Enhanced dopamine detection sensitivity by PEDOT/graphene oxide coating on in vivo carbon fiber electrodes
Dopamine (DA) is a monoamine neurotransmitter responsible for regulating a variety of vital life functions. In vivo detection of DA poses a challenge due to the low concentration and high speed of physiological signaling. Fast scan cyclic voltammetry at carbon fiber microelectrodes (CFEs) is an effe...
Gespeichert in:
Veröffentlicht in: | Biosensors & bioelectronics 2017-03, Vol.89 (Pt 1), p.400-410 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 410 |
---|---|
container_issue | Pt 1 |
container_start_page | 400 |
container_title | Biosensors & bioelectronics |
container_volume | 89 |
creator | Taylor, I. Mitch Robbins, Elaine M. Catt, Kasey A. Cody, Patrick A. Happe, Cassandra L. Cui, Xinyan Tracy |
description | Dopamine (DA) is a monoamine neurotransmitter responsible for regulating a variety of vital life functions. In vivo detection of DA poses a challenge due to the low concentration and high speed of physiological signaling. Fast scan cyclic voltammetry at carbon fiber microelectrodes (CFEs) is an effective method to monitor real-time in vivo DA signaling, however the sensitivity is somewhat limited. Electrodeposition of poly(3,4-ethylene dioxythiophene) (PEDOT)/graphene oxide (GO) onto the CFE surface is shown to increase the sensitivity and lower the limit of detection for DA compared to bare CFEs. Thicker PEDOT/GO coatings demonstrate higher sensitivities for DA, but display the negative drawback of slow adsorption and electron transfer kinetics. The moderate thickness resulting from 25 s electrodeposition of PEDOT/GO produces the optimal electrode, exhibiting an 880% increase in sensitivity, a 50% decrease in limit of detection and minimally altered electrode kinetics. PEDOT/GO coated electrodes rapidly and robustly detect DA, both in solution and in the rat dorsal striatum. This increase in DA sensitivity is likely due to increasing the electrode surface area with a PEDOT/GO coating and improved adsorption of DA's oxidation product (DA-o-quinone). Increasing DA sensitivity without compromising electrode kinetics is expected to significantly improve our understanding of the DA function in vivo.
•We developed a PEDOT/GO coated carbon fiber microelectrode for in vivo use.•Electrodes exhibit 880% sensitivity increase for dopamine versus bare carbon fiber.•PEDOT/GO electrodes successfully detected electrically stimulated dopamine in vivo. |
doi_str_mv | 10.1016/j.bios.2016.05.084 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5107160</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0956566316305140</els_id><sourcerecordid>1826691296</sourcerecordid><originalsourceid>FETCH-LOGICAL-c587t-61dc67aa73f9220c1e27390b135391e08c006a9ffaf943555c50f980d30c043f3</originalsourceid><addsrcrecordid>eNqNkU1vEzEQhi0EoqHwBzggH7nsdmyvvWsJIaESPqRK5VDOltc7mzja2MHeRM2_x1FKBRfUk8eaZ17Z8xDylkHNgKmrTd37mGte6hpkDV3zjCxY14qq4UI-JwvQUlVSKXFBXuW8AYCWaXhJLnjLVQdMLMhmGdY2OBzoEHd26wPSAWd0s4-BZgzZz_7g5yPtj_TH8vPt3dUq2d0aCxfv_YDURTv7sKIF94Ee_CFSZ1NfrqPvMVGcSliKA-bX5MVop4xvHs5L8vPL8u76W3Vz-_X79aebysmunSvFBqdaa1sxas7BMeSt0NAzIYVmCJ0DUFaPox11I6SUTsKoOxgEOGjEKC7Jx3Pubt9vcXAY5mQns0t-a9PRROvNv53g12YVD0aysh8FJeD9Q0CKv_aYZ7P12eE02YBxnw3rVCOFEKp5AtqohrGm7Z6AcqU041oVlJ9Rl2LOCcfHxzMwJ_VmY07qzUm9AWmK-jL07u9vP478cV2AD2cAy_IPHpPJzuPJvU_FkRmi_1_-b6QowGU</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1826691296</pqid></control><display><type>article</type><title>Enhanced dopamine detection sensitivity by PEDOT/graphene oxide coating on in vivo carbon fiber electrodes</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Taylor, I. Mitch ; Robbins, Elaine M. ; Catt, Kasey A. ; Cody, Patrick A. ; Happe, Cassandra L. ; Cui, Xinyan Tracy</creator><creatorcontrib>Taylor, I. Mitch ; Robbins, Elaine M. ; Catt, Kasey A. ; Cody, Patrick A. ; Happe, Cassandra L. ; Cui, Xinyan Tracy</creatorcontrib><description>Dopamine (DA) is a monoamine neurotransmitter responsible for regulating a variety of vital life functions. In vivo detection of DA poses a challenge due to the low concentration and high speed of physiological signaling. Fast scan cyclic voltammetry at carbon fiber microelectrodes (CFEs) is an effective method to monitor real-time in vivo DA signaling, however the sensitivity is somewhat limited. Electrodeposition of poly(3,4-ethylene dioxythiophene) (PEDOT)/graphene oxide (GO) onto the CFE surface is shown to increase the sensitivity and lower the limit of detection for DA compared to bare CFEs. Thicker PEDOT/GO coatings demonstrate higher sensitivities for DA, but display the negative drawback of slow adsorption and electron transfer kinetics. The moderate thickness resulting from 25 s electrodeposition of PEDOT/GO produces the optimal electrode, exhibiting an 880% increase in sensitivity, a 50% decrease in limit of detection and minimally altered electrode kinetics. PEDOT/GO coated electrodes rapidly and robustly detect DA, both in solution and in the rat dorsal striatum. This increase in DA sensitivity is likely due to increasing the electrode surface area with a PEDOT/GO coating and improved adsorption of DA's oxidation product (DA-o-quinone). Increasing DA sensitivity without compromising electrode kinetics is expected to significantly improve our understanding of the DA function in vivo.
