Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement
If conservative treatment of osteoporotic vertebral compression fractures fails, vertebro- or kyphoplasty is indicated. Usually, polymethylmethacrylate cement (PMMA) is applied coming along with many disadvantageous features. Aluminum-free glass-polyalkenoate cement (GPC) appears to be a benefit alt...
Gespeichert in:
Veröffentlicht in: | BioMed research international 2019-01, Vol.2019 (2019), p.1-7 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 7 |
---|---|
container_issue | 2019 |
container_start_page | 1 |
container_title | BioMed research international |
container_volume | 2019 |
creator | Wegmann, Kilian Staat, Manfred Neiss, Wolfram F. Scheyerer, Max J. Leschinger, Tim van Gaalen, Kerstin Meyer, Carolin Müller, Lars P. |
description | If conservative treatment of osteoporotic vertebral compression fractures fails, vertebro- or kyphoplasty is indicated. Usually, polymethylmethacrylate cement (PMMA) is applied coming along with many disadvantageous features. Aluminum-free glass-polyalkenoate cement (GPC) appears to be a benefit alternative material. This study aimed at comparing the mean stress values in human vertebrae after kyphoplasty with PMMA and GPC (IlluminOss™) at hand of a finite element analysis. Three models were created performing kyphoplasty using PMMA or IlluminOss™, respectively, at two native, human lumbar vertebrae (L4) while one remains intact. Finite element analysis was performed using CT-scans of every vertebra. Moreover the PMMA-treated vertebra was used as a model as analyses were executed using material data of PMMA and of GPC. The unimpaired, spongious bone showed potentials of 0.25 MPa maximally. After augmentation stress levels showed fivefold increase, rising from externally to internally, revealing stress peaks at the ventral border of the spinal canal. At central areas of cement 1 MPa is measured in both types of cement. Around these central areas the von Mises stress decreased about 25-50% (0.5-0.75 MPa). If workload of 500 N was applied, the stress appeared to be more centralized at the IlluminOss™-model, similar to the unimpaired. Considering the endplates the GPC model also closely resembles the unimpaired. Comparing the PMMA-treated vertebral body and the GPC-simulation, there is an obvious difference. While the PMMA-treated model showed a central stress peak of 5 MPa, the GPC-simulation of the same vertebral body presents lower stress of 1.2-2.5 MPa. Finite element analysis showed that IlluminOss™ (GPC), used in kyphoplasty of vertebral bodies, creates lower level stress and strain compared to standardly used PMMA, leading to lower stress concentrations on the cranial and caudal vertebral surface especially. GPC appears to own advantageous biological and clinical relevant features. |
doi_str_mv | 10.1155/2019/9232813 |
format | Article |
fullrecord | <record><control><sourceid>gale_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6501275</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A613509595</galeid><sourcerecordid>A613509595</sourcerecordid><originalsourceid>FETCH-LOGICAL-c499t-15779464d28c22d0910deeeac6f93a7be62802125cbf4a35ab4c8a04efd3e85c3</originalsourceid><addsrcrecordid>eNqNkc9v0zAYhiMEYtPYjTOyxAUJyvw7MYdJVbUOxKRdClfLcb6sntI42A5T_nuctXTACV9syY_e1_6eonhN8EdChLigmKgLRRmtCHtWnFJG-EISTp4fz4ydFOcx3uO8KiKxki-LE0YIZ2VZnRbN12nY-qEzMU3It-g2JvCDDz45i9bB2DQGaNB3CAnqYOATWqK1610CdNXBDvqElr3ppugiMrUfE9o8eLSZBohz3OoReVW8aE0X4fywnxXf1leb1efFze31l9XyZmG5UmlBRFkqLnlDK0tpgxXBDQAYK1vFTFmDpBWmhApbt9wwYWpuK4M5tA2DSlh2Vlzuc4ex3kFjc3UwnR6C25kwaW-c_vumd1t9539qKTChpcgB7w4Bwf8YISa9c9FC15ke_Bg1zZPmJVdMZfTtP-i9H0MexUxlLVwyWT5Rd6YD7frW5147h-pldiOwEmqu_bCnbPAxBmiPTyZYz5717FkfPGf8zZ_fPMK_rWbg_R7Yur4xD-4_4yAz0JonmtCKKcV-AaA5uN8</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2220146367</pqid></control><display><type>article</type><title>Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement</title><source>Wiley Online Library Open Access</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><source>PubMed Central Open Access</source><creator>Wegmann, Kilian ; Staat, Manfred ; Neiss, Wolfram F. ; Scheyerer, Max J. ; Leschinger, Tim ; van Gaalen, Kerstin ; Meyer, Carolin ; Müller, Lars P.