Effect of Hematocrit on the CO2 Removal Rate of Artificial Lungs
Extracorporeal CO2 removal (ECCO2R) can permit lung protective or noninvasive ventilation strategies in patients with chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ARDS). With evidence supporting ECCO2R growing, investigating factors which affect CO2 removal i...
Gespeichert in:
Veröffentlicht in: | ASAIO journal (1992) 2020-11, Vol.66 (10), p.1161-1165 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1165 |
---|---|
container_issue | 10 |
container_start_page | 1161 |
container_title | ASAIO journal (1992) |
container_volume | 66 |
creator | May, Alexandra G Omecinski, Katelin S Frankowski, Brian J Federspiel, William J |
description | Extracorporeal CO2 removal (ECCO2R) can permit lung protective or noninvasive ventilation strategies in patients with chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ARDS). With evidence supporting ECCO2R growing, investigating factors which affect CO2 removal is necessary. Multiple factors are known to affect the CO2 removal rate (vCO2) which can complicate the interpretation of changes in vCO2; however, the effect of hematocrit on the vCO2 of artificial lungs has not been investigated. This in vitro study evaluates the relationship between hematocrit level and vCO2 within an ECCO2R device. In vitro gas transfer was measured in bovine blood in accordance with the ISO 7199 standard. Plasma and saline were used to hemodilute the blood to hematocrits between 33% and 8%. The vCO2 significantly decreased as the blood was hemodiluted with saline and plasma by 42% and 32%, respectively, between a hematocrit of 33% and 8%. The hemodilution method did not significantly affect the vCO2. In conclusion, the hematocrit level significantly affects vCO2 and should be taken into account when interpreting changes in the vCO2 of an ECCO2R device. |
doi_str_mv | 10.1097/MAT.0000000000001140 |
format | Article |
fullrecord | <record><control><sourceid>pubmed</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8207609</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>33136604</sourcerecordid><originalsourceid>FETCH-LOGICAL-p163t-903c43e1c919324be497d3dc14525b0d537cee56353ebbb76e7249d2e7c58a223</originalsourceid><addsrcrecordid>eNpVkNtKw0AQhhdRbK2-gUheIHV3Zw_ZG7GUaoVIoVTwLmw2k3alSUqyLfTtjXigzsXMPzP_fBdDyC2jY0aNvn-drMb0JBgT9IwMmYQkNgLez3tNZRJzw9SAXHXdR--RAOySDPoMSlExJI-zskQXoqaM5ljZ0LjW910dhQ1G0wWPllg1B7uNljbgl2vSBl965_tRuq_X3TW5KO22w5ufOiJvT7PVdB6ni-eX6SSNd0xBiA0FJwCZM8wAFzkKowsoHBOSy5wWErRDlAokYJ7nWqHmwhQctZOJ5RxG5OGbu9vnFRYO69DabbZrfWXbY9ZYn_3f1H6TrZtDlnCqFTU94O4U8Hf5-wv4BHRwYVQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Effect of Hematocrit on the CO2 Removal Rate of Artificial Lungs</title><source>MEDLINE</source><source>Journals@Ovid LWW Legacy Archive</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>May, Alexandra G ; Omecinski, Katelin S ; Frankowski, Brian J ; Federspiel, William J</creator><creatorcontrib>May, Alexandra G ; Omecinski, Katelin S ; Frankowski, Brian J ; Federspiel, William J</creatorcontrib><description>Extracorporeal CO2 removal (ECCO2R) can permit lung protective or noninvasive ventilation strategies in patients with chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ARDS). With evidence supporting ECCO2R growing, investigating factors which affect CO2 removal is necessary. Multiple factors are known to affect the CO2 removal rate (vCO2) which can complicate the interpretation of changes in vCO2; however, the effect of hematocrit on the vCO2 of artificial lungs has not been investigated. This in vitro study evaluates the relationship between hematocrit level and vCO2 within an ECCO2R device. In vitro gas transfer was measured in bovine blood in accordance with the ISO 7199 standard. Plasma and saline were used to hemodilute the blood to hematocrits between 33% and 8%. The vCO2 significantly decreased as the blood was hemodiluted with saline and plasma by 42% and 32%, respectively, between a hematocrit of 33% and 8%. The hemodilution method did not significantly affect the vCO2. In conclusion, the hematocrit level significantly affects vCO2 and should be taken into account when interpreting changes in the vCO2 of an ECCO2R device.