Frequent Tail-tip Blood Sampling in Mice for the Assessment of Pulsatile Luteinizing Hormone Secretion

In many endocrine systems, circulating factors or hormones are not released continuously, but are secreted as a discrete pulse in response to a releasing factor. Single-point sampling measures are inadequate to fully understand the biological significance of the secretory pattern of pulsatile hormon...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Visualized Experiments 2018-07 (137)
Hauptverfasser: McCosh, Richard B., Kreisman, Michael J., Breen, Kellie M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 137
container_start_page
container_title Journal of Visualized Experiments
container_volume
creator McCosh, Richard B.
Kreisman, Michael J.
Breen, Kellie M.
description In many endocrine systems, circulating factors or hormones are not released continuously, but are secreted as a discrete pulse in response to a releasing factor. Single-point sampling measures are inadequate to fully understand the biological significance of the secretory pattern of pulsatile hormones either under normal physiologic conditions or during conditions of dysregulation. Luteinizing hormone (LH) is synthesized by the anterior pituitary gonadotrope cells and secreted in a pulsatile pattern which requires frequent collection of blood samples for pulse assessment. This has not been possible in mice until recently, due to the development of a high-sensitivity LH assay and advancement in a technique for frequent low-volume sample collection, initially described by Steyn and colleagues.1 Here we describe a protocol for the frequent peripheral blood sample collection from mice with sufficient handling acclimatization to detect pulsatile secretion of LH. The current protocol details an expanded acclimatization period that allows assessment of robust and continuous pulses of LH over multiple hours. In this protocol, the tip of the tail is clipped and blood is collected from the tail using a hand-held pipette. For assessment of pulsatile LH in gonadectomized mice, serial samples are collected every 5-6 min for 90-180 min. Importantly, the collection of blood and measurement of robust pulses of LH can be accomplished in awake, freely behaving mice, given adequate handling acclimatization and effort to minimize environmental stressors. Sufficient acclimatization can be achieved within 4-5 weeks prior to blood collection. This protocol highlights advances in the methodology to ensure collection of whole blood samples for assessment of pulsatile LH secretion patterns over multiple hours in the mouse, a powerful animal model for neuroendocrine research.
doi_str_mv 10.3791/57894
format Article
fullrecord <record><control><sourceid>proquest_223</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6102042</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2074122330</sourcerecordid><originalsourceid>FETCH-LOGICAL-c382t-2eda83b9b0e0aef302a897d4ceef406df53b20b51bce916af0ac73673d8d9c8f3</originalsourceid><addsrcrecordid>eNpVkctKBDEQRYMovn_AhWQjuGmtTvq5EVR8wYiCCu5COl3RDOlkTLoF_Xp7nFF0VQV17q2iLiG7KRzxsk6P87KqsxWymdYZJFCVz6t_-g2yFeMUoGCQV-tkgwPwvCyyTaIvA74N6Hr6KI1NejOjZ9b7lj7IbmaNe6HG0VujkGofaP-K9DRGjLGbS7ym94ONsjcW6WTo0TjzOddc-9B5h_QBVcDeeLdD1rS0EXeXdZs8XV48nl8nk7urm_PTSaJ4xfqEYSsr3tQNIEjUHJis6rLNFKLOoGh1zhsGTZ42Cuu0kBqkKnlR8rZqa1Vpvk1OFr6zoemwVeOVQVoxC6aT4UN4acT_iTOv4sW_iyIFBhkbDQ6XBsGPf4m96ExUaK106IcoGJRZyhjnMKIHC1QFH2NA_bsmBTHPRHxnMnL7f2_6pX5CGIG9BTD17yimfghu_NFS_QVYcpHS</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2074122330</pqid></control><display><type>article</type><title>Frequent Tail-tip Blood Sampling in Mice for the Assessment of Pulsatile Luteinizing Hormone Secretion</title><source>Journal of Visualized Experiments : JoVE Collection</source><creator>McCosh, Richard B. ; Kreisman, Michael J. ; Breen, Kellie M.</creator><creatorcontrib>McCosh, Richard B. ; Kreisman, Michael J. ; Breen, Kellie M.</creatorcontrib><description>In many endocrine systems, circulating factors or hormones are not released continuously, but are secreted as a discrete pulse in response to a releasing factor. Single-point sampling measures are inadequate to fully understand the biological significance of the secretory pattern of pulsatile hormones either under normal physiologic conditions or during conditions of dysregulation. Luteinizing hormone (LH) is synthesized by the anterior pituitary gonadotrope cells and secreted in a pulsatile pattern which requires frequent collection of blood samples for pulse assessment. This has not been possible in mice until recently, due to the development of a high-sensitivity LH assay and advancement in a technique for frequent low-volume sample collection, initially described by Steyn and colleagues.1 Here we describe a protocol for the frequent peripheral blood sample collection from mice with sufficient handling acclimatization to detect pulsatile secretion of LH. The current protocol details