Application of a Fork Plate for Greater Trochanter Osteosynthesis in Total Hip Arthroplasty

was to assess the effectiveness of using an original technique of greater trochanter fragment fixation during total hip replacement. Since 2013, this construction has been implanted in 175 patients in the clinic of the Russian Scientific Research Institute of Traumatology and Orthopedics named after...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sovremennye tekhnologii v medit͡s︡ine 2020-01, Vol.12 (2), p.80-84
Hauptverfasser: Avdeev, A I, Parfeev, D G, Voronkevich, I A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 84
container_issue 2
container_start_page 80
container_title Sovremennye tekhnologii v medit͡s︡ine
container_volume 12
creator Avdeev, A I
Parfeev, D G
Voronkevich, I A
description was to assess the effectiveness of using an original technique of greater trochanter fragment fixation during total hip replacement. Since 2013, this construction has been implanted in 175 patients in the clinic of the Russian Scientific Research Institute of Traumatology and Orthopedics named after R.R. Vreden. By the present time, 50 patients have been examined in order to assess the effectiveness of this construction. They were divided into three groups depending on the cause of greater trochanter fixation by the original plate: osteotomy according to T. Paavilainen, periprosthetic Vancouver type AG fractures, false joints of the greater trochanter. The degree of consolidation of the greater trochanter fragment with the femoral bone metadiaphysis was assessed using the roentgenometric technique according to M. Hamadouche's recommendations. The functional result of the hip was evaluated according to the Oxford Hip Score scale. The nonunion rate in the presented groups was 8.3% in fragment fixation after osteotomy according to T. Paavilainen, 25% after fragment fixation in periprosthetic Vancouver type AG fracture, and 11.1% in fixation of the greater trochanter fragment when treating a false joint of the given localization. Preliminary results of the greater trochanter fixation using the original fork plate during total hip replacement showed sufficient effectiveness not only in osteotomies of the greater trochanter, periprosthetic iatrogenic and pathological Vancouver type AG fractures but also in case of false joints of this localization developed due to the failure of the previous fixation.
doi_str_mv 10.17691/stm2020.12.2.10
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8353675</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2572211665</sourcerecordid><originalsourceid>FETCH-LOGICAL-c349t-b46011382c7946cefe9579396b310bef8f7e31239299e8909349177ec21b7e183</originalsourceid><addsrcrecordid>eNpVUU1LAzEQDaJYqb17khy9bM3HbrK5CKXYKhT0UEHwELJx1ka3mzVJhf57V61F5zJvPt6bgYfQGSVjKoWilzGtGWF9xcZsTMkBOmGcqEyp4vGwx0SKLGc5H6BRjK-kj1IIwcgxGvC8oJwU8gQ9TbqucdYk51vsa2zwzIc3fN-YBLj2Ac8D9DDgZfB2ZdoveBcT-Lht0wqii9i1eOmTafCN6_AkpFXwXWNi2p6io9o0EUa7PEQPs-vl9CZb3M1vp5NFZnmuUlblglDKS2alyoWFGlQhFVei4pRUUJe1BE4ZV0wpKBVRPYtKCZbRSgIt-RBd_eh2m2oNzxbaFEyju-DWJmy1N07_n7RupV_8hy55wYUseoGLnUDw7xuISa9dtNA0pgW_iZoVkjFKhfhaJT-rNvgYA9T7M5Tob1v0zhZNmWZ9t6ec_31vT_g1gX8CtSKJhA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2572211665</pqid></control><display><type>article</type><title>Application of a Fork Plate for Greater Trochanter Osteosynthesis in Total Hip Arthroplasty</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central Open Access</source><source>PubMed Central</source><creator>Avdeev, A I ; Parfeev, D G ; Voronkevich, I A</creator><creatorcontrib>Avdeev, A I ; Parfeev, D G ; Voronkevich, I A</creatorcontrib><description>was to assess the effectiveness of using an original technique of greater trochanter fragment fixation during total hip replacement. Since 2013, this construction has been implanted in 175 patients in the clinic of the Russian Scientific Research Institute of Traumatology and Orthopedics named after R.R. Vreden. By the present time, 50 patients have been examined in order to assess the effectiveness of this construction. They were divided into three groups depending on the cause of greater trochanter fixation by the original plate: osteotomy according to T. Paavilainen, periprosthetic