</creator><contributor>Dunne, Nicholas</contributor><creatorcontrib>Wegmann, Kilian ; Staat, Manfred ; Neiss, Wolfram F. ; Scheyerer, Max J. ; Leschinger, Tim ; van Gaalen, Kerstin ; Meyer, Carolin ; Müller, Lars P. ; Dunne, Nicholas</creatorcontrib><description>If conservative treatment of osteoporotic vertebral compression fractures fails, vertebro- or kyphoplasty is indicated. Usually, polymethylmethacrylate cement (PMMA) is applied coming along with many disadvantageous features. Aluminum-free glass-polyalkenoate cement (GPC) appears to be a benefit alternative material. This study aimed at comparing the mean stress values in human vertebrae after kyphoplasty with PMMA and GPC (IlluminOss™) at hand of a finite element analysis. Three models were created performing kyphoplasty using PMMA or IlluminOss™, respectively, at two native, human lumbar vertebrae (L4) while one remains intact. Finite element analysis was performed using CT-scans of every vertebra. Moreover the PMMA-treated vertebra was used as a model as analyses were executed using material data of PMMA and of GPC. The unimpaired, spongious bone showed potentials of 0.25 MPa maximally. After augmentation stress levels showed fivefold increase, rising from externally to internally, revealing stress peaks at the ventral border of the spinal canal. At central areas of cement 1 MPa is measured in both types of cement. Around these central areas the von Mises stress decreased about 25-50% (0.5-0.75 MPa). If workload of 500 N was applied, the stress appeared to be more centralized at the IlluminOss™-model, similar to the unimpaired. Considering the endplates the GPC model also closely resembles the unimpaired. Comparing the PMMA-treated vertebral body and the GPC-simulation, there is an obvious difference. While the PMMA-treated model showed a central stress peak of 5 MPa, the GPC-simulation of the same vertebral body presents lower stress of 1.2-2.5 MPa. Finite element analysis showed that IlluminOss™ (GPC), used in kyphoplasty of vertebral bodies, creates lower level stress and strain compared to standardly used PMMA, leading to lower stress concentrations on the cranial and caudal vertebral surface especially. GPC appears to own advantageous biological and clinical relevant features.</description><identifier>ISSN: 2314-6133</identifier><identifier>EISSN: 2314-6141</identifier><identifier>DOI: 10.1155/2019/9232813</identifier><identifier>PMID: 31143778</identifier><language>eng</language><publisher>Cairo, Egypt: Hindawi Publishing Corporation</publisher><subject>Aluminum ; Balloon catheters ; Biocompatibility ; Biomechanics ; Care and treatment ; Cement ; Compression ; Computed tomography ; Computer simulation ; Finite element analysis ; Finite element method ; Fractures ; Mathematical analysis ; Mathematical models ; Orthopedic surgery ; Osteoporosis ; Pain ; Polymethyl methacrylate ; Polymethylmethacrylate ; Software ; Stress ; Vertebrae ; Workload</subject><ispartof>BioMed research international, 2019-01, Vol.2019 (2019), p.1-7</ispartof><rights>Copyright © 2019 Carolin Meyer et al.</rights><rights>COPYRIGHT 2019 John Wiley & Sons, Inc.</rights><rights>Copyright © 2019 Carolin Meyer et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. https://creativecommons.org/licenses/by/4.0</rights><rights>Copyright © 2019 Carolin Meyer et al. 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c499t-15779464d28c22d0910deeeac6f93a7be62802125cbf4a35ab4c8a04efd3e85c3</citedby><cites>FETCH-LOGICAL-c499t-15779464d28c22d0910deeeac6f93a7be62802125cbf4a35ab4c8a04efd3e85c3</cites><orcidid>0000-0003-4363-6570 ; 0000-0003-1392-3990 ; 0000-0002-1498-4827 ; 0000-0003-1319-6949</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6501275/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6501275/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31143778$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><contributor>Dunne, Nicholas</contributor><creatorcontrib>Wegmann, Kilian</creatorcontrib><creatorcontrib>Staat, Manfred</creatorcontrib><creatorcontrib>Neiss, Wolfram F.