Timing of indocyanine green injection prior to laparoscopic colorectal surgery for tumor localization: a prospective case series

Background Accurate identification of tumor sites during laparoscopic colorectal surgery helps to optimize oncological clearance. We aimed to assess the timing of the local injection preoperatively and clarify the usefulness and limitation of tumor site marking using indocyanine green (ICG) fluoresc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surgical endoscopy 2021-02, Vol.35 (2), p.763-769
Hauptverfasser: Satoyoshi, Tetsuta, Okita, Kenji, Ishii, Masayuki, Hamabe, Atsushi, Usui, Akihiro, Akizuki, Emi, Okuya, Koichi, Nishidate, Toshihiko, Yamano, Hiroo, Nakase, Hiroshi, Takemasa, Ichiro
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 769
container_issue 2
container_start_page 763
container_title Surgical endoscopy
container_volume 35
creator Satoyoshi, Tetsuta
Okita, Kenji
Ishii, Masayuki
Hamabe, Atsushi
Usui, Akihiro
Akizuki, Emi
Okuya, Koichi
Nishidate, Toshihiko
Yamano, Hiroo
Nakase, Hiroshi
Takemasa, Ichiro
description Background Accurate identification of tumor sites during laparoscopic colorectal surgery helps to optimize oncological clearance. We aimed to assess the timing of the local injection preoperatively and clarify the usefulness and limitation of tumor site marking using indocyanine green (ICG) fluorescence imaging. Methods Consecutive patients who underwent primary colorectal cancer surgery from September 2017 to January 2019 were included. Preoperatively, lower endoscopy was used to inject the ICG solution into the submucosal layer near the tumor. During laparoscopic surgery, ICG fluorescence marking as the tumor site marking was detected using a laparoscopic near-infrared camera system. The detection rate and factors associated with successful intraoperative ICG fluorescence visualization including the interval between local injection and surgery were evaluated. Results One hundred sixty-five patients were enrolled. Using the laparoscopic near-infrared system, the intraoperative detection rates of ICG marking were 100% for ICG injection within 6 days preoperatively, 60% for injection between 7 and 9 days preoperatively, and 0% for injection earlier than 10 days preoperatively. There were no complications associated with ICG marking. Additionally, this method did not disturb the progress of the surgical procedure because injected ICG in the submucosal layer did not cause any tissue inflammation, and if ICG spilled into the serosa, it was invisible by white light. Conclusion Advantages of ICG fluorescence tumor site marking were high visibility of infrared imaging during laparoscopic colorectal surgery and minimal adverse events of surgery. One of the most important findings regarding practical use was a rapid decrease in fluorescence marking visibility if one week passed from the time of ICG local injection.
doi_str_mv 10.1007/s00464-020-07443-5
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7819920</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2358575070</sourcerecordid><originalsourceid>FETCH-LOGICAL-c540t-f9f8c18150d13c618d65317c4186c5e2425b66d759eb0a959ec35eb7b13dd6553</originalsourceid><addsrcrecordid>eNp9kUtv1TAQhS0EopfCH2CBLLFhE_AzdlggVRUvqRKbsrYcZ3LxlWMHO6l0WfHTcbilPBZsPJLnmzM-Pgg9peQlJUS9KoSIVjSEkYYoIXgj76EdFZw1jFF9H-1Ix0nDVCfO0KNSDqTyHZUP0RlnRDGm9A59v_aTj3ucRuzjkNzRRh8B7zNArDcHcItPEc_Zp4yXhIOdbU7Fpdk77FJIuRI24LLmPeQjHjdsneoZkrPBf7Pb_Gtsq0Qq8yZ3A9jZArhA9lAeowejDQWe3NZz9Pnd2-vLD83Vp_cfLy-uGicFWZqxG7WjmkoyUO5aqodWcqqcoLp1Ephgsm_bQckOemK7WhyX0Kue8qGikp-jNyfdee0nGBzEJdtgqrHJ5qNJ1pu_O9F_Mft0Y5SmXcdIFXhxK5DT1xXKYiZfHIRgI6S1GMallkoStaHP_0EPac2x2jNMqE7WRDSrFDtRrv5MyTDePYYSswVsTgGbGrD5GbDZbDz708bdyK9EK8BPQKmtWDP5vfs_sj8A6HS0CQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2479579482</pqid></control><display><type>article</type><title>Timing of indocyanine green injection prior to laparoscopic colorectal surgery for tumor localization: a prospective case series</title><source>SpringerLink Journals - AutoHoldings</source><creator>Satoyoshi, Tetsuta ; Okita, Kenji ; Ishii, Masayuki ; Hamabe, Atsushi ; Usui, Akihiro ; Akizuki, Emi ; Okuya, Koichi ; Nishidate, Toshihiko ; Yamano, Hiroo ; Nakase, Hiroshi ; Takemasa, Ichiro</creator><creatorcontrib>Satoyoshi, Tetsuta ; Okita, Kenji ; Ishii, Masayuki ; Hamabe, Atsushi ; Usui, Akihiro ; Akizuki, Emi ; Okuya, Koichi ; Nishidate, Toshihiko ; Yamano, Hiroo ; Nakase, Hiroshi ; Takemasa, Ichiro</creatorcontrib><description>Background Accurate identification of