Methods to determine limit of detection and limit of quantification in quantitative real-time PCR (qPCR)

Quantitative Real-Time Polymerase Chain Reaction, better known as qPCR, is the most sensitive and specific technique we have for the detection of nucleic acids. Even though it has been around for more than 30 years and is preferred in research applications, it has yet to win broad acceptance in rout...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomolecular detection and quantification 2017-06, Vol.12, p.1-6
Hauptverfasser: Forootan, Amin, Sjöback, Robert, Björkman, Jens, Sjögreen, Björn, Linz, Lucas, Kubista, Mikael
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 6
container_issue
container_start_page 1
container_title Biomolecular detection and quantification
container_volume 12
creator Forootan, Amin
Sjöback, Robert
Björkman, Jens
Sjögreen, Björn
Linz, Lucas
Kubista, Mikael
description Quantitative Real-Time Polymerase Chain Reaction, better known as qPCR, is the most sensitive and specific technique we have for the detection of nucleic acids. Even though it has been around for more than 30 years and is preferred in research applications, it has yet to win broad acceptance in routine practice. This requires a means to unambiguously assess the performance of specific qPCR analyses. Here we present methods to determine the limit of detection (LoD) and the limit of quantification (LoQ) as applicable to qPCR. These are based on standard statistical methods as recommended by regulatory bodies adapted to qPCR and complemented with a novel approach to estimate the precision of LoD.
doi_str_mv 10.1016/j.bdq.2017.04.001
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5496743</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2214753516300286</els_id><sourcerecordid>1918850853</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4321-dd471d405bb5bc984c7a9bfa8af4c1dcd6a0af7cccd136202df22b05fca8d3c03</originalsourceid><addsrcrecordid>eNp9kVFvFCEUhYnR2KbtD_DFzGN9mBEYmJmNiYnZaGvSxqbRZ8JcLi6bGegCu4n_Xra71vriC3DPPfdA-Ah5w2jDKOver5vRbBpOWd9Q0VDKXpBTzpmoe9nKl8_OJ-QipTUtDil4K7vX5IQPPeVt152S1S3mVTCpyqEymDHOzmM1udnlKthHCbILvtLe_JU3W-2zsw70Y8_5o5JLvcMqop7q7Gas7pb31eWmrO_OySurp4QXx_2M_Pjy-fvyur75dvV1-emmBtFyVhsjemYEleMoR1gMAnq9GK0etBXADJhOU217ADCs7TjlxnI-UmlBD6YF2p6Rj4fch-04owH0OepJPUQ36_hLBe3Uvx3vVupn2CkpFl0v2hJweQyIYbPFlNXsEuA0aY9hmxRbsGGQdJB7KztYIYaUItqnaxhVe0hqrQoktYekqFAFQZl5-_x9TxN_kBTDh4MByy_tHEaVwKEHNC4WFsoE95_437uWpIw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1918850853</pqid></control><display><type>article</type><title>Methods to determine limit of detection and limit of quantification in quantitative real-time PCR (qPCR)</title><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Forootan, Amin ; Sjöback, Robert ; Björkman, Jens ; Sjögreen, Björn ; Linz, Lucas ; Kubista, Mikael</creator><creatorcontrib>Forootan, Amin ; Sjöback, Robert ; Björkman, Jens ; Sjögreen, Björn ; Linz, Lucas ; Kubista, Mikael</creatorcontrib><description>Quantitative Real-Time Polymerase Chain Reaction, better known as qPCR, is the most sensitive and specific technique we have for the detection of nucleic acids. Even though it has been around for more than 30 years and is preferred in research applications, it has yet to win broad acceptance in routine practice. This requires a means to unambiguously assess the performance of specific qPCR analyses. Here we present methods to determine the limit of detection (LoD) and the limit of quantification (LoQ) as applicable to qPCR. These are based on standard statistical methods as recommended by regulatory bodies adapted to qPCR and complemented with a novel approach to estimate the precision of LoD.