A Simplified Model for Intravoxel Incoherent Motion Perfusion Imaging of the Brain

Despite a recent resurgence, intravoxel incoherent motion MRI faces practical challenges, including limited SNR and demanding acquisition and postprocessing requirements. A simplified approach using linear fitting of a subset of higher b-values has seen success in other organ systems. We sought to v...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of neuroradiology : AJNR 2016-12, Vol.37 (12), p.2251-2257
Hauptverfasser: Conklin, J, Heyn, C, Roux, M, Cerny, M, Wintermark, M, Federau, C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2257
container_issue 12
container_start_page 2251
container_title American journal of neuroradiology : AJNR
container_volume 37
creator Conklin, J
Heyn, C
Roux, M
Cerny, M
Wintermark, M
Federau, C
description Despite a recent resurgence, intravoxel incoherent motion MRI faces practical challenges, including limited SNR and demanding acquisition and postprocessing requirements. A simplified approach using linear fitting of a subset of higher b-values has seen success in other organ systems. We sought to validate this method for evaluation of brain pathology by comparing perfusion measurements using simplified linear fitting to conventional biexponential fitting. Forty-nine patients with gliomas and 17 with acute strokes underwent 3T MRI, including DWI with 16 b-values (range, 0-900 s/mm ). Conventional intravoxel incoherent motion was performed using nonlinear fitting of the standard biexponential equation. Simplified intravoxel incoherent motion was performed using linear fitting of the log-normalized signal curves for subsets of b-values >200 s/mm . Comparisons between ROIs (tumors, strokes, contralateral brain) and between models (biexponential and simplified linear) were performed by using 2-way ANOVA. The root mean square error and coefficient of determination (R ) were computed for the simplified model, with biexponential fitting as the reference standard. Perfusion maps using simplified linear fitting were qualitatively similar to conventional biexponential fitting. The perfusion fraction was elevated in high-grade (n = 33) compared to low-grade (n = 16) gliomas and was reduced in strokes compared to the contralateral brain (P < .001 for both main effects). Decreasing the number of b-values used for linear fitting resulted in reduced accuracy (higher root mean square error and lower R ) compared with full biexponential fitting. Intravoxel incoherent motion perfusion imaging of common brain pathology can be performed by using simplified linear fitting, with preservation of clinically relevant perfusion information.
doi_str_mv 10.3174/ajnr.A4929
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7963855</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1852654906</sourcerecordid><originalsourceid>FETCH-LOGICAL-c411t-1397685fb7112021e693d9a03a406323db7af4621fb9b64ab7b12ef1ee9199543</originalsourceid><addsrcrecordid>eNqNkc1LHEEQxRtRdN148Q8Ic5TAmK7-mqlLYCOaLBiUfEBuTc9M927LTPfaPSvxv3c2GkluOVUV7_F4xY-QU6DnHCrx3tyFdL4QyHCPzAC5KlHiz30yo4CyVEDrI3Kc8x2lVGLFDskRq6SCmosZ-boovvlh03vnbVd8iZ3tCxdTsQxjMg_x13QuQxvXNtkwTvroYyhubXLbvNuWg1n5sCqiK8a1LT4m48MbcuBMn-3Jy5yTH1eX3y8-l9c3n5YXi-uyFQBjCRwrVUvXVACMMrAKeYeGciOo4ox3TWWcUAxcg40SpqkaYNaBtQiIUvA5-fCcu9k2g-1au6vc603yg0mPOhqv_1WCX-tVfNAVKl5LOQWcvQSkeL-1edSDz63texNs3GYNtURR85rV_2NlSgqcms_Ju2drm2LOybrXRkD1jpfe8dK_eU3mt3__8Gr9A4g_AbGekS4</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1852654906</pqid></control><display><type>article</type><title>A Simplified Model for Intravoxel Incoherent Motion Perfusion Imaging of the Brain</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><creator>Conklin, J ; Heyn, C ; Roux, M ; Cerny, M ; Wintermark, M ; Federau, C</creator><creatorcontrib>Conklin, J ; Heyn, C ; Roux, M ; Cerny, M ; Wintermark, M ; Federau, C</creatorcontrib><description>Despite a recent resurgence, intravoxel incoherent motion MRI faces practical challenges, including limited SNR and demanding acquisition and postprocessing requirements. A simplified approach using linear fitting of a subset of higher b-values has seen success in other organ systems. We sought to validate this method for evaluation of brain pathology by comparing perfusion measurements using simplified linear fitting to conventional biexponential fitting. Forty-nine patients with gliomas and 17 with acute strokes underwent 3T MRI, including DWI with 16 b-values (range, 0-900 s/mm ). Conventional intravoxel incoherent motion was performed using nonlinear fitting of the standard biexponential equation. Simplified intravoxel incoherent motion was performed using linear fitting of the log-normalized signal curves for subsets of b-values &gt;200 s/mm . Comparisons between ROIs (tumors, strokes, contralateral brain) and between models (biexponential and simplified linear) were performed by using 2-way ANOVA. The root mean square error and coefficient of determination (R ) were computed for the simplified model, with biexponential fitting as the reference standard. Perfusion maps using simplified linear fitting were qualitatively similar to conventional biexponential fitting. The perfusion fraction was elevated in high-grade (n = 33) compared to low-grade (n = 16) gliomas and was reduced in strokes compared to the contralateral brain (P &lt; .001 for both main effects). Decreasing the number of b-values used for linear fitting resulted in reduced accuracy (higher root mean square error and lower R ) compared with full biexponential fitting. Intravoxel incoherent motion perfusion imaging of common brain pathology can be performed by using simplified linear fitting, with preservation of clinically relevant perfusion information.</description><identifier>ISSN: 0195-6108</identifier><identifier>EISSN: 1936-959X</identifier><identifier>DOI: 10.3174/ajnr.A4929</identifier><identifier>PMID: 27561834</identifier><language>eng</language><publisher>United States: American Society of Neuroradiology</publisher><subject>Adult Brain ; Brain - diagnostic imaging ; Brain - pathology ; Brain Neoplasms - blood supply ; Brain Neoplasms - diagnostic imaging ; Brain Neoplasms - pathology ; Diffusion Magnetic Resonance Imaging - methods ; Female ; Glioma - blood supply ; Glioma - diagnostic imaging ; Glioma - pathology ; Humans ; Image Interpretation, Computer-Assisted - methods ; Magnetic Resonance Imaging ; Male ; Middle Aged ; Models, Theoretical ; Motion ; Perfusion Imaging - methods ; Reproducibility of Results ; Stroke - diagnostic imaging ; Stroke - pathology</subject><ispartof>American journal of neuroradiology : AJNR, 2016-12, Vol.37 (12), p.2251-2257</ispartof><rights>2016 by American Journal of Neuroradiology.</rights><rights>2016 by American Journal of Neuroradiology 2016 American Journal of Neuroradiology</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c411t-1397685fb7112021e693d9a03a406323db7af4621fb9b64ab7b12ef1ee9199543</citedby><cites>FETCH-LOGICAL-c411t-1397685fb7112021e693d9a03a406323db7af4621fb9b64ab7b12ef1ee9199543</cites><orcidid>0000-0002-4126-9722 ; 0000-0002-3803-6602 ; 0000-0002-3226-5199 ; 0000-0001-5033-7507 ; 0000-0002-6726-3951 ; 0000-0001-9921-2086</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7963855/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7963855/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,723,776,780,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27561834$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Conklin, J</creatorcontrib><creatorcontrib>Heyn, C</creatorcontrib><creatorcontrib>Roux, M</creatorcontrib><creatorcontrib>Cerny, M</creatorcontrib><creatorcontrib>Wintermark, M</creatorcontrib><creatorcontrib>Federau, C</creatorcontrib><title>A Simplified Model for Intravoxel Incoherent Motion Perfusion Imaging of the Brain</title><title>American journal of neuroradiology : AJNR</title><addtitle>AJNR Am J Neuroradiol</addtitle><description>Despite a recent resurgence, intravoxel incoherent motion MRI faces practical challenges, including limited SNR and demanding acquisition and postprocessing requirements. A simplified approach using linear fitting of a subset of higher b-values has seen success in other organ systems. We sought to validate this method for evaluation of brain pathology by comparing perfusion measurements using simplified linear fitting to conventional biexponential fitting. Forty-nine patients with gliomas and 17 with acute strokes underwent 3T MRI, including DWI with 16 b-values (range, 0-900 s/mm ). Conventional intravoxel incoherent motion was performed using nonlinear fitting of the standard biexponential equation. Simplified intravoxel incoherent motion was performed using linear fitting of the log-normalized signal curves for subsets of b-values &gt;200 s/mm . Comparisons between ROIs (tumors, strokes, contralateral brain) and between models (biexponential and simplified linear) were performed by using 2-way ANOVA. The root mean