A Three-Step Resolution-Reconfigurable Hazardous Multi-Gas Sensor Interface for Wireless Air-Quality Monitoring Applications
This paper presents a resolution-reconfigurable wide-range resistive sensor readout interface for wireless multi-gas monitoring applications that displays results on a smartphone. Three types of sensing resolutions were selected to minimize processing power consumption, and a dual-mode front-end str...
Gespeichert in:
Veröffentlicht in: | Sensors (Basel, Switzerland) Switzerland), 2018-03, Vol.18 (3), p.761 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 3 |
container_start_page | 761 |
container_title | Sensors (Basel, Switzerland) |
container_volume | 18 |
creator | Choi, Subin Park, Kyeonghwan Lee, Seungwook Lim, Yeongjin Oh, Byungjoo Chae, Hee Young Park, Chan Sam Shin, Heugjoo Kim, Jae Joon |
description | This paper presents a resolution-reconfigurable wide-range resistive sensor readout interface for wireless multi-gas monitoring applications that displays results on a smartphone. Three types of sensing resolutions were selected to minimize processing power consumption, and a dual-mode front-end structure was proposed to support the detection of a variety of hazardous gases with wide range of characteristic resistance. The readout integrated circuit (ROIC) was fabricated in a 0.18 μm CMOS process to provide three reconfigurable data conversions that correspond to a low-power resistance-to-digital converter (RDC), a 12-bit successive approximation register (SAR) analog-to-digital converter (ADC), and a 16-bit delta-sigma modulator. For functional feasibility, a wireless sensor system prototype that included in-house microelectromechanical (MEMS) sensing devices and commercial device products was manufactured and experimentally verified to detect a variety of hazardous gases. |
doi_str_mv | 10.3390/s18030761 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5876904</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2026507466</sourcerecordid><originalsourceid>FETCH-LOGICAL-c403t-e9196aa519586fb96c3827c1dcddd6a2d0d90c2beebdfe7c86e1dfcb07f8d7383</originalsourceid><addsrcrecordid>eNpdkVtrFTEQx4NYbG198AtIwBf7sDWXPdnkRTgUe4EWsRd8DNlkcpqSk2yTXaHih3cPrYfq08wwP_5z-SP0npIjzhX5XKkknHSCvkJ7tGVtIxkjr1_ku-htrfeEMM65fIN2mWqVFFLsod9LfHNXAJrrEQZ8BTXHaQw5NVdgc_JhNRXTR8Bn5pcpLk8VX05xDM2pqfgaUs0Fn6cRijcWsJ-rH6FAhFrxMpTm-2RiGB_xZU5hzCWkFV4OQwzWbGbUA7TjTazw7jnuo9uTrzfHZ83Ft9Pz4-VFY1vCxwYUVcKYBVULKXyvhOWSdZY665wThjniFLGsB-idh85KAdR525POS9dxyffRlyfdYerX4CyksZiohxLWpjzqbIL-t5PCnV7ln3ohO6FIOwt8ehYo-WGCOup1qBZiNAnmn2hGKOHzpE7M6Mf_0Ps8lTSfN1NMLEjXig11-ETZkmst4LfLUKI3nuqtpzP74eX2W_KvifwPep2ffA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2026507466</pqid></control><display><type>article</type><title>A Three-Step Resolution-Reconfigurable Hazardous Multi-Gas Sensor Interface for Wireless Air-Quality Monitoring Applications</title><source>MDPI - Multidisciplinary Digital Publishing Institute</source><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Free Full-Text Journals in Chemistry</source><creator>Choi, Subin ; Park, Kyeonghwan ; Lee, Seungwook ; Lim, Yeongjin ; Oh, Byungjoo ; Chae, Hee Young ; Park, Chan Sam ; Shin, Heugjoo ; Kim, Jae Joon</creator><creatorcontrib>Choi, Subin ; Park, Kyeonghwan ; Lee, Seungwook ; Lim, Yeongjin ; Oh, Byungjoo ; Chae, Hee Young ; Park, Chan Sam ; Shin, Heugjoo ; Kim, Jae Joon</creatorcontrib><description>This paper presents a resolution-reconfigurable wide-range resistive sensor readout interface for wireless multi-gas monitoring applications that displays results on a smartphone. Three types of sensing resolutions were selected to minimize processing power consumption, and a dual-mode front-end structure was proposed to support the detection of a variety of hazardous gases with wide range of characteristic resistance. The readout integrated circuit (ROIC) was fabricated in a 0.18 μm CMOS process to provide three reconfigurable data conversions that correspond to a low-power resistance-to-digital converter (RDC), a 12-bit successive approximation register (SAR) analog-to-digital converter (ADC), and a 16-bit delta-sigma modulator. For functional feasibility, a wireless sensor system prototype that included in-house microelectromechanical (MEMS) sensing devices and commercial device products was manufactured and experimentally verified to detect a variety of hazardous gases.