Morphological Changes in Blood Cells After Implantation of Titanium and Plastic Clips in the Neurocranium - Experimental Study on Dogs
Various studies confirm the biocompatibility and efficacy of clips for certain target tissues, but without any comparative analysis of hematological parameters. Therefore, we conducted a study to assess the possible association of the implantation of titanium and plastic clips in the neurocranium wi...
Gespeichert in:
Veröffentlicht in: | Medicinski arhiv 2017-04, Vol.71 (2), p.84-88 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 88 |
---|---|
container_issue | 2 |
container_start_page | 84 |
container_title | Medicinski arhiv |
container_volume | 71 |
creator | Katica, Muhamed Celebicic, Mirza Gradascevic, Nedzad Obhodzas, Muamer Suljić, Enra Ocuz, Muhamed Delibegovic, Samir |
description | Various studies confirm the biocompatibility and efficacy of clips for certain target tissues, but without any comparative analysis of hematological parameters. Therefore, we conducted a study to assess the possible association of the implantation of titanium and plastic clips in the neurocranium with possible morphological changes in the blood cells of experimental animals.
As a control, the peripheral blood smears were taken before surgery from 12 adult dogs that were divided into two experimental groups. After placing titanium and plastic clips in the neurocranium, the peripheral blood of the first group was analyzed on the seventh postoperative day, while the peripheral blood of the second group was analyzed on the sixtieth day. By microscopy of the blood smears, the following parameters were analyzed: the presence of poikilocytosis of the red blood cells, degenerative changes in the leukocytes and leukogram.
There were no statistically significant differences between the mean values of the groups. Monocytosis was detected (first group 22.83 % and second 16.30 %), as well as neutropenia (46.80 %, in the second group). Degenerative changes to neutrophils and the occurrence of atypical lymphocytes were observed in the second experimental group (60
postoperative day).
A mild adverse effect from the biomaterials present in the neurocranium of dogs was detected, affecting the majority of leukocytic cells. A chronic recurrent inflammatory process was caused by the presence of the plastic and titanium clips in the brain tissue. No adverse effect of biomaterials on erythrocytes in the neurocranium was detected in the dogs studied. Further studies are necessary to explain the occurrence of degenerative changes in the neutrophils and lymphocytes. |
doi_str_mv | 10.5455/medarh.2017.71.84-88 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5511527</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1899837762</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3008-cbac02f6975f5497c04637c2d6b5894306aace1f365d811131f3483c6a3be633</originalsourceid><addsrcrecordid>eNpdkc1u1DAUhS0EokPhDRCyxIZNBjv-3yCVUKBS-ZGYBTvL4zgTV44d7ATRF-C5cZlSAStfyd85OvceAJ5itGWUsZeT600ety3CYivwVtJGyntgg5XkDVMc3wcbRBhqsFJfT8CjUq4QYkq06iE4aaVQiBG2AT8_pDyPKaSDtybAbjTx4Ar0Eb4OKfWwcyEUeDYsLsOLaQ4mLmbxKcI0wJ1fTPTrBE3s4edgyuIt7IKff-uX0cGPbs3J5iPVwPMfs8t-ctUjwC_L2l_D6vQmHcpj8GAwobgnt-8p2L0933Xvm8tP7y66s8vGEoRkY_fGonbgSrCBUSUsopwI2_Z8z6SiBHFjrMMD4ayXGGNSRyqJ5YbsHSfkFLw62s7rvt7P1iTZBD3XUCZf62S8_vcn-lEf0nfNGMasFdXgxa1BTt9WVxY9-WLrjUx0aS0aq1ZwhKjAFX3-H3qV1hzrdhpLpSQRgreVokfK5lRKdsNdGIz0Tc_62LO-6VkLrCXVUlbZs78XuRP9KZb8AsDSpw0</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1899837762</pqid></control><display><type>article</type><title>Morphological Changes in Blood Cells After Implantation of Titanium and Plastic Clips in the Neurocranium - Experimental Study on Dogs</title><source>MEDLINE</source><source>PubMed Central Open Access</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>Katica, Muhamed ; Celebicic, Mirza ; Gradascevic, Nedzad ; Obhodzas, Muamer ; Suljić, Enra ; Ocuz, Muhamed ; Delibegovic, Samir</creator><creatorcontrib>Katica, Muhamed ; Celebicic, Mirza ; Gradascevic, Nedzad ; Obhodzas, Muamer ; Suljić, Enra ; Ocuz, Muhamed ; Delibegovic, Samir</creatorcontrib><description>Various studies confirm the biocompatibility and efficacy of clips for certain target tissues, but without any comparative analysis of hematological parameters. Therefore, we conducted a study to assess the possible association of the implantation of titanium and plastic clips in the neurocranium with possible morphological changes in the blood cells of experimental animals.
