Diagnostic value of diffusion-weighted imaging with synthetic b-values in breast tumors: comparison with dynamic contrast-enhanced and multiparametric MRI
Objectives To assess DWI for tumor visibility and breast cancer detection by the addition of different synthetic b-values. Methods Eighty-four consecutive women who underwent a breast-multiparametric-MRI (mpMRI) with enhancing lesions on DCE-MRI (BI-RADS 2–5) were included in this IRB-approved retro...
Gespeichert in:
Veröffentlicht in: | European radiology 2021-01, Vol.31 (1), p.356-367 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objectives
To assess DWI for tumor visibility and breast cancer detection by the addition of different synthetic b-values.
Methods
Eighty-four consecutive women who underwent a breast-multiparametric-MRI (mpMRI) with enhancing lesions on DCE-MRI (BI-RADS 2–5) were included in this IRB-approved retrospective study from September 2018 to March 2019. Three readers evaluated DW acquired b-800 and synthetic b-1000, b-1200, b-1500, and b-1800 s/mm
2
images for lesion visibility and preferred b-value based on lesion conspicuity. Image quality (1–3 scores) and breast composition (BI-RADS) were also recorded. Diagnostic parameters for DWI were determined using a 1–5 malignancy score based on qualitative imaging parameters (acquired + preferred synthetic b-values) and ADC values. BI-RADS classification was used for DCE-MRI and quantitative ADC values + BI-RADS were used for mpMRI.
Results
Sixty-four malignant (average = 23 mm) and 39 benign (average = 8 mm) lesions were found in 80 women. Although b-800 achieved the best image quality score, synthetic b-values 1200–1500 s/mm
2
were preferred for lesion conspicuity, especially in dense breast. b-800 and synthetic b-1000/b-1200 s/mm
2
values allowed the visualization of 84–90% of cancers visible with DCE-MRI performing better than b-1500/b-1800 s/mm
2
. DWI was more specific (86.3% vs 65.7%,
p
< 0.001) but less sensitive (62.8% vs 90%,
p
< 0.001) and accurate (71% vs 80.7%,
p
= 0.003) than DCE-MRI for breast cancer detection, where mpMRI was the most accurate modality accounting for less false positive cases.
Conclusion
The addition of synthetic b-values enhances tumor conspicuity and could potentially improve tumor visualization particularly in dense breast. However, its supportive role for DWI breast cancer detection is still not definite.
Key Points
•
The addition of synthetic b-values (1200–1500 s/mm
2
) to acquired DWI afforded a better lesion conspicuity without increasing acquisition time and was particularly useful in dense breasts.
•
Despite the use of synthetic b-values, DWI was less sensitive and accurate than DCE-MRI for breast cancer detection.
•
A multiparametric MRI modality still remains the best approach having the highest accuracy for breast cancer detection and thus reducing the number of unnecessary biopsies. |
---|---|
ISSN: | 0938-7994 1432-1084 |
DOI: | 10.1007/s00330-020-07094-z |