The application of a vascular closure device for closing a gastrostomy opening used for procedural access

To study the feasibility of applying the Perclose ProGlide vascular closure device (PPVCD) for closing a gastrostomy opening for procedural access in the swine stomach in order to prevent peritoneal leakage. The study included four experimental groups: one manual suture ( = 10), two manual sutures (...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:British journal of radiology 2019-07, Vol.92 (1099), p.20180837-20180837
Hauptverfasser: Cho, Sung Bum, Kim, Hyoung Rae, Jung, Eui-Chul, Chung, Hwan Hoon, Lee, Seung Hwa, Park, Beom Jin, Sung, Deuk Jae
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 20180837
container_issue 1099
container_start_page 20180837
container_title British journal of radiology
container_volume 92
creator Cho, Sung Bum
Kim, Hyoung Rae
Jung, Eui-Chul
Chung, Hwan Hoon
Lee, Seung Hwa
Park, Beom Jin
Sung, Deuk Jae
description To study the feasibility of applying the Perclose ProGlide vascular closure device (PPVCD) for closing a gastrostomy opening for procedural access in the swine stomach in order to prevent peritoneal leakage. The study included four experimental groups: one manual suture ( = 10), two manual sutures ( = 10), one PPVCD suture ( = 10), and two PPVCD sutures ( = 5). In the two PPVCD sutures group, the "pre-close" technique was used. The leak pressure was measured, and statistical analysis was conducted to compare the leak pressures among the experimental groups. The gastrostomy openings were successfully closed in all experimental groups. The median (range) values of leak pressure (mmHg) for each experimental group were as follows: one manual suture, 86.0 (75.0-110.0); two manual sutures, 98.5 (44.0-130.0); one PPVCD suture, 96.5 (56.0-119.0); and two PPVCD sutures, 98.0 (66.0-104.0). The Mann-Whitney test revealed no statistically significant difference in leak pressure between the manual ( = 20) and PPVCD ( = 15) suture groups. The Kruskal-Wallis test revealed no statistically significant difference in leak pressure among the four experimental groups. The Bonferroni post hoc test also revealed no statistically significant difference in the pairwise comparisons among the groups. Application of PPVCD is feasible for the closure of gastrostomy openings in an animal model and is as effective as a manual suture. In our study, percutaneous closure of gastrostomy opening using PPVCD was possible; animal survival studies and development of specific devices are needed before clinical application.
doi_str_mv 10.1259/bjr.20180837
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6636257</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2233853579</sourcerecordid><originalsourceid>FETCH-LOGICAL-c384t-6039b109e717d0f2ca952f4cfafbec1e61ef536bdff4ddba1fc7dc42df5fee553</originalsourceid><addsrcrecordid>eNpVkctLxDAQxoMo7vq4eZYcPdg1j6ZNL4IsvkDwouAtpMlkjXSbmrQL-9_bdVfR0zAzP775mA-hM0pmlInqqv6IM0aoJJKXe2hKy1xmUpK3fTQlhJQZZVJM0FFKH5tWVOQQTTilgjDJpsi_vAPWXdd4o3sfWhwc1nilkxkaHbFpQhoiYAsrbwC7sB35djFSC536GFIflmscOmg30yGB_ca6GAzYIeoGa2MgpRN04HST4HRXj9Hr3e3L_CF7er5_nN88ZYbLvM8KwquakgpKWlrimNGVYC43TrsaDIWCghO8qK1zubW1ps6U1uTMOuEAhODH6Hqr2w31EqyBth9NqC76pY5rFbRX_zetf1eLsFJFwQsmylHgYicQw-cAqVdLnww0jW4hDEkxxrkUXJTViF5uUTP-IUVwv2coUZt01JiO-klnxM__WvuFf-LgX-vwj6o</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2233853579</pqid></control><display><type>article</type><title>The application of a vascular closure device for closing a gastrostomy opening used for procedural access</title><source>Oxford University Press Journals All Titles (1996-Current)</source><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Cho, Sung Bum ; Kim, Hyoung Rae ; Jung, Eui-Chul ; Chung, Hwan Hoon ; Lee, Seung Hwa ; Park, Beom Jin ; Sung, Deuk Jae</creator><creatorcontrib>Cho, Sung Bum ; Kim, Hyoung Rae ; Jung, Eui-Chul ; Chung, Hwan Hoon ; Lee, Seung Hwa ; Park, Beom Jin ; Sung, Deuk Jae</creatorcontrib><description>To study the feasibility of applying the Perclose ProGlide vascular closure device (PPVCD) for closing a gastrostomy opening for procedural access in the swine stomach in order to prevent peritoneal leakage. The study included four experimental groups: one manual suture ( = 10), two manual sutures ( = 10), one PPVCD suture ( = 10), and two PPVCD sutures ( = 5). In the two PPVCD sutures group, the "pre-close" technique was used. The leak pressure was measured, and statistical analysis was conducted to compare the leak pressures among the experimental groups. The gastrostomy openings were successfully closed in all experimental groups. The median (range) values of leak pressure (mmHg) for each experimental group were as follows: one manual suture, 86.0 (75.0-110.0); two manual sutures, 98.5 (44.0-130.0); one PPVCD suture, 96.5 (56.0-119.0); and two PPVCD sutures, 98.0 (66.0-104.0). The Mann-Whitney test revealed no statistically significant difference in leak pressure between the manual ( = 20) and PPVCD ( = 15) suture groups. The Kruskal-Wallis test revealed no statistically significant difference in leak pressure among the four experimental groups. The Bonferroni post hoc test also revealed no statistically significant difference in the pairwise comparisons among the groups. Application of PPVCD is feasible for the closure of gastrostomy openings in an animal model and is as effective as a manual suture. In our study, percutaneous closure of gastrostomy opening using PPVCD was possible; animal survival studies and development of specific devices are needed before clinical application.</description><identifier>ISSN: 0007-1285</identifier><identifier>EISSN: 1748-880X</identifier><identifier>DOI: 10.1259/bjr.20180837</identifier><identifier>PMID: 31150282</identifier><language>eng</language><publisher>England: The British Institute of Radiology</publisher><subject>Animals ; Equipment Design ; Feasibility Studies ; Gastrostomy - instrumentation ; Gastrostomy - methods ; In Vitro Techniques ; Models, Animal ; Stomach - surgery ; Sutures ; Swine ; Vascular Closure Devices</subject><ispartof>British journal of radiology, 2019-07, Vol.92 (1099), p.20180837-20180837</ispartof><rights>2019 The Authors. Published by the British Institute of Radiology 2019 The Authors</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c384t-6039b109e717d0f2ca952f4cfafbec1e61ef536bdff4ddba1fc7dc42df5fee553</citedby><cites>FETCH-LOGICAL-c384t-6039b109e717d0f2ca952f4cfafbec1e61ef536bdff4ddba1fc7dc42df5fee553</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31150282$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cho, Sung Bum</creatorcontrib><creatorcontrib>Kim, Hyoung Rae</creatorcontrib><creatorcontrib>Jung, Eui-Chul</creatorcontrib><creatorcontrib>Chung, Hwan Hoon</creatorcontrib><creatorcontrib>Lee, Seung Hwa</creatorcontrib><creatorcontrib>Park, Beom Jin</creatorcontrib><creatorcontrib>Sung, Deuk Jae</creatorcontrib><title>The application of a vascular closure device for closing a gastrostomy opening used for procedural access</title><title>British journal of radiology</title><addtitle>Br J Radiol</addtitle><description>To study the feasibility of applying the Perclose ProGlide vascular closure device (PPVCD) for closing a gastrostomy opening for procedural access in the swine stomach in order to prevent peritoneal leakage. The study included four experimental groups: one manual suture ( = 10), two manual sutures ( = 10), one PPVCD suture ( = 10), and two PPVCD