As a control, the peripheral blood smears were taken before surgery from 12 adult dogs that were divided into two experimental groups. After placing titanium and plastic clips in the neurocranium, the peripheral blood of the first group was analyzed on the seventh postoperative day, while the peripheral blood of the second group was analyzed on the sixtieth day. By microscopy of the blood smears, the following parameters were analyzed: the presence of poikilocytosis of the red blood cells, degenerative changes in the leukocytes and leukogram.
There were no statistically significant differences between the mean values of the groups. Monocytosis was detected (first group 22.83 % and second 16.30 %), as well as neutropenia (46.80 %, in the second group). Degenerative changes to neutrophils and the occurrence of atypical lymphocytes were observed in the second experimental group (60
postoperative day).
A mild adverse effect from the biomaterials present in the neurocranium of dogs was detected, affecting the majority of leukocytic cells. A chronic recurrent inflammatory process was caused by the presence of the plastic and titanium clips in the brain tissue. No adverse effect of biomaterials on erythrocytes in the neurocranium was detected in the dogs studied. Further studies are necessary to explain the occurrence of degenerative changes in the neutrophils and lymphocytes.</description><identifier>ISSN: 0350-199X</identifier><identifier>EISSN: 1986-5961</identifier><identifier>DOI: 10.5455/medarh.2017.71.84-88</identifier><identifier>PMID: 28790535</identifier><language>eng</language><publisher>Bosnia and Herzegovina: Academy of Medical Sciences of Bosnia and Herzegovina</publisher><subject>Animals ; Biomedical materials ; Blood ; Blood Cells - pathology ; Dogs ; Erythrocytes, Abnormal - pathology ; Leukocytosis - pathology ; Monocytes - pathology ; Morphology ; Neutropenia - pathology ; Neutrophils ; Original Paper ; Plastics - toxicity ; Skull - pathology ; Surgical Instruments - adverse effects ; Titanium ; Titanium - toxicity</subject><ispartof>Medicinski arhiv, 2017-04, Vol.71 (2), p.84-88</ispartof><rights>Copyright Academy of Medical Sciences of Bosnia and Herzegovina 2017</rights><rights>Copyright: © 2017 Muhamed Katica, Mirza Celebicic, Nedzad Gradascevic, Muamer Obhodzas, Enra M. Suljić, Muhamed Ocuz, Samir Delibegovic 2017</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5511527/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5511527/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28790535$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Katica, Muhamed</creatorcontrib><creatorcontrib>Celebicic, Mirza</creatorcontrib><creatorcontrib>Gradascevic, Nedzad</creatorcontrib><creatorcontrib>Obhodzas, Muamer</creatorcontrib><creatorcontrib>Suljić, Enra</creatorcontrib><creatorcontrib>Ocuz, Muhamed</creatorcontrib><creatorcontrib>Delibegovic, Samir</creatorcontrib><title>Morphological Changes in Blood Cells After Implantation of Titanium and Plastic Clips in the Neurocranium - Experimental Study on Dogs</title><title>Medicinski arhiv</title><addtitle>Med Arch</addtitle><description>Various studies confirm the biocompatibility and efficacy of clips for certain target tissues, but without any comparative analysis of hematological parameters. Therefore, we conducted a study to assess the possible association of the implantation of titanium and plastic clips in the neurocranium with possible morphological changes in the blood cells of experimental animals.
As a control, the peripheral blood smears were taken before surgery from 12 adult dogs that were divided into two experimental groups. After placing titanium and plastic clips in the neurocranium, the peripheral blood of the first group was analyzed on the seventh postoperative day, while the peripheral blood of the second group was analyzed on the sixtieth day. By microscopy of the blood smears, the following parameters were analyzed: the presence of poikilocytosis of the red blood cells, degenerative changes in the leukocytes and leukogram.
