Limiting Outward Flow From the Patient’s Airways to the Airway Operator: Head Chamber for Intubation of COVID-19 Patients
We present the prototype of an adjunct to personal protective equipment (PPE) for intubation of patients with coronavirus disease 2019 (COVID-19). Acknowledging the risk of infection for the airway operator and personnel in the room when tracheal intubation is required for a COVID-19 patient, we des...
Gespeichert in:
Veröffentlicht in: | Curēus (Palo Alto, CA) CA), 2020-10, Vol.12 (10), p.e11153-e11153 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | e11153 |
---|---|
container_issue | 10 |
container_start_page | e11153 |
container_title | Curēus (Palo Alto, CA) |
container_volume | 12 |
creator | Riveros Perez, Efrain Munoz-Monaco, Gustavo M Parvus-Teichmann, Chad C Diaz-Galdo, Roberto J Rocuts, Alexander |
description | We present the prototype of an adjunct to personal protective equipment (PPE) for intubation of patients with coronavirus disease 2019 (COVID-19). Acknowledging the risk of infection for the airway operator and personnel in the room when tracheal intubation is required for a COVID-19 patient, we designed a chamber that creates a microenvironment around the patient’s head that limits the outward flow from a patient’s airways to the airway operator with a filtered suction system in order to limit viral spread and lower contamination risk during intubation in non-negative-pressure rooms. The device was successfully tested in a simulation setting. |
doi_str_mv | 10.7759/cureus.11153 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7686930</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2465754345</sourcerecordid><originalsourceid>FETCH-LOGICAL-c248t-c3f04415f6e1bea64098f3fd3f6b24cf8fe01f91da1a6a041f80ca6f7559b4ef3</originalsourceid><addsrcrecordid>eNpVkb9OwzAYxC0Eoqh04wE8MpBix3-SMCBVhdJKlcoArJaT2K1REhfboapYeA1ejyehtAXB9N2nO_1uOADOMOonCcsui9ap1vcxxowcgJMY8zRKcUoP_-gO6Hn_jBDCKIlRgo5Bh5CYYcTjE_A2NbUJppnDWRtW0pVwVNkVHDlbw7BQ8F4Go5rw-f7h4cC4lVx7GOzW2r1wtlROBuuu4FjJEg4Xss6Vg9o6OGlCm28AtoFWw-HsaXIT4eyH6U_BkZaVV7397YLH0e3DcBxNZ3eT4WAaFTFNQ1QQjSjFTHOFcyU5RVmqiS6J5nlMC51qhbDOcCmx5BJRrFNUSK4TxrKcKk264HrHXbZ5rcpi0-1kJZbO1NKthZVG_HcasxBz-yoSnvKMoA3gfA9w9qVVPoja-EJVlWyUbb2IKWcJo4SyTfRiFy2c9d4p_VuDkfieTOwmE9vJyBef2Yvj</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2465754345</pqid></control><display><type>article</type><title>Limiting Outward Flow From the Patient’s Airways to the Airway Operator: Head Chamber for Intubation of COVID-19 Patients</title><source>PubMed Central</source><source>PubMed Central Open Access</source><creator>Riveros Perez, Efrain ; Munoz-Monaco, Gustavo M ; Parvus-Teichmann, Chad C ; Diaz-Galdo, Roberto J ; Rocuts, Alexander</creator><creatorcontrib>Riveros Perez, Efrain ; Munoz-Monaco, Gustavo M ; Parvus-Teichmann, Chad C ; Diaz-Galdo, Roberto J ; Rocuts, Alexander</creatorcontrib><description>We present the prototype of an adjunct to personal protective equipment (PPE) for intubation of patients with coronavirus disease 2019 (COVID-19). Acknowledging the risk of infection for the airway operator and personnel in the room when tracheal intubation is required for a COVID-19 patient, we designed a chamber that creates a microenvironment around the patient’s head that limits the outward flow from a patient’s airways to the airway operator with a filtered suction system in order to limit viral spread and lower contamination risk during intubation in non-negative-pressure rooms. The device was successfully tested in a simulation setting.</description><identifier>ISSN: 2168-8184</identifier><identifier>EISSN: 2168-8184</identifier><identifier>DOI: 10.7759/cureus.11153</identifier><identifier>PMID: 33251062</identifier><language>eng</language><publisher>Palo Alto (CA): Cureus</publisher><subject>Anesthesiology</subject><ispartof>Curēus (Palo Alto, CA), 2020-10, Vol.12 (10), p.e11153-e11153</ispartof><rights>Copyright © 2020, Riveros Perez et al. 2020 Riveros Perez et al.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c248t-c3f04415f6e1bea64098f3fd3f6b24cf8fe01f91da1a6a041f80ca6f7559b4ef3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7686930/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7686930/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,27901,27902,53766,53768</link.rule.ids></links><search><creatorcontrib>Riveros Perez, Efrain</creatorcontrib><creatorcontrib>Munoz-Monaco, Gustavo M</creatorcontrib><creatorcontrib>Parvus-Teichmann, Chad C</creatorcontrib><creatorcontrib>Diaz-Galdo, Roberto J</creatorcontrib><creatorcontrib>Rocuts, Alexander</creatorcontrib><title>Limiting Outward Flow From the Patient’s Airways to the Airway Operator: Head Chamber for Intubation of COVID-19 Patients</title><title>Curēus (Palo Alto, CA)</title><description>We present the prototype of an adjunct to personal protective equipment (PPE) for intubation of patients with coronavirus disease 2019 (COVID-19). Acknowledging the risk of infection for the airway operator and personnel in the room when tracheal intubation is required for a COVID-19 patient, we designed a chamber that creates a microenvironment around the patient’s head that limits the outward flow from a patient’s airways to the airway operator with a filtered suction system in order to limit viral spread and lower contamination risk during intubation in non-negative-pressure rooms. The device was successfully tested in a simulation setting.