Diagnostic accuracy of 2-hydroxyglutarate magnetic resonance spectroscopy in newly diagnosed brain mass and suspected recurrent gliomas

Isocitrate dehydrogenase (IDH) mutations result in abnormal accumulation of 2-hydroxyglutarate (2HG) in gliomas that can be detected by MRS. We examined the diagnostic accuracy of 2HG single-voxel spectroscopy (SVS) and chemical shift imaging (CSI) in both newly diagnosed and posttreatment settings....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Neuro-oncology (Charlottesville, Va.) Va.), 2018-08, Vol.20 (9), p.1262-1271
Hauptverfasser: Zhou, Min, Zhou, Yue, Liao, Huijun, Rowland, Benjamin C, Kong, Xiangquan, Arvold, Nils D, Reardon, David A, Wen, Patrick Y, Lin, Alexander P, Huang, Raymond Y
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1271
container_issue 9
container_start_page 1262
container_title Neuro-oncology (Charlottesville, Va.)
container_volume 20
creator Zhou, Min
Zhou, Yue
Liao, Huijun
Rowland, Benjamin C
Kong, Xiangquan
Arvold, Nils D
Reardon, David A
Wen, Patrick Y
Lin, Alexander P
Huang, Raymond Y
description Isocitrate dehydrogenase (IDH) mutations result in abnormal accumulation of 2-hydroxyglutarate (2HG) in gliomas that can be detected by MRS. We examined the diagnostic accuracy of 2HG single-voxel spectroscopy (SVS) and chemical shift imaging (CSI) in both newly diagnosed and posttreatment settings. Long echo time (97 ms) SVS and CSI were acquired in 85 subjects, including a discovery cohort of 39 patients who had postoperative residual or recurrent glioma with confirmed IDH-mutation status and 6 normal volunteers, a prospective preoperative validation cohort of 24 patients with newly diagnosed brain mass, and a prospective recurrent-lesion validation cohort of 16 previously treated IDH-mutant glioma patients with suspected tumor recurrence. The optimal thresholds for both methods in diagnosing IDH status were determined by receiver operating characteristic analysis in the discovery cohort and then applied to the 2 validation cohorts to assess the diagnostic performance. The optimal 2HG/creatine thresholds of SVS and 75th percentile CSI for IDH mutations were 0.11 and 0.23, respectively. When applied to the validation sets, the sensitivity, specificity, and accuracy in distinguishing IDH-mutant gliomas in the preoperative cohort were 85.71%, 100.00%, and 94.12% for SVS, and 100.00%, 69.23%, and 81.82% for CSI, respectively. In the recurrent-lesion cohort, the sensitivity, specificity, and accuracy for discriminating IDH-positive recurrent gliomas were 40.00%, 62.50%, and 53.85% for SVS, and 66.67%, 100.00%, and 86.67% for CSI, respectively. 2HG MRS provides diagnostic utility for IDH-mutant gliomas both preoperatively and at time of suspected tumor recurrence. SVS has a better diagnostic performance for untreated IDH-mutant gliomas, whereas CSI demonstrates greater performance in identifying recurrent tumors.
doi_str_mv 10.1093/neuonc/noy022
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6071662</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2002213762</sourcerecordid><originalsourceid>FETCH-LOGICAL-c453t-936bed07a4692db830d81c62ce75a90a1ccc498101e245b415593bdbb86539cb3</originalsourceid><addsrcrecordid>eNpVkc1O3TAQha2qVaHQZbeVl92k-Cd2kk2ligJFQmJT1pY9nntJldi3dtI2T8BrY24AwWpGM9-cGc0h5BNnXznr5EnAOQY4CXFhQrwhh1wJWalW67f7XFSt4s0B-ZDzb8YEV5q_Jweiq2Wps0Ny96O32xDz1AO1AHOysNC4oaK6XXyK_5ftME822QnpWEB84BLmGGwApHmHMKWYIe4W2gca8N-wUL9Koqcu2VIdbc7UBk_zvB8ojYRlVcIw0e3QxwIck3cbO2T8-BiPyM352a_Tn9XV9cXl6ferCmolp6qT2qFnja11J7xrJfMtBy0AG2U7ZjkA1F3LGUdRK1dzpTrpvHOtVrIDJ4_It1V3N7sRPZQTkh3MLvWjTYuJtjevO6G_Ndv412jWcK1FEfjyKJDinxnzZMY-Aw6DDRjnbET5suCy2aPVikJ5UU64eV7DmXkwz6zmmdW8wn9-edsz_eSWvAcJwZzX</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2002213762</pqid></control><display><type>article</type><title>Diagnostic accuracy of 2-hydroxyglutarate magnetic resonance spectroscopy in newly diagnosed brain mass and suspected recurrent gliomas</title><source>Oxford University Press Journals