square error and coefficient of determination (R ) were computed for the simplified model, with biexponential fitting as the reference standard. Perfusion maps using simplified linear fitting were qualitatively similar to conventional biexponential fitting. The perfusion fraction was elevated in high-grade (n = 33) compared to low-grade (n = 16) gliomas and was reduced in strokes compared to the contralateral brain (P &lt; .001 for both main effects). Decreasing the number of b-values used for linear fitting resulted in reduced accuracy (higher root mean square error and lower R ) compared with full biexponential fitting. Intravoxel incoherent motion perfusion imaging of common brain pathology can be performed by using simplified linear fitting, with preservation of clinically relevant perfusion information.</description><subject>Adult Brain</subject><subject>Brain - diagnostic imaging</subject><subject>Brain - pathology</subject><subject>Brain Neoplasms - blood supply</subject><subject>Brain Neoplasms - diagnostic imaging</subject><subject>Brain Neoplasms - pathology</subject><subject>Diffusion Magnetic Resonance Imaging - methods</subject><subject>Female</subject><subject>Glioma - blood supply</subject><subject>Glioma - diagnostic imaging</subject><subject>Glioma - pathology</subject><subject>Humans</subject><subject>Image Interpretation, Computer-Assisted - methods</subject><subject>Magnetic Resonance Imaging</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Models, Theoretical</subject><subject>Motion</subject><subject>Perfusion Imaging - methods</subject><subject>Reproducibility of Results</subject><subject>Stroke - diagnostic imaging</subject><subject>Stroke - pathology</subject><issn>0195-6108</issn><issn>1936-959X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNkc1LHEEQxRtRdN148Q8Ic5TAmK7-mqlLYCOaLBiUfEBuTc9M927LTPfaPSvxv3c2GkluOVUV7_F4xY-QU6DnHCrx3tyFdL4QyHCPzAC5KlHiz30yo4CyVEDrI3Kc8x2lVGLFDskRq6SCmosZ-boovvlh03vnbVd8iZ3tCxdTsQxjMg_x13QuQxvXNtkwTvroYyhubXLbvNuWg1n5sCqiK8a1LT4m48MbcuBMn-3Jy5yTH1eX3y8-l9c3n5YXi-uyFQBjCRwrVUvXVACMMrAKeYeGciOo4ox3TWWcUAxcg40SpqkaYNaBtQiIUvA5-fCcu9k2g-1au6vc603yg0mPOhqv_1WCX-tVfNAVKl5LOQWcvQSkeL-1edSDz63texNs3GYNtURR85rV_2NlSgqcms_Ju2drm2LOybrXRkD1jpfe8dK_eU3mt3__8Gr9A4g_AbGekS4</recordid><startdate>201612</startdate><enddate>201612</enddate><creator>Conklin, J</creator><creator>Heyn, C</creator><creator>Roux, M</creator><creator>Cerny, M</creator><creator>Wintermark, M</creator><creator>Federau, C</creator><general>American Society of Neuroradiology</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7TK</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-4126-9722</orcidid><orcidid>https://orcid.org/0000-0002-3803-6602</orcidid><orcidid>https://orcid.org/0000-0002-3226-5199</orcidid><orcidid>https://orcid.org/0000-0001-5033-7507</orcidid><orcidid>https://orcid.org/0000-0002-6726-3951</orcidid><orcidid>https://orcid.org/0000-0001-9921-2086</orcidid></search><sort><creationdate>201612</creationdate><title>A Simplified Model for Intravoxel Incoherent Motion Perfusion Imaging of the Brain</title><author>Conklin, J ; Heyn, C ; Roux, M ; Cerny, M ; Wintermark, M ; Federau, C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c411t-1397685fb7112021e693d9a03a406323db7af4621fb9b64ab7b12ef1ee9199543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Adult Brain</topic><topic>Brain - diagnostic imaging</topic><topic>Brain - pathology</topic><topic>Brain Neoplasms - blood supply</topic><topic>Brain Neoplasms - diagnostic imaging</topic><topic>Brain Neoplasms - pathology</topic><topic>Diffusion Magnetic Resonance Imaging - methods</topic><topic>Female</topic><topic>Glioma - blood supply</topic><topic>Glioma - diagnostic imaging</topic><topic>Glioma - pathology</topic><topic>Humans</topic><topic>Image Interpretation, Computer-Assisted - methods</topic><topic>Magnetic Resonance Imaging</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Models, Theoretical</topic><topic>Motion</topic><topic>Perfusion Imaging - methods</topic><topic>Reproducibility of Results</topic><topic>Stroke - diagnostic imaging</topic><topic>Stroke - pathology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Conklin, J</creatorcontrib><creatorcontrib>Heyn, C</creatorcontrib><creatorcontrib>Roux, M</creatorcontrib><creatorcontrib>Cerny, M</creatorcontrib><creatorcontrib>Wintermark, M</creatorcontrib><creatorcontrib>Federau, C</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Neurosciences