</description><identifier>ISSN: 1058-2916</identifier><identifier>EISSN: 1538-943X</identifier><identifier>DOI: 10.1097/MAT.0000000000001140</identifier><identifier>PMID: 33136604</identifier><language>eng</language><publisher>United States</publisher><subject>Animals ; Artificial Organs ; Carbon Dioxide - blood ; Cattle ; Extracorporeal Circulation - instrumentation ; Extracorporeal Circulation - methods ; Hematocrit ; Lung ; Noninvasive Ventilation - methods ; Pulmonary Disease, Chronic Obstructive ; Respiratory Distress Syndrome</subject><ispartof>ASAIO journal (1992), 2020-11, Vol.66 (10), p.1161-1165</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33136604$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>May, Alexandra G</creatorcontrib><creatorcontrib>Omecinski, Katelin S</creatorcontrib><creatorcontrib>Frankowski, Brian J</creatorcontrib><creatorcontrib>Federspiel, William J</creatorcontrib><title>Effect of Hematocrit on the CO2 Removal Rate of Artificial Lungs</title><title>ASAIO journal (1992)</title><addtitle>ASAIO J</addtitle><description>Extracorporeal CO2 removal (ECCO2R) can permit lung protective or noninvasive ventilation strategies in patients with chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ARDS). With evidence supporting ECCO2R growing, investigating factors which affect CO2 removal is necessary. Multiple factors are known to affect the CO2 removal rate (vCO2) which can complicate the interpretation of changes in vCO2; however, the effect of hematocrit on the vCO2 of artificial lungs has not been investigated. This in vitro study evaluates the relationship between hematocrit level and vCO2 within an ECCO2R device. In vitro gas transfer was measured in bovine blood in accordance with the ISO 7199 standard. Plasma and saline were used to hemodilute the blood to hematocrits between 33% and 8%. The vCO2 significantly decreased as the blood was hemodiluted with saline and plasma by 42% and 32%, respectively, between a hematocrit of 33% and 8%. The hemodilution method did not significantly affect the vCO2. In conclusion, the hematocrit level significantly affects vCO2 and should be taken into account when interpreting changes in the vCO2 of an ECCO2R device.</description><subject>Animals</subject><subject>Artificial Organs</subject><subject>Carbon Dioxide - blood</subject><subject>Cattle</subject><subject>Extracorporeal Circulation - instrumentation</subject><subject>Extracorporeal Circulation - methods</subject><subject>Hematocrit</subject><subject>Lung</subject><subject>Noninvasive Ventilation - methods</subject><subject>Pulmonary Disease, Chronic Obstructive</subject><subject>Respiratory Distress Syndrome</subject><issn>1058-2916</issn><issn>1538-943X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVkNtKw0AQhhdRbK2-gUheIHV3Zw_ZG7GUaoVIoVTwLmw2k3alSUqyLfTtjXigzsXMPzP_fBdDyC2jY0aNvn-drMb0JBgT9IwMmYQkNgLez3tNZRJzw9SAXHXdR--RAOySDPoMSlExJI-zskQXoqaM5ljZ0LjW910dhQ1G0wWPllg1B7uNljbgl2vSBl965_tRuq_X3TW5KO22w5ufOiJvT7PVdB6ni-eX6SSNd0xBiA0FJwCZM8wAFzkKowsoHBOSy5wWErRDlAokYJ7nWqHmwhQctZOJ5RxG5OGbu9vnFRYO69DabbZrfWXbY9ZYn_3f1H6TrZtDlnCqFTU94O4U8Hf5-wv4BHRwYVQ</recordid><startdate>20201101</startdate><enddate>20201101</enddate><creator>May, Alexandra G</creator><creator>Omecinski, Katelin S</creator><creator>Frankowski, Brian J</creator><creator>Federspiel, William J</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>5PM</scope></search><sort><creationdate>20201101</creationdate><title>Effect of Hematocrit on the CO2 Removal Rate of Artificial Lungs</title><author>May, Alexandra G ; Omecinski, Katelin S ; Frankowski, Brian J ; Federspiel, William J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p163t-903c43e1c919324be497d3dc14525b0d537cee56353ebbb76e7249d2e7c58a223</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Animals</topic><topic>Artificial Organs</topic><topic>Carbon Dioxide - blood</topic><topic>Cattle</topic><topic>Extracorporeal Circulation - instrumentation</topic><topic>Extracorporeal Circulation - methods</topic><topic>Hematocrit</topic><topic>Lung</topic><topic>Noninvasive Ventilation - methods</topic><topic>Pulmonary Disease, Chronic Obstructive</topic><topic>Respiratory Distress Syndrome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>May, Alexandra G</creatorcontrib><creatorcontrib>Omecinski, Katelin S</creatorcontrib><creatorcontrib>Frankowski, Brian J</creatorcontrib><creatorcontrib>Federspiel, William J</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>ASAIO journal (1992)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>May, Alexandra G</au><au>Omecinski, Katelin S</au><au>Frankowski, Brian J</au><au>Federspiel, William J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of Hematocrit on the CO2 Removal Rate of Artificial Lungs</atitle><jtitle>ASAIO journal (1992)</jtitle><addtitle>ASAIO J</addtitle><date>2020-11-01</date><risdate>2020</risdate><volume>66</volume><issue>10</issue><spage>1161</spage><epage>1165</epage><pages>1161-1165</pages><issn>1058-2916</issn><eissn>1538-943X</eissn><abstract>Extracorporeal CO2 removal (ECCO2R) can permit lung protective or noninvasive ventilation strategies in patients with chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ARDS). With evidence supporting ECCO2R growing, investigating factors which affect CO2 removal is necessary. Multiple factors are known to affect the CO2 removal rate (vCO2) which can complicate the interpretation of changes in vCO2; however, the effect of hematocrit on the vCO2 of artificial lungs has not been investigated. This in vitro study evaluates the relationship between hematocrit level and vCO2 within an ECCO2R device. In vitro gas transfer was measured in bovine blood in accordance with the ISO 7199 standard. Plasma and saline were used to hemodilute the blood to hematocrits between 33% and 8%. The vCO2 significantly decreased as the blood was hemodiluted with saline and plasma by 42% and 32%, respectively, between a hematocrit of 33% and 8%. The hemodilution method did not significantly affect the vCO2. In conclusion, the hematocrit level significantly affects vCO2 and should be taken into account when interpreting changes in the vCO2 of an ECCO2R device.</abstract><cop>United States</cop><pmid>33136604</pmid><doi>10.1097/MAT.0000000000001140</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1058-2916 |
ispartof | ASAIO journal (1992), 2020-11, Vol.66 (10), p.1161-1165 |
issn | 1058-2916 1538-943X |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8207609 |
source | MEDLINE; Journals@Ovid LWW Legacy Archive; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals |
subjects | Animals Artificial Organs Carbon Dioxide - blood Cattle Extracorporeal Circulation - instrumentation Extracorporeal Circulation - methods Hematocrit Lung Noninvasive Ventilation - methods Pulmonary Disease, Chronic Obstructive Respiratory Distress Syndrome |
title | Effect of Hematocrit on the CO2 Removal Rate of Artificial Lungs |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T07%3A03%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20Hematocrit%20on%20the%20CO2%20Removal%20Rate%20of%20Artificial%20Lungs&rft.jtitle=ASAIO%20journal%20(1992)&rft.au=May,%20Alexandra%20G&rft.date=2020-11-01&rft.volume=66&rft.issue=10&rft.spage=1161&rft.epage=1165&rft.pages=1161-1165&rft.issn=1058-2916&rft.eissn=1538-943X&rft_id=info:doi/10.1097/MAT.0000000000001140&rft_dat=%3Cpubmed%3E33136604%3C/pubmed%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/33136604&rfr_iscdi=true |