Microfluidic Device Using a Gold Pillar Array and Integrated Electrodes for On‐chip Endothelial Cell Immobilization, Direct RBC Contact, and Amperometric Detection of Nitric Oxide

We describe a microfluidic device that can be used to detect interactions between red blood cells (RBCs) and endothelial cells using a gold pillar array (created by electrodeposition) and an integrated detection electrode. Endothelial cells can release nitric oxide (NO) via stimulation by RBC‐derive...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electroanalysis (New York, N.Y.) N.Y.), 2019-08, Vol.31 (8), p.1426-1432
Hauptverfasser: Townsend, Alexandra D., Sprague, Randy S., Martin, R. Scott
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1432
container_issue 8
container_start_page 1426
container_title Electroanalysis (New York, N.Y.)
container_volume 31
creator Townsend, Alexandra D.
Sprague, Randy S.
Martin, R. Scott
description We describe a microfluidic device that can be used to detect interactions between red blood cells (RBCs) and endothelial cells using a gold pillar array (created by electrodeposition) and an integrated detection electrode. Endothelial cells can release nitric oxide (NO) via stimulation by RBC‐derived ATP. These studies incorporate on‐chip endothelial cell immobilization, direct RBC contact, and detection of NO in a single microfluidic device. In order to study the RBC‐EC interactions, this work used a microfluidic device made of a PDMS chip with two adjacent channels and a polystyrene base with embedded electrodes for creating a membrane (via gold pillars) and detecting NO (at a glassy carbon electrode coated with platinum‐black and Nafion). RBCs were pharmacologically treated with treprostinil in the absence and presence of glybenclamide, and ATP release was determined as was the resultant NO release from endothelial cells. Treprostinil treatment of RBCs resulted in ATP release that stimulated endothelial cells to release on average 1.8±0.2 nM NO per endothelial cell (average±SEM, n=8). Pretreatment of RBCs with glybenclamide inhibited treprostinil‐induced ATP release and, therefore, less NO was produced by the endothelial cells (0.92±0.1 nM NO per endothelial cell, n=7). In the future, this device can be used to study interactions between many other cell types (both adherent and non‐adherent cell lines) and incorporate other detection schemes.
doi_str_mv 10.1002/elan.201900157
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7523885</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2447839978</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4547-ca5acdfc476319b73c81425124c140f5d339a22a7c73b56f2863a48991c4d6d73</originalsourceid><addsrcrecordid>eNqFUU1vEzEQtRCIlsCVs48cuqk_s-sLUtiGEik0CNGz5djexMhrB9tpCSd-An-GP9RfwjapijhxmRnNvPdmNA-A1xiNMULk3HoVxgRhgRDm9RNwijnBFcNIPB1qxFCFqKhPwIucvyKExISJ5-CEEiEEb_Ap-P3R6RQ7v3PGaXhhb5y28Dq7sIYKXkZv4CfnvUpwmpLaQxUMnIdi10kVa-DMW11SNDbDLia4DHc_f-mN28JZMLFsrHfKw9Z6D-d9H1fOux-quBjO4IVLAxV-ftfCNoaidDk7iE_7rU2xtyUdzikDaMDD2MErd-gtvztjX4JnnfLZvnrII3D9fval_VAtlpfzdrqoNOOsrrTiSptOs3pCsVjVVDeYEY4J05ihjhtKhSJE1bqmKz7pSDOhijVCYM3MxNR0BN4edbe7VW-NtqEk5eU2uV6lvYzKyX8nwW3kOt7ImhPaNHwQePMgkOK3nc1F9i7r4SEq2LjLkjBWN1SIIYzA-Agd_Mg52e5xDUby3mt577V89HogiCPh1nm7_w9azhbTq7_cP6lQsBM</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2447839978</pqid></control><display><type>article</type><title>Microfluidic Device Using a Gold Pillar Array and Integrated Electrodes for On‐chip Endothelial Cell Immobilization, Direct RBC Contact, and Amperometric Detection of Nitric Oxide</title><source>Wiley Online Library All Journals</source><creator>Townsend, Alexandra D. ; Sprague, Randy S. ; Martin, R. Scott</creator><creatorcontrib>Townsend, Alexandra D. ; Sprague, Randy S. ; Martin, R. Scott</creatorcontrib><description>We describe a microfluidic device that can be used to detect interactions between red blood cells (RBCs) and endothelial cells using a gold pillar array (created by electrodeposition) and an integrated detection electrode. Endothelial cells can release nitric oxide (NO) via stimulation by RBC‐derived ATP. These studies incorporate on‐chip endothelial cell immobilization, direct RBC contact, and detection of NO in a single microfluidic device. In order to study the RBC‐EC interactions, this work used a microfluidic device made of a PDMS chip with two adjacent channels and a polystyrene base with embedded electrodes for creating a membrane (via gold pillars) and detecting NO (at