Abstracts</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>American journal of neuroradiology : AJNR</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Conklin, J</au><au>Heyn, C</au><au>Roux, M</au><au>Cerny, M</au><au>Wintermark, M</au><au>Federau, C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Simplified Model for Intravoxel Incoherent Motion Perfusion Imaging of the Brain</atitle><jtitle>American journal of neuroradiology : AJNR</jtitle><addtitle>AJNR Am J Neuroradiol</addtitle><date>2016-12</date><risdate>2016</risdate><volume>37</volume><issue>12</issue><spage>2251</spage><epage>2257</epage><pages>2251-2257</pages><issn>0195-6108</issn><eissn>1936-959X</eissn><abstract>Despite a recent resurgence, intravoxel incoherent motion MRI faces practical challenges, including limited SNR and demanding acquisition and postprocessing requirements. A simplified approach using linear fitting of a subset of higher b-values has seen success in other organ systems. We sought to validate this method for evaluation of brain pathology by comparing perfusion measurements using simplified linear fitting to conventional biexponential fitting. Forty-nine patients with gliomas and 17 with acute strokes underwent 3T MRI, including DWI with 16 b-values (range, 0-900 s/mm ). Conventional intravoxel incoherent motion was performed using nonlinear fitting of the standard biexponential equation. Simplified intravoxel incoherent motion was performed using linear fitting of the log-normalized signal curves for subsets of b-values &gt;200 s/mm . Comparisons between ROIs (tumors, strokes, contralateral brain) and between models (biexponential and simplified linear) were performed by using 2-way ANOVA. The root mean square error and coefficient of determination (R ) were computed for the simplified model, with biexponential fitting as the reference standard. Perfusion maps using simplified linear fitting were qualitatively similar to conventional biexponential fitting. The perfusion fraction was elevated in high-grade (n = 33) compared to low-grade (n = 16) gliomas and was reduced in strokes compared to the contralateral brain (P &lt; .001 for both main effects). Decreasing the number of b-values used for linear fitting resulted in reduced accuracy (higher root mean square error and lower R ) compared with full biexponential fitting. Intravoxel incoherent motion perfusion imaging of common brain pathology can be performed by using simplified linear fitting, with preservation of clinically relevant perfusion information.</abstract><cop>United States</cop><pub>American Society of Neuroradiology</pub><pmid>27561834</pmid><doi>10.3174/ajnr.A4929</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-4126-9722</orcidid><orcidid>https://orcid.org/0000-0002-3803-6602</orcidid><orcidid>https://orcid.org/0000-0002-3226-5199</orcidid><orcidid>https://orcid.org/0000-0001-5033-7507</orcidid><orcidid>https://orcid.org/0000-0002-6726-3951</orcidid><orcidid>https://orcid.org/0000-0001-9921-2086</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0195-6108
ispartof American journal of neuroradiology : AJNR, 2016-12, Vol.37 (12), p.2251-2257
issn 0195-6108
1936-959X
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7963855
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central
subjects Adult Brain
Brain - diagnostic imaging
Brain - pathology
Brain Neoplasms - blood supply
Brain Neoplasms - diagnostic imaging
Brain Neoplasms - pathology
Diffusion Magnetic Resonance Imaging - methods
Female
Glioma - blood supply
Glioma - diagnostic imaging
Glioma - pathology
Humans
Image Interpretation, Computer-Assisted - methods
Magnetic Resonance Imaging
Male
Middle Aged
Models, Theoretical
Motion
Perfusion Imaging - methods
Reproducibility of Results
Stroke - diagnostic imaging
Stroke - pathology
title A Simplified Model for Intravoxel Incoherent Motion Perfusion Imaging of the Brain
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T22%3A10%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Simplified%20Model%20for%20Intravoxel%20Incoherent%20Motion%20Perfusion%20Imaging%20of%20the%20Brain&rft.jtitle=American%20journal%20of%20neuroradiology%20:%20AJNR&rft.au=Conklin,%20J&rft.date=2016-12&rft.volume=37&rft.issue=12&rft.spage=2251&rft.epage=2257&rft.pages=2251-2257&rft.issn=0195-6108&rft.eissn=1936-959X&rft_id=info:doi/10.3174/ajnr.A4929&rft_dat=%3Cproquest_pubme%3E1852654906%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1852654906&rft_id=info:pmid/27561834&rfr_iscdi=true