There were no statistically significant differences between the mean values of the groups. Monocytosis was detected (first group 22.83 % and second 16.30 %), as well as neutropenia (46.80 %, in the second group). Degenerative changes to neutrophils and the occurrence of atypical lymphocytes were observed in the second experimental group (60
postoperative day).
A mild adverse effect from the biomaterials present in the neurocranium of dogs was detected, affecting the majority of leukocytic cells. A chronic recurrent inflammatory process was caused by the presence of the plastic and titanium clips in the brain tissue. No adverse effect of biomaterials on erythrocytes in the neurocranium was detected in the dogs studied. Further studies are necessary to explain the occurrence of degenerative changes in the neutrophils and lymphocytes.</description><subject>Animals</subject><subject>Biomedical materials</subject><subject>Blood</subject><subject>Blood Cells - pathology</subject><subject>Dogs</subject><subject>Erythrocytes, Abnormal - pathology</subject><subject>Leukocytosis - pathology</subject><subject>Monocytes - pathology</subject><subject>Morphology</subject><subject>Neutropenia - pathology</subject><subject>Neutrophils</subject><subject>Original Paper</subject><subject>Plastics - toxicity</subject><subject>Skull - pathology</subject><subject>Surgical Instruments - adverse effects</subject><subject>Titanium</subject><subject>Titanium - toxicity</subject><issn>0350-199X</issn><issn>1986-5961</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNpdkc1u1DAUhS0EokPhDRCyxIZNBjv-3yCVUKBS-ZGYBTvL4zgTV44d7ATRF-C5cZlSAStfyd85OvceAJ5itGWUsZeT600ety3CYivwVtJGyntgg5XkDVMc3wcbRBhqsFJfT8CjUq4QYkq06iE4aaVQiBG2AT8_pDyPKaSDtybAbjTx4Ar0Eb4OKfWwcyEUeDYsLsOLaQ4mLmbxKcI0wJ1fTPTrBE3s4edgyuIt7IKff-uX0cGPbs3J5iPVwPMfs8t-ctUjwC_L2l_D6vQmHcpj8GAwobgnt-8p2L0933Xvm8tP7y66s8vGEoRkY_fGonbgSrCBUSUsopwI2_Z8z6SiBHFjrMMD4ayXGGNSRyqJ5YbsHSfkFLw62s7rvt7P1iTZBD3XUCZf62S8_vcn-lEf0nfNGMasFdXgxa1BTt9WVxY9-WLrjUx0aS0aq1ZwhKjAFX3-H3qV1hzrdhpLpSQRgreVokfK5lRKdsNdGIz0Tc_62LO-6VkLrCXVUlbZs78XuRP9KZb8AsDSpw0</recordid><startdate>20170401</startdate><enddate>20170401</enddate><creator>Katica, Muhamed</creator><creator>Celebicic, Mirza</creator><creator>Gradascevic, Nedzad</creator><creator>Obhodzas, Muamer</creator><creator>Suljić, Enra</creator><creator>Ocuz, Muhamed</creator><creator>Delibegovic, Samir</creator><general>Academy of Medical Sciences of Bosnia and Herzegovina</general><general>AVICENA, d.o.o., Sarajevo</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BYOGL</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20170401</creationdate><title>Morphological Changes in Blood Cells After Implantation of Titanium and Plastic Clips in the Neurocranium - Experimental Study on Dogs</title><author>Katica, Muhamed ; Celebicic, Mirza ; Gradascevic, Nedzad ; Obhodzas, Muamer ; Suljić, Enra ; Ocuz, Muhamed ; Delibegovic, Samir</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3008-cbac02f6975f5497c04637c2d6b5894306aace1f365d811131f3483c6a3be633</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Animals</topic><topic>Biomedical materials</topic><topic>Blood</topic><topic>Blood Cells - pathology</topic><topic>Dogs</topic><topic>Erythrocytes, Abnormal - pathology</topic><topic>Leukocytosis - pathology</topic><topic>Monocytes - pathology</topic><topic>Morphology</topic><topic>Neutropenia - pathology</topic><topic>Neutrophils</topic><topic>Original Paper</topic><topic>Plastics - toxicity</topic><topic>Skull - pathology</topic><topic>Surgical Instruments - adverse effects</topic><topic>Titanium</topic><topic>Titanium - toxicity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Katica, Muhamed</creatorcontrib><creatorcontrib>Celebicic, Mirza</creatorcontrib><creatorcontrib>Gradascevic, Nedzad</creatorcontrib><creatorcontrib>Obhodzas, Muamer</creatorcontrib><creatorcontrib>Suljić, Enra</creatorcontrib><creatorcontrib>Ocuz, Muhamed</creatorcontrib><creatorcontrib>Delibegovic, Samir</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>East Europe, Central Europe