flow Left Ventricular Assist Device Function in a Man With Obesity</title><author>Rohm, Charlene L. ; Howard, Brian ; Lakhani, Baqir ; Wilim, Marian ; Holden, Rachel W. ; Snipelisky, David</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c364t-c7cceb35cca825582a2307efa029537d154fb8edcacc8ddaa4a1e192a97952433</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Case Reports</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rohm, Charlene L.</creatorcontrib><creatorcontrib>Howard, Brian</creatorcontrib><creatorcontrib>Lakhani, Baqir</creatorcontrib><creatorcontrib>Wilim, Marian</creatorcontrib><creatorcontrib>Holden, Rachel W.</creatorcontrib><creatorcontrib>Snipelisky, David</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Texas Heart Institute journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rohm, Charlene L.</au><au>Howard, Brian</au><au>Lakhani, Baqir</au><au>Wilim, Marian</au><au>Holden, Rachel W.</au><au>Snipelisky, David</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Use of Intracardiac Echocardiography to Evaluate Continuous-Flow Left Ventricular Assist Device Function in a Man With Obesity</atitle><jtitle>Texas Heart Institute journal</jtitle><date>2021-01-01</date><risdate>2021</risdate><volume>48</volume><issue>3</issue><issn>0730-2347</issn><eissn>1526-6702</eissn><abstract>Aortic insufficiency with recirculation can be difficult to diagnose echocardiographically in patients who have continuous-flow left ventricular assist devices. Transthoracic and transesophageal echocardiography can underestimate its severity; moreover, transesophageal echocardiography necessitates general anesthesia. We report the case of a 58-year-old man with obesity and end-stage nonischemic cardiomyopathy who, after 3 months of support with a continuous-flow left ventricular assist device, underwent intracardiac echocardiography to evaluate complications potentially associated with the device. The findings ruled out aortic insufficiency, preventing an unnecessary valvular intervention.</abstract><pub>Texas Heart® Institute, Houston</pub><pmid>34243189</pmid><doi>10.14503/THIJ-20-7303</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0730-2347 |
ispartof | Texas Heart Institute journal, 2021-01, Vol.48 (3) |
issn | 0730-2347 1526-6702 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8367287 |
source | PubMed Central; Alma/SFX Local Collection |
subjects | Case Reports |
title | Use of Intracardiac Echocardiography to Evaluate Continuous-Flow Left Ventricular Assist Device Function in a Man With Obesity |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T09%3A05%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Use%20of%20Intracardiac%20Echocardiography%20to%20Evaluate%20Continuous-Flow%20Left%20Ventricular%20Assist%20Device%20Function%20in%20a%20Man%20With%20Obesity&rft.jtitle=Texas%20Heart%20Institute%20journal&rft.au=Rohm,%20Charlene%20L.&rft.date=2021-01-01&rft.volume=48&rft.issue=3&rft.issn=0730-2347&rft.eissn=1526-6702&rft_id=info:doi/10.14503/THIJ-20-7303&rft_dat=%3Cproquest_pubme%3E2550267627%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2550267627&rft_id=info:pmid/34243189&rfr_iscdi=true |