Vancouver type AG fractures, false joints of the greater trochanter. The degree of consolidation of the greater trochanter fragment with the femoral bone metadiaphysis was assessed using the roentgenometric technique according to M. Hamadouche's recommendations. The functional result of the hip was evaluated according to the Oxford Hip Score scale. The nonunion rate in the presented groups was 8.3% in fragment fixation after osteotomy according to T. Paavilainen, 25% after fragment fixation in periprosthetic Vancouver type AG fracture, and 11.1% in fixation of the greater trochanter fragment when treating a false joint of the given localization. Preliminary results of the greater trochanter fixation using the original fork plate during total hip replacement showed sufficient effectiveness not only in osteotomies of the greater trochanter, periprosthetic iatrogenic and pathological Vancouver type AG fractures but also in case of false joints of this localization developed due to the failure of the previous fixation.</description><identifier>ISSN: 2076-4243</identifier><identifier>EISSN: 2309-995X</identifier><identifier>DOI: 10.17691/stm2020.12.2.10</identifier><identifier>PMID: 34513057</identifier><language>eng</language><publisher>Russia (Federation): Privolzhsky Research Medical University</publisher><subject>Clinical Supplements</subject><ispartof>Sovremennye tekhnologii v medit͡s︡ine, 2020-01, Vol.12 (2), p.80-84</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8353675/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8353675/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34513057$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Avdeev, A I</creatorcontrib><creatorcontrib>Parfeev, D G</creatorcontrib><creatorcontrib>Voronkevich, I A</creatorcontrib><title>Application of a Fork Plate for Greater Trochanter Osteosynthesis in Total Hip Arthroplasty</title><title>Sovremennye tekhnologii v medit͡s︡ine</title><addtitle>Sovrem Tekhnologii Med</addtitle><description>was to assess the effectiveness of using an original technique of greater trochanter fragment fixation during total hip replacement. Since 2013, this construction has been implanted in 175 patients in the clinic of the Russian Scientific Research Institute of Traumatology and Orthopedics named after R.R. Vreden. By the present time, 50 patients have been examined in order to assess the effectiveness of this construction. They were divided into three groups depending on the cause of greater trochanter fixation by the original plate: osteotomy according to T. Paavilainen, periprosthetic Vancouver type AG fractures, false joints of the greater trochanter. The degree of consolidation of the greater trochanter fragment with the femoral bone metadiaphysis was assessed using the roentgenometric technique according to M. Hamadouche's recommendations. The functional result of the hip was evaluated according to the Oxford Hip Score scale. The nonunion rate in the presented groups was 8.3% in fragment fixation after osteotomy according to T. Paavilainen, 25% after fragment fixation in periprosthetic Vancouver type AG fracture, and 11.1% in fixation of the greater trochanter fragment when treating a false joint of the given localization. Preliminary results of the greater trochanter fixation using the original fork plate during total hip replacement showed sufficient effectiveness not only in osteotomies of the greater trochanter, periprosthetic iatrogenic and pathological Vancouver type AG fractures but also in case of false joints of this localization developed due to the failure of the previous fixation.