Reliability, validity and description of timed performance of the Jebsen–Taylor Test in patients with muscular dystrophies

•Jebsen–Taylor Test is reliable for evaluating people with Muscular Dystrophy.•Jebsen–Taylor Test is valid for assessing people with Muscular Dystrophy.•The internal consistency of the Jebsen–Taylor Test was found to be high. The Jebsen–Taylor Test evaluates upper limb function by measuring timed pe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Revista brasileira de fisioterapia (São Carlos (São Paulo, Brazil)) Brazil)), 2018-05, Vol.22 (3), p.190-197
Hauptverfasser: Artilheiro, Mariana Cunha, Fávero, Francis Meire, Caromano, Fátima Aparecida, Oliveira, Acary de Souza Bulle, Carvas, Nelson, Voos, Mariana Callil, Sá, Cristina dos Santos Cardoso de
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Jebsen–Taylor Test is reliable for evaluating people with Muscular Dystrophy.•Jebsen–Taylor Test is valid for assessing people with Muscular Dystrophy.•The internal consistency of the Jebsen–Taylor Test was found to be high. The Jebsen–Taylor Test evaluates upper limb function by measuring timed performance on everyday activities. The test is used to assess and monitor the progression of patients with Parkinson disease, cerebral palsy, stroke and brain injury. To analyze the reliability, internal consistency and validity of the Jebsen–Taylor Test in people with Muscular Dystrophy and to describe and classify upper limb timed performance of people with Muscular Dystrophy. Fifty patients with Muscular Dystrophy were assessed. Non-dominant and dominant upper limb performances on the Jebsen–Taylor Test were filmed. Two raters evaluated timed performance for inter-rater reliability analysis. Test–retest reliability was investigated by using intraclass correlation coefficients. Internal consistency was assessed using the Cronbach alpha. Construct validity was conducted by comparing the Jebsen–Taylor Test with the Performance of Upper Limb. The internal consistency of Jebsen–Taylor Test was good (Cronbach's α=0.98). A very high inter-rater reliability (0.903–0.999), except for writing with an Intraclass correlation coefficient of 0.772–1.000. Strong correlations between the Jebsen–Taylor Test and the Performance of Upper Limb Module were found (rho=−0.712). The Jebsen–Taylor Test is a reliable and valid measure of timed performance for people with Muscular Dystrophy.
ISSN:1413-3555
1809-9246
DOI:10.1016/j.bjpt.2017.09.010