All Titles (1996-Current)</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><creator>Zhou, Min ; Zhou, Yue ; Liao, Huijun ; Rowland, Benjamin C ; Kong, Xiangquan ; Arvold, Nils D ; Reardon, David A ; Wen, Patrick Y ; Lin, Alexander P ; Huang, Raymond Y</creator><creatorcontrib>Zhou, Min ; Zhou, Yue ; Liao, Huijun ; Rowland, Benjamin C ; Kong, Xiangquan ; Arvold, Nils D ; Reardon, David A ; Wen, Patrick Y ; Lin, Alexander P ; Huang, Raymond Y</creatorcontrib><description>Isocitrate dehydrogenase (IDH) mutations result in abnormal accumulation of 2-hydroxyglutarate (2HG) in gliomas that can be detected by MRS. We examined the diagnostic accuracy of 2HG single-voxel spectroscopy (SVS) and chemical shift imaging (CSI) in both newly diagnosed and posttreatment settings. Long echo time (97 ms) SVS and CSI were acquired in 85 subjects, including a discovery cohort of 39 patients who had postoperative residual or recurrent glioma with confirmed IDH-mutation status and 6 normal volunteers, a prospective preoperative validation cohort of 24 patients with newly diagnosed brain mass, and a prospective recurrent-lesion validation cohort of 16 previously treated IDH-mutant glioma patients with suspected tumor recurrence. The optimal thresholds for both methods in diagnosing IDH status were determined by receiver operating characteristic analysis in the discovery cohort and then applied to the 2 validation cohorts to assess the diagnostic performance. The optimal 2HG/creatine thresholds of SVS and 75th percentile CSI for IDH mutations were 0.11 and 0.23, respectively. When applied to the validation sets, the sensitivity, specificity, and accuracy in distinguishing IDH-mutant gliomas in the preoperative cohort were 85.71%, 100.00%, and 94.12% for SVS, and 100.00%, 69.23%, and 81.82% for CSI, respectively. In the recurrent-lesion cohort, the sensitivity, specificity, and accuracy for discriminating IDH-positive recurrent gliomas were 40.00%, 62.50%, and 53.85% for SVS, and 66.67%, 100.00%, and 86.67% for CSI, respectively. 2HG MRS provides diagnostic utility for IDH-mutant gliomas both preoperatively and at time of suspected tumor recurrence. SVS has a better diagnostic performance for untreated IDH-mutant gliomas, whereas CSI demonstrates greater performance in identifying recurrent tumors.</description><identifier>ISSN: 1522-8517</identifier><identifier>EISSN: 1523-5866</identifier><identifier>DOI: 10.1093/neuonc/noy022</identifier><identifier>PMID: 29438510</identifier><language>eng</language><publisher>England: Oxford University Press</publisher><subject>Editor's Choice ; Neuroimaging</subject><ispartof>Neuro-oncology (Charlottesville, Va.), 2018-08, Vol.20 (9), p.1262-1271</ispartof><rights>The Author(s) 2018. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com 2018</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c453t-936bed07a4692db830d81c62ce75a90a1ccc498101e245b415593bdbb86539cb3</citedby><cites>FETCH-LOGICAL-c453t-936bed07a4692db830d81c62ce75a90a1ccc498101e245b415593bdbb86539cb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6071662/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6071662/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,723,776,780,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29438510$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zhou, Min</creatorcontrib><creatorcontrib>Zhou, Yue</creatorcontrib><creatorcontrib>Liao, Huijun</creatorcontrib><creatorcontrib>Rowland, Benjamin C</creatorcontrib><creatorcontrib>Kong, Xiangquan</creatorcontrib><creatorcontrib>Arvold, Nils D</creatorcontrib><creatorcontrib>Reardon, David A</creatorcontrib><creatorcontrib>Wen, Patrick Y</creatorcontrib><creatorcontrib>Lin, Alexander P</creatorcontrib><creatorcontrib>Huang, Raymond Y</creatorcontrib><title>Diagnostic accuracy of 2-hydroxyglutarate magnetic resonance spectroscopy in newly diagnosed brain mass and suspected recurrent gliomas</title><title>Neuro-oncology (Charlottesville, Va.)