</description><subject>Clinical Supplements</subject><issn>2076-4243</issn><issn>2309-995X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNpVUU1LAzEQDaJYqb17khy9bM3HbrK5CKXYKhT0UEHwELJx1ka3mzVJhf57V61F5zJvPt6bgYfQGSVjKoWilzGtGWF9xcZsTMkBOmGcqEyp4vGwx0SKLGc5H6BRjK-kj1IIwcgxGvC8oJwU8gQ9TbqucdYk51vsa2zwzIc3fN-YBLj2Ac8D9DDgZfB2ZdoveBcT-Lht0wqii9i1eOmTafCN6_AkpFXwXWNi2p6io9o0EUa7PEQPs-vl9CZb3M1vp5NFZnmuUlblglDKS2alyoWFGlQhFVei4pRUUJe1BE4ZV0wpKBVRPYtKCZbRSgIt-RBd_eh2m2oNzxbaFEyju-DWJmy1N07_n7RupV_8hy55wYUseoGLnUDw7xuISa9dtNA0pgW_iZoVkjFKhfhaJT-rNvgYA9T7M5Tob1v0zhZNmWZ9t6ec_31vT_g1gX8CtSKJhA</recordid><startdate>20200101</startdate><enddate>20200101</enddate><creator>Avdeev, A I</creator><creator>Parfeev, D G</creator><creator>Voronkevich, I A</creator><general>Privolzhsky Research Medical University</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20200101</creationdate><title>Application of a Fork Plate for Greater Trochanter Osteosynthesis in Total Hip Arthroplasty</title><author>Avdeev, A I ; Parfeev, D G ; Voronkevich, I A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c349t-b46011382c7946cefe9579396b310bef8f7e31239299e8909349177ec21b7e183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Clinical Supplements</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Avdeev, A I</creatorcontrib><creatorcontrib>Parfeev, D G</creatorcontrib><creatorcontrib>Voronkevich, I A</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Sovremennye tekhnologii v medit͡s︡ine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Avdeev, A I</au><au>Parfeev, D G</au><au>Voronkevich, I A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Application of a Fork Plate for Greater Trochanter Osteosynthesis in Total Hip Arthroplasty</atitle><jtitle>Sovremennye tekhnologii v medit͡s︡ine</jtitle><addtitle>Sovrem Tekhnologii Med</addtitle><date>2020-01-01</date><risdate>2020</risdate><volume>12</volume><issue>2</issue><spage>80</spage><epage>84</epage><pages>80-84</pages><issn>2076-4243</issn><eissn>2309-995X</eissn><abstract>was to assess the effectiveness of using an original technique of greater trochanter fragment fixation during total hip replacement. Since 2013, this construction has been implanted in 175 patients in the clinic of the Russian Scientific Research Institute of Traumatology and Orthopedics named after R.R. Vreden. By the present time, 50 patients have been examined in order to assess the effectiveness of this construction. They were divided into three groups depending on the cause of greater trochanter fixation by the original plate: osteotomy according to T. Paavilainen, periprosthetic Vancouver type AG fractures, false joints of the greater trochanter. The degree of consolidation of the greater trochanter fragment with the femoral bone metadiaphysis was assessed using the roentgenometric technique according to M. Hamadouche's recommendations. The functional result of the hip was evaluated according to the Oxford Hip Score scale. The nonunion rate in the presented groups was 8.3% in fragment fixation after osteotomy according to T. Paavilainen, 25% after fragment fixation in periprosthetic Vancouver type AG fracture, and 11.1% in fixation of the greater trochanter fragment when treating a false joint of the given localization. Preliminary results of the greater trochanter fixation using the original fork plate during total hip replacement showed sufficient effectiveness not only in osteotomies of the greater trochanter, periprosthetic iatrogenic and pathological Vancouver type AG fractures but also in case of false joints of this localization developed due to the failure of the previous fixation.</abstract><cop>Russia (Federation)</cop><pub>Privolzhsky Research Medical University</pub><pmid>34513057</pmid><doi>10.17691/stm2020.12.2.10</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2076-4243
ispartof Sovremennye tekhnologii v medit͡s︡ine, 2020-01, Vol.12 (2), p.80-84
issn 2076-4243
2309-995X
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8353675
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central Open Access; PubMed Central
subjects Clinical Supplements
title Application of a Fork Plate for Greater Trochanter Osteosynthesis in Total Hip Arthroplasty
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T16%3A49%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Application%20of%20a%20Fork%20Plate%20for%20Greater%20Trochanter%20Osteosynthesis%20in%20Total%20Hip%20Arthroplasty&rft.jtitle=Sovremennye%20tekhnologii%20v%20medit%CD%A1s%EF%B8%A1ine&rft.au=Avdeev,%20A%20I&rft.date=2020-01-01&rft.volume=12&rft.issue=2&rft.spage=80&rft.epage=84&rft.pages=80-84&rft.issn=2076-4243&rft.eissn=2309-995X&rft_id=info:doi/10.17691/stm2020.12.2.10&rft_dat=%3Cproquest_pubme%3E2572211665%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2572211665&rft_id=info:pmid/34513057&rfr_iscdi=true