Anatomically Realistic Simulations of Liver Ablation by Irreversible Electroporation: Impact of Blood Vessels on Ablation Volumes and Undertreatment
Irreversible electroporation is a novel tissue ablation technique which entails delivering intense electrical pulses to target tissue, hence producing fatal defects in the cell membrane. The present study numerically analyzes the potential impact of liver blood vessels on ablation by irreversible el...
Gespeichert in:
Veröffentlicht in: | Technology in cancer research & treatment 2017-12, Vol.16 (6), p.783-792 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 792 |
---|---|
container_issue | 6 |
container_start_page | 783 |
container_title | Technology in cancer research & treatment |
container_volume | 16 |
creator | Qasrawi, Radwan Silve, Louis Burdío, Fernando Abdeen, Ziad Ivorra, Antoni |
description | Irreversible electroporation is a novel tissue ablation technique which entails delivering intense electrical pulses to target tissue, hence producing fatal defects in the cell membrane. The present study numerically analyzes the potential impact of liver blood vessels on ablation by irreversible electroporation because of their influence on the electric field distribution. An anatomically realistic computer model of the liver and its vasculature within an abdominal section was employed, and blood vessels down to 0.4 mm in diameter were considered. In this model, the electric field distribution was simulated in a large series of scenarios (N = 576) corresponding to plausible percutaneous irreversible electroporation treatments by needle electrode pairs. These modeled treatments were relatively superficial (maximum penetration depth of the electrode within the liver = 26 mm) and it was ensured that the electrodes did not penetrate the vessels nor were in contact with them. In terms of total ablation volume, the maximum deviation caused by the presence of the vessels was 6%, which could be considered negligible compared to the impact by other sources of uncertainty. Sublethal field magnitudes were noticed around vessels covering volumes of up to 228 mm3. If in this model the blood was substituted by a liquid with a low electrical conductivity (0.1 S/m), the maximum volume covered by sublethal field magnitudes was 3.7 mm3 and almost no sublethal regions were observable. We conclude that undertreatment around blood vessels may occur in current liver ablation procedures by irreversible electroporation. Infusion of isotonic low conductivity liquids into the liver vasculature could prevent this risk. |
doi_str_mv | 10.1177/1533034616687477 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5762033</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1533034616687477</sage_id><sourcerecordid>1861544571</sourcerecordid><originalsourceid>FETCH-LOGICAL-c476t-7b4f882940854b1d318af11a9958a9a4a62b2e37ccf75a555e9f35adad00d4373</originalsourceid><addsrcrecordid>eNp1kktv1DAQxyMEoqVw54R85LJgx89wQFqq0q60EhLQXq2JMymunHixnUr7PfjAZLvL8pA4WPY8_r-xx1NVLxl9w5jWb5nknHKhmFJGC60fVac714Jybh4fz0KdVM9yvqO0Voqzp9VJbWjDGylPqx_LEUocvIMQtuQzQvC5eEe--GEKUHwcM4k9Wft7TGTZ7l2k3ZJVSjj7sm8DkouArqS4iekh_o6shg24slN-CDF25AZzxjCjxt-QmximATOBsSPXY4epJIQy4FieV096CBlfHPaz6vrjxdfzq8X60-XqfLleOKFVWehW9MbUjaBGipZ1nBnoGYOmkQYaEKDqtkauneu1BCklNj2X0EFHaSe45mfV-z13M7UDdm4unSDYTfIDpK2N4O3fkdF_s7fx3kqt6rnHM4DtAS5PziZ0mByUB-HR2K2a6tpyppg2s-b1oWiK3yfMxQ4-OwwBRoxTtswoJoWQms2p9IBPMeeE_fFqjNrdANh_B2CWvPrzSUfBrx-fExb7hAy3aO_ilMa5xf8H_gQz27vp</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1861544571</pqid></control><display><type>article</type><title>Anatomically Realistic Simulations of Liver Ablation by Irreversible Electroporation: Impact of Blood Vessels on Ablation Volumes and Undertreatment</title><source>Sage Journals GOLD Open Access 2024</source><source>Recercat</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>Qasrawi, Radwan ; Silve, Louis ; Burdío, Fernando ; Abdeen, Ziad ; Ivorra, Antoni</creator><creatorcontrib>Qasrawi, Radwan ; Silve, Louis ; Burdío, Fernando ; Abdeen, Ziad ; Ivorra, Antoni</creatorcontrib><description>Irreversible electroporation is a novel tissue ablation technique which entails delivering intense electrical pulses to target tissue, hence producing fatal defects in the cell membrane. The present study numerically analyzes the potential impact of liver blood vessels on ablation by irreversible electroporation because of their influence on the electric field distribution. An anatomically realistic computer model of the liver and its vasculature within an abdominal section was employed, and blood vessels down to 0.4 mm in diameter were considered. In this model, the electric field distribution was simulated in a large series of scenarios (N = 576) corresponding to plausible percutaneous irreversible electroporation treatments by needle electrode pairs. These modeled treatments were relatively superficial (maximum penetration depth of the electrode within the liver = 26 mm) and it was ensured that the electrodes did not penetrate the vessels nor were in contact with them. In terms of total ablation volume, the maximum deviation caused by the presence of the vessels was 6%, which could be considered negligible compared to the impact by other sources of uncertainty. Sublethal field magnitudes were noticed around vessels covering volumes of up to 228 mm3. If in this model the blood was substituted by a liquid with a low electrical conductivity (0.1 S/m), the maximum volume covered by sublethal field magnitudes was 3.7 mm3 and almost no sublethal regions were observable. We conclude that undertreatment around blood vessels may occur in current liver ablation procedures by irreversible electroporation. Infusion of isotonic low conductivity liquids into the liver vasculature could prevent this risk.</description><identifier>ISSN: 1533-0346</identifier><identifier>EISSN: 1533-0338</identifier><identifier>DOI: 10.1177/1533034616687477</identifier><identifier>PMID: 28093955</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Blood vessels ; Conductivity ; Irreversible electroporation ; Liver ; Numerical modeling ; Original</subject><ispartof>Technology in cancer research & treatment, 2017-12, Vol.16 (6), p.783-792</ispartof><rights>The Author(s) 2017</rights><rights>info:eu-repo/semantics/openAccess This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License (<a href="http://www.creativecommons.org/licenses/by-nc/3.0/">http://www.creativecommons.org/licenses/by-nc/3.0/</a>) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). <a href="http://www.creativecommons.org/licenses/by-nc/3.0/">http://www.creativecommons.org/licenses/by-nc/3.0/</a></rights><rights>The Author(s) 2017 2017 SAGE Publications</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c476t-7b4f882940854b1d318af11a9958a9a4a62b2e37ccf75a555e9f35adad00d4373</citedby><cites>FETCH-LOGICAL-c476t-7b4f882940854b1d318af11a9958a9a4a62b2e37ccf75a555e9f35adad00d4373</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762033/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762033/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,21966,26974,27853,27924,27925,44945,45333,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28093955$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Qasrawi, Radwan</creatorcontrib><creatorcontrib>Silve, Louis</creatorcontrib><creatorcontrib>Burdío, Fernando</creatorcontrib><creatorcontrib>Abdeen, Ziad</creatorcontrib><creatorcontrib>Ivorra, Antoni</creatorcontrib><title>Anatomically Realistic Simulations of Liver Ablation by Irreversible Electroporation: Impact of Blood Vessels on Ablation Volumes and Undertreatment</title><title>Technology in cancer research & treatment</title><addtitle>Technol Cancer Res Treat</addtitle><description>Irreversible electroporation is a novel tissue ablation technique which