</creatorcontrib><creatorcontrib>Scheyerer, Max J.</creatorcontrib><creatorcontrib>Leschinger, Tim</creatorcontrib><creatorcontrib>van Gaalen, Kerstin</creatorcontrib><creatorcontrib>Meyer, Carolin</creatorcontrib><creatorcontrib>Müller, Lars P.</creatorcontrib><title>Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement</title><title>BioMed research international</title><addtitle>Biomed Res Int</addtitle><description>If conservative treatment of osteoporotic vertebral compression fractures fails, vertebro- or kyphoplasty is indicated. Usually, polymethylmethacrylate cement (PMMA) is applied coming along with many disadvantageous features. Aluminum-free glass-polyalkenoate cement (GPC) appears to be a benefit alternative material. This study aimed at comparing the mean stress values in human vertebrae after kyphoplasty with PMMA and GPC (IlluminOss™) at hand of a finite element analysis. Three models were created performing kyphoplasty using PMMA or IlluminOss™, respectively, at two native, human lumbar vertebrae (L4) while one remains intact. Finite element analysis was performed using CT-scans of every vertebra. Moreover the PMMA-treated vertebra was used as a model as analyses were executed using material data of PMMA and of GPC. The unimpaired, spongious bone showed potentials of 0.25 MPa maximally. After augmentation stress levels showed fivefold increase, rising from externally to internally, revealing stress peaks at the ventral border of the spinal canal. At central areas of cement 1 MPa is measured in both types of cement. Around these central areas the von Mises stress decreased about 25-50% (0.5-0.75 MPa). If workload of 500 N was applied, the stress appeared to be more centralized at the IlluminOss™-model, similar to the unimpaired. Considering the endplates the GPC model also closely resembles the unimpaired. Comparing the PMMA-treated vertebral body and the GPC-simulation, there is an obvious difference. While the PMMA-treated model showed a central stress peak of 5 MPa, the GPC-simulation of the same vertebral body presents lower stress of 1.2-2.5 MPa. Finite element analysis showed that IlluminOss™ (GPC), used in kyphoplasty of vertebral bodies, creates lower level stress and strain compared to standardly used PMMA, leading to lower stress concentrations on the cranial and caudal vertebral surface especially. GPC appears to own advantageous biological and clinical relevant features.</description><subject>Aluminum</subject><subject>Balloon catheters</subject><subject>Biocompatibility</subject><subject>Biomechanics</subject><subject>Care and treatment</subject><subject>Cement</subject><subject>Compression</subject><subject>Computed tomography</subject><subject>Computer simulation</subject><subject>Finite element analysis</subject><subject>Finite element method</subject><subject>Fractures</subject><subject>Mathematical analysis</subject><subject>Mathematical models</subject><subject>Orthopedic surgery</subject><subject>Osteoporosis</subject><subject>Pain</subject><subject>Polymethyl methacrylate</subject><subject>Polymethylmethacrylate</subject><subject>Software</subject><subject>Stress</subject><subject>Vertebrae</subject><subject>Workload</subject><issn>2314-6133</issn><issn>2314-6141</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>RHX</sourceid><sourceid>BENPR</sourceid><recordid>eNqNkc9v0zAYhiMEYtPYjTOyxAUJyvw7MYdJVbUOxKRdClfLcb6sntI42A5T_nuctXTACV9syY_e1_6eonhN8EdChLigmKgLRRmtCHtWnFJG-EISTp4fz4ydFOcx3uO8KiKxki-LE0YIZ2VZnRbN12nY-qEzMU3It-g2JvCDDz45i9bB2DQGaNB3CAnqYOATWqK1610CdNXBDvqElr3ppugiMrUfE9o8eLSZBohz3OoReVW8aE0X4fywnxXf1leb1efFze31l9XyZmG5UmlBRFkqLnlDK0tpgxXBDQAYK1vFTFmDpBWmhApbt9wwYWpuK4M5tA2DSlh2Vlzuc4ex3kFjc3UwnR6C25kwaW-c_vumd1t9539qKTChpcgB7w4Bwf8YISa9c9FC15ke_Bg1zZPmJVdMZfTtP-i9H0MexUxlLVwyWT5Rd6YD7frW5147h-pldiOwEmqu_bCnbPAxBmiPTyZYz5717FkfPGf8zZ_fPMK_rWbg_R7Yur4xD-4_4yAz0JonmtCKKcV-AaA5uN8</recordid><startdate>20190101</startdate><enddate>20190101</enddate><creator>Wegmann, Kilian</creator><creator>Staat, Manfred</creator><creator>Neiss, Wolfram F.