The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature

Background The universal goniometer is a simple measuring tool. With this review we aimed to investigate the reliability and validity of the universal goniometer in measurements of the adults' elbow. Methods Preferred Reporting Items for Systematic reviews and Meta-Analysis guidelines were foll...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Shoulder & Elbow 2018-10, Vol.10 (4), p.274-284
Hauptverfasser: van Rijn, Suzanne F, Zwerus, Elisa L, Koenraadt, Koen LM, Jacobs, Wilco CH, van den Bekerom, Michel PJ, Eygendaal, Denise
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 284
container_issue 4
container_start_page 274
container_title Shoulder & Elbow
container_volume 10
creator van Rijn, Suzanne F
Zwerus, Elisa L
Koenraadt, Koen LM
Jacobs, Wilco CH
van den Bekerom, Michel PJ
Eygendaal, Denise
description Background The universal goniometer is a simple measuring tool. With this review we aimed to investigate the reliability and validity of the universal goniometer in measurements of the adults' elbow. Methods Preferred Reporting Items for Systematic reviews and Meta-Analysis guidelines were followed and our study protocol was published online at PROSPERO. A literature search was conducted on relevant studies. Methodological quality was assessed using the Quality Appraisal of Diagnostic Reliability (QAREL) scoring system. Results Out of 697 studies yielded from our literature search, 12 were included. Six studies were rated as high quality. The intrarater reliability intraclass correlation coefficient ranged from 0.45 to 0.99, the interrater reliability ranged from intraclass correlation coefficient 0.53–0.97. One study providing instructions on goniometric alignment did not find a difference in expert versus non-expert examiners. Another study in which examiners were not instructed found a higher interrater reliability in expert examiners. One study investigating the validity of the goniometer in elbow measurements found a maximum standard error of the mean of 11.5° for total range of motion. Discussion Overall, the studies showed high intra- and interrater reliability of the universal goniometer. The reliability of the universal goniometer in non-expert examiners can be increased by clear instructions on goniometric alignment.
doi_str_mv 10.1177/1758573218774326
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6134535</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1758573218774326</sage_id><sourcerecordid>2105039548</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3496-44adfb85a97732c2d52714591aaa4bbd8939a1bf17e3deaa0f8de3ded9edccd3</originalsourceid><addsrcrecordid>eNp1kc1v3CAQxVHVqPm891Rx7MUtGDB2D5WiqG0qRcpl72hsxhsibFLAG-1_H6xNV22lnhiGN7954hHynrNPnGv9mWvVKi1q3motRd28IWdrq1JasrfHWtSn5DylR8Ya3Wj1jpwKVnMpO3lGwuYBaUTvoHfe5T2F2dIdeGfXSxjpNswuTJijGyj6PjzTCSEtESecc6JupmAXn9MXek3TPmWcIBdpxJ3D5xWQy4JCxgi5TF2SkxF8wqvX84Jsvn_b3NxWd_c_ft5c31WDkF1TSQl27FsFnS72h9qqWnOpOg4Asu9t24kOeD9yjcIiABtbu1a2QzsMVlyQrwfs09JPpVW8RvDmKboJ4t4EcObvl9k9mG3YmYYLqYQqgI-vgBh-LZiymVwa0HuYMSzJ1JwpJjol2yJlB-kQQ0oRx-Mazswak_k3pjLy4U97x4HfuRRBdRAk2KJ5DEucy2_9H_gCHEWejA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2105039548</pqid></control><display><type>article</type><title>The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature</title><source>Access via SAGE</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>van Rijn, Suzanne F ; Zwerus, Elisa L ; Koenraadt, Koen LM ; Jacobs, Wilco CH ; van den Bekerom, Michel PJ ; Eygendaal, Denise</creator><creatorcontrib>van Rijn, Suzanne F ; Zwerus, Elisa L ; Koenraadt, Koen LM ; Jacobs, Wilco CH ; van den Bekerom, Michel PJ ; Eygendaal, Denise</creatorcontrib><description>Background The universal goniometer is a simple measuring tool. With this review we aimed to investigate the reliability and validity of the universal goniometer in measurements of the adults' elbow. Methods Preferred Reporting Items for Systematic reviews and Meta-Analysis guidelines were followed and our study protocol was published online at PROSPERO. A literature search was conducted on relevant studies. Methodological quality was assessed using the Quality Appraisal of Diagnostic Reliability (QAREL) scoring system. Results Out of 697 studies yielded from our literature search, 12 were included. Six studies were rated as high quality. The