Outcomes of a single-step endoscopic ultrasound-guided drainage of pancreatic-fluid collections using an electrocautery-enhanced coaxial lumen-apposing, self-expanding metal stent with and without fluoroscopy

Abstract Background Fluoroscopy is often used during the endoscopic drainage of pancreatic-fluid collections (PFCs). An electrocautery-enhanced coaxial lumen-apposing, self-expanding metal stent (ELAMS) facilitates a single-step procedure and may avoid the need for fluoroscopy. This study compares t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gastroenterology report 2020-12, Vol.8 (6), p.425-430
Hauptverfasser: Olaiya, Babatunde, Mekaroonkamol, Parit, Li, Bai-Wen, Massaad, Julia, Vachaparambil, Cicily T, Xu, Jennifer, Lamm, Vladamir, Luo, Hui, Shen, Shan-Shan, Chen, Hui-Min, Keilin, Steve, Willingham, Field F, Cai, Qiang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 430
container_issue 6
container_start_page 425
container_title Gastroenterology report
container_volume 8
creator Olaiya, Babatunde
Mekaroonkamol, Parit
Li, Bai-Wen
Massaad, Julia
Vachaparambil, Cicily T
Xu, Jennifer
Lamm, Vladamir
Luo, Hui
Shen, Shan-Shan
Chen, Hui-Min
Keilin, Steve
Willingham, Field F
Cai, Qiang
description Abstract Background Fluoroscopy is often used during the endoscopic drainage of pancreatic-fluid collections (PFCs). An electrocautery-enhanced coaxial lumen-apposing, self-expanding metal stent (ELAMS) facilitates a single-step procedure and may avoid the need for fluoroscopy. This study compares the treatment outcomes using ELAMS with and without fluoroscopy. Methods Patients with PFCs who had cystogastrostomy from January 2014 to February 2017 were enrolled. Two groups were studied based on fluoroscopy use. Technical success was defined as uneventful insertion of ELAMS at time of procedure. Clinical success was defined as (i) clinical resolution of symptoms after the procedure and (ii) >75% reduction in cyst size on computed tomography 8 weeks after stent placement. Adverse events including bleeding, stent migration, and infection were recorded. Results A total of 21 patients (13 males) had PFCs drainage with ELAMS in the study period. The mean age was 51.6 ± 14.2 years. Thirteen patients had walled-off necrosis while eight had a pancreatic pseudocyst. The mean size of the PFCs was 11.3 ± 3.3 cm. Fluoroscopy was used in seven cases (33%) and was associated with a longer procedure time compared to non-fluoroscopy (43.1 ± 10.4 vs 33.3 ± 10.5 min, P = 0.025). This association was independent of the size, location, or type of PFCs. Fluoroscopy had no effect on the technical success rates. In fluoroless procedures, the clinical resolution was 91% as compared to 71% in fluoroscopy procedures (P = 0.52) and the radiologic resolution was 57% as compared to 71% in fluoroscopy procedures (P = 0. 65). Three cases of stent migration/displacement occurred in the fluoroless procedures. Conclusions ELAMS may avoid the need for fluoroscopy during cystogastrostomy. Procedures without fluoroscopy were significantly shorter and fluoroscopy use had no impact on the technical or clinical success rates.
