Reliability of Instantaneous Wave-Free Ratio (iFR) for the Evaluation of Left Main Coronary Artery Lesions

The assessment of the left main coronary artery (LMCA) by coronary angiography has several limitations. The fractional flow reserve (FFR) is useful for the functional evaluation of LMCA stenoses. The instantaneous wave-free ratio (iFR), a resting index, was developed to simplify functional coronary...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical medicine 2019-07, Vol.8 (8), p.1143
Hauptverfasser: De Rosa, Salvatore, Polimeni, Alberto, De Velli, Giovanni, Conte, Micaela, Sorrentino, Sabato, Spaccarotella, Carmen, Mongiardo, Annalisa, Sabatino, Jolanda, Contarini, Marco, Indolfi, Ciro
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 8
container_start_page 1143
container_title Journal of clinical medicine
container_volume 8
creator De Rosa, Salvatore
Polimeni, Alberto
De Velli, Giovanni
Conte, Micaela
Sorrentino, Sabato
Spaccarotella, Carmen
Mongiardo, Annalisa
Sabatino, Jolanda
Contarini, Marco
Indolfi, Ciro
description The assessment of the left main coronary artery (LMCA) by coronary angiography has several limitations. The fractional flow reserve (FFR) is useful for the functional evaluation of LMCA stenoses. The instantaneous wave-free ratio (iFR), a resting index, was developed to simplify functional coronary assessment. However, its performance for LMCA stenoses has yet to be explored. The iFR was measured at rest, and the FFR was measured under maximal hyperemia. We calculated that a sample size of 90 lesions would have provided 90% power at a 5% significance level to detect an Area Under the Curve (AUC) < 0.7 for the iFR to identify FFR-positive stenoses. A total of 91 measurements were performed on angiographically intermediate LMCA stenoses at three centers. The comparison between the iFR and the FFR showed a significant correlation (r = 0.67, < 0.001). At receiver operating characteristic (ROC) analysis, the iFR revealed a good diagnostic performance when compared to the FFR (AUC = 0.84; p < 0.001). A classification agreement between the iFR and the FFR was recorded in 81% of cases. The left ventricular ejection fraction (LVEF) was an independent predictor of the discrepancy between the FFR and iFR values (p = 0.040). The present study is the first demonstrating that the assessment of LMCA stenoses with the instantaneous wave-free ratio is a reliable adenosine-free alternative to classic fractional flow reserve. If confirmed in larger populations, these findings could be of relevance for real world daily practice.
doi_str_mv 10.3390/jcm8081143
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6724021</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2268315418</sourcerecordid><originalsourceid>FETCH-LOGICAL-c378t-c32d9494d57d6f60e7bbef82e07bfbeebe3abc6b71d9695a5924b4704098a9d3</originalsourceid><addsrcrecordid>eNpVkdtKAzEQhoMoVrQ3PoDksgrVnHaTvRGkWBUqQhG8DMnurKZsNzVJC769KfUYQmZIvvlnyI_QKSWXnFfkalEvFVGUCr6HjhiRcky44vt_8gEaxrggeSklGJWHaMApl4QX_Agt5tA5Y13n0gf2LX7oYzJ93uDXEb-YDYynAQDPTXIej9x0fo5bH3B6A3y7Md16e99vK2fQJvxoXI8nPvjehA98ExLkMIOYmXiCDlrTRRh-xWP0PL19ntyPZ093D5Ob2bjmUqV8sqYSlWgK2ZRtSUBaC61iQKRtLYAFbmxdWkmbqqwKU1RMWCGJIJUyVcOP0fVOdrW2S2hq6FMwnV4Ft8wzaW-c_v_Suzf96je6lEwQRrPA6Esg-Pc1xKSXLtbQdbtP0YyVitNCUJXRix1aBx9jgPanDSV6a4_-tSfDZ38H-0G_zeCf-cOMTw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2268315418</pqid></control><display><type>article</type><title>Reliability of Instantaneous Wave-Free Ratio (iFR) for the Evaluation of Left Main Coronary Artery Lesions</title><source>PubMed Central Open Access</source><source>MDPI - Multidisciplinary Digital Publishing