Differentiation of squamous cell carcinoma and inverted papilloma using non-invasive MR perfusion imaging

To investigate the diagnostic value of tumour blood flow (TBF) obtained with pseudocontinuous arterial spin labelling for the differentiation of squamous cell carcinoma (SCC) and inverted papilloma (IP) in the nasal or sinonasal cavity. We retrospectively analysed the cases of 33 patients with SCC a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Dento-maxillo-facial radiology 2015, Vol.44 (9), p.20150074
Hauptverfasser: Fujima, N, Nakamaru, Y, Sakashita, T, Homma, A, Tsukahara, A, Kudo, K, Shirato, H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To investigate the diagnostic value of tumour blood flow (TBF) obtained with pseudocontinuous arterial spin labelling for the differentiation of squamous cell carcinoma (SCC) and inverted papilloma (IP) in the nasal or sinonasal cavity. We retrospectively analysed the cases of 33 patients with SCC and 8 patients with IP in the nasal or sinonasal cavity. Pseudocontinuous arterial spin labelling scanning was performed for all patients using a 3.0-T MR unit. Quantitative TBF values were measured by two neuroradiologists by respectively delineating the whole-tumour regions of interest, and the mean of them was determined as TBF value in each patient. Additionally, the presence of imaging findings of convoluted cerebriform pattern (CCP) on MR T2 weighted images was determined in all patients. As a subgroup analysis, patients with IP were divided into aggressive and non-aggressive IPs depending on their progression range. First, an intraclass correlation coefficient (ICC) of TBF values between two neuroradiologists was determined. Next, a statistical comparison of the TBF value by a Mann-Whitney U test between the patients with SCC and IP was performed. Additionally, the comparison by an ANOVA with a post hoc test of Tukey's method among the SCC, non-aggressive IP and aggressive IP groups was also performed. If significance was observed, the diagnostic accuracy to differentiate SCCs from IPs was calculated. Diagnostic accuracy by CCP findings alone and by the combination of CCP findings and TBF were also assessed. The ICC of TBF values between two neuroradiologists was 0.82. The mean TBF values in the patients with SCC, all patients with IP, those with aggressive IP and those with non-aggressive IP were 141.2 ± 33.1, 77.8 ± 31.5, 109.4 ± 16.7 and 58.8 ± 19.9 ml 100 g⁻¹ min⁻¹, respectively. A significant difference was observed between SCC and IP (p 
ISSN:0250-832X
1476-542X