</description><identifier>ISSN: 1424-8220</identifier><identifier>EISSN: 1424-8220</identifier><identifier>DOI: 10.3390/s18030761</identifier><identifier>PMID: 29498686</identifier><language>eng</language><publisher>Switzerland: MDPI AG</publisher><subject>Air monitoring ; Analog to digital conversion ; Analog to digital converters ; CMOS ; Gas sensors ; Integrated circuits ; Microelectromechanical systems ; Sensors ; Smartphones</subject><ispartof>Sensors (Basel, Switzerland), 2018-03, Vol.18 (3), p.761</ispartof><rights>Copyright MDPI AG 2018</rights><rights>2018 by the authors. 2018</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c403t-e9196aa519586fb96c3827c1dcddd6a2d0d90c2beebdfe7c86e1dfcb07f8d7383</citedby><cites>FETCH-LOGICAL-c403t-e9196aa519586fb96c3827c1dcddd6a2d0d90c2beebdfe7c86e1dfcb07f8d7383</cites><orcidid>0000-0002-8191-2436 ; 0000-0003-4581-4115 ; 0000-0002-2961-030X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5876904/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5876904/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,860,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29498686$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Choi, Subin</creatorcontrib><creatorcontrib>Park, Kyeonghwan</creatorcontrib><creatorcontrib>Lee, Seungwook</creatorcontrib><creatorcontrib>Lim, Yeongjin</creatorcontrib><creatorcontrib>Oh, Byungjoo</creatorcontrib><creatorcontrib>Chae, Hee Young</creatorcontrib><creatorcontrib>Park, Chan Sam</creatorcontrib><creatorcontrib>Shin, Heugjoo</creatorcontrib><creatorcontrib>Kim, Jae Joon</creatorcontrib><title>A Three-Step Resolution-Reconfigurable Hazardous Multi-Gas Sensor Interface for Wireless Air-Quality Monitoring Applications</title><title>Sensors (Basel, Switzerland)</title><addtitle>Sensors (Basel)</addtitle><description>This paper presents a resolution-reconfigurable wide-range resistive sensor readout interface for wireless multi-gas monitoring applications that displays results on a smartphone. Three types of sensing resolutions were selected to minimize processing power consumption, and a dual-mode front-end structure was proposed to support the detection of a variety of hazardous gases with wide range of characteristic resistance. The readout integrated circuit (ROIC) was fabricated in a 0.18 μm CMOS process to provide three reconfigurable data conversions that correspond to a low-power resistance-to-digital converter (RDC), a 12-bit successive approximation register (SAR) analog-to-digital converter (ADC), and a 16-bit delta-sigma modulator. For functional feasibility, a wireless sensor system prototype that included in-house microelectromechanical (MEMS) sensing devices and commercial device products was manufactured and experimentally verified to detect a variety of hazardous gases.</description><subject>Air monitoring</subject><subject>Analog to digital conversion</subject><subject>Analog to digital converters</subject><subject>CMOS</subject><subject>Gas sensors</subject><subject>Integrated circuits</subject><subject>Microelectromechanical systems</subject><subject>Sensors</subject><subject>Smartphones</subject><issn>1424-8220</issn><issn>1424-8220</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNpdkVtrFTEQx4NYbG198AtIwBf7sDWXPdnkRTgUe4EWsRd8DNlkcpqSk2yTXaHih3cPrYfq08wwP_5z-SP0npIjzhX5XKkknHSCvkJ7tGVtIxkjr1_ku-htrfeEMM65fIN2mWqVFFLsod9LfHNXAJrrEQZ8BTXHaQw5NVdgc_JhNRXTR8Bn5pcpLk8VX05xDM2pqfgaUs0Fn6cRijcWsJ-rH6FAhFrxMpTm-2RiGB_xZU5hzCWkFV4OQwzWbGbUA7TjTazw7jnuo9uTrzfHZ83Ft9Pz4-VFY1vCxwYUVcKYBVULKXyvhOWSdZY665wThjniFLGsB-idh85KAdR525POS9dxyffRlyfdYerX4CyksZiohxLWpjzqbIL-t5PCnV7ln3ohO6FIOwt8ehYo-WGCOup1qBZiNAnmn2hGKOHzpE7M6Mf_0Ps8lTSfN1NMLEjXig11-ETZkmst4LfLUKI3nuqtpzP74eX2W_KvifwPep2ffA</recordid><startdate>20180302</startdate><enddate>20180302</enddate><creator>Choi, Subin</creator><creator>Park, Kyeonghwan</creator><creator>Lee, Seungwook</creator><creator>Lim, Yeongjin</creator><creator>Oh, Byungjoo</creator><creator>Chae, Hee Young</creator><creator>Park, Chan Sam</creator><creator>Shin, Heugjoo</creator><creator>Kim, Jae Joon</creator><general>MDPI AG</general><general>MDPI</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-8191-2436</orcidid><orcidid>https://orcid.org/0000-0003-4581-4115</orcidid><orcidid>https://orcid.org/0000-0002-2961-030X</orcidid></search><sort><creationdate>20180302</creationdate><title>A Three-Step Resolution-Reconfigurable Hazardous Multi-Gas Sensor Interface for