sutures ( = 5). In the two PPVCD sutures group, the "pre-close" technique was used. The leak pressure was measured, and statistical analysis was conducted to compare the leak pressures among the experimental groups. The gastrostomy openings were successfully closed in all experimental groups. The median (range) values of leak pressure (mmHg) for each experimental group were as follows: one manual suture, 86.0 (75.0-110.0); two manual sutures, 98.5 (44.0-130.0); one PPVCD suture, 96.5 (56.0-119.0); and two PPVCD sutures, 98.0 (66.0-104.0). The Mann-Whitney test revealed no statistically significant difference in leak pressure between the manual ( = 20) and PPVCD ( = 15) suture groups. The Kruskal-Wallis test revealed no statistically significant difference in leak pressure among the four experimental groups. The Bonferroni post hoc test also revealed no statistically significant difference in the pairwise comparisons among the groups. Application of PPVCD is feasible for the closure of gastrostomy openings in an animal model and is as effective as a manual suture. In our study, percutaneous closure of gastrostomy opening using PPVCD was possible; animal survival studies and development of specific devices are needed before clinical application.</description><subject>Animals</subject><subject>Equipment Design</subject><subject>Feasibility Studies</subject><subject>Gastrostomy - instrumentation</subject><subject>Gastrostomy - methods</subject><subject>In Vitro Techniques</subject><subject>Models, Animal</subject><subject>Stomach - surgery</subject><subject>Sutures</subject><subject>Swine</subject><subject>Vascular Closure Devices</subject><issn>0007-1285</issn><issn>1748-880X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVkctLxDAQxoMo7vq4eZYcPdg1j6ZNL4IsvkDwouAtpMlkjXSbmrQL-9_bdVfR0zAzP775mA-hM0pmlInqqv6IM0aoJJKXe2hKy1xmUpK3fTQlhJQZZVJM0FFKH5tWVOQQTTilgjDJpsi_vAPWXdd4o3sfWhwc1nilkxkaHbFpQhoiYAsrbwC7sB35djFSC536GFIflmscOmg30yGB_ca6GAzYIeoGa2MgpRN04HST4HRXj9Hr3e3L_CF7er5_nN88ZYbLvM8KwquakgpKWlrimNGVYC43TrsaDIWCghO8qK1zubW1ps6U1uTMOuEAhODH6Hqr2w31EqyBth9NqC76pY5rFbRX_zetf1eLsFJFwQsmylHgYicQw-cAqVdLnww0jW4hDEkxxrkUXJTViF5uUTP-IUVwv2coUZt01JiO-klnxM__WvuFf-LgX-vwj6o</recordid><startdate>201907</startdate><enddate>201907</enddate><creator>Cho, Sung Bum</creator><creator>Kim, Hyoung Rae</creator><creator>Jung, Eui-Chul</creator><creator>Chung, Hwan Hoon</creator><creator>Lee, Seung Hwa</creator><creator>Park, Beom Jin</creator><creator>Sung, Deuk Jae</creator><general>The British Institute of Radiology</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>201907</creationdate><title>The application of a vascular closure device for closing a gastrostomy opening used for procedural access</title><author>Cho, Sung Bum ; Kim, Hyoung Rae ; Jung, Eui-Chul ; Chung, Hwan Hoon ; Lee, Seung Hwa ; Park, Beom Jin ; Sung, Deuk Jae</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c384t-6039b109e717d0f2ca952f4cfafbec1e61ef536bdff4ddba1fc7dc42df5fee553</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Animals</topic><topic>Equipment Design</topic><topic>Feasibility Studies</topic><topic>Gastrostomy - instrumentation</topic><topic>Gastrostomy - methods</topic><topic>In Vitro Techniques</topic><topic>Models, Animal</topic><topic>Stomach - surgery</topic><topic>Sutures</topic><topic>Swine</topic><topic>Vascular Closure Devices</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cho, Sung Bum</creatorcontrib><creatorcontrib>Kim, Hyoung Rae</creatorcontrib><creatorcontrib>Jung, Eui-Chul</creatorcontrib><creatorcontrib>Chung, Hwan Hoon</creatorcontrib><creatorcontrib>Lee, Seung Hwa</creatorcontrib><creatorcontrib>Park, Beom Jin</creatorcontrib><creatorcontrib>Sung, Deuk