</title><addtitle>Neuro Oncol</addtitle><description>Isocitrate dehydrogenase (IDH) mutations result in abnormal accumulation of 2-hydroxyglutarate (2HG) in gliomas that can be detected by MRS. We examined the diagnostic accuracy of 2HG single-voxel spectroscopy (SVS) and chemical shift imaging (CSI) in both newly diagnosed and posttreatment settings. Long echo time (97 ms) SVS and CSI were acquired in 85 subjects, including a discovery cohort of 39 patients who had postoperative residual or recurrent glioma with confirmed IDH-mutation status and 6 normal volunteers, a prospective preoperative validation cohort of 24 patients with newly diagnosed brain mass, and a prospective recurrent-lesion validation cohort of 16 previously treated IDH-mutant glioma patients with suspected tumor recurrence. The optimal thresholds for both methods in diagnosing IDH status were determined by receiver operating characteristic analysis in the discovery cohort and then applied to the 2 validation cohorts to assess the diagnostic performance. The optimal 2HG/creatine thresholds of SVS and 75th percentile CSI for IDH mutations were 0.11 and 0.23, respectively. When applied to the validation sets, the sensitivity, specificity, and accuracy in distinguishing IDH-mutant gliomas in the preoperative cohort were 85.71%, 100.00%, and 94.12% for SVS, and 100.00%, 69.23%, and 81.82% for CSI, respectively. In the recurrent-lesion cohort, the sensitivity, specificity, and accuracy for discriminating IDH-positive recurrent gliomas were 40.00%, 62.50%, and 53.85% for SVS, and 66.67%, 100.00%, and 86.67% for CSI, respectively. 2HG MRS provides diagnostic utility for IDH-mutant gliomas both preoperatively and at time of suspected tumor recurrence. SVS has a better diagnostic performance for untreated IDH-mutant gliomas, whereas CSI demonstrates greater performance in identifying recurrent tumors.</description><subject>Editor's Choice</subject><subject>Neuroimaging</subject><issn>1522-8517</issn><issn>1523-5866</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNpVkc1O3TAQha2qVaHQZbeVl92k-Cd2kk2ligJFQmJT1pY9nntJldi3dtI2T8BrY24AwWpGM9-cGc0h5BNnXznr5EnAOQY4CXFhQrwhh1wJWalW67f7XFSt4s0B-ZDzb8YEV5q_Jweiq2Wps0Ny96O32xDz1AO1AHOysNC4oaK6XXyK_5ftME822QnpWEB84BLmGGwApHmHMKWYIe4W2gca8N-wUL9Koqcu2VIdbc7UBk_zvB8ojYRlVcIw0e3QxwIck3cbO2T8-BiPyM352a_Tn9XV9cXl6ferCmolp6qT2qFnja11J7xrJfMtBy0AG2U7ZjkA1F3LGUdRK1dzpTrpvHOtVrIDJ4_It1V3N7sRPZQTkh3MLvWjTYuJtjevO6G_Ndv412jWcK1FEfjyKJDinxnzZMY-Aw6DDRjnbET5suCy2aPVikJ5UU64eV7DmXkwz6zmmdW8wn9-edsz_eSWvAcJwZzX</recordid><startdate>20180802</startdate><enddate>20180802</enddate><creator>Zhou, Min</creator><creator>Zhou, Yue</creator><creator>Liao, Huijun</creator><creator>Rowland, Benjamin C</creator><creator>Kong, Xiangquan</creator><creator>Arvold, Nils D</creator><creator>Reardon, David A</creator><creator>Wen, Patrick Y</creator><creator>Lin, Alexander P</creator><creator>Huang, Raymond Y</creator><general>Oxford University Press</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20180802</creationdate><title>Diagnostic accuracy of 2-hydroxyglutarate magnetic resonance spectroscopy in newly diagnosed brain mass and suspected recurrent gliomas</title><author>Zhou, Min ; Zhou, Yue ; Liao, Huijun ; Rowland, Benjamin C ; Kong, Xiangquan ; Arvold, Nils D ; Reardon, David A ; Wen, Patrick Y ; Lin, Alexander P ; Huang, Raymond Y</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c453t-936bed07a4692db830d81c62ce75a90a1ccc498101e245b415593bdbb86539cb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Editor's Choice</topic><topic>Neuroimaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhou, Min</creatorcontrib><creatorcontrib>Zhou, Yue</creatorcontrib><creatorcontrib>Liao, Huijun</creatorcontrib><creatorcontrib>Rowland, Benjamin C</creatorcontrib><creatorcontrib>Kong, Xiangquan</creatorcontrib><creatorcontrib>Arvold, Nils D</creatorcontrib><creatorcontrib>Reardon, David A</creatorcontrib><creatorcontrib>Wen, Patrick Y</creatorcontrib><creatorcontrib>Lin, Alexander P</creatorcontrib><creatorcontrib>Huang, Raymond Y</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Neuro-oncology (Charlottesville, Va.