doi_str_mv 10.1093/gastro/goaa020
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7793111</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1093/gastro/goaa020</oup_id><sourcerecordid>2478037733</sourcerecordid><originalsourceid>FETCH-LOGICAL-c424t-d3e135d407181fae64c24c4d2a69cdffebc8185c65ab614acc824ba83562b4813</originalsourceid><addsrcrecordid>eNqFkk1v1DAQhiMEolXplSPyESTc2rGzyV6QUAUtUqVe4BxN7EnWyLGDP6D7L_lJON2lKidOHnneeeYdzVTVa84uONuKywliCv5y8gCsZs-q05o1NWVMyOdP4pPqPMbvjDHO2rrhzcvqRAgpa9nK0-r3XU7KzxiJHwmQaNxkkcaEC0GnfVR-MYpkmwJEn52mUzYaNdEBjIMJ17IFnAoIySg62pImyluLKhnvIskrkoAjuH4FryAnDHuKblfKcBXDvQFLbJ7RUVgWv1a8JxHtSPG-wPVKmDEVUTHmEvll0q4g9UPgcyKlrQ8PZvevqhcj2Ijnx_es-vb509erG3p7d_3l6uMtVWXyRLVALhotWcs7PgJupKqlkrqGzVbpccRBdbxr1KaBYcMlKNXVcoBONJt6kB0XZ9WHA3fJw4xaFV8BbL8EM0PY9x5M_2_GmV0_-Z99224F5yvg7REQ_I-MMfWziQqtBYc-x77sp2OibYUo0ouDVJUhY8DxsQ1n_XoJ_eES-uMllII3T809yv_uvQjeHQQ-L_-D_QEiUsh0</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2478037733</pqid></control><display><type>article</type><title>Outcomes of a single-step endoscopic ultrasound-guided drainage of pancreatic-fluid collections using an electrocautery-enhanced coaxial lumen-apposing, self-expanding metal stent with and without fluoroscopy</title><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Oxford Journals Open Access Collection</source><source>PubMed Central</source><creator>Olaiya, Babatunde ; Mekaroonkamol, Parit ; Li, Bai-Wen ; Massaad, Julia ; Vachaparambil, Cicily T ; Xu, Jennifer ; Lamm, Vladamir ; Luo, Hui ; Shen, Shan-Shan ; Chen, Hui-Min ; Keilin, Steve ; Willingham, Field F ; Cai, Qiang</creator><creatorcontrib>Olaiya, Babatunde ; Mekaroonkamol, Parit ; Li, Bai-Wen ; Massaad, Julia ; Vachaparambil, Cicily T ; Xu, Jennifer ; Lamm, Vladamir ; Luo, Hui ; Shen, Shan-Shan ; Chen, Hui-Min ; Keilin, Steve ; Willingham, Field F ; Cai, Qiang</creatorcontrib><description>Abstract Background Fluoroscopy is often used during the endoscopic drainage of pancreatic-fluid collections (PFCs). An electrocautery-enhanced coaxial lumen-apposing, self-expanding metal stent (ELAMS) facilitates a single-step procedure and may avoid the need for fluoroscopy. This study compares the treatment outcomes using ELAMS with and without fluoroscopy. Methods Patients with PFCs who had cystogastrostomy from January 2014 to February 2017 were enrolled. Two groups were studied based on fluoroscopy use. Technical success was defined as uneventful insertion of ELAMS at time of procedure. Clinical success was defined as (i) clinical resolution of symptoms after the procedure and (ii) &gt;75% reduction in cyst size on computed tomography 8 weeks after stent placement. Adverse events including bleeding, stent migration, and infection were recorded. Results A total of 21 patients (13 males) had PFCs drainage with ELAMS in the study period. The mean age was 51.6 ± 14.2 years. Thirteen patients had walled-off necrosis while eight had a pancreatic pseudocyst. The mean size of the PFCs was 11.3 ± 3.3 cm. Fluoroscopy was used in seven cases (33%) and was associated with a longer procedure time compared to non-fluoroscopy (43.1 ± 10.4 vs 33.3 ± 10.5 min, P = 0.025). This association was independent of the size, location, or type of PFCs. Fluoroscopy had no effect on the technical success rates. In fluoroless procedures, the clinical resolution was 91% as compared to 71% in fluoroscopy procedures (P = 0.52) and the radiologic resolution was 57% as compared to 71% in fluoroscopy procedures (P = 0. 65). Three cases of stent migration/displacement occurred in the fluoroless procedures. Conclusions ELAMS may avoid the need for fluoroscopy during cystogastrostomy. Procedures without fluoroscopy were significantly shorter and fluoroscopy use had no impact on the technical or clinical success rates.