entails delivering intense electrical pulses to target tissue, hence producing fatal defects in the cell membrane. The present study numerically analyzes the potential impact of liver blood vessels on ablation by irreversible electroporation because of their influence on the electric field distribution. An anatomically realistic computer model of the liver and its vasculature within an abdominal section was employed, and blood vessels down to 0.4 mm in diameter were considered. In this model, the electric field distribution was simulated in a large series of scenarios (N = 576) corresponding to plausible percutaneous irreversible electroporation treatments by needle electrode pairs. These modeled treatments were relatively superficial (maximum penetration depth of the electrode within the liver = 26 mm) and it was ensured that the electrodes did not penetrate the vessels nor were in contact with them. In terms of total ablation volume, the maximum deviation caused by the presence of the vessels was 6%, which could be considered negligible compared to the impact by other sources of uncertainty. Sublethal field magnitudes were noticed around vessels covering volumes of up to 228 mm3. If in this model the blood was substituted by a liquid with a low electrical conductivity (0.1 S/m), the maximum volume covered by sublethal field magnitudes was 3.7 mm3 and almost no sublethal regions were observable. We conclude that undertreatment around blood vessels may occur in current liver ablation procedures by irreversible electroporation. Infusion of isotonic low conductivity liquids into the liver vasculature could prevent this risk.</description><subject>Blood vessels</subject><subject>Conductivity</subject><subject>Irreversible electroporation</subject><subject>Liver</subject><subject>Numerical modeling</subject><subject>Original</subject><issn>1533-0346</issn><issn>1533-0338</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>AFRWT</sourceid><sourceid>XX2</sourceid><recordid>eNp1kktv1DAQxyMEoqVw54R85LJgx89wQFqq0q60EhLQXq2JMymunHixnUr7PfjAZLvL8pA4WPY8_r-xx1NVLxl9w5jWb5nknHKhmFJGC60fVac714Jybh4fz0KdVM9yvqO0Voqzp9VJbWjDGylPqx_LEUocvIMQtuQzQvC5eEe--GEKUHwcM4k9Wft7TGTZ7l2k3ZJVSjj7sm8DkouArqS4iekh_o6shg24slN-CDF25AZzxjCjxt-QmximATOBsSPXY4epJIQy4FieV096CBlfHPaz6vrjxdfzq8X60-XqfLleOKFVWehW9MbUjaBGipZ1nBnoGYOmkQYaEKDqtkauneu1BCklNj2X0EFHaSe45mfV-z13M7UDdm4unSDYTfIDpK2N4O3fkdF_s7fx3kqt6rnHM4DtAS5PziZ0mByUB-HR2K2a6tpyppg2s-b1oWiK3yfMxQ4-OwwBRoxTtswoJoWQms2p9IBPMeeE_fFqjNrdANh_B2CWvPrzSUfBrx-fExb7hAy3aO_ilMa5xf8H_gQz27vp</recordid><startdate>20171201</startdate><enddate>20171201</enddate><creator>Qasrawi, Radwan</creator><creator>Silve, Louis</creator><creator>Burdío, Fernando</creator><creator>Abdeen, Ziad</creator><creator>Ivorra, Antoni</creator><general>SAGE Publications</general><scope>AFRWT</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>XX2</scope><scope>5PM</scope></search><sort><creationdate>20171201</creationdate><title>Anatomically Realistic Simulations of Liver Ablation by Irreversible Electroporation: Impact of Blood Vessels on Ablation Volumes and Undertreatment</title><author>Qasrawi, Radwan ; Silve, Louis ; Burdío, Fernando ; Abdeen, Ziad ; Ivorra, Antoni</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c476t-7b4f882940854b1d318af11a9958a9a4a62b2e37ccf75a555e9f35adad00d4373</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Blood vessels</topic><topic>Conductivity</topic><topic>Irreversible electroporation</topic><topic>Liver</topic><topic>Numerical modeling</topic><topic>Original</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Qasrawi, Radwan</creatorcontrib><creatorcontrib>Silve, Louis</creatorcontrib><creatorcontrib>Burdío, Fernando</creatorcontrib><creatorcontrib>Abdeen, Ziad</creatorcontrib><creatorcontrib>Ivorra, Antoni</creatorcontrib><collection>Sage Journals GOLD Open Access 2024</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Recercat</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Technology