tumor sites during laparoscopic colorectal surgery helps to optimize oncological clearance. We aimed to assess the timing of the local injection preoperatively and clarify the usefulness and limitation of tumor site marking using indocyanine green (ICG) fluorescence imaging. Methods Consecutive patients who underwent primary colorectal cancer surgery from September 2017 to January 2019 were included. Preoperatively, lower endoscopy was used to inject the ICG solution into the submucosal layer near the tumor. During laparoscopic surgery, ICG fluorescence marking as the tumor site marking was detected using a laparoscopic near-infrared camera system. The detection rate and factors associated with successful intraoperative ICG fluorescence visualization including the interval between local injection and surgery were evaluated. Results One hundred sixty-five patients were enrolled. Using the laparoscopic near-infrared system, the intraoperative detection rates of ICG marking were 100% for ICG injection within 6 days preoperatively, 60% for injection between 7 and 9 days preoperatively, and 0% for injection earlier than 10 days preoperatively. There were no complications associated with ICG marking. Additionally, this method did not disturb the progress of the surgical procedure because injected ICG in the submucosal layer did not cause any tissue inflammation, and if ICG spilled into the serosa, it was invisible by white light. Conclusion Advantages of ICG fluorescence tumor site marking were high visibility of infrared imaging during laparoscopic colorectal surgery and minimal adverse events of surgery. One of the most important findings regarding practical use was a rapid decrease in fluorescence marking visibility if one week passed from the time of ICG local injection.</description><identifier>ISSN: 0930-2794</identifier><identifier>EISSN: 1432-2218</identifier><identifier>DOI: 10.1007/s00464-020-07443-5</identifier><identifier>PMID: 32072278</identifier><language>eng</language><publisher>New York: Springer US</publisher><subject>Abdominal Surgery ; Cancer surgery ; Clinical medicine ; Colonoscopy ; Colorectal cancer ; Colorectal surgery ; Endoscopy ; Fluorescence ; Gastroenterology ; Gynecology ; Hepatology ; Inflammation ; Injections ; Laparoscopy ; Medicine ; Medicine &amp; Public Health ; Proctology ; Surgery</subject><ispartof>Surgical endoscopy, 2021-02, Vol.35 (2), p.763-769</ispartof><rights>The Author(s) 2020</rights><rights>The Author(s) 2020. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c540t-f9f8c18150d13c618d65317c4186c5e2425b66d759eb0a959ec35eb7b13dd6553</citedby><cites>FETCH-LOGICAL-c540t-f9f8c18150d13c618d65317c4186c5e2425b66d759eb0a959ec35eb7b13dd6553</cites><orcidid>0000-0001-8339-6028</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00464-020-07443-5$$EPDF$$P50$$Gspringer$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00464-020-07443-5$$EHTML$$P50$$Gspringer$$Hfree_for_read</linktohtml><link.rule.ids>230,314,780,784,885,27922,27923,41486,42555,51317</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32072278$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Satoyoshi, Tetsuta</creatorcontrib><creatorcontrib>Okita, Kenji</creatorcontrib><creatorcontrib>Ishii, Masayuki</creatorcontrib><creatorcontrib>Hamabe, Atsushi</creatorcontrib><creatorcontrib>Usui, Akihiro</creatorcontrib><creatorcontrib>Akizuki, Emi</creatorcontrib><creatorcontrib>Okuya, Koichi</creatorcontrib><creatorcontrib>Nishidate, Toshihiko</creatorcontrib><creatorcontrib>Yamano, Hiroo</creatorcontrib><creatorcontrib>Nakase, Hiroshi</creatorcontrib><creatorcontrib>Takemasa, Ichiro</creatorcontrib><title>Timing of indocyanine green injection prior to laparoscopic colorectal surgery for tumor localization: a prospective case series</title><title>Surgical endoscopy</title><addtitle>Surg Endosc</addtitle><addtitle>Surg Endosc</addtitle><description>Background Accurate identification of tumor sites during laparoscopic colorectal surgery helps to optimize oncological clearance. We aimed to assess the timing of the local injection preoperatively and clarify the usefulness and limitation of tumor site marking using indocyanine green (ICG) fluorescence imaging. Methods Consecutive patients who underwent primary colorectal cancer surgery from September 2017 to January 2019 were included. Preoperatively, lower endoscopy was used to inject the ICG solution into the submucosal layer near the tumor. During laparoscopic surgery, ICG fluorescence marking as the tumor site marking was