</description><identifier>ISSN: 2052-0034</identifier><identifier>EISSN: 2052-0034</identifier><identifier>DOI: 10.1093/gastro/goaa020</identifier><identifier>PMID: 33442474</identifier><language>eng</language><publisher>England: Oxford University Press</publisher><subject>Original</subject><ispartof>Gastroenterology report, 2020-12, Vol.8 (6), p.425-430</ispartof><rights>The Author(s) 2020. Published by Oxford University Press and Sixth Affiliated Hospital of Sun Yat-sen University 2020</rights><rights>The Author(s) 2020. Published by Oxford University Press and Sixth Affiliated Hospital of Sun Yat-sen University.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c424t-d3e135d407181fae64c24c4d2a69cdffebc8185c65ab614acc824ba83562b4813</citedby><cites>FETCH-LOGICAL-c424t-d3e135d407181fae64c24c4d2a69cdffebc8185c65ab614acc824ba83562b4813</cites><orcidid>0000-0002-7071-3001</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7793111/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7793111/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,724,777,781,861,882,1599,27905,27906,53772,53774</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33442474$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Olaiya, Babatunde</creatorcontrib><creatorcontrib>Mekaroonkamol, Parit</creatorcontrib><creatorcontrib>Li, Bai-Wen</creatorcontrib><creatorcontrib>Massaad, Julia</creatorcontrib><creatorcontrib>Vachaparambil, Cicily T</creatorcontrib><creatorcontrib>Xu, Jennifer</creatorcontrib><creatorcontrib>Lamm, Vladamir</creatorcontrib><creatorcontrib>Luo, Hui</creatorcontrib><creatorcontrib>Shen, Shan-Shan</creatorcontrib><creatorcontrib>Chen, Hui-Min</creatorcontrib><creatorcontrib>Keilin, Steve</creatorcontrib><creatorcontrib>Willingham, Field F</creatorcontrib><creatorcontrib>Cai, Qiang</creatorcontrib><title>Outcomes of a single-step endoscopic ultrasound-guided drainage of pancreatic-fluid collections using an electrocautery-enhanced coaxial lumen-apposing, self-expanding metal stent with and without fluoroscopy</title><title>Gastroenterology report</title><addtitle>Gastroenterol Rep (Oxf)</addtitle><description>Abstract Background Fluoroscopy is often used during the endoscopic drainage of pancreatic-fluid collections (PFCs). An electrocautery-enhanced coaxial lumen-apposing, self-expanding metal stent (ELAMS) facilitates a single-step procedure and may avoid the need for fluoroscopy. This study compares the treatment outcomes using ELAMS with and without fluoroscopy. Methods Patients with PFCs who had cystogastrostomy from January 2014 to February 2017 were enrolled. Two groups were studied based on fluoroscopy use. Technical success was defined as uneventful insertion of ELAMS at time of procedure. Clinical success was defined as (i) clinical resolution of symptoms after the procedure and (ii) &gt;75% reduction in cyst size on computed tomography 8 weeks after stent placement. Adverse events including bleeding, stent migration, and infection were recorded. Results A total of 21 patients (13 males) had PFCs drainage with ELAMS in the study period. The mean age was 51.6 ± 14.2 years. Thirteen patients had walled-off necrosis while eight had a pancreatic pseudocyst. The mean size of the PFCs was 11.3 ± 3.3 cm. Fluoroscopy was used in seven cases (33%) and was associated with a longer procedure time compared to non-fluoroscopy (43.1 ± 10.4 vs 33.3 ± 10.5 min, P = 0.025). This association was independent of the size, location, or type of PFCs. Fluoroscopy had no effect on the technical success rates. In fluoroless procedures, the clinical resolution was 91% as compared to 71% in fluoroscopy procedures (P = 0.52) and the radiologic resolution was 57% as compared to 71% in fluoroscopy procedures (P = 0. 