</creator><creator>Scheyerer, Max J.</creator><creator>Leschinger, Tim</creator><creator>van Gaalen, Kerstin</creator><creator>Meyer, Carolin</creator><creator>Müller, Lars P.</creator><general>Hindawi Publishing Corporation</general><general>Hindawi</general><general>John Wiley & Sons, Inc</general><general>Hindawi Limited</general><scope>ADJCN</scope><scope>AHFXO</scope><scope>RHU</scope><scope>RHW</scope><scope>RHX</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QL</scope><scope>7QO</scope><scope>7T7</scope><scope>7TK</scope><scope>7U7</scope><scope>7U9</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>C1K</scope><scope>CCPQU</scope><scope>CWDGH</scope><scope>DWQXO</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>H94</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M7N</scope><scope>M7P</scope><scope>P5Z</scope><scope>P62</scope><scope>P64</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0003-4363-6570</orcidid><orcidid>https://orcid.org/0000-0003-1392-3990</orcidid><orcidid>https://orcid.org/0000-0002-1498-4827</orcidid><orcidid>https://orcid.org/0000-0003-1319-6949</orcidid></search><sort><creationdate>20190101</creationdate><title>Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement</title><author>Wegmann, Kilian ; Staat, Manfred ; Neiss, Wolfram F. ; Scheyerer, Max J. ; Leschinger, Tim ; van Gaalen, Kerstin ; Meyer, Carolin ; Müller, Lars P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c499t-15779464d28c22d0910deeeac6f93a7be62802125cbf4a35ab4c8a04efd3e85c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Aluminum</topic><topic>Balloon catheters</topic><topic>Biocompatibility</topic><topic>Biomechanics</topic><topic>Care and treatment</topic><topic>Cement</topic><topic>Compression</topic><topic>Computed tomography</topic><topic>Computer simulation</topic><topic>Finite element analysis</topic><topic>Finite element method</topic><topic>Fractures</topic><topic>Mathematical analysis</topic><topic>Mathematical models</topic><topic>Orthopedic surgery</topic><topic>Osteoporosis</topic><topic>Pain</topic><topic>Polymethyl methacrylate</topic><topic>Polymethylmethacrylate</topic><topic>Software</topic><topic>Stress</topic><topic>Vertebrae</topic><topic>Workload</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wegmann, Kilian</creatorcontrib><creatorcontrib>Staat, Manfred</creatorcontrib><creatorcontrib>Neiss, Wolfram F.</creatorcontrib><creatorcontrib>Scheyerer, Max J.</creatorcontrib><creatorcontrib>Leschinger, Tim</creatorcontrib><creatorcontrib>van Gaalen, Kerstin</creatorcontrib><creatorcontrib>Meyer, Carolin</creatorcontrib><creatorcontrib>Müller, Lars P.</creatorcontrib><collection>الدوريات العلمية والإحصائية - e-Marefa Academic and Statistical Periodicals</collection><collection>معرفة - المحتوى العربي الأكاديمي المتكامل - e-Marefa Academic Complete</collection><collection>Hindawi Publishing Complete</collection><collection>Hindawi Publishing Subscription Journals</collection><collection>Hindawi Publishing Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Biotechnology Research Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Neurosciences Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>Middle East & Africa Database</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biological Science Database</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>BioMed research international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wegmann, Kilian</au><au>Staat, Manfred</au><au>Neiss, Wolfram F.</au><au>Scheyerer, Max J.</au><au>Leschinger, Tim</au><au>van Gaalen, Kerstin</au><au>Meyer, Carolin</au><au>Müller, Lars P.