Jae</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>British journal of radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cho, Sung Bum</au><au>Kim, Hyoung Rae</au><au>Jung, Eui-Chul</au><au>Chung, Hwan Hoon</au><au>Lee, Seung Hwa</au><au>Park, Beom Jin</au><au>Sung, Deuk Jae</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The application of a vascular closure device for closing a gastrostomy opening used for procedural access</atitle><jtitle>British journal of radiology</jtitle><addtitle>Br J Radiol</addtitle><date>2019-07</date><risdate>2019</risdate><volume>92</volume><issue>1099</issue><spage>20180837</spage><epage>20180837</epage><pages>20180837-20180837</pages><issn>0007-1285</issn><eissn>1748-880X</eissn><abstract>To study the feasibility of applying the Perclose ProGlide vascular closure device (PPVCD) for closing a gastrostomy opening for procedural access in the swine stomach in order to prevent peritoneal leakage. The study included four experimental groups: one manual suture ( = 10), two manual sutures ( = 10), one PPVCD suture ( = 10), and two PPVCD sutures ( = 5). In the two PPVCD sutures group, the "pre-close" technique was used. The leak pressure was measured, and statistical analysis was conducted to compare the leak pressures among the experimental groups. The gastrostomy openings were successfully closed in all experimental groups. The median (range) values of leak pressure (mmHg) for each experimental group were as follows: one manual suture, 86.0 (75.0-110.0); two manual sutures, 98.5 (44.0-130.0); one PPVCD suture, 96.5 (56.0-119.0); and two PPVCD sutures, 98.0 (66.0-104.0). The Mann-Whitney test revealed no statistically significant difference in leak pressure between the manual ( = 20) and PPVCD ( = 15) suture groups. The Kruskal-Wallis test revealed no statistically significant difference in leak pressure among the four experimental groups. The Bonferroni post hoc test also revealed no statistically significant difference in the pairwise comparisons among the groups. Application of PPVCD is feasible for the closure of gastrostomy openings in an animal model and is as effective as a manual suture. In our study, percutaneous closure of gastrostomy opening using PPVCD was possible; animal survival studies and development of specific devices are needed before clinical application.</abstract><cop>England</cop><pub>The British Institute of Radiology</pub><pmid>31150282</pmid><doi>10.1259/bjr.20180837</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0007-1285
ispartof British journal of radiology, 2019-07, Vol.92 (1099), p.20180837-20180837
issn 0007-1285
1748-880X
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6636257
source Oxford University Press Journals All Titles (1996-Current); MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Animals
Equipment Design
Feasibility Studies
Gastrostomy - instrumentation
Gastrostomy - methods
In Vitro Techniques
Models, Animal
Stomach - surgery
Sutures
Swine
Vascular Closure Devices
title The application of a vascular closure device for closing a gastrostomy opening used for procedural access
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T04%3A30%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20application%20of%20a%20vascular%20closure%20device%20for%20closing%20a%20gastrostomy%20opening%20used%20for%20procedural%20access&rft.jtitle=British%20journal%20of%20radiology&rft.au=Cho,%20Sung%20Bum&rft.date=2019-07&rft.volume=92&rft.issue=1099&rft.spage=20180837&rft.epage=20180837&rft.pages=20180837-20180837&rft.issn=0007-1285&rft.eissn=1748-880X&rft_id=info:doi/10.1259/bjr.20180837&rft_dat=%3Cproquest_pubme%3E2233853579%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2233853579&rft_id=info:pmid/31150282&rfr_iscdi=true