Institute</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>De Rosa, Salvatore ; Polimeni, Alberto ; De Velli, Giovanni ; Conte, Micaela ; Sorrentino, Sabato ; Spaccarotella, Carmen ; Mongiardo, Annalisa ; Sabatino, Jolanda ; Contarini, Marco ; Indolfi, Ciro</creator><creatorcontrib>De Rosa, Salvatore ; Polimeni, Alberto ; De Velli, Giovanni ; Conte, Micaela ; Sorrentino, Sabato ; Spaccarotella, Carmen ; Mongiardo, Annalisa ; Sabatino, Jolanda ; Contarini, Marco ; Indolfi, Ciro</creatorcontrib><description>The assessment of the left main coronary artery (LMCA) by coronary angiography has several limitations. The fractional flow reserve (FFR) is useful for the functional evaluation of LMCA stenoses. The instantaneous wave-free ratio (iFR), a resting index, was developed to simplify functional coronary assessment. However, its performance for LMCA stenoses has yet to be explored. The iFR was measured at rest, and the FFR was measured under maximal hyperemia. We calculated that a sample size of 90 lesions would have provided 90% power at a 5% significance level to detect an Area Under the Curve (AUC) &lt; 0.7 for the iFR to identify FFR-positive stenoses. A total of 91 measurements were performed on angiographically intermediate LMCA stenoses at three centers. The comparison between the iFR and the FFR showed a significant correlation (r = 0.67, &lt; 0.001). At receiver operating characteristic (ROC) analysis, the iFR revealed a good diagnostic performance when compared to the FFR (AUC = 0.84; p &lt; 0.001). A classification agreement between the iFR and the FFR was recorded in 81% of cases. The left ventricular ejection fraction (LVEF) was an independent predictor of the discrepancy between the FFR and iFR values (p = 0.040). The present study is the first demonstrating that the assessment of LMCA stenoses with the instantaneous wave-free ratio is a reliable adenosine-free alternative to classic fractional flow reserve. If confirmed in larger populations, these findings could be of relevance for real world daily practice.</description><identifier>ISSN: 2077-0383</identifier><identifier>EISSN: 2077-0383</identifier><identifier>DOI: 10.3390/jcm8081143</identifier><identifier>PMID: 31370353</identifier><language>eng</language><publisher>Switzerland: MDPI</publisher><ispartof>Journal of clinical medicine, 2019-07, Vol.8 (8), p.1143</ispartof><rights>2019 by the authors. 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c378t-c32d9494d57d6f60e7bbef82e07bfbeebe3abc6b71d9695a5924b4704098a9d3</citedby><cites>FETCH-LOGICAL-c378t-c32d9494d57d6f60e7bbef82e07bfbeebe3abc6b71d9695a5924b4704098a9d3</cites><orcidid>0000-0002-9166-3031 ; 0000-0002-6003-8057 ; 0000-0001-5388-942X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6724021/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6724021/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31370353$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>De Rosa, Salvatore</creatorcontrib><creatorcontrib>Polimeni, Alberto</creatorcontrib><creatorcontrib>De Velli, Giovanni</creatorcontrib><creatorcontrib>Conte, Micaela</creatorcontrib><creatorcontrib>Sorrentino, Sabato</creatorcontrib><creatorcontrib>Spaccarotella, Carmen</creatorcontrib><creatorcontrib>Mongiardo, Annalisa</creatorcontrib><creatorcontrib>Sabatino, Jolanda</creatorcontrib><creatorcontrib>Contarini, Marco</creatorcontrib><creatorcontrib>Indolfi, Ciro</creatorcontrib><title>Reliability of Instantaneous Wave-Free Ratio (iFR) for the Evaluation of Left Main Coronary Artery Lesions</title><title>Journal of clinical medicine</title><addtitle>J Clin Med</addtitle><description>The assessment of the left main coronary artery (LMCA) by