</description><subject>Anesthesiology</subject><issn>2168-8184</issn><issn>2168-8184</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNpVkb9OwzAYxC0Eoqh04wE8MpBix3-SMCBVhdJKlcoArJaT2K1REhfboapYeA1ejyehtAXB9N2nO_1uOADOMOonCcsui9ap1vcxxowcgJMY8zRKcUoP_-gO6Hn_jBDCKIlRgo5Bh5CYYcTjE_A2NbUJppnDWRtW0pVwVNkVHDlbw7BQ8F4Go5rw-f7h4cC4lVx7GOzW2r1wtlROBuuu4FjJEg4Xss6Vg9o6OGlCm28AtoFWw-HsaXIT4eyH6U_BkZaVV7397YLH0e3DcBxNZ3eT4WAaFTFNQ1QQjSjFTHOFcyU5RVmqiS6J5nlMC51qhbDOcCmx5BJRrFNUSK4TxrKcKk264HrHXbZ5rcpi0-1kJZbO1NKthZVG_HcasxBz-yoSnvKMoA3gfA9w9qVVPoja-EJVlWyUbb2IKWcJo4SyTfRiFy2c9d4p_VuDkfieTOwmE9vJyBef2Yvj</recordid><startdate>20201025</startdate><enddate>20201025</enddate><creator>Riveros Perez, Efrain</creator><creator>Munoz-Monaco, Gustavo M</creator><creator>Parvus-Teichmann, Chad C</creator><creator>Diaz-Galdo, Roberto J</creator><creator>Rocuts, Alexander</creator><general>Cureus</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20201025</creationdate><title>Limiting Outward Flow From the Patient’s Airways to the Airway Operator: Head Chamber for Intubation of COVID-19 Patients</title><author>Riveros Perez, Efrain ; Munoz-Monaco, Gustavo M ; Parvus-Teichmann, Chad C ; Diaz-Galdo, Roberto J ; Rocuts, Alexander</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c248t-c3f04415f6e1bea64098f3fd3f6b24cf8fe01f91da1a6a041f80ca6f7559b4ef3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Anesthesiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Riveros Perez, Efrain</creatorcontrib><creatorcontrib>Munoz-Monaco, Gustavo M</creatorcontrib><creatorcontrib>Parvus-Teichmann, Chad C</creatorcontrib><creatorcontrib>Diaz-Galdo, Roberto J</creatorcontrib><creatorcontrib>Rocuts, Alexander</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Curēus (Palo Alto, CA)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Riveros Perez, Efrain</au><au>Munoz-Monaco, Gustavo M</au><au>Parvus-Teichmann, Chad C</au><au>Diaz-Galdo, Roberto J</au><au>Rocuts, Alexander</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Limiting Outward Flow From the Patient’s Airways to the Airway Operator: Head Chamber for Intubation of COVID-19 Patients</atitle><jtitle>Curēus (Palo Alto, CA)</jtitle><date>2020-10-25</date><risdate>2020</risdate><volume>12</volume><issue>10</issue><spage>e11153</spage><epage>e11153</epage><pages>e11153-e11153</pages><issn>2168-8184</issn><eissn>2168-8184</eissn><abstract>We present the prototype of an adjunct to personal protective equipment (PPE) for intubation of patients with coronavirus disease 2019 (COVID-19). Acknowledging the risk of infection for the airway operator and personnel in the room when tracheal intubation is required for a COVID-19 patient, we designed a chamber that creates a microenvironment around the patient’s head that limits the outward flow from a patient’s airways to the airway operator with a filtered suction system in order to limit viral spread and lower contamination risk during intubation in non-negative-pressure rooms. The device was successfully tested in a simulation setting.</abstract><cop>Palo Alto (CA)</cop><pub>Cureus</pub><pmid>33251062</pmid><doi>10.7759/cureus.11153</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2168-8184 |
ispartof | Curēus (Palo Alto, CA), 2020-10, Vol.12 (10), p.e11153-e11153 |
issn | 2168-8184 2168-8184 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7686930 |
source | PubMed Central; PubMed Central Open Access |
subjects | Anesthesiology |
title | Limiting Outward Flow From the Patient’s Airways to the Airway Operator: Head Chamber for Intubation of COVID-19 Patients |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-06T16%3A37%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Limiting%20Outward%20Flow%20From%20the%20Patient%E2%80%99s%20Airways%20to%20the%20Airway%20Operator:%20Head%20Chamber%20for%20Intubation%20of%20COVID-19%20Patients&rft.jtitle=Cur%C4%93us%20(Palo%20Alto,%20CA)&rft.au=Riveros%20Perez,%20Efrain&rft.date=2020-10-25&rft.volume=12&rft.issue=10&rft.spage=e11153&rft.epage=e11153&rft.pages=e11153-e11153&rft.issn=2168-8184&rft.eissn=2168-8184&rft_id=info:doi/10.7759/cureus.11153&rft_dat=%3Cproquest_pubme%3E2465754345%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2465754345&rft_id=info:pmid/33251062&rfr_iscdi=true |