Transcutaneous PCO2 Monitoring in Newborn Infants During General Anesthesia Is Technically Feasible
BACKGROUND:Transcutaneous (TC) measurement of PCO2 (TC PCO2) is a well-established method to monitor assisted ventilation in neonatal intensive care, but its use in the operating room is limited, and the data regarding its performance during general anesthesia of the newborn are lacking. The aim of...
Gespeichert in:
Veröffentlicht in: | Anesthesia and analgesia 2016-10, Vol.123 (4), p.1004-1007 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1007 |
---|---|
container_issue | 4 |
container_start_page | 1004 |
container_title | Anesthesia and analgesia |
container_volume | 123 |
creator | Karlsson, Victoria Sporre, Bengt Ågren, Johan |
description | BACKGROUND:Transcutaneous (TC) measurement of PCO2 (TC PCO2) is a well-established method to monitor assisted ventilation in neonatal intensive care, but its use in the operating room is limited, and the data regarding its performance during general anesthesia of the newborn are lacking. The aim of this study is to evaluate the performance of continuous TC PCO2 monitoring during general anesthesia in newborn infants.
METHODS:Infants (n = 25) with a gestational age of 23 to 41 weeks and a birth weight of 548 to 4114 g were prospectively enrolled. During general anesthesia and surgery, TC PCO2 was measured continuously and recorded at 1-minute intervals. Five-minute mean values were compared with simultaneously obtained blood gas (BG) analyses of PCO2. Only the first paired TC and BG samples were used in this analysis. We defined precision as 2.1 times the standard deviation of the difference of the 2 samples. P < .01 was considered statistically significant.
RESULTS:We obtained samples from 25 infants. The difference between TC and BG was 0.3 ± 0.7 kPa (mean ± standard deviation) giving a precision of 1.47 kPa. Nineteen of twenty-five (76%) sample pairs displayed a difference of |
doi_str_mv | 10.1213/ANE.0000000000001462 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5017270</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1820594195</sourcerecordid><originalsourceid>FETCH-LOGICAL-p1602-4ff1866b1e9d150439cee52f176b9e67bb19bb731342cc688df0ec94645e59253</originalsourceid><addsrcrecordid>eNpdUctO6zAQtdBFUB5_gJCXdxOwndiJN1eqyqsSr0VZW7Y7IQbX6bUTKv6elAICZjPSnKNzZuYgdETJCWU0Px3fnp-Qb0ULwbbQiHImspLL6g8aDdM8Y1LKXbSX0tOaRCqxg3ZZWYhClmKE7CzqkGzf6QBtn_D95I7hmza4ro0uPGIX8C2sTBsDnoZahy7hs_4duYQAUXs8DpC6BpLTeJrwDGwTnNXev-IL0MkZDwdou9Y-weFH30cPF-ezyVV2fXc5nYyvsyUVhGVFXdNKCENBziknRS4tAGc1LYWRIEpjqDSmzGleMGtFVc1rAlYOl3DgkvF8H_3b6C57s4C5hdANC6pldAsdX1WrnfqJBNeox_ZFcUJLVpJB4O-HQGz_98NZauGSBe83z1G0YoTLgsq11_F3ry-Tz88OhGpDWLW-g5iefb-CqBrQvmsUJWodohpCVL9DzN8AihmN7Q</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1820594195</pqid></control><display><type>article</type><title>Transcutaneous PCO2 Monitoring in Newborn Infants During General Anesthesia Is Technically Feasible</title><source>MEDLINE</source><source>Journals@Ovid LWW Legacy Archive</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Karlsson, Victoria ; Sporre, Bengt ; Ågren, Johan</creator><creatorcontrib>Karlsson, Victoria ; Sporre, Bengt ; Ågren, Johan</creatorcontrib><description>BACKGROUND:Transcutaneous (TC) measurement of PCO2 (TC PCO2) is a well-established method to monitor assisted ventilation in neonatal intensive care, but its use in the operating room is limited, and the data regarding its performance during general anesthesia of the newborn are lacking. The aim of this study is to evaluate the performance of continuous TC PCO2 monitoring during general anesthesia in newborn infants.
METHODS:Infants (n = 25) with a gestational age of 23 to 41 weeks and a birth weight of 548 to 4114 g were prospectively enrolled. During general anesthesia and surgery, TC PCO2 was measured continuously and recorded at 1-minute intervals. Five-minute mean values were compared with simultaneously obtained blood gas (BG) analyses of PCO2. Only the first paired TC and BG samples were used in this analysis. We defined precision as 2.1 times the standard deviation of the difference of the 2 samples. P < .01 was considered statistically significant.