65). Three cases of stent migration/displacement occurred in the fluoroless procedures. Conclusions ELAMS may avoid the need for fluoroscopy during cystogastrostomy. Procedures without fluoroscopy were significantly shorter and fluoroscopy use had no impact on the technical or clinical success rates.</description><subject>Original</subject><issn>2052-0034</issn><issn>2052-0034</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>TOX</sourceid><recordid>eNqFkk1v1DAQhiMEolXplSPyESTc2rGzyV6QUAUtUqVe4BxN7EnWyLGDP6D7L_lJON2lKidOHnneeeYdzVTVa84uONuKywliCv5y8gCsZs-q05o1NWVMyOdP4pPqPMbvjDHO2rrhzcvqRAgpa9nK0-r3XU7KzxiJHwmQaNxkkcaEC0GnfVR-MYpkmwJEn52mUzYaNdEBjIMJ17IFnAoIySg62pImyluLKhnvIskrkoAjuH4FryAnDHuKblfKcBXDvQFLbJ7RUVgWv1a8JxHtSPG-wPVKmDEVUTHmEvll0q4g9UPgcyKlrQ8PZvevqhcj2Ijnx_es-vb509erG3p7d_3l6uMtVWXyRLVALhotWcs7PgJupKqlkrqGzVbpccRBdbxr1KaBYcMlKNXVcoBONJt6kB0XZ9WHA3fJw4xaFV8BbL8EM0PY9x5M_2_GmV0_-Z99224F5yvg7REQ_I-MMfWziQqtBYc-x77sp2OibYUo0ouDVJUhY8DxsQ1n_XoJ_eES-uMllII3T809yv_uvQjeHQQ-L_-D_QEiUsh0</recordid><startdate>20201201</startdate><enddate>20201201</enddate><creator>Olaiya, Babatunde</creator><creator>Mekaroonkamol, Parit</creator><creator>Li, Bai-Wen</creator><creator>Massaad, Julia</creator><creator>Vachaparambil, Cicily T</creator><creator>Xu, Jennifer</creator><creator>Lamm, Vladamir</creator><creator>Luo, Hui</creator><creator>Shen, Shan-Shan</creator><creator>Chen, Hui-Min</creator><creator>Keilin, Steve</creator><creator>Willingham, Field F</creator><creator>Cai, Qiang</creator><general>Oxford University Press</general><scope>TOX</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-7071-3001</orcidid></search><sort><creationdate>20201201</creationdate><title>Outcomes of a single-step endoscopic ultrasound-guided drainage of pancreatic-fluid collections using an electrocautery-enhanced coaxial lumen-apposing, self-expanding metal stent with and without fluoroscopy</title><author>Olaiya, Babatunde ; Mekaroonkamol, Parit ; Li, Bai-Wen ; Massaad, Julia ; Vachaparambil, Cicily T ; Xu, Jennifer ; Lamm, Vladamir ; Luo, Hui ; Shen, Shan-Shan ; Chen, Hui-Min ; Keilin, Steve ; Willingham, Field F ; Cai, Qiang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c424t-d3e135d407181fae64c24c4d2a69cdffebc8185c65ab614acc824ba83562b4813</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Original</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Olaiya, Babatunde</creatorcontrib><creatorcontrib>Mekaroonkamol, Parit</creatorcontrib><creatorcontrib>Li, Bai-Wen</creatorcontrib><creatorcontrib>Massaad, Julia</creatorcontrib><creatorcontrib>Vachaparambil, Cicily T</creatorcontrib><creatorcontrib>Xu, Jennifer</creatorcontrib><creatorcontrib>Lamm, Vladamir</creatorcontrib><creatorcontrib>Luo, Hui</creatorcontrib><creatorcontrib>Shen, Shan-Shan</creatorcontrib><creatorcontrib>Chen, Hui-Min</creatorcontrib><creatorcontrib>Keilin, Steve</creatorcontrib><creatorcontrib>Willingham, Field F</creatorcontrib><creatorcontrib>Cai, Qiang</creatorcontrib><collection>Oxford Journals Open Access Collection</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Gastroenterology report</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Olaiya, Babatunde</au><au>Mekaroonkamol, Parit</au><au>Li, Bai-Wen</au><au>Massaad, Julia</au><au>Vachaparambil, Cicily T</au><au>Xu, Jennifer</au><au>Lamm, Vladamir</au><au>Luo, Hui</au><au>Shen, Shan-Shan</au><au>Chen, Hui-Min</au><au>Keilin, Steve</au><au>Willingham, Field F</au><au>Cai, Qiang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Outcomes of a single-step endoscopic ultrasound-guided drainage of pancreatic-fluid collections using an electrocautery-enhanced coaxial lumen-apposing, self-expanding metal