Database</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Medicinski arhiv</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Katica, Muhamed</au><au>Celebicic, Mirza</au><au>Gradascevic, Nedzad</au><au>Obhodzas, Muamer</au><au>Suljić, Enra</au><au>Ocuz, Muhamed</au><au>Delibegovic, Samir</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Morphological Changes in Blood Cells After Implantation of Titanium and Plastic Clips in the Neurocranium - Experimental Study on Dogs</atitle><jtitle>Medicinski arhiv</jtitle><addtitle>Med Arch</addtitle><date>2017-04-01</date><risdate>2017</risdate><volume>71</volume><issue>2</issue><spage>84</spage><epage>88</epage><pages>84-88</pages><issn>0350-199X</issn><eissn>1986-5961</eissn><abstract>Various studies confirm the biocompatibility and efficacy of clips for certain target tissues, but without any comparative analysis of hematological parameters. Therefore, we conducted a study to assess the possible association of the implantation of titanium and plastic clips in the neurocranium with possible morphological changes in the blood cells of experimental animals.
As a control, the peripheral blood smears were taken before surgery from 12 adult dogs that were divided into two experimental groups. After placing titanium and plastic clips in the neurocranium, the peripheral blood of the first group was analyzed on the seventh postoperative day, while the peripheral blood of the second group was analyzed on the sixtieth day. By microscopy of the blood smears, the following parameters were analyzed: the presence of poikilocytosis of the red blood cells, degenerative changes in the leukocytes and leukogram.
There were no statistically significant differences between the mean values of the groups. Monocytosis was detected (first group 22.83 % and second 16.30 %), as well as neutropenia (46.80 %, in the second group). Degenerative changes to neutrophils and the occurrence of atypical lymphocytes were observed in the second experimental group (60
postoperative day).
A mild adverse effect from the biomaterials present in the neurocranium of dogs was detected, affecting the majority of leukocytic cells. A chronic recurrent inflammatory process was caused by the presence of the plastic and titanium clips in the brain tissue. No adverse effect of biomaterials on erythrocytes in the neurocranium was detected in the dogs studied. Further studies are necessary to explain the occurrence of degenerative changes in the neutrophils and lymphocytes.</abstract><cop>Bosnia and Herzegovina</cop><pub>Academy of Medical Sciences of Bosnia and Herzegovina</pub><pmid>28790535</pmid><doi>10.5455/medarh.2017.71.84-88</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0350-199X |
ispartof | Medicinski arhiv, 2017-04, Vol.71 (2), p.84-88 |
issn | 0350-199X 1986-5961 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5511527 |
source | MEDLINE; PubMed Central Open Access; EZB-FREE-00999 freely available EZB journals; PubMed Central |
subjects | Animals Biomedical materials Blood Blood Cells - pathology Dogs Erythrocytes, Abnormal - pathology Leukocytosis - pathology Monocytes - pathology Morphology Neutropenia - pathology Neutrophils Original Paper Plastics - toxicity Skull - pathology Surgical Instruments - adverse effects Titanium Titanium - toxicity |
title | Morphological Changes in Blood Cells After Implantation of Titanium and Plastic Clips in the Neurocranium - Experimental Study on Dogs |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T09%3A23%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Morphological%20Changes%20in%20Blood%20Cells%20After%20Implantation%20of%20Titanium%20and%20Plastic%20Clips%20in%20the%20Neurocranium%20-%20Experimental%20Study%20on%20Dogs&rft.jtitle=Medicinski%20arhiv&rft.au=Katica,%20Muhamed&rft.date=2017-04-01&rft.volume=71&rft.issue=2&rft.spage=84&rft.epage=88&rft.pages=84-88&rft.issn=0350-199X&rft.eissn=1986-5961&rft_id=info:doi/10.5455/medarh.2017.71.84-88&rft_dat=%3Cproquest_pubme%3E1899837762%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1899837762&rft_id=info:pmid/28790535&rfr_iscdi=true |