RESULTS:We obtained samples from 25 infants. The difference between TC and BG was 0.3 ± 0.7 kPa (mean ± standard deviation) giving a precision of 1.47 kPa. Nineteen of twenty-five (76%) sample pairs displayed a difference of <1 kPa (99% confidence interval, 48%–92%, P = .016). The difference in paired samples was similar for different gestational and postnatal ages and did not appear to be affected by electrocautery.
CONCLUSIONS:In this small study, we did not demonstrate that TC CO2 monitoring was accurate at P < .01. This partly reflects the small size of the study, resulting in wide 99% confidence bounds.</description><identifier>ISSN: 0003-2999</identifier><identifier>EISSN: 1526-7598</identifier><identifier>DOI: 10.1213/ANE.0000000000001462</identifier><identifier>PMID: 27464976</identifier><language>eng</language><publisher>United States: International Anesthesia Research Society</publisher><subject>Anesthesia, General - methods ; Blood Gas Monitoring, Transcutaneous - methods ; Female ; Gestational Age ; Humans ; Infant, Newborn ; Intensive Care, Neonatal - methods ; Male ; Monitoring, Intraoperative - methods ; Original Clinical Research Report ; Pediatric Anesthesiology ; Prospective Studies</subject><ispartof>Anesthesia and analgesia, 2016-10, Vol.123 (4), p.1004-1007</ispartof><rights>2016 International Anesthesia Research Society</rights><rights>Copyright © 2016 International Anesthesia Research Society. 2016</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27464976$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Karlsson, Victoria</creatorcontrib><creatorcontrib>Sporre, Bengt</creatorcontrib><creatorcontrib>Ågren, Johan</creatorcontrib><title>Transcutaneous PCO2 Monitoring in Newborn Infants During General Anesthesia Is Technically Feasible</title><title>Anesthesia and analgesia</title><addtitle>Anesth Analg</addtitle><description>BACKGROUND:Transcutaneous (TC) measurement of PCO2 (TC PCO2) is a well-established method to monitor assisted ventilation in neonatal intensive care, but its use in the operating room is limited, and the data regarding its performance during general anesthesia of the newborn are lacking. The aim of this study is to evaluate the performance of continuous TC PCO2 monitoring during general anesthesia in newborn infants.
METHODS:Infants (n = 25) with a gestational age of 23 to 41 weeks and a birth weight of 548 to 4114 g were prospectively enrolled. During general anesthesia and surgery, TC PCO2 was measured continuously and recorded at 1-minute intervals. Five-minute mean values were compared with simultaneously obtained blood gas (BG) analyses of PCO2. Only the first paired TC and BG samples were used in this analysis. We defined precision as 2.1 times the standard deviation of the difference of the 2 samples. P < .01 was considered statistically significant.
RESULTS:We obtained samples from 25 infants. The difference between TC and BG was 0.3 ± 0.7 kPa (mean ± standard deviation) giving a precision of 1.47 kPa. Nineteen of twenty-five (76%) sample pairs displayed a difference of <1 kPa (99% confidence interval, 48%–92%, P = .016). The difference in paired samples was similar for different gestational and postnatal ages and did not appear to be affected by electrocautery.
CONCLUSIONS:In this small study, we did not demonstrate that TC CO2 monitoring was accurate at P < .01. This partly reflects the small size of the study, resulting in wide 99% confidence bounds.</description><subject>Anesthesia, General - methods</subject><subject>Blood Gas Monitoring, Transcutaneous - methods</subject><subject>Female</subject><subject>Gestational Age</subject><subject>Humans</subject><subject>Infant, Newborn</subject><subject>Intensive Care, Neonatal - methods</subject><subject>Male</subject><subject>Monitoring, Intraoperative - methods</subject><subject>Original Clinical Research Report</subject><subject>Pediatric Anesthesiology</subject><subject>Prospective Studies</subject><issn>0003-2999</issn><issn>1526-7598</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdUctO6zAQtdBFUB5_gJCXdxOwndiJN1eqyqsSr0VZW7Y7IQbX6bUTKv6elAICZjPSnKNzZuYgdETJCWU0Px3fnp-Qb0ULwbbQiHImspLL6g8aDdM8Y1LKXbSX0tOaRCqxg3ZZWYhClmKE7CzqkGzf6QBtn_D95I7hmza4ro0uPGIX8C2sTBsDnoZahy7hs_4duYQAUXs8DpC6BpLTeJrwDGwTnNXev-IL0MkZDwdou9Y-weFH30cPF-ezyVV2fXc5nYyvsyUVhGVFXdNKCENBziknRS4tAGc1LYWRIEpjqDSmzGleMGtFVc1rAlYOl3DgkvF8H_3b6C57s4C5hdANC6pldAsdX1WrnfqJBNeox_ZFcUJLVpJB4O-HQGz_98NZauGSBe83z1G0YoTLgsq11_F3ry-Tz88OhGpDWLW-g5iefb-CqBrQvmsUJWodohpCVL9DzN8AihmN7Q</recordid><startdate>201610</startdate><enddate>201610</enddate><creator>Karlsson, Victoria</creator><creator>Sporre, Bengt</creator><creator>Ågren, Johan</creator><general>International Anesthesia Research Society</general><general>Lippincott