intrarater reliability intraclass correlation coefficient ranged from 0.45 to 0.99, the interrater reliability ranged from intraclass correlation coefficient 0.53–0.97. One study providing instructions on goniometric alignment did not find a difference in expert versus non-expert examiners. Another study in which examiners were not instructed found a higher interrater reliability in expert examiners. One study investigating the validity of the goniometer in elbow measurements found a maximum standard error of the mean of 11.5° for total range of motion. Discussion Overall, the studies showed high intra- and interrater reliability of the universal goniometer. The reliability of the universal goniometer in non-expert examiners can be increased by clear instructions on goniometric alignment.</description><identifier>ISSN: 1758-5732</identifier><identifier>EISSN: 1758-5740</identifier><identifier>DOI: 10.1177/1758573218774326</identifier><identifier>PMID: 30214494</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Elbow</subject><ispartof>Shoulder &amp; Elbow, 2018-10, Vol.10 (4), p.274-284</ispartof><rights>2018 The British Elbow &amp; Shoulder Society</rights><rights>2018 The British Elbow &amp; Shoulder Society 2018 The British Elbow &amp; Shoulder Society</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3496-44adfb85a97732c2d52714591aaa4bbd8939a1bf17e3deaa0f8de3ded9edccd3</citedby><cites>FETCH-LOGICAL-c3496-44adfb85a97732c2d52714591aaa4bbd8939a1bf17e3deaa0f8de3ded9edccd3</cites><orcidid>0000-0003-4656-6053</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6134535/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6134535/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,313,314,727,780,784,792,885,21819,27922,27924,27925,43621,43622,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30214494$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>van Rijn, Suzanne F</creatorcontrib><creatorcontrib>Zwerus, Elisa L</creatorcontrib><creatorcontrib>Koenraadt, Koen LM</creatorcontrib><creatorcontrib>Jacobs, Wilco CH</creatorcontrib><creatorcontrib>van den Bekerom, Michel PJ</creatorcontrib><creatorcontrib>Eygendaal, Denise</creatorcontrib><title>The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature</title><title>Shoulder &amp; Elbow</title><addtitle>Shoulder Elbow</addtitle><description>Background The universal goniometer is a simple measuring tool. With this review we aimed to investigate the reliability and validity of the universal goniometer in measurements of the adults' elbow. Methods Preferred Reporting Items for Systematic reviews and Meta-Analysis guidelines were followed and our study protocol was published online at PROSPERO. A literature search was conducted on relevant studies. Methodological quality was assessed using the Quality Appraisal of Diagnostic Reliability (QAREL) scoring system. Results Out of 697 studies yielded from our literature search, 12 were included. Six studies were rated as high quality. The intrarater reliability intraclass correlation coefficient ranged from 0.45 to 0.99, the interrater reliability ranged from intraclass correlation coefficient 0.53–0.97. One study providing instructions on goniometric alignment did not find a difference in expert versus non-expert examiners. Another study in which examiners were not instructed found a higher interrater reliability in expert examiners. One study investigating the validity of the goniometer in elbow measurements found a maximum standard error of the mean of 11.5° for total range of motion. Discussion Overall, the studies showed high intra- and interrater reliability of the universal goniometer. The reliability of the universal goniometer in non-expert examiners can be increased by clear instructions on goniometric alignment.