Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects
This study aimed to compare the diagnostic accuracy of inverted and unprocessed digitized periapical radiographs for detection of peri-implant defects. A total of 30 osteotomy sites were prepared in three groups of control, study group 1 with 0.425 mm defects and study group 2 with 0.725 mm defects...
Gespeichert in:
Veröffentlicht in: | Journal of dentistry (Tehran, Iran) Iran), 2015-08, Vol.12 (8), p.571-576 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 576 |
---|---|
container_issue | 8 |
container_start_page | 571 |
container_title | Journal of dentistry (Tehran, Iran) |
container_volume | 12 |
creator | Pourhashemi, Seyed Jalal Ghoncheh, Zahra Kiani, Mohammad Taghi Emami, Raheleh Kharazifard, Mohamad Javad |
description | This study aimed to compare the diagnostic accuracy of inverted and unprocessed digitized periapical radiographs for detection of peri-implant defects.
A total of 30 osteotomy sites were prepared in three groups of control, study group 1 with 0.425 mm defects and study group 2 with 0.725 mm defects using the SIC and Astra Tech drill systems with 4.25mm and 4.85mm diameters. Small and large defects were randomly created in the coronal 8mm of 20 implant sites; implants (3.4mm diameter, 14.5mm length) were then placed. Thirty periapical (PA) radiographs were obtained using Digora imaging system (Soredex Corporation, Helsinki, Finland), size 2 photostimulable storage phosphor (PSP) plate sensors (40.0mm×30.0mm) and Scanora software. Unprocessed images were inverted using Scanora software by applying image inversion and a total of 60 images were obtained and randomly evaluated by four oral and maxillofacial radiologists. Data were analyzed using the t-test.
Significant differences were observed in absolute and complete sensitivity and specificity of the two imaging modalities for detection of small and large defects (P |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4847162</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1785730545</sourcerecordid><originalsourceid>FETCH-LOGICAL-p1112-c6ac1422a51540a7d411362f641930e466519d98da5432f7d7c500745e9c6dd83</originalsourceid><addsrcrecordid>eNpVkFtLw0AQhYMotlb_guTRl8DeN3kRSuulUFDEPodxd5OuJNm4uynUX2-KVfRpznAO32HmJJkShPKM4JyfJlMsKR81R5PkIoR3hLgoJD9PJkRiQhEW02S3tFB3LkSr0rlSgwe1T12Vrrqd8dHoFDqdbrreO2VCGPelrW20n6N6Nt5CbxU06Qto62oP_TaklfPp0kSjonXdAXXIZau2b6CLo1ONTrhMzipogrk6zlmyub97XTxm66eH1WK-znqMMcmUAIUZIcAxZwikZhhTQSrBcEGRYUJwXOgi18AZJZXUUnGEJOOmUELrnM6S229uP7y1RivTRQ9N2Xvbgt-XDmz53-nstqzdrmQ5k1iQEXBzBHj3MZgQy9YGZZrxGOOGUGKZc0kRZ3yMXv_t-i35eTb9AmxRfX0</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1785730545</pqid></control><display><type>article</type><title>Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects</title><source>PubMed Central Open Access</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Pourhashemi, Seyed Jalal ; Ghoncheh, Zahra ; Kiani, Mohammad Taghi ; Emami, Raheleh ; Kharazifard, Mohamad Javad</creator><creatorcontrib>Pourhashemi, Seyed Jalal ; Ghoncheh, Zahra ; Kiani, Mohammad Taghi ; Emami, Raheleh ; Kharazifard, Mohamad Javad</creatorcontrib><description>This study aimed to compare the diagnostic accuracy of inverted and unprocessed digitized periapical radiographs for detection of peri-implant defects.
A total of 30 osteotomy sites were prepared in three groups of control, study group 1 with 0.425 mm defects and study group 2 with 0.725 mm defects using the SIC and Astra Tech drill systems with 4.25mm and 4.85mm diameters. Small and large defects were randomly created in the coronal 8mm of 20 implant sites; implants (3.4mm diameter, 14.5mm length) were then placed. Thirty periapical (PA) radiographs were obtained using Digora imaging system (Soredex Corporation, Helsinki, Finland), size 2 photostimulable storage phosphor (PSP) plate sensors (40.0mm×30.0mm) and Scanora software. Unprocessed images were inverted using Scanora software by applying image inversion and a total of 60 images were obtained and randomly evaluated by four oral and maxillofacial radiologists. Data were analyzed using the t-test.