an expanded acclimatization period that allows assessment of robust and continuous pulses of LH over multiple hours. In this protocol, the tip of the tail is clipped and blood is collected from the tail using a hand-held pipette. For assessment of pulsatile LH in gonadectomized mice, serial samples are collected every 5-6 min for 90-180 min. Importantly, the collection of blood and measurement of robust pulses of LH can be accomplished in awake, freely behaving mice, given adequate handling acclimatization and effort to minimize environmental stressors. Sufficient acclimatization can be achieved within 4-5 weeks prior to blood collection. This protocol highlights advances in the methodology to ensure collection of whole blood samples for assessment of pulsatile LH secretion patterns over multiple hours in the mouse, a powerful animal model for neuroendocrine research.</description><identifier>ISSN: 1940-087X</identifier><identifier>EISSN: 1940-087X</identifier><identifier>DOI: 10.3791/57894</identifier><identifier>PMID: 30035764</identifier><language>eng</language><publisher>United States: MyJove Corporation</publisher><subject>Animals ; Blood Specimen Collection - methods ; Luteinizing Hormone - metabolism ; Mice ; Neuroscience ; Tail - blood supply</subject><ispartof>Journal of Visualized Experiments, 2018-07 (137)</ispartof><rights>Copyright © 2018, Journal of Visualized Experiments</rights><rights>Copyright © 2018, Journal of Visualized Experiments 2018</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c382t-2eda83b9b0e0aef302a897d4ceef406df53b20b51bce916af0ac73673d8d9c8f3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.jove.com/files/email_thumbs/57894.png</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6102042/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6102042/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,3843,27924,27925,53791,53793</link.rule.ids><linktorsrc>$$Uhttp://dx.doi.org/10.3791/57894$$EView_record_in_Journal_of_Visualized_Experiments$$FView_record_in_$$GJournal_of_Visualized_Experiments</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30035764$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>McCosh, Richard B.</creatorcontrib><creatorcontrib>Kreisman, Michael J.</creatorcontrib><creatorcontrib>Breen, Kellie M.</creatorcontrib><title>Frequent Tail-tip Blood Sampling in Mice for the Assessment of Pulsatile Luteinizing Hormone Secretion</title><title>Journal of Visualized Experiments</title><addtitle>J Vis Exp</addtitle><description>In many endocrine systems, circulating factors or hormones are not released continuously, but are secreted as a discrete pulse in response to a releasing factor. Single-point sampling measures are inadequate to fully understand the biological significance of the secretory pattern of pulsatile hormones either under normal physiologic conditions or during conditions of dysregulation. Luteinizing hormone (LH) is synthesized by the anterior pituitary gonadotrope cells and secreted in a pulsatile pattern which requires frequent collection of blood samples for pulse assessment. This has not been possible in mice until recently, due to the development of a high-sensitivity LH assay and advancement in a technique for frequent low-volume sample collection, initially described by Steyn and colleagues.1 Here we describe a protocol for the frequent peripheral blood sample collection from mice with sufficient handling acclimatization to detect pulsatile secretion of LH. The current protocol details an expanded acclimatization period that allows assessment of robust and continuous pulses of LH over multiple hours. In this protocol, the tip of the tail is clipped and blood is collected from the tail using a hand-held pipette. For assessment of pulsatile LH in gonadectomized mice, serial samples are collected every 5-6 min for 90-180 min. Importantly, the collection of blood and measurement of robust pulses of LH can be accomplished in awake, freely behaving mice, given adequate handling acclimatization and effort to minimize environmental stressors. Sufficient acclimatization can be achieved within 4-5 weeks prior to blood collection. This protocol highlights advances in the methodology to ensure collection of whole blood samples for assessment of pulsatile LH secretion patterns over multiple hours in the mouse, a powerful animal model for neuroendocrine research.</description><subject>Animals</subject><subject>Blood Specimen Collection - methods</subject><subject>Luteinizing Hormone - metabolism</subject><subject>Mice</subject><subject>Neuroscience</subject><subject>Tail - blood supply</subject><issn>1940-087X</issn><issn>1940-087X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVkctKBDEQRYMovn_AhWQjuGmtTvq5EVR8wYiCCu5COl3RDOlkTLoF_Xp7nFF0VQV17q2iLiG7KRzxsk6P87KqsxWymdYZJFCVz6t_-g2yFeMUoGCQV-tkgwPwvCyyTaIvA74N6Hr6KI1NejOjZ9b7lj7IbmaNe6HG0VujkGofaP-K9DRGjLGbS7ym94ONsjcW6WTo0TjzOddc-9B5h_QBVcDeeLdD1rS0EXeXdZs8XV48nl8nk7urm_PTSaJ4xfqEYSsr3tQNIEjUHJis6rLNFKLOoGh1zhsGTZ42Cuu0kBqkKnlR8rZqa1Vpvk1OFr6zoemwVeOVQVoxC6aT4UN4acT_iTOv4sW_iyIFBhkbDQ6XBsGPf4m96ExUaK106IcoGJRZyhjnMKIHC1QFH2NA_bsmBTHPRHxnMnL7f2_6pX5CGIG9BTD17yimfghu_NFS_QVYcpHS</recordid><startdate>20180704</startdate><enddate>20180704</enddate><creator>McCosh, Richard B.