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhou, Min</au><au>Zhou, Yue</au><au>Liao, Huijun</au><au>Rowland, Benjamin C</au><au>Kong, Xiangquan</au><au>Arvold, Nils D</au><au>Reardon, David A</au><au>Wen, Patrick Y</au><au>Lin, Alexander P</au><au>Huang, Raymond Y</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Diagnostic accuracy of 2-hydroxyglutarate magnetic resonance spectroscopy in newly diagnosed brain mass and suspected recurrent gliomas</atitle><jtitle>Neuro-oncology (Charlottesville, Va.)</jtitle><addtitle>Neuro Oncol</addtitle><date>2018-08-02</date><risdate>2018</risdate><volume>20</volume><issue>9</issue><spage>1262</spage><epage>1271</epage><pages>1262-1271</pages><issn>1522-8517</issn><eissn>1523-5866</eissn><abstract>Isocitrate dehydrogenase (IDH) mutations result in abnormal accumulation of 2-hydroxyglutarate (2HG) in gliomas that can be detected by MRS. We examined the diagnostic accuracy of 2HG single-voxel spectroscopy (SVS) and chemical shift imaging (CSI) in both newly diagnosed and posttreatment settings. Long echo time (97 ms) SVS and CSI were acquired in 85 subjects, including a discovery cohort of 39 patients who had postoperative residual or recurrent glioma with confirmed IDH-mutation status and 6 normal volunteers, a prospective preoperative validation cohort of 24 patients with newly diagnosed brain mass, and a prospective recurrent-lesion validation cohort of 16 previously treated IDH-mutant glioma patients with suspected tumor recurrence. The optimal thresholds for both methods in diagnosing IDH status were determined by receiver operating characteristic analysis in the discovery cohort and then applied to the 2 validation cohorts to assess the diagnostic performance. The optimal 2HG/creatine thresholds of SVS and 75th percentile CSI for IDH mutations were 0.11 and 0.23, respectively. When applied to the validation sets, the sensitivity, specificity, and accuracy in distinguishing IDH-mutant gliomas in the preoperative cohort were 85.71%, 100.00%, and 94.12% for SVS, and 100.00%, 69.23%, and 81.82% for CSI, respectively. In the recurrent-lesion cohort, the sensitivity, specificity, and accuracy for discriminating IDH-positive recurrent gliomas were 40.00%, 62.50%, and 53.85% for SVS, and 66.67%, 100.00%, and 86.67% for CSI, respectively. 2HG MRS provides diagnostic utility for IDH-mutant gliomas both preoperatively and at time of suspected tumor recurrence. SVS has a better diagnostic performance for untreated IDH-mutant gliomas, whereas CSI demonstrates greater performance in identifying recurrent tumors.</abstract><cop>England</cop><pub>Oxford University Press</pub><pmid>29438510</pmid><doi>10.1093/neuonc/noy022</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1522-8517
ispartof Neuro-oncology (Charlottesville, Va.), 2018-08, Vol.20 (9), p.1262-1271
issn 1522-8517
1523-5866
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6071662
source Oxford University Press Journals All Titles (1996-Current); Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central
subjects Editor's Choice
Neuroimaging
title Diagnostic accuracy of 2-hydroxyglutarate magnetic resonance spectroscopy in newly diagnosed brain mass and suspected recurrent gliomas
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T17%3A22%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Diagnostic%20accuracy%20of%202-hydroxyglutarate%20magnetic%20resonance%20spectroscopy%20in%20newly%20diagnosed%20brain%20mass%20and%20suspected%20recurrent%20gliomas&rft.jtitle=Neuro-oncology%20(Charlottesville,%20Va.)&rft.au=Zhou,%20Min&rft.date=2018-08-02&rft.volume=20&rft.issue=9&rft.spage=1262&rft.epage=1271&rft.pages=1262-1271&rft.issn=1522-8517&rft.eissn=1523-5866&rft_id=info:doi/10.1093/neuonc/noy022&rft_dat=%3Cproquest_pubme%3E2002213762%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2002213762&rft_id=info:pmid/29438510&rfr_iscdi=true