Wireless Air-Quality Monitoring Applications</title><author>Choi, Subin ; Park, Kyeonghwan ; Lee, Seungwook ; Lim, Yeongjin ; Oh, Byungjoo ; Chae, Hee Young ; Park, Chan Sam ; Shin, Heugjoo ; Kim, Jae Joon</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c403t-e9196aa519586fb96c3827c1dcddd6a2d0d90c2beebdfe7c86e1dfcb07f8d7383</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Air monitoring</topic><topic>Analog to digital conversion</topic><topic>Analog to digital converters</topic><topic>CMOS</topic><topic>Gas sensors</topic><topic>Integrated circuits</topic><topic>Microelectromechanical systems</topic><topic>Sensors</topic><topic>Smartphones</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Choi, Subin</creatorcontrib><creatorcontrib>Park, Kyeonghwan</creatorcontrib><creatorcontrib>Lee, Seungwook</creatorcontrib><creatorcontrib>Lim, Yeongjin</creatorcontrib><creatorcontrib>Oh, Byungjoo</creatorcontrib><creatorcontrib>Chae, Hee Young</creatorcontrib><creatorcontrib>Park, Chan Sam</creatorcontrib><creatorcontrib>Shin, Heugjoo</creatorcontrib><creatorcontrib>Kim, Jae Joon</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Sensors (Basel, Switzerland)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Choi, Subin</au><au>Park, Kyeonghwan</au><au>Lee, Seungwook</au><au>Lim, Yeongjin</au><au>Oh, Byungjoo</au><au>Chae, Hee Young</au><au>Park, Chan Sam</au><au>Shin, Heugjoo</au><au>Kim, Jae Joon</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Three-Step Resolution-Reconfigurable Hazardous Multi-Gas Sensor Interface for Wireless Air-Quality Monitoring Applications</atitle><jtitle>Sensors (Basel, Switzerland)</jtitle><addtitle>Sensors (Basel)</addtitle><date>2018-03-02</date><risdate>2018</risdate><volume>18</volume><issue>3</issue><spage>761</spage><pages>761-</pages><issn>1424-8220</issn><eissn>1424-8220</eissn><abstract>This paper presents a resolution-reconfigurable wide-range resistive sensor readout interface for wireless multi-gas monitoring applications that displays results on a smartphone. Three types of sensing resolutions were selected to minimize processing power consumption, and a dual-mode front-end structure was proposed to support the detection of a variety of hazardous gases with wide range of characteristic resistance. The readout integrated circuit (ROIC) was fabricated in a 0.18 μm CMOS process to provide three reconfigurable data conversions that correspond to a low-power resistance-to-digital converter (RDC), a 12-bit successive approximation register (SAR) analog-to-digital converter (ADC), and a 16-bit delta-sigma modulator. For functional feasibility, a wireless sensor system prototype that included in-house microelectromechanical (MEMS) sensing devices and commercial device products was manufactured and experimentally verified to detect a variety of hazardous gases.</abstract><cop>Switzerland</cop><pub>MDPI AG</pub><pmid>29498686</pmid><doi>10.3390/s18030761</doi><orcidid>https://orcid.org/0000-0002-8191-2436</orcidid><orcidid>https://orcid.org/0000-0003-4581-4115</orcidid><orcidid>https://orcid.org/0000-0002-2961-030X</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1424-8220 |
ispartof | Sensors (Basel, Switzerland), 2018-03, Vol.18 (3), p.761 |
issn | 1424-8220 1424-8220 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5876904 |
source | MDPI - Multidisciplinary Digital Publishing Institute; DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals; PubMed Central; Free Full-Text Journals in Chemistry |
subjects | Air monitoring Analog to digital conversion Analog to digital converters CMOS Gas sensors Integrated circuits Microelectromechanical systems Sensors Smartphones |
title | A Three-Step Resolution-Reconfigurable Hazardous Multi-Gas Sensor Interface for Wireless Air-Quality Monitoring Applications |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T15%3A29%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Three-Step%20Resolution-Reconfigurable%20Hazardous%20Multi-Gas%20Sensor%20Interface%20for%20Wireless%20Air-Quality%20Monitoring%20Applications&rft.jtitle=Sensors%20(Basel,%20Switzerland)&rft.au=Choi,%20Subin&rft.date=2018-03-02&rft.volume=18&rft.issue=3&rft.spage=761&rft.pages=761-&rft.issn=1424-8220&rft.eissn=1424-8220&rft_id=info:doi/10.3390/s18030761&rft_dat=%3Cproquest_pubme%3E2026507466%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2026507466&rft_id=info:pmid/29498686&rfr_iscdi=true |