a glassy carbon electrode coated with platinum‐black and Nafion). RBCs were pharmacologically treated with treprostinil in the absence and presence of glybenclamide, and ATP release was determined as was the resultant NO release from endothelial cells. Treprostinil treatment of RBCs resulted in ATP release that stimulated endothelial cells to release on average 1.8±0.2 nM NO per endothelial cell (average±SEM, n=8). Pretreatment of RBCs with glybenclamide inhibited treprostinil‐induced ATP release and, therefore, less NO was produced by the endothelial cells (0.92±0.1 nM NO per endothelial cell, n=7). In the future, this device can be used to study interactions between many other cell types (both adherent and non‐adherent cell lines) and incorporate other detection schemes.</description><identifier>ISSN: 1040-0397</identifier><identifier>EISSN: 1521-4109</identifier><identifier>DOI: 10.1002/elan.201900157</identifier><identifier>PMID: 32999581</identifier><language>eng</language><subject>amperometry ; cell-to-cell communication ; microfluidies ; nitric oxide</subject><ispartof>Electroanalysis (New York, N.Y.), 2019-08, Vol.31 (8), p.1426-1432</ispartof><rights>2019 Wiley‐VCH Verlag GmbH &amp; Co. KGaA, Weinheim</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4547-ca5acdfc476319b73c81425124c140f5d339a22a7c73b56f2863a48991c4d6d73</citedby><cites>FETCH-LOGICAL-c4547-ca5acdfc476319b73c81425124c140f5d339a22a7c73b56f2863a48991c4d6d73</cites><orcidid>0000-0002-6952-1408</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Felan.201900157$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Felan.201900157$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>230,314,780,784,885,1417,27924,27925,45574,45575</link.rule.ids></links><search><creatorcontrib>Townsend, Alexandra D.</creatorcontrib><creatorcontrib>Sprague, Randy S.</creatorcontrib><creatorcontrib>Martin, R. Scott</creatorcontrib><title>Microfluidic Device Using a Gold Pillar Array and Integrated Electrodes for On‐chip Endothelial Cell Immobilization, Direct RBC Contact, and Amperometric Detection of Nitric Oxide</title><title>Electroanalysis (New York, N.Y.)</title><description>We describe a microfluidic device that can be used to detect interactions between red blood cells (RBCs) and endothelial cells using a gold pillar array (created by electrodeposition) and an integrated detection electrode. Endothelial cells can release nitric oxide (NO) via stimulation by RBC‐derived ATP. These studies incorporate on‐chip endothelial cell immobilization, direct RBC contact, and detection of NO in a single microfluidic device. In order to study the RBC‐EC interactions, this work used a microfluidic device made of a PDMS chip with two adjacent channels and a polystyrene base with embedded electrodes for creating a membrane (via gold pillars) and detecting NO (at a glassy carbon electrode coated with platinum‐black and Nafion). RBCs were pharmacologically treated with treprostinil in the absence and presence of glybenclamide, and ATP release was determined as was the resultant NO release from endothelial cells. Treprostinil treatment of RBCs resulted in ATP release that stimulated endothelial cells to release on average 1.8±0.2 nM NO per endothelial cell (average±SEM, n=8). Pretreatment of RBCs with glybenclamide inhibited treprostinil‐induced ATP release and, therefore, less NO was produced by the endothelial cells (0.92±0.1 nM NO per endothelial cell, n=7). In the future, this device can be used to study interactions between many other cell types (both adherent and non‐adherent cell lines) and incorporate other detection schemes.</description><subject>amperometry</subject><subject>cell-to-cell communication</subject><subject>microfluidies</subject><subject>nitric oxide</subject><issn>1040-0397</issn><issn>1521-4109</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqFUU1vEzEQtRCIlsCVs48cuqk_s-sLUtiGEik0CNGz5djexMhrB9tpCSd-An-GP9RfwjapijhxmRnNvPdmNA-A1xiNMULk3HoVxgRhgRDm9RNwijnBFcNIPB1qxFCFqKhPwIucvyKExISJ5-CEEiEEb_Ap-P3R6RQ7v3PGaXhhb5y28Dq7sIYKXkZv4CfnvUpwmpLaQxUMnIdi10kVa-DMW11SNDbDLia4DHc_f-mN28JZMLFsrHfKw9Z6D-d9H1fOux-quBjO4IVLAxV-ftfCNoaidDk7iE_7rU2xtyUdzikDaMDD2MErd-gtvztjX4JnnfLZvnrII3D9fval_VAtlpfzdrqoNOOsrrTiSptOs3pCsVjVVDeYEY4J05ihjhtKhSJE1bqmKz7pSDOhijVCYM3MxNR0BN4edbe7VW-NtqEk5eU2uV6lvYzKyX8nwW3kOt7ImhPaNHwQePMgkOK3nc1F9i7r4SEq2LjLkjBWN1SIIYzA-Agd_Mg52e5xDUby3mt577V89HogiCPh1nm7_w9azhbTq7_cP6lQsBM</recordid><startdate>201908</startdate><enddate>201908</enddate><creator>Townsend, Alexandra D.