Diagnosis of vertebral deformities on chest CT and DXA compared to routine lateral thoracic spine X-ray

Summary X-ray, CT and DXA enable diagnosis of vertebral deformities. For this study, level of agreement of vertebral deformity diagnosis was analysed. We showed that especially on subject level, these imaging techniques could be used for opportunistic screening of vertebral deformities in COPD patie...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Osteoporosis international 2018-06, Vol.29 (6), p.1285-1293
Hauptverfasser: van Dort, M. J., Romme, E. A. P. M., Smeenk, F. W. J. M., Geusens, P. P. P. M., Wouters, E. F. M., van den Bergh, J. P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Summary X-ray, CT and DXA enable diagnosis of vertebral deformities. For this study, level of agreement of vertebral deformity diagnosis was analysed. We showed that especially on subject level, these imaging techniques could be used for opportunistic screening of vertebral deformities in COPD patients. Introduction X-ray and CT are frequently used for pulmonary evaluation in patients with chronic obstructive pulmonary disease (COPD) and also enable to diagnose vertebral deformities together with dual-energy X-ray absorptiometry (DXA) imaging. The aim of this research was to study the level of agreement of these imaging modalities for diagnosis of vertebral deformities from T4 to L1. Methods Eighty-seven subjects (mean age of 65; 50 males; 57 COPD patients) who had X-ray, chest CT (CCT) and DXA were included. Evaluable vertebrae were scored twice using SpineAnalyzer™ software. ICCs and kappas were calculated to examine intra-observer variability. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and area under the receiver operating characteristic curve (AUROC) were calculated to compare vertebral deformities diagnosed on the different imaging modalities. Results ICCs for height measurements were excellent (> 0.94). Kappas were good to excellent (0.64–0.77). At vertebral level, the AUROC was 0.85 for CCT vs. X-ray, 0.74 for DXA vs. X-ray and 0.77 for DXA vs. CCT. Sensitivity (51%–73%) and PPV (57%–70%) were fair to good; specificity and NPV were excellent (≥ 96%). At subject level, the AUROC values were comparable. Conclusions Reproducibility of height measurements of vertebrae is excellent with all three imaging modalities. On subject level, diagnostic performance of CT (PPV 79–82%; NPV 90–93%), and to a slightly lesser extend of DXA (PPV 73–77%; NPV 80–89%), indicates that these imaging techniques could be used for opportunistic screening of vertebral deformities in COPD patients.
ISSN:0937-941X
1433-2965