•We developed a PEDOT/GO coated carbon fiber microelectrode for in vivo use.•Electrodes exhibit 880% sensitivity increase for dopamine versus bare carbon fiber.•PEDOT/GO electrodes successfully detected electrically stimulated dopamine in vivo.</description><identifier>ISSN: 0956-5663</identifier><identifier>EISSN: 1873-4235</identifier><identifier>DOI: 10.1016/j.bios.2016.05.084</identifier><identifier>PMID: 27268013</identifier><language>eng</language><publisher>England: Elsevier B.V</publisher><subject>Animals ; Biosensing Techniques - methods ; Bridged Bicyclo Compounds, Heterocyclic - chemistry ; Carbon fiber ; Carbon fibers ; Coatings ; Corpus Striatum - chemistry ; Dopamine ; Dopamine - analysis ; Electrochemical Techniques - methods ; Electrodeposition ; Electrodes ; Electroplating ; FSCV ; Graphene ; Graphene oxide ; Graphite - chemistry ; Limit of Detection ; Male ; Microelectrodes ; PEDOT ; Polymers - chemistry ; Rats ; Rats, Sprague-Dawley ; Sensitivity ; Surface chemistry</subject><ispartof>Biosensors & bioelectronics, 2017-03, Vol.89 (Pt 1), p.400-410</ispartof><rights>2016 Elsevier B.V.</rights><rights>Copyright © 2016 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c587t-61dc67aa73f9220c1e27390b135391e08c006a9ffaf943555c50f980d30c043f3</citedby><cites>FETCH-LOGICAL-c587t-61dc67aa73f9220c1e27390b135391e08c006a9ffaf943555c50f980d30c043f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.bios.2016.05.084$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,315,781,785,886,3551,27925,27926,45996</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27268013$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Taylor, I. Mitch</creatorcontrib><creatorcontrib>Robbins, Elaine M.</creatorcontrib><creatorcontrib>Catt, Kasey A.</creatorcontrib><creatorcontrib>Cody, Patrick A.</creatorcontrib><creatorcontrib>Happe, Cassandra L.</creatorcontrib><creatorcontrib>Cui, Xinyan Tracy</creatorcontrib><title>Enhanced dopamine detection sensitivity by PEDOT/graphene oxide coating on in vivo carbon fiber electrodes</title><title>Biosensors & bioelectronics</title><addtitle>Biosens Bioelectron</addtitle><description>Dopamine (DA) is a monoamine neurotransmitter responsible for regulating a variety of vital life functions. In vivo detection of DA poses a challenge due to the low concentration and high speed of physiological signaling. Fast scan cyclic voltammetry at carbon fiber microelectrodes (CFEs) is an effective method to monitor real-time in vivo DA signaling, however the sensitivity is somewhat limited. Electrodeposition of poly(3,4-ethylene dioxythiophene) (PEDOT)/graphene oxide (GO) onto the CFE surface is shown to increase the sensitivity and lower the limit of detection for DA compared to bare CFEs. Thicker PEDOT/GO coatings demonstrate higher sensitivities for DA, but display the negative drawback of slow adsorption and electron transfer kinetics. The moderate thickness resulting from 25 s electrodeposition of PEDOT/GO produces the optimal electrode, exhibiting an 880% increase in sensitivity, a 50% decrease in limit of detection and minimally altered electrode kinetics. PEDOT/GO coated electrodes rapidly and robustly detect DA, both in solution and in the rat dorsal striatum. This increase in DA sensitivity is likely due to increasing the electrode surface area with a PEDOT/GO coating and improved adsorption of DA's oxidation product (DA-o-quinone). Increasing DA sensitivity without compromising electrode kinetics is expected to significantly improve our understanding of the DA function in vivo.