</creator><creator>Sprague, Randy S.</creator><creator>Martin, R. Scott</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-6952-1408</orcidid></search><sort><creationdate>201908</creationdate><title>Microfluidic Device Using a Gold Pillar Array and Integrated Electrodes for On‐chip Endothelial Cell Immobilization, Direct RBC Contact, and Amperometric Detection of Nitric Oxide</title><author>Townsend, Alexandra D. ; Sprague, Randy S. ; Martin, R. Scott</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4547-ca5acdfc476319b73c81425124c140f5d339a22a7c73b56f2863a48991c4d6d73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>amperometry</topic><topic>cell-to-cell communication</topic><topic>microfluidies</topic><topic>nitric oxide</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Townsend, Alexandra D.</creatorcontrib><creatorcontrib>Sprague, Randy S.</creatorcontrib><creatorcontrib>Martin, R. Scott</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Electroanalysis (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Townsend, Alexandra D.</au><au>Sprague, Randy S.</au><au>Martin, R. Scott</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Microfluidic Device Using a Gold Pillar Array and Integrated Electrodes for On‐chip Endothelial Cell Immobilization, Direct RBC Contact, and Amperometric Detection of Nitric Oxide</atitle><jtitle>Electroanalysis (New York, N.Y.)</jtitle><date>2019-08</date><risdate>2019</risdate><volume>31</volume><issue>8</issue><spage>1426</spage><epage>1432</epage><pages>1426-1432</pages><issn>1040-0397</issn><eissn>1521-4109</eissn><abstract>We describe a microfluidic device that can be used to detect interactions between red blood cells (RBCs) and endothelial cells using a gold pillar array (created by electrodeposition) and an integrated detection electrode. Endothelial cells can release nitric oxide (NO) via stimulation by RBC‐derived ATP. These studies incorporate on‐chip endothelial cell immobilization, direct RBC contact, and detection of NO in a single microfluidic device. In order to study the RBC‐EC interactions, this work used a microfluidic device made of a PDMS chip with two adjacent channels and a polystyrene base with embedded electrodes for creating a membrane (via gold pillars) and detecting NO (at a glassy carbon electrode coated with platinum‐black and Nafion). RBCs were pharmacologically treated with treprostinil in the absence and presence of glybenclamide, and ATP release was determined as was the resultant NO release from endothelial cells. Treprostinil treatment of RBCs resulted in ATP release that stimulated endothelial cells to release on average 1.8±0.2 nM NO per endothelial cell (average±SEM, n=8). Pretreatment of RBCs with glybenclamide inhibited treprostinil‐induced ATP release and, therefore, less NO was produced by the endothelial cells (0.92±0.1 nM NO per endothelial cell, n=7). In the future, this device can be used to study interactions between many other cell types (both adherent and non‐adherent cell lines) and incorporate other detection schemes.</abstract><pmid>32999581</pmid><doi>10.1002/elan.201900157</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-6952-1408</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1040-0397
ispartof Electroanalysis (New York, N.Y.), 2019-08, Vol.31 (8), p.1426-1432
issn 1040-0397
1521-4109
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7523885
source Wiley Online Library All Journals
subjects amperometry
cell-to-cell communication
microfluidies
nitric oxide
title Microfluidic Device Using a Gold Pillar Array and Integrated Electrodes for On‐chip Endothelial Cell Immobilization, Direct RBC Contact, and Amperometric Detection of Nitric Oxide
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T22%3A06%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Microfluidic%20Device%20Using%20a%20Gold%20Pillar%20Array%20and%20Integrated%20Electrodes%20for%20On%E2%80%90chip%20Endothelial%20Cell%20Immobilization,%20Direct%20RBC%20Contact,%20and%20Amperometric%20Detection%20of%20Nitric%20Oxide&rft.jtitle=Electroanalysis%20(New%20York,%20N.Y.)&rft.au=Townsend,%20Alexandra%20D.&rft.date=2019-08&rft.volume=31&rft.issue=8&rft.spage=1426&rft.epage=1432&rft.pages=1426-1432&rft.issn=1040-0397&rft.eissn=1521-4109&rft_id=info:doi/10.1002/elan.201900157&rft_dat=%3Cproquest_pubme%3E2447839978%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2447839978&rft_id=info:pmid/32999581&rfr_iscdi=true