</description><subject>Elbow</subject><issn>1758-5732</issn><issn>1758-5740</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp1kc1v3CAQxVHVqPm891Rx7MUtGDB2D5WiqG0qRcpl72hsxhsibFLAG-1_H6xNV22lnhiGN7954hHynrNPnGv9mWvVKi1q3motRd28IWdrq1JasrfHWtSn5DylR8Ya3Wj1jpwKVnMpO3lGwuYBaUTvoHfe5T2F2dIdeGfXSxjpNswuTJijGyj6PjzTCSEtESecc6JupmAXn9MXek3TPmWcIBdpxJ3D5xWQy4JCxgi5TF2SkxF8wqvX84Jsvn_b3NxWd_c_ft5c31WDkF1TSQl27FsFnS72h9qqWnOpOg4Asu9t24kOeD9yjcIiABtbu1a2QzsMVlyQrwfs09JPpVW8RvDmKboJ4t4EcObvl9k9mG3YmYYLqYQqgI-vgBh-LZiymVwa0HuYMSzJ1JwpJjol2yJlB-kQQ0oRx-Mazswak_k3pjLy4U97x4HfuRRBdRAk2KJ5DEucy2_9H_gCHEWejA</recordid><startdate>20181001</startdate><enddate>20181001</enddate><creator>van Rijn, Suzanne F</creator><creator>Zwerus, Elisa L</creator><creator>Koenraadt, Koen LM</creator><creator>Jacobs, Wilco CH</creator><creator>van den Bekerom, Michel PJ</creator><creator>Eygendaal, Denise</creator><general>SAGE Publications</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0003-4656-6053</orcidid></search><sort><creationdate>20181001</creationdate><title>The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature</title><author>van Rijn, Suzanne F ; Zwerus, Elisa L ; Koenraadt, Koen LM ; Jacobs, Wilco CH ; van den Bekerom, Michel PJ ; Eygendaal, Denise</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3496-44adfb85a97732c2d52714591aaa4bbd8939a1bf17e3deaa0f8de3ded9edccd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Elbow</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>van Rijn, Suzanne F</creatorcontrib><creatorcontrib>Zwerus, Elisa L</creatorcontrib><creatorcontrib>Koenraadt, Koen LM</creatorcontrib><creatorcontrib>Jacobs, Wilco CH</creatorcontrib><creatorcontrib>van den Bekerom, Michel PJ</creatorcontrib><creatorcontrib>Eygendaal, Denise</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Shoulder &amp; Elbow</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>van Rijn, Suzanne F</au><au>Zwerus, Elisa L</au><au>Koenraadt, Koen LM</au><au>Jacobs, Wilco CH</au><au>van den Bekerom, Michel PJ</au><au>Eygendaal, Denise</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature</atitle><jtitle>Shoulder &amp; Elbow</jtitle><addtitle>Shoulder Elbow</addtitle><date>2018-10-01</date><risdate>2018</risdate><volume>10</volume><issue>4</issue><spage>274</spage><epage>284</epage><pages>274-284</pages><issn>1758-5732</issn><eissn>1758-5740</eissn><abstract>Background The universal goniometer is a simple measuring tool. With this review we aimed to investigate the reliability and validity of the universal goniometer in measurements of the adults' elbow. Methods Preferred Reporting Items for Systematic reviews and Meta-Analysis guidelines were followed and our study protocol was published online at PROSPERO. A literature search was conducted on relevant studies. Methodological quality was assessed using the Quality Appraisal of Diagnostic Reliability (QAREL) scoring system. Results Out of 697 studies yielded from our literature search, 12 were included. Six studies were rated as high quality. The intrarater reliability intraclass correlation coefficient ranged from 0.45 to 0.99, the interrater reliability ranged from intraclass correlation coefficient 0.53–0.97. One study providing instructions on goniometric alignment did not find a difference in expert versus non-expert examiners. Another study in which examiners were not instructed found a higher interrater reliability in expert examiners. One study investigating the validity of the goniometer in elbow measurements found a maximum standard error of the mean of 11.5° for total range of motion. Discussion Overall, the studies showed high intra- and interrater reliability of the universal goniometer. The reliability of the universal goniometer in non-expert examiners can be increased by clear instructions on goniometric alignment.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>30214494</pmid><doi>10.1177/1758573218774326</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0003-4656-6053</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1758-5732
ispartof Shoulder & Elbow, 2018-10, Vol.10 (4), p.274-284
issn 1758-5732
1758-5740
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6134535
source Access via SAGE; EZB-FREE-00999 freely available EZB journals; PubMed Central
subjects Elbow
title The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T09%3A57%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20reliability%20and%20validity%20of%20goniometric%20elbow%20measurements%20in%20adults:%20A%20systematic%20review%20of%20the%20literature&rft.jtitle=Shoulder%20&%20Elbow&rft.au=van%20Rijn,%20Suzanne%20F&rft.date=2018-10-01&rft.volume=10&rft.issue=4&rft.spage=274&rft.epage=284&rft.pages=274-284&rft.issn=1758-5732&rft.eissn=1758-5740&rft_id=info:doi/10.1177/1758573218774326&rft_dat=%3Cproquest_pubme%3E2105039548%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2105039548&rft_id=info:pmid/30214494&rft_sage_id=10.1177_1758573218774326&rfr_iscdi=true