Evaluation of Semiautomated IS6110-Based Restriction Fragment Length Polymorphism Typing for Mycobacterium tuberculosis in a High-Burden Setting

The manual IS6110-based restriction fragment length polymorphism (RFLP) typing method is highly discriminatory; however, it is laborious and technically demanding, and data exchange remains a challenge. In an effort to improve IS6110-based RFLP to make it a faster format, DuPont Molecular Diagnostic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical microbiology 2016-10, Vol.54 (10), p.2547-2552
Hauptverfasser: Said, Halima M, Krishnamani, Keshav, Omar, Shaheed V, Dreyer, Andries W, Sansom, Bianca, Fallows, Dorothy, Ismail, Nazir A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The manual IS6110-based restriction fragment length polymorphism (RFLP) typing method is highly discriminatory; however, it is laborious and technically demanding, and data exchange remains a challenge. In an effort to improve IS6110-based RFLP to make it a faster format, DuPont Molecular Diagnostics recently introduced the IS6110-PvuII kit for semiautomated typing of Mycobacterium tuberculosis using the RiboPrinter microbial characterization system. This study aimed to evaluate the semiautomated RFLP typing against the standard manual method. A total of 112 isolates collected between 2013 and 2014 were included. All isolates were genotyped using manual and semiautomated RFLP typing methods. Clustering rates and discriminatory indexes were compared between methods. The overall performance of semiautomated RFLP compared to manual typing was excellent, with high discriminatory index (0.990 versus 0.995, respectively) and similar numbers of unique profiles (72 versus 74, respectively), numbers of clustered isolates (33 versus 31, respectively), cluster sizes (2 to 6 and 2 to 5 isolates, respectively), and clustering rates (21.9% and 17.1%, respectively). The semiautomated RFLP system is technically simple and significantly faster than the manual RFLP method (8 h versus 5 days). The analysis is fully automated and generates easily manageable databases of standardized fingerprints that can be easily exchanged between laboratories. Based on its high-throughput processing with minimal human effort, the semiautomated RFLP can be a very useful tool as a first-line method for routine typing of M. tuberculosis isolates, especially where Beijing strains are highly prevalent, followed by manual RFLP typing if resolution is not achieved, thereby saving time and labor.
ISSN:0095-1137
1098-660X
DOI:10.1128/JCM.00408-16