</description><identifier>ISSN: 2214-7535</identifier><identifier>EISSN: 2214-7535</identifier><identifier>DOI: 10.1016/j.bdq.2017.04.001</identifier><identifier>PMID: 28702366</identifier><language>eng</language><publisher>Germany: Elsevier GmbH</publisher><subject>Data analysis ; GenEx software ; Limit of detection ; Limit of quantification ; LoD ; LoQ ; MIQE ; qPCR ; Quality control ; Real-time PCR ; Replicates ; Research Paper ; Standardization</subject><ispartof>Biomolecular detection and quantification, 2017-06, Vol.12, p.1-6</ispartof><rights>2017</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4321-dd471d405bb5bc984c7a9bfa8af4c1dcd6a0af7cccd136202df22b05fca8d3c03</citedby><cites>FETCH-LOGICAL-c4321-dd471d405bb5bc984c7a9bfa8af4c1dcd6a0af7cccd136202df22b05fca8d3c03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5496743/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5496743/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27923,27924,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28702366$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Forootan, Amin</creatorcontrib><creatorcontrib>Sjöback, Robert</creatorcontrib><creatorcontrib>Björkman, Jens</creatorcontrib><creatorcontrib>Sjögreen, Björn</creatorcontrib><creatorcontrib>Linz, Lucas</creatorcontrib><creatorcontrib>Kubista, Mikael</creatorcontrib><title>Methods to determine limit of detection and limit of quantification in quantitative real-time PCR (qPCR)</title><title>Biomolecular detection and quantification</title><addtitle>Biomol Detect Quantif</addtitle><description>Quantitative Real-Time Polymerase Chain Reaction, better known as qPCR, is the most sensitive and specific technique we have for the detection of nucleic acids. Even though it has been around for more than 30 years and is preferred in research applications, it has yet to win broad acceptance in routine practice. This requires a means to unambiguously assess the performance of specific qPCR analyses. Here we present methods to determine the limit of detection (LoD) and the limit of quantification (LoQ) as applicable to qPCR. These are based on standard statistical methods as recommended by regulatory bodies adapted to qPCR and complemented with a novel approach to estimate the precision of LoD.</description><subject>Data analysis</subject><subject>GenEx software</subject><subject>Limit of detection</subject><subject>Limit of quantification</subject><subject>LoD</subject><subject>LoQ</subject><subject>MIQE</subject><subject>qPCR</subject><subject>Quality control</subject><subject>Real-time PCR</subject><subject>Replicates</subject><subject>Research Paper</subject><subject>Standardization</subject><issn>2214-7535</issn><issn>2214-7535</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp9kVFvFCEUhYnR2KbtD_DFzGN9mBEYmJmNiYnZaGvSxqbRZ8JcLi6bGegCu4n_Xra71vriC3DPPfdA-Ah5w2jDKOver5vRbBpOWd9Q0VDKXpBTzpmoe9nKl8_OJ-QipTUtDil4K7vX5IQPPeVt152S1S3mVTCpyqEymDHOzmM1udnlKthHCbILvtLe_JU3W-2zsw70Y8_5o5JLvcMqop7q7Gas7pb31eWmrO_OySurp4QXx_2M_Pjy-fvyur75dvV1-emmBtFyVhsjemYEleMoR1gMAnq9GK0etBXADJhOU217ADCs7TjlxnI-UmlBD6YF2p6Rj4fch-04owH0OepJPUQ36_hLBe3Uvx3vVupn2CkpFl0v2hJweQyIYbPFlNXsEuA0aY9hmxRbsGGQdJB7KztYIYaUItqnaxhVe0hqrQoktYekqFAFQZl5-_x9TxN_kBTDh4MByy_tHEaVwKEHNC4WFsoE95_437uWpIw</recordid><startdate>20170601</startdate><enddate>20170601</enddate><creator>Forootan, Amin</creator><creator>Sjöback, Robert</creator><creator>Björkman, Jens</creator><creator>Sjögreen, Björn</creator><creator>Linz, Lucas</creator><creator>Kubista, Mikael</creator><general>Elsevier GmbH</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20170601</creationdate><title>Methods to determine limit of detection and limit of quantification in quantitative