•We developed a PEDOT/GO coated carbon fiber microelectrode for in vivo use.•Electrodes exhibit 880% sensitivity increase for dopamine versus bare carbon fiber.•PEDOT/GO electrodes successfully detected electrically stimulated dopamine in vivo.</description><subject>Animals</subject><subject>Biosensing Techniques - methods</subject><subject>Bridged Bicyclo Compounds, Heterocyclic - chemistry</subject><subject>Carbon fiber</subject><subject>Carbon fibers</subject><subject>Coatings</subject><subject>Corpus Striatum - chemistry</subject><subject>Dopamine</subject><subject>Dopamine - analysis</subject><subject>Electrochemical Techniques - methods</subject><subject>Electrodeposition</subject><subject>Electrodes</subject><subject>Electroplating</subject><subject>FSCV</subject><subject>Graphene</subject><subject>Graphene oxide</subject><subject>Graphite - chemistry</subject><subject>Limit of Detection</subject><subject>Male</subject><subject>Microelectrodes</subject><subject>PEDOT</subject><subject>Polymers - chemistry</subject><subject>Rats</subject><subject>Rats, Sprague-Dawley</subject><subject>Sensitivity</subject><subject>Surface chemistry</subject><issn>0956-5663</issn><issn>1873-4235</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNkU1vEzEQhi0EoqHwBzggH7nsdmyvvWsJIaESPqRK5VDOltc7mzja2MHeRM2_x1FKBRfUk8eaZ17Z8xDylkHNgKmrTd37mGte6hpkDV3zjCxY14qq4UI-JwvQUlVSKXFBXuW8AYCWaXhJLnjLVQdMLMhmGdY2OBzoEHd26wPSAWd0s4-BZgzZz_7g5yPtj_TH8vPt3dUq2d0aCxfv_YDURTv7sKIF94Ee_CFSZ1NfrqPvMVGcSliKA-bX5MVop4xvHs5L8vPL8u76W3Vz-_X79aebysmunSvFBqdaa1sxas7BMeSt0NAzIYVmCJ0DUFaPox11I6SUTsKoOxgEOGjEKC7Jx3Pubt9vcXAY5mQns0t-a9PRROvNv53g12YVD0aysh8FJeD9Q0CKv_aYZ7P12eE02YBxnw3rVCOFEKp5AtqohrGm7Z6AcqU041oVlJ9Rl2LOCcfHxzMwJ_VmY07qzUm9AWmK-jL07u9vP478cV2AD2cAy_IPHpPJzuPJvU_FkRmi_1_-b6QowGU</recordid><startdate>20170315</startdate><enddate>20170315</enddate><creator>Taylor, I. Mitch</creator><creator>Robbins, Elaine M.</creator><creator>Catt, Kasey A.</creator><creator>Cody, Patrick A.</creator><creator>Happe, Cassandra L.</creator><creator>Cui, Xinyan Tracy</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7SP</scope><scope>7U5</scope><scope>L7M</scope><scope>5PM</scope></search><sort><creationdate>20170315</creationdate><title>Enhanced dopamine detection sensitivity by PEDOT/graphene oxide coating on in vivo carbon fiber electrodes</title><author>Taylor, I. Mitch ; Robbins, Elaine M. ; Catt, Kasey A. ; Cody, Patrick A. ; Happe, Cassandra L. ; Cui, Xinyan Tracy</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c587t-61dc67aa73f9220c1e27390b135391e08c006a9ffaf943555c50f980d30c043f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Animals</topic><topic>Biosensing Techniques - methods</topic><topic>Bridged Bicyclo Compounds, Heterocyclic - chemistry</topic><topic>Carbon fiber</topic><topic>Carbon fibers</topic><topic>Coatings</topic><topic>Corpus Striatum - chemistry</topic><topic>Dopamine</topic><topic>Dopamine - analysis</topic><topic>Electrochemical Techniques - methods</topic><topic>Electrodeposition</topic><topic>Electrodes</topic><topic>Electroplating</topic><topic>FSCV</topic><topic>Graphene</topic><topic>Graphene oxide</topic><topic>Graphite - chemistry</topic><topic>Limit of Detection</topic><topic>Male</topic><topic>Microelectrodes</topic><topic>PEDOT</topic><topic>Polymers - chemistry</topic><topic>Rats</topic><topic>Rats, Sprague-Dawley</topic><topic>Sensitivity</topic><topic>Surface chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Taylor, I. Mitch</creatorcontrib><creatorcontrib>Robbins, Elaine M.</creatorcontrib><creatorcontrib>Catt, Kasey A.</creatorcontrib><creatorcontrib>Cody, Patrick A.</creatorcontrib><creatorcontrib>Happe, Cassandra L.</creatorcontrib><creatorcontrib>Cui, Xinyan Tracy</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Biosensors & bioelectronics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Taylor, I. Mitch</au><au>Robbins, Elaine M.