in cancer research & treatment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Qasrawi, Radwan</au><au>Silve, Louis</au><au>Burdío, Fernando</au><au>Abdeen, Ziad</au><au>Ivorra, Antoni</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Anatomically Realistic Simulations of Liver Ablation by Irreversible Electroporation: Impact of Blood Vessels on Ablation Volumes and Undertreatment</atitle><jtitle>Technology in cancer research & treatment</jtitle><addtitle>Technol Cancer Res Treat</addtitle><date>2017-12-01</date><risdate>2017</risdate><volume>16</volume><issue>6</issue><spage>783</spage><epage>792</epage><pages>783-792</pages><issn>1533-0346</issn><eissn>1533-0338</eissn><abstract>Irreversible electroporation is a novel tissue ablation technique which entails delivering intense electrical pulses to target tissue, hence producing fatal defects in the cell membrane. The present study numerically analyzes the potential impact of liver blood vessels on ablation by irreversible electroporation because of their influence on the electric field distribution. An anatomically realistic computer model of the liver and its vasculature within an abdominal section was employed, and blood vessels down to 0.4 mm in diameter were considered. In this model, the electric field distribution was simulated in a large series of scenarios (N = 576) corresponding to plausible percutaneous irreversible electroporation treatments by needle electrode pairs. These modeled treatments were relatively superficial (maximum penetration depth of the electrode within the liver = 26 mm) and it was ensured that the electrodes did not penetrate the vessels nor were in contact with them. In terms of total ablation volume, the maximum deviation caused by the presence of the vessels was 6%, which could be considered negligible compared to the impact by other sources of uncertainty. Sublethal field magnitudes were noticed around vessels covering volumes of up to 228 mm3. If in this model the blood was substituted by a liquid with a low electrical conductivity (0.1 S/m), the maximum volume covered by sublethal field magnitudes was 3.7 mm3 and almost no sublethal regions were observable. We conclude that undertreatment around blood vessels may occur in current liver ablation procedures by irreversible electroporation. Infusion of isotonic low conductivity liquids into the liver vasculature could prevent this risk.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>28093955</pmid><doi>10.1177/1533034616687477</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1533-0346 |
ispartof | Technology in cancer research & treatment, 2017-12, Vol.16 (6), p.783-792 |
issn | 1533-0346 1533-0338 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5762033 |
source | Sage Journals GOLD Open Access 2024; Recercat; EZB-FREE-00999 freely available EZB journals; PubMed Central |
subjects | Blood vessels Conductivity Irreversible electroporation Liver Numerical modeling Original |
title | Anatomically Realistic Simulations of Liver Ablation by Irreversible Electroporation: Impact of Blood Vessels on Ablation Volumes and Undertreatment |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T12%3A38%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Anatomically%20Realistic%20Simulations%20of%20Liver%20Ablation%20by%20Irreversible%20Electroporation:%20Impact%20of%20Blood%20Vessels%20on%20Ablation%20Volumes%20and%20Undertreatment&rft.jtitle=Technology%20in%20cancer%20research%20&%20treatment&rft.au=Qasrawi,%20Radwan&rft.date=2017-12-01&rft.volume=16&rft.issue=6&rft.spage=783&rft.epage=792&rft.pages=783-792&rft.issn=1533-0346&rft.eissn=1533-0338&rft_id=info:doi/10.1177/1533034616687477&rft_dat=%3Cproquest_pubme%3E1861544571%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1861544571&rft_id=info:pmid/28093955&rft_sage_id=10.1177_1533034616687477&rfr_iscdi=true |