Williams & Wilkins</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>201610</creationdate><title>Transcutaneous PCO2 Monitoring in Newborn Infants During General Anesthesia Is Technically Feasible</title><author>Karlsson, Victoria ; Sporre, Bengt ; Ågren, Johan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p1602-4ff1866b1e9d150439cee52f176b9e67bb19bb731342cc688df0ec94645e59253</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Anesthesia, General - methods</topic><topic>Blood Gas Monitoring, Transcutaneous - methods</topic><topic>Female</topic><topic>Gestational Age</topic><topic>Humans</topic><topic>Infant, Newborn</topic><topic>Intensive Care, Neonatal - methods</topic><topic>Male</topic><topic>Monitoring, Intraoperative - methods</topic><topic>Original Clinical Research Report</topic><topic>Pediatric Anesthesiology</topic><topic>Prospective Studies</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Karlsson, Victoria</creatorcontrib><creatorcontrib>Sporre, Bengt</creatorcontrib><creatorcontrib>Ågren, Johan</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Anesthesia and analgesia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Karlsson, Victoria</au><au>Sporre, Bengt</au><au>Ågren, Johan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Transcutaneous PCO2 Monitoring in Newborn Infants During General Anesthesia Is Technically Feasible</atitle><jtitle>Anesthesia and analgesia</jtitle><addtitle>Anesth Analg</addtitle><date>2016-10</date><risdate>2016</risdate><volume>123</volume><issue>4</issue><spage>1004</spage><epage>1007</epage><pages>1004-1007</pages><issn>0003-2999</issn><eissn>1526-7598</eissn><abstract>BACKGROUND:Transcutaneous (TC) measurement of PCO2 (TC PCO2) is a well-established method to monitor assisted ventilation in neonatal intensive care, but its use in the operating room is limited, and the data regarding its performance during general anesthesia of the newborn are lacking. The aim of this study is to evaluate the performance of continuous TC PCO2 monitoring during general anesthesia in newborn infants.
METHODS:Infants (n = 25) with a gestational age of 23 to 41 weeks and a birth weight of 548 to 4114 g were prospectively enrolled. During general anesthesia and surgery, TC PCO2 was measured continuously and recorded at 1-minute intervals. Five-minute mean values were compared with simultaneously obtained blood gas (BG) analyses of PCO2. Only the first paired TC and BG samples were used in this analysis. We defined precision as 2.1 times the standard deviation of the difference of the 2 samples. P < .01 was considered statistically significant.
RESULTS:We obtained samples from 25 infants. The difference between TC and BG was 0.3 ± 0.7 kPa (mean ± standard deviation) giving a precision of 1.47 kPa. Nineteen of twenty-five (76%) sample pairs displayed a difference of <1 kPa (99% confidence interval, 48%–92%, P = .016). The difference in paired samples was similar for different gestational and postnatal ages and did not appear to be affected by electrocautery.
CONCLUSIONS:In this small study, we did not demonstrate that TC CO2 monitoring was accurate at P < .01. This partly reflects the small size of the study, resulting in wide 99% confidence bounds.</abstract><cop>United States</cop><pub>International Anesthesia Research Society</pub><pmid>27464976</pmid><doi>10.1213/ANE.0000000000001462</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2999 |
ispartof | Anesthesia and analgesia, 2016-10, Vol.123 (4), p.1004-1007 |
issn | 0003-2999 1526-7598 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5017270 |
source | MEDLINE; Journals@Ovid LWW Legacy Archive; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals |
subjects | Anesthesia, General - methods Blood Gas Monitoring, Transcutaneous - methods Female Gestational Age Humans Infant, Newborn Intensive Care, Neonatal - methods Male Monitoring, Intraoperative - methods Original Clinical Research Report Pediatric Anesthesiology Prospective Studies |
title | Transcutaneous PCO2 Monitoring in Newborn Infants During General Anesthesia Is Technically Feasible |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T10%3A10%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Transcutaneous%20PCO2%20Monitoring%20in%20Newborn%20Infants%20During%20General%20Anesthesia%20Is%20Technically%20Feasible&rft.jtitle=Anesthesia%20and%20analgesia&rft.au=Karlsson,%20Victoria&rft.date=2016-10&rft.volume=123&rft.issue=4&rft.spage=1004&rft.epage=1007&rft.pages=1004-1007&rft.issn=0003-2999&rft.eissn=1526-7598&rft_id=info:doi/10.1213/ANE.0000000000001462&rft_dat=%3Cproquest_pubme%3E1820594195%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1820594195&rft_id=info:pmid/27464976&rfr_iscdi=true |