Significant differences were observed in absolute and complete sensitivity and specificity of the two imaging modalities for detection of small and large defects (P<0.05). Unprocessed digital images had a higher mean in terms of absolute sensitivity for detection of small defects, complete sensitivity for detection of large peri-implant defects and definite rule out of defects compared with inverted images.
Unprocessed digital images have a higher diagnostic value for detection of small and large peri-implant defects and also for definite rule out of defects compared with inverted images.</description><identifier>ISSN: 1735-2150</identifier><identifier>EISSN: 2008-2185</identifier><identifier>PMID: 27123016</identifier><language>eng</language><publisher>Iran: Tehran University of Medical Sciences</publisher><subject>Original</subject><ispartof>Journal of dentistry (Tehran, Iran), 2015-08, Vol.12 (8), p.571-576</ispartof><rights>Copyright© Dental Research Center, Tehran University of Medical Sciences 2015</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4847162/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4847162/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,315,729,782,786,887,53798,53800</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27123016$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Pourhashemi, Seyed Jalal</creatorcontrib><creatorcontrib>Ghoncheh, Zahra</creatorcontrib><creatorcontrib>Kiani, Mohammad Taghi</creatorcontrib><creatorcontrib>Emami, Raheleh</creatorcontrib><creatorcontrib>Kharazifard, Mohamad Javad</creatorcontrib><title>Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects</title><title>Journal of dentistry (Tehran, Iran)</title><addtitle>J Dent (Tehran)</addtitle><description>This study aimed to compare the diagnostic accuracy of inverted and unprocessed digitized periapical radiographs for detection of peri-implant defects.
A total of 30 osteotomy sites were prepared in three groups of control, study group 1 with 0.425 mm defects and study group 2 with 0.725 mm defects using the SIC and Astra Tech drill systems with 4.25mm and 4.85mm diameters. Small and large defects were randomly created in the coronal 8mm of 20 implant sites; implants (3.4mm diameter, 14.5mm length) were then placed. Thirty periapical (PA) radiographs were obtained using Digora imaging system (Soredex Corporation, Helsinki, Finland), size 2 photostimulable storage phosphor (PSP) plate sensors (40.0mm×30.0mm) and Scanora software. Unprocessed images were inverted using Scanora software by applying image inversion and a total of 60 images were obtained and randomly evaluated by four oral and maxillofacial radiologists. Data were analyzed using the t-test.
Significant differences were observed in absolute and complete sensitivity and specificity of the two imaging modalities for detection of small and large defects (P<0.05). Unprocessed digital images had a higher mean in terms of absolute sensitivity for detection of small defects, complete sensitivity for detection of large peri-implant defects and definite rule out of defects compared with inverted images.