real-time PCR (qPCR)</title><author>Forootan, Amin ; Sjöback, Robert ; Björkman, Jens ; Sjögreen, Björn ; Linz, Lucas ; Kubista, Mikael</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4321-dd471d405bb5bc984c7a9bfa8af4c1dcd6a0af7cccd136202df22b05fca8d3c03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Data analysis</topic><topic>GenEx software</topic><topic>Limit of detection</topic><topic>Limit of quantification</topic><topic>LoD</topic><topic>LoQ</topic><topic>MIQE</topic><topic>qPCR</topic><topic>Quality control</topic><topic>Real-time PCR</topic><topic>Replicates</topic><topic>Research Paper</topic><topic>Standardization</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Forootan, Amin</creatorcontrib><creatorcontrib>Sjöback, Robert</creatorcontrib><creatorcontrib>Björkman, Jens</creatorcontrib><creatorcontrib>Sjögreen, Björn</creatorcontrib><creatorcontrib>Linz, Lucas</creatorcontrib><creatorcontrib>Kubista, Mikael</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Biomolecular detection and quantification</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Forootan, Amin</au><au>Sjöback, Robert</au><au>Björkman, Jens</au><au>Sjögreen, Björn</au><au>Linz, Lucas</au><au>Kubista, Mikael</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Methods to determine limit of detection and limit of quantification in quantitative real-time PCR (qPCR)</atitle><jtitle>Biomolecular detection and quantification</jtitle><addtitle>Biomol Detect Quantif</addtitle><date>2017-06-01</date><risdate>2017</risdate><volume>12</volume><spage>1</spage><epage>6</epage><pages>1-6</pages><issn>2214-7535</issn><eissn>2214-7535</eissn><abstract>Quantitative Real-Time Polymerase Chain Reaction, better known as qPCR, is the most sensitive and specific technique we have for the detection of nucleic acids. Even though it has been around for more than 30 years and is preferred in research applications, it has yet to win broad acceptance in routine practice. This requires a means to unambiguously assess the performance of specific qPCR analyses. Here we present methods to determine the limit of detection (LoD) and the limit of quantification (LoQ) as applicable to qPCR. These are based on standard statistical methods as recommended by regulatory bodies adapted to qPCR and complemented with a novel approach to estimate the precision of LoD.</abstract><cop>Germany</cop><pub>Elsevier GmbH</pub><pmid>28702366</pmid><doi>10.1016/j.bdq.2017.04.001</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2214-7535
ispartof Biomolecular detection and quantification, 2017-06, Vol.12, p.1-6
issn 2214-7535
2214-7535
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5496743
source EZB-FREE-00999 freely available EZB journals; PubMed Central; Alma/SFX Local Collection
subjects Data analysis
GenEx software
Limit of detection
Limit of quantification
LoD
LoQ
MIQE
qPCR
Quality control
Real-time PCR
Replicates
Research Paper
Standardization
title Methods to determine limit of detection and limit of quantification in quantitative real-time PCR (qPCR)
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T09%3A47%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Methods%20to%20determine%20limit%20of%20detection%20and%20limit%20of%20quantification%20in%20quantitative%20real-time%20PCR%20(qPCR)&rft.jtitle=Biomolecular%20detection%20and%20quantification&rft.au=Forootan,%20Amin&rft.date=2017-06-01&rft.volume=12&rft.spage=1&rft.epage=6&rft.pages=1-6&rft.issn=2214-7535&rft.eissn=2214-7535&rft_id=info:doi/10.1016/j.bdq.2017.04.001&rft_dat=%3Cproquest_pubme%3E1918850853%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1918850853&rft_id=info:pmid/28702366&rft_els_id=S2214753516300286&rfr_iscdi=true