stent with and without fluoroscopy</atitle><jtitle>Gastroenterology report</jtitle><addtitle>Gastroenterol Rep (Oxf)</addtitle><date>2020-12-01</date><risdate>2020</risdate><volume>8</volume><issue>6</issue><spage>425</spage><epage>430</epage><pages>425-430</pages><issn>2052-0034</issn><eissn>2052-0034</eissn><abstract>Abstract Background Fluoroscopy is often used during the endoscopic drainage of pancreatic-fluid collections (PFCs). An electrocautery-enhanced coaxial lumen-apposing, self-expanding metal stent (ELAMS) facilitates a single-step procedure and may avoid the need for fluoroscopy. This study compares the treatment outcomes using ELAMS with and without fluoroscopy. Methods Patients with PFCs who had cystogastrostomy from January 2014 to February 2017 were enrolled. Two groups were studied based on fluoroscopy use. Technical success was defined as uneventful insertion of ELAMS at time of procedure. Clinical success was defined as (i) clinical resolution of symptoms after the procedure and (ii) &gt;75% reduction in cyst size on computed tomography 8 weeks after stent placement. Adverse events including bleeding, stent migration, and infection were recorded. Results A total of 21 patients (13 males) had PFCs drainage with ELAMS in the study period. The mean age was 51.6 ± 14.2 years. Thirteen patients had walled-off necrosis while eight had a pancreatic pseudocyst. The mean size of the PFCs was 11.3 ± 3.3 cm. Fluoroscopy was used in seven cases (33%) and was associated with a longer procedure time compared to non-fluoroscopy (43.1 ± 10.4 vs 33.3 ± 10.5 min, P = 0.025). This association was independent of the size, location, or type of PFCs. Fluoroscopy had no effect on the technical success rates. In fluoroless procedures, the clinical resolution was 91% as compared to 71% in fluoroscopy procedures (P = 0.52) and the radiologic resolution was 57% as compared to 71% in fluoroscopy procedures (P = 0. 65). Three cases of stent migration/displacement occurred in the fluoroless procedures. Conclusions ELAMS may avoid the need for fluoroscopy during cystogastrostomy. Procedures without fluoroscopy were significantly shorter and fluoroscopy use had no impact on the technical or clinical success rates.</abstract><cop>England</cop><pub>Oxford University Press</pub><pmid>33442474</pmid><doi>10.1093/gastro/goaa020</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0002-7071-3001</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2052-0034
ispartof Gastroenterology report, 2020-12, Vol.8 (6), p.425-430
issn 2052-0034
2052-0034
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7793111
source DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Oxford Journals Open Access Collection; PubMed Central
subjects Original
title Outcomes of a single-step endoscopic ultrasound-guided drainage of pancreatic-fluid collections using an electrocautery-enhanced coaxial lumen-apposing, self-expanding metal stent with and without fluoroscopy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T16%3A57%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Outcomes%20of%20a%20single-step%20endoscopic%20ultrasound-guided%20drainage%20of%20pancreatic-fluid%20collections%20using%20an%20electrocautery-enhanced%20coaxial%20lumen-apposing,%20self-expanding%20metal%20stent%20with%20and%20without%20fluoroscopy&rft.jtitle=Gastroenterology%20report&rft.au=Olaiya,%20Babatunde&rft.date=2020-12-01&rft.volume=8&rft.issue=6&rft.spage=425&rft.epage=430&rft.pages=425-430&rft.issn=2052-0034&rft.eissn=2052-0034&rft_id=info:doi/10.1093/gastro/goaa020&rft_dat=%3Cproquest_pubme%3E2478037733%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2478037733&rft_id=info:pmid/33442474&rft_oup_id=10.1093/gastro/goaa020&rfr_iscdi=true