</creator><creator>Kreisman, Michael J.</creator><creator>Breen, Kellie M.</creator><general>MyJove Corporation</general><scope>BVVXV</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20180704</creationdate><title>Frequent Tail-tip Blood Sampling in Mice for the Assessment of Pulsatile Luteinizing Hormone Secretion</title><author>McCosh, Richard B. ; Kreisman, Michael J. ; Breen, Kellie M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c382t-2eda83b9b0e0aef302a897d4ceef406df53b20b51bce916af0ac73673d8d9c8f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Animals</topic><topic>Blood Specimen Collection - methods</topic><topic>Luteinizing Hormone - metabolism</topic><topic>Mice</topic><topic>Neuroscience</topic><topic>Tail - blood supply</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>McCosh, Richard B.</creatorcontrib><creatorcontrib>Kreisman, Michael J.</creatorcontrib><creatorcontrib>Breen, Kellie M.</creatorcontrib><collection>JoVE Journal: Neuroscience</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of Visualized Experiments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>McCosh, Richard B.</au><au>Kreisman, Michael J.</au><au>Breen, Kellie M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Frequent Tail-tip Blood Sampling in Mice for the Assessment of Pulsatile Luteinizing Hormone Secretion</atitle><jtitle>Journal of Visualized Experiments</jtitle><addtitle>J Vis Exp</addtitle><date>2018-07-04</date><risdate>2018</risdate><issue>137</issue><issn>1940-087X</issn><eissn>1940-087X</eissn><abstract>In many endocrine systems, circulating factors or hormones are not released continuously, but are secreted as a discrete pulse in response to a releasing factor. Single-point sampling measures are inadequate to fully understand the biological significance of the secretory pattern of pulsatile hormones either under normal physiologic conditions or during conditions of dysregulation. Luteinizing hormone (LH) is synthesized by the anterior pituitary gonadotrope cells and secreted in a pulsatile pattern which requires frequent collection of blood samples for pulse assessment. This has not been possible in mice until recently, due to the development of a high-sensitivity LH assay and advancement in a technique for frequent low-volume sample collection, initially described by Steyn and colleagues.1 Here we describe a protocol for the frequent peripheral blood sample collection from mice with sufficient handling acclimatization to detect pulsatile secretion of LH. The current protocol details an expanded acclimatization period that allows assessment of robust and continuous pulses of LH over multiple hours. In this protocol, the tip of the tail is clipped and blood is collected from the tail using a hand-held pipette. For assessment of pulsatile LH in gonadectomized mice, serial samples are collected every 5-6 min for 90-180 min. Importantly, the collection of blood and measurement of robust pulses of LH can be accomplished in awake, freely behaving mice, given adequate handling acclimatization and effort to minimize environmental stressors. Sufficient acclimatization can be achieved within 4-5 weeks prior to blood collection. This protocol highlights advances in the methodology to ensure collection of whole blood samples for assessment of pulsatile LH secretion patterns over multiple hours in the mouse, a powerful animal model for neuroendocrine research.</abstract><cop>United States</cop><pub>MyJove Corporation</pub><pmid>30035764</pmid><doi>10.3791/57894</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1940-087X
ispartof Journal of Visualized Experiments, 2018-07 (137)
issn 1940-087X
1940-087X
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6102042
source Journal of Visualized Experiments : JoVE Collection
subjects Animals
Blood Specimen Collection - methods
Luteinizing Hormone - metabolism
Mice
Neuroscience
Tail - blood supply
title Frequent Tail-tip Blood Sampling in Mice for the Assessment of Pulsatile Luteinizing Hormone Secretion
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T08%3A48%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_223&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Frequent%20Tail-tip%20Blood%20Sampling%20in%20Mice%20for%20the%20Assessment%20of%20Pulsatile%20Luteinizing%20Hormone%20Secretion&rft.jtitle=Journal%20of%20Visualized%20Experiments&rft.au=McCosh,%20Richard%20B.&rft.date=2018-07-04&rft.issue=137&rft.issn=1940-087X&rft.eissn=1940-087X&rft_id=info:doi/10.3791/57894&rft_dat=%3Cproquest_223%3E2074122330%3C/proquest_223%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2074122330&rft_id=info:pmid/30035764&rfr_iscdi=true