</au><au>Catt, Kasey A.</au><au>Cody, Patrick A.</au><au>Happe, Cassandra L.</au><au>Cui, Xinyan Tracy</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Enhanced dopamine detection sensitivity by PEDOT/graphene oxide coating on in vivo carbon fiber electrodes</atitle><jtitle>Biosensors & bioelectronics</jtitle><addtitle>Biosens Bioelectron</addtitle><date>2017-03-15</date><risdate>2017</risdate><volume>89</volume><issue>Pt 1</issue><spage>400</spage><epage>410</epage><pages>400-410</pages><issn>0956-5663</issn><eissn>1873-4235</eissn><abstract>Dopamine (DA) is a monoamine neurotransmitter responsible for regulating a variety of vital life functions. In vivo detection of DA poses a challenge due to the low concentration and high speed of physiological signaling. Fast scan cyclic voltammetry at carbon fiber microelectrodes (CFEs) is an effective method to monitor real-time in vivo DA signaling, however the sensitivity is somewhat limited. Electrodeposition of poly(3,4-ethylene dioxythiophene) (PEDOT)/graphene oxide (GO) onto the CFE surface is shown to increase the sensitivity and lower the limit of detection for DA compared to bare CFEs. Thicker PEDOT/GO coatings demonstrate higher sensitivities for DA, but display the negative drawback of slow adsorption and electron transfer kinetics. The moderate thickness resulting from 25 s electrodeposition of PEDOT/GO produces the optimal electrode, exhibiting an 880% increase in sensitivity, a 50% decrease in limit of detection and minimally altered electrode kinetics. PEDOT/GO coated electrodes rapidly and robustly detect DA, both in solution and in the rat dorsal striatum. This increase in DA sensitivity is likely due to increasing the electrode surface area with a PEDOT/GO coating and improved adsorption of DA's oxidation product (DA-o-quinone). Increasing DA sensitivity without compromising electrode kinetics is expected to significantly improve our understanding of the DA function in vivo.
•We developed a PEDOT/GO coated carbon fiber microelectrode for in vivo use.•Electrodes exhibit 880% sensitivity increase for dopamine versus bare carbon fiber.•PEDOT/GO electrodes successfully detected electrically stimulated dopamine in vivo.</abstract><cop>England</cop><pub>Elsevier B.V</pub><pmid>27268013</pmid><doi>10.1016/j.bios.2016.05.084</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0956-5663 |
ispartof | Biosensors & bioelectronics, 2017-03, Vol.89 (Pt 1), p.400-410 |
issn | 0956-5663 1873-4235 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5107160 |
source | MEDLINE; Access via ScienceDirect (Elsevier) |
subjects | Animals Biosensing Techniques - methods Bridged Bicyclo Compounds, Heterocyclic - chemistry Carbon fiber Carbon fibers Coatings Corpus Striatum - chemistry Dopamine Dopamine - analysis Electrochemical Techniques - methods Electrodeposition Electrodes Electroplating FSCV Graphene Graphene oxide Graphite - chemistry Limit of Detection Male Microelectrodes PEDOT Polymers - chemistry Rats Rats, Sprague-Dawley Sensitivity Surface chemistry |
title | Enhanced dopamine detection sensitivity by PEDOT/graphene oxide coating on in vivo carbon fiber electrodes |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-18T13%3A50%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Enhanced%20dopamine%20detection%20sensitivity%20by%20PEDOT/graphene%20oxide%20coating%20on%20in%20vivo%20carbon%20fiber%20electrodes&rft.jtitle=Biosensors%20&%20bioelectronics&rft.au=Taylor,%20I.%20Mitch&rft.date=2017-03-15&rft.volume=89&rft.issue=Pt%201&rft.spage=400&rft.epage=410&rft.pages=400-410&rft.issn=0956-5663&rft.eissn=1873-4235&rft_id=info:doi/10.1016/j.bios.2016.05.084&rft_dat=%3Cproquest_pubme%3E1826691296%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1826691296&rft_id=info:pmid/27268013&rft_els_id=S0956566316305140&rfr_iscdi=true |