High-resolution μCT of a mouse embryo using a compact laser-driven X-ray betatron source

In the field of X-ray microcomputed tomography (μCT) there is a growing need to reduce acquisition times at high spatial resolution (approximate micrometers) to facilitate in vivo and high-throughput operations. The state of the art represented by synchrotron light sources is not practical for certa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Proceedings of the National Academy of Sciences - PNAS 2018-06, Vol.115 (25), p.6335-6340
Hauptverfasser: Cole, Jason M., Symes, Daniel R., Lopes, Nelson C., Wood, Jonathan C., Poder, Kristjan, Alatabi, Saleh, Botchway, Stanley W., Foster, Peta S., Gratton, Sarah, Johnson, Sara, Kamperidis, Christos, Kononenko, Olena, De Lazzari, Michael, Palmer, Charlotte A. J., Rusby, Dean, Sanderson, Jeremy, Sandholzer, Michael, Sarri, Gianluca, Szoke-Kovacs, Zsombor, Teboul, Lydia, Thompson, James M., Warwick, Jonathan R., Westerberg, Henrik, Hill, Mark A., Norris, Dominic P., Mangles, Stuart P. D., Najmudin, Zulfikar
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In the field of X-ray microcomputed tomography (μCT) there is a growing need to reduce acquisition times at high spatial resolution (approximate micrometers) to facilitate in vivo and high-throughput operations. The state of the art represented by synchrotron light sources is not practical for certain applications, and therefore the development of high-brightness laboratory-scale sources is crucial. We present here imaging of a fixed embryonic mouse sample using a compact laser–plasma-based X-ray light source and compare the results to images obtained using a commercial X-ray μCT scanner. The radiation is generated by the betatron motion of electrons inside a dilute and transient plasma, which circumvents the flux limitations imposed by the solid or liquid anodes used in conventional electron-impact X-ray tubes. This X-ray source is pulsed (duration 1010 photons per pulse), small (diameter 15 keV. Stable X-ray performance enabled tomographic imaging of equivalent quality to that of the μCT scanner, an important confirmation of the suitability of the laser-driven source for applications. The X-ray flux achievable with this approach scales with the laser repetition rate without compromising the source size, which will allow the recording of high-resolution μCT scans in minutes.
ISSN:0027-8424
1091-6490
DOI:10.1073/pnas.1802314115