detected using a laparoscopic near-infrared camera system. The detection rate and factors associated with successful intraoperative ICG fluorescence visualization including the interval between local injection and surgery were evaluated. Results One hundred sixty-five patients were enrolled. Using the laparoscopic near-infrared system, the intraoperative detection rates of ICG marking were 100% for ICG injection within 6 days preoperatively, 60% for injection between 7 and 9 days preoperatively, and 0% for injection earlier than 10 days preoperatively. There were no complications associated with ICG marking. Additionally, this method did not disturb the progress of the surgical procedure because injected ICG in the submucosal layer did not cause any tissue inflammation, and if ICG spilled into the serosa, it was invisible by white light. Conclusion Advantages of ICG fluorescence tumor site marking were high visibility of infrared imaging during laparoscopic colorectal surgery and minimal adverse events of surgery. One of the most important findings regarding practical use was a rapid decrease in fluorescence marking visibility if one week passed from the time of ICG local injection.</description><subject>Abdominal Surgery</subject><subject>Cancer surgery</subject><subject>Clinical medicine</subject><subject>Colonoscopy</subject><subject>Colorectal cancer</subject><subject>Colorectal surgery</subject><subject>Endoscopy</subject><subject>Fluorescence</subject><subject>Gastroenterology</subject><subject>Gynecology</subject><subject>Hepatology</subject><subject>Inflammation</subject><subject>Injections</subject><subject>Laparoscopy</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Proctology</subject><subject>Surgery</subject><issn>0930-2794</issn><issn>1432-2218</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>C6C</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><recordid>eNp9kUtv1TAQhS0EopfCH2CBLLFhE_AzdlggVRUvqRKbsrYcZ3LxlWMHO6l0WfHTcbilPBZsPJLnmzM-Pgg9peQlJUS9KoSIVjSEkYYoIXgj76EdFZw1jFF9H-1Ix0nDVCfO0KNSDqTyHZUP0RlnRDGm9A59v_aTj3ucRuzjkNzRRh8B7zNArDcHcItPEc_Zp4yXhIOdbU7Fpdk77FJIuRI24LLmPeQjHjdsneoZkrPBf7Pb_Gtsq0Qq8yZ3A9jZArhA9lAeowejDQWe3NZz9Pnd2-vLD83Vp_cfLy-uGicFWZqxG7WjmkoyUO5aqodWcqqcoLp1Ephgsm_bQckOemK7WhyX0Kue8qGikp-jNyfdee0nGBzEJdtgqrHJ5qNJ1pu_O9F_Mft0Y5SmXcdIFXhxK5DT1xXKYiZfHIRgI6S1GMallkoStaHP_0EPac2x2jNMqE7WRDSrFDtRrv5MyTDePYYSswVsTgGbGrD5GbDZbDz708bdyK9EK8BPQKmtWDP5vfs_sj8A6HS0CQ</recordid><startdate>20210201</startdate><enddate>20210201</enddate><creator>Satoyoshi, Tetsuta</creator><creator>Okita, Kenji</creator><creator>Ishii, Masayuki</creator><creator>Hamabe, Atsushi</creator><creator>Usui, Akihiro</creator><creator>Akizuki, Emi</creator><creator>Okuya, Koichi</creator><creator>Nishidate, Toshihiko</creator><creator>Yamano, Hiroo</creator><creator>Nakase, Hiroshi</creator><creator>Takemasa, Ichiro</creator><general>Springer US</general><general>Springer Nature B.V</general><scope>C6C</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7RV</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>KB0</scope><scope>M0S</scope><scope>M1P</scope><scope>NAPCQ</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0001-8339-6028</orcidid></search><sort><creationdate>20210201</creationdate><title>Timing of indocyanine green injection prior to laparoscopic colorectal surgery for tumor localization: a prospective case series</title><author>Satoyoshi, Tetsuta ; Okita, Kenji ; Ishii, Masayuki ; Hamabe, Atsushi ; Usui, Akihiro ; Akizuki, Emi ; Okuya, Koichi ; Nishidate, Toshihiko ; Yamano, Hiroo ; Nakase, Hiroshi ; Takemasa, Ichiro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c540t-f9f8c18150d13c618d65317c4186c5e2425b66d759eb0a959ec35eb7b13dd6553</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Abdominal Surgery</topic><topic>Cancer surgery</topic><topic>Clinical medicine</topic><topic>Colonoscopy</topic><topic>Colorectal cancer</topic><topic>Colorectal surgery</topic><topic>Endoscopy</topic><topic>Fluorescence</topic><topic>Gastroenterology</topic><topic>Gynecology</topic><topic>Hepatology</topic><topic>Inflammation</topic><topic>Injections</topic><topic>Laparoscopy</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Proctology</topic><topic>Surgery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Satoyoshi, Tetsuta</creatorcontrib><creatorcontrib>Okita, Kenji</creatorcontrib><creatorcontrib>Ishii, Masayuki</creatorcontrib><creatorcontrib>Hamabe, Atsushi</creatorcontrib><creatorcontrib>Usui, Akihiro</creatorcontrib><creatorcontrib>Akizuki, Emi</creatorcontrib><creatorcontrib>Okuya, Koichi</creatorcontrib><creatorcontrib>Nishidate, Toshihiko</creatorcontrib><creatorcontrib>Yamano, Hiroo</creatorcontrib><creatorcontrib>Nakase, Hiroshi</creatorcontrib><creatorcontrib>Takemasa, Ichiro</creatorcontrib><collection>Springer