Unprocessed digital images have a higher diagnostic value for detection of small and large peri-implant defects and also for definite rule out of defects compared with inverted images.</description><subject>Original</subject><issn>1735-2150</issn><issn>2008-2185</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNpVkFtLw0AQhYMotlb_guTRl8DeN3kRSuulUFDEPodxd5OuJNm4uynUX2-KVfRpznAO32HmJJkShPKM4JyfJlMsKR81R5PkIoR3hLgoJD9PJkRiQhEW02S3tFB3LkSr0rlSgwe1T12Vrrqd8dHoFDqdbrreO2VCGPelrW20n6N6Nt5CbxU06Qto62oP_TaklfPp0kSjonXdAXXIZau2b6CLo1ONTrhMzipogrk6zlmyub97XTxm66eH1WK-znqMMcmUAIUZIcAxZwikZhhTQSrBcEGRYUJwXOgi18AZJZXUUnGEJOOmUELrnM6S229uP7y1RivTRQ9N2Xvbgt-XDmz53-nstqzdrmQ5k1iQEXBzBHj3MZgQy9YGZZrxGOOGUGKZc0kRZ3yMXv_t-i35eTb9AmxRfX0</recordid><startdate>201508</startdate><enddate>201508</enddate><creator>Pourhashemi, Seyed Jalal</creator><creator>Ghoncheh, Zahra</creator><creator>Kiani, Mohammad Taghi</creator><creator>Emami, Raheleh</creator><creator>Kharazifard, Mohamad Javad</creator><general>Tehran University of Medical Sciences</general><scope>NPM</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>201508</creationdate><title>Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects</title><author>Pourhashemi, Seyed Jalal ; Ghoncheh, Zahra ; Kiani, Mohammad Taghi ; Emami, Raheleh ; Kharazifard, Mohamad Javad</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p1112-c6ac1422a51540a7d411362f641930e466519d98da5432f7d7c500745e9c6dd83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Original</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pourhashemi, Seyed Jalal</creatorcontrib><creatorcontrib>Ghoncheh, Zahra</creatorcontrib><creatorcontrib>Kiani, Mohammad Taghi</creatorcontrib><creatorcontrib>Emami, Raheleh</creatorcontrib><creatorcontrib>Kharazifard, Mohamad Javad</creatorcontrib><collection>PubMed</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of dentistry (Tehran, Iran)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pourhashemi, Seyed Jalal</au><au>Ghoncheh, Zahra</au><au>Kiani, Mohammad Taghi</au><au>Emami, Raheleh</au><au>Kharazifard, Mohamad Javad</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects</atitle><jtitle>Journal of dentistry (Tehran, Iran)</jtitle><addtitle>J Dent (Tehran)</addtitle><date>2015-08</date><risdate>2015</risdate><volume>12</volume><issue>8</issue><spage>571</spage><epage>576</epage><pages>571-576</pages><issn>1735-2150</issn><eissn>2008-2185</eissn><abstract>This study aimed to compare the diagnostic accuracy of inverted and unprocessed digitized periapical radiographs for detection of peri-implant defects.
A total of 30 osteotomy sites were prepared in three groups of control, study group 1 with 0.425 mm defects and study group 2 with 0.725 mm defects using the SIC and Astra Tech drill systems with 4.25mm and 4.85mm diameters. Small and large defects were randomly created in the coronal 8mm of 20 implant sites; implants (3.4mm diameter, 14.5mm length) were then placed. Thirty periapical (PA) radiographs were obtained using Digora imaging system (Soredex Corporation, Helsinki, Finland), size 2 photostimulable storage phosphor (PSP) plate sensors (40.0mm×30.0mm) and Scanora software. Unprocessed images were inverted using Scanora software by applying image inversion and a total of 60 images were obtained and randomly evaluated by four oral and maxillofacial radiologists. Data were analyzed using the t-test.
Significant differences were observed in absolute and complete sensitivity and specificity of the two imaging modalities for detection of small and large defects (P<0.05). Unprocessed digital images had a higher mean in terms of absolute sensitivity for detection of small defects, complete sensitivity for detection of large peri-implant defects and definite rule out of defects compared with inverted images.
Unprocessed digital images have a higher diagnostic value for detection of small and large peri-implant defects and also for definite rule out of defects compared with inverted images.</abstract><cop>Iran</cop><pub>Tehran University of Medical Sciences</pub><pmid>27123016</pmid><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1735-2150 |
ispartof | Journal of dentistry (Tehran, Iran), 2015-08, Vol.12 (8), p.571-576 |
issn | 1735-2150 2008-2185 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4847162 |
source | PubMed Central Open Access; PubMed Central; Alma/SFX Local Collection |
subjects | Original |
title | Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T19%3A54%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Diagnostic%20Accuracy%20of%20Inverted%20and%20Unprocessed%20Digitized%20Periapical%20Radiographs%20for%20Detection%20of%20Peri-Implant%20Defects&rft.jtitle=Journal%20of%20dentistry%20(Tehran,%20Iran)&rft.au=Pourhashemi,%20Seyed%20Jalal&rft.date=2015-08&rft.volume=12&rft.issue=8&rft.spage=571&rft.epage=576&rft.pages=571-576&rft.issn=1735-2150&rft.eissn=2008-2185&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E1785730545%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1785730545&rft_id=info:pmid/27123016&rfr_iscdi=true |