A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication
ABSTRACT The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, a...
Gespeichert in:
Veröffentlicht in: | European journal of dentistry 2016-04, Vol.10 (2), p.286