Nature OA Free Journals</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Nursing &amp; Allied Health Database</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Surgical endoscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Satoyoshi, Tetsuta</au><au>Okita, Kenji</au><au>Ishii, Masayuki</au><au>Hamabe, Atsushi</au><au>Usui, Akihiro</au><au>Akizuki, Emi</au><au>Okuya, Koichi</au><au>Nishidate, Toshihiko</au><au>Yamano, Hiroo</au><au>Nakase, Hiroshi</au><au>Takemasa, Ichiro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Timing of indocyanine green injection prior to laparoscopic colorectal surgery for tumor localization: a prospective case series</atitle><jtitle>Surgical endoscopy</jtitle><stitle>Surg Endosc</stitle><addtitle>Surg Endosc</addtitle><date>2021-02-01</date><risdate>2021</risdate><volume>35</volume><issue>2</issue><spage>763</spage><epage>769</epage><pages>763-769</pages><issn>0930-2794</issn><eissn>1432-2218</eissn><abstract>Background Accurate identification of tumor sites during laparoscopic colorectal surgery helps to optimize oncological clearance. We aimed to assess the timing of the local injection preoperatively and clarify the usefulness and limitation of tumor site marking using indocyanine green (ICG) fluorescence imaging. Methods Consecutive patients who underwent primary colorectal cancer surgery from September 2017 to January 2019 were included. Preoperatively, lower endoscopy was used to inject the ICG solution into the submucosal layer near the tumor. During laparoscopic surgery, ICG fluorescence marking as the tumor site marking was detected using a laparoscopic near-infrared camera system. The detection rate and factors associated with successful intraoperative ICG fluorescence visualization including the interval between local injection and surgery were evaluated. Results One hundred sixty-five patients were enrolled. Using the laparoscopic near-infrared system, the intraoperative detection rates of ICG marking were 100% for ICG injection within 6 days preoperatively, 60% for injection between 7 and 9 days preoperatively, and 0% for injection earlier than 10 days preoperatively. There were no complications associated with ICG marking. Additionally, this method did not disturb the progress of the surgical procedure because injected ICG in the submucosal layer did not cause any tissue inflammation, and if ICG spilled into the serosa, it was invisible by white light. Conclusion Advantages of ICG fluorescence tumor site marking were high visibility of infrared imaging during laparoscopic colorectal surgery and minimal adverse events of surgery. One of the most important findings regarding practical use was a rapid decrease in fluorescence marking visibility if one week passed from the time of ICG local injection.</abstract><cop>New York</cop><pub>Springer US</pub><pmid>32072278</pmid><doi>10.1007/s00464-020-07443-5</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0001-8339-6028</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0930-2794
ispartof Surgical endoscopy, 2021-02, Vol.35 (2), p.763-769
issn 0930-2794
1432-2218
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7819920
source SpringerLink Journals - AutoHoldings
subjects Abdominal Surgery
Cancer surgery
Clinical medicine
Colonoscopy
Colorectal cancer
Colorectal surgery
Endoscopy
Fluorescence
Gastroenterology
Gynecology
Hepatology
Inflammation
Injections
Laparoscopy
Medicine
Medicine & Public Health
Proctology
Surgery
title Timing of indocyanine green injection prior to laparoscopic colorectal surgery for tumor localization: a prospective case series
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T18%3A52%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Timing%20of%20indocyanine%20green%20injection%20prior%20to%20laparoscopic%20colorectal%20surgery%20for%20tumor%20localization:%20a%20prospective%20case%20series&rft.jtitle=Surgical%20endoscopy&rft.au=Satoyoshi,%20Tetsuta&rft.date=2021-02-01&rft.volume=35&rft.issue=2&rft.spage=763&rft.epage=769&rft.pages=763-769&rft.issn=0930-2794&rft.eissn=1432-2218&rft_id=info:doi/10.1007/s00464-020-07443-5&rft_dat=%3Cproquest_pubme%3E2358575070%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2479579482&rft_id=info:pmid/32072278&rfr_iscdi=true