</au><au>Dunne, Nicholas</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement</atitle><jtitle>BioMed research international</jtitle><addtitle>Biomed Res Int</addtitle><date>2019-01-01</date><risdate>2019</risdate><volume>2019</volume><issue>2019</issue><spage>1</spage><epage>7</epage><pages>1-7</pages><issn>2314-6133</issn><eissn>2314-6141</eissn><abstract>If conservative treatment of osteoporotic vertebral compression fractures fails, vertebro- or kyphoplasty is indicated. Usually, polymethylmethacrylate cement (PMMA) is applied coming along with many disadvantageous features. Aluminum-free glass-polyalkenoate cement (GPC) appears to be a benefit alternative material. This study aimed at comparing the mean stress values in human vertebrae after kyphoplasty with PMMA and GPC (IlluminOss™) at hand of a finite element analysis. Three models were created performing kyphoplasty using PMMA or IlluminOss™, respectively, at two native, human lumbar vertebrae (L4) while one remains intact. Finite element analysis was performed using CT-scans of every vertebra. Moreover the PMMA-treated vertebra was used as a model as analyses were executed using material data of PMMA and of GPC. The unimpaired, spongious bone showed potentials of 0.25 MPa maximally. After augmentation stress levels showed fivefold increase, rising from externally to internally, revealing stress peaks at the ventral border of the spinal canal. At central areas of cement 1 MPa is measured in both types of cement. Around these central areas the von Mises stress decreased about 25-50% (0.5-0.75 MPa). If workload of 500 N was applied, the stress appeared to be more centralized at the IlluminOss™-model, similar to the unimpaired. Considering the endplates the GPC model also closely resembles the unimpaired. Comparing the PMMA-treated vertebral body and the GPC-simulation, there is an obvious difference. While the PMMA-treated model showed a central stress peak of 5 MPa, the GPC-simulation of the same vertebral body presents lower stress of 1.2-2.5 MPa. Finite element analysis showed that IlluminOss™ (GPC), used in kyphoplasty of vertebral bodies, creates lower level stress and strain compared to standardly used PMMA, leading to lower stress concentrations on the cranial and caudal vertebral surface especially. GPC appears to own advantageous biological and clinical relevant features.</abstract><cop>Cairo, Egypt</cop><pub>Hindawi Publishing Corporation</pub><pmid>31143778</pmid><doi>10.1155/2019/9232813</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0003-4363-6570</orcidid><orcidid>https://orcid.org/0000-0003-1392-3990</orcidid><orcidid>https://orcid.org/0000-0002-1498-4827</orcidid><orcidid>https://orcid.org/0000-0003-1319-6949</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2314-6133 |
ispartof | BioMed research international, 2019-01, Vol.2019 (2019), p.1-7 |
issn | 2314-6133 2314-6141 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6501275 |
source | Wiley Online Library Open Access; PubMed Central; Alma/SFX Local Collection; PubMed Central Open Access |
subjects | Aluminum Balloon catheters Biocompatibility Biomechanics Care and treatment Cement Compression Computed tomography Computer simulation Finite element analysis Finite element method Fractures Mathematical analysis Mathematical models Orthopedic surgery Osteoporosis Pain Polymethyl methacrylate Polymethylmethacrylate Software Stress Vertebrae Workload |
title | Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T20%3A51%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Kyphoplasty%20of%20Osteoporotic%20Fractured%20Vertebrae:%20A%20Finite%20Element%20Analysis%20about%20Two%20Types%20of%20Cement&rft.jtitle=BioMed%20research%20international&rft.au=Wegmann,%20Kilian&rft.date=2019-01-01&rft.volume=2019&rft.issue=2019&rft.spage=1&rft.epage=7&rft.pages=1-7&rft.issn=2314-6133&rft.eissn=2314-6141&rft_id=info:doi/10.1155/2019/9232813&rft_dat=%3Cgale_pubme%3EA613509595%3C/gale_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2220146367&rft_id=info:pmid/31143778&rft_galeid=A613509595&rfr_iscdi=true |