coronary angiography has several limitations. The fractional flow reserve (FFR) is useful for the functional evaluation of LMCA stenoses. The instantaneous wave-free ratio (iFR), a resting index, was developed to simplify functional coronary assessment. However, its performance for LMCA stenoses has yet to be explored. The iFR was measured at rest, and the FFR was measured under maximal hyperemia. We calculated that a sample size of 90 lesions would have provided 90% power at a 5% significance level to detect an Area Under the Curve (AUC) &lt; 0.7 for the iFR to identify FFR-positive stenoses. A total of 91 measurements were performed on angiographically intermediate LMCA stenoses at three centers. The comparison between the iFR and the FFR showed a significant correlation (r = 0.67, &lt; 0.001). At receiver operating characteristic (ROC) analysis, the iFR revealed a good diagnostic performance when compared to the FFR (AUC = 0.84; p &lt; 0.001). A classification agreement between the iFR and the FFR was recorded in 81% of cases. The left ventricular ejection fraction (LVEF) was an independent predictor of the discrepancy between the FFR and iFR values (p = 0.040). The present study is the first demonstrating that the assessment of LMCA stenoses with the instantaneous wave-free ratio is a reliable adenosine-free alternative to classic fractional flow reserve. If confirmed in larger populations, these findings could be of relevance for real world daily practice.</description><issn>2077-0383</issn><issn>2077-0383</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNpVkdtKAzEQhoMoVrQ3PoDksgrVnHaTvRGkWBUqQhG8DMnurKZsNzVJC769KfUYQmZIvvlnyI_QKSWXnFfkalEvFVGUCr6HjhiRcky44vt_8gEaxrggeSklGJWHaMApl4QX_Agt5tA5Y13n0gf2LX7oYzJ93uDXEb-YDYynAQDPTXIej9x0fo5bH3B6A3y7Md16e99vK2fQJvxoXI8nPvjehA98ExLkMIOYmXiCDlrTRRh-xWP0PL19ntyPZ093D5Ob2bjmUqV8sqYSlWgK2ZRtSUBaC61iQKRtLYAFbmxdWkmbqqwKU1RMWCGJIJUyVcOP0fVOdrW2S2hq6FMwnV4Ft8wzaW-c_v_Suzf96je6lEwQRrPA6Esg-Pc1xKSXLtbQdbtP0YyVitNCUJXRix1aBx9jgPanDSV6a4_-tSfDZ38H-0G_zeCf-cOMTw</recordid><startdate>20190731</startdate><enddate>20190731</enddate><creator>De Rosa, Salvatore</creator><creator>Polimeni, Alberto</creator><creator>De Velli, Giovanni</creator><creator>Conte, Micaela</creator><creator>Sorrentino, Sabato</creator><creator>Spaccarotella, Carmen</creator><creator>Mongiardo, Annalisa</creator><creator>Sabatino, Jolanda</creator><creator>Contarini, Marco</creator><creator>Indolfi, Ciro</creator><general>MDPI</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-9166-3031</orcidid><orcidid>https://orcid.org/0000-0002-6003-8057</orcidid><orcidid>https://orcid.org/0000-0001-5388-942X</orcidid></search><sort><creationdate>20190731</creationdate><title>Reliability of Instantaneous Wave-Free Ratio (iFR) for the Evaluation of Left Main Coronary Artery Lesions</title><author>De Rosa, Salvatore ; Polimeni, Alberto ; De Velli, Giovanni ; Conte, Micaela ; Sorrentino, Sabato ; Spaccarotella, Carmen ; Mongiardo, Annalisa ; Sabatino, Jolanda ; Contarini, Marco ; Indolfi, Ciro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c378t-c32d9494d57d6f60e7bbef82e07bfbeebe3abc6b71d9695a5924b4704098a9d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>De Rosa, Salvatore</creatorcontrib><creatorcontrib>Polimeni, Alberto</creatorcontrib><creatorcontrib>De Velli, Giovanni</creatorcontrib><creatorcontrib>Conte, Micaela</creatorcontrib><creatorcontrib>Sorrentino, Sabato</creatorcontrib><creatorcontrib>Spaccarotella, Carmen</creatorcontrib><creatorcontrib>Mongiardo, Annalisa</creatorcontrib><creatorcontrib>Sabatino, Jolanda</creatorcontrib><creatorcontrib>Contarini, Marco</creatorcontrib><creatorcontrib>Indolfi, Ciro</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of clinical medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>De Rosa, Salvatore</au><au>Polimeni, Alberto</au><au>De Velli, Giovanni</au><au>Conte, Micaela</au><au>Sorrentino, Sabato</au><au>Spaccarotella, Carmen</au><au>Mongiardo, Annalisa</au><au>Sabatino, Jolanda</au><au>Contarini, Marco</au><au>Indolfi, Ciro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reliability of Instantaneous Wave-Free Ratio (iFR) for the Evaluation of Left Main Coronary Artery Lesions</atitle><jtitle>Journal of clinical medicine</jtitle><addtitle>J Clin Med</addtitle><date>2019-07-31</date><risdate>2019</risdate><volume>8</volume><issue>8</issue><spage>1143</spage><pages>1143-</pages><issn>2077-0383</issn><eissn>2077-0383</eissn><abstract>The assessment of the left main coronary artery (LMCA) by coronary angiography has several limitations. The fractional flow reserve (FFR) is useful for the functional evaluation of LMCA stenoses. The instantaneous wave-free ratio (iFR), a resting index, was developed to simplify functional coronary assessment. However, its performance for LMCA stenoses has yet to be explored. The iFR was measured at rest, and the FFR was measured under maximal hyperemia. We calculated that a sample size of 90 lesions would have provided 90% power at a 5% significance level to detect an Area Under the Curve (AUC) &lt; 0.7 for the iFR to identify FFR-positive stenoses. A total of 91 measurements were performed on angiographically intermediate LMCA stenoses at three centers. The comparison between the iFR and the FFR showed a significant correlation (r = 0.67, &lt; 0.001). At receiver operating characteristic (ROC) analysis, the iFR revealed a good diagnostic performance when compared to the FFR (AUC = 0.84; p &lt; 0.001). A classification agreement between the iFR and the FFR was recorded in 81% of cases. The left ventricular ejection fraction (LVEF) was an independent predictor of the discrepancy between the FFR and iFR values (p = 0.040). The present study is the first demonstrating that the assessment of LMCA stenoses with the instantaneous wave-free ratio is a reliable adenosine-free alternative to classic fractional flow reserve. If confirmed in larger populations, these findings could be of relevance for real world daily practice.</abstract><cop>Switzerland</cop><pub>MDPI</pub><pmid>31370353</pmid><doi>10.3390/jcm8081143</doi><orcidid>https://orcid.org/0000-0002-9166-3031</orcidid><orcidid>https://orcid.org/0000-0002-6003-8057</orcidid><orcidid>https://orcid.org/0000-0001-5388-942X</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2077-0383
ispartof Journal of clinical medicine, 2019-07, Vol.8 (8), p.1143
issn 2077-0383
2077-0383
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6724021
source PubMed Central Open Access; MDPI - Multidisciplinary Digital Publishing Institute; EZB-FREE-00999 freely available EZB journals; PubMed Central
title Reliability of Instantaneous Wave-Free Ratio (iFR) for the Evaluation of Left Main Coronary Artery Lesions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T14%3A35%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reliability%20of%20Instantaneous%20Wave-Free%20Ratio%20(iFR)%20for%20the%20Evaluation%20of%20Left%20Main%20Coronary%20Artery%20Lesions&rft.jtitle=Journal%20of%20clinical%20medicine&rft.au=De%20Rosa,%20Salvatore&rft.date=2019-07-31&rft.volume=8&rft.issue=8&rft.spage=1143&rft.pages=1143-&rft.issn=2077-0383&rft.eissn=2077-0383&rft_id=info:doi/10.3390/jcm8081143&rft_dat=%3Cproquest_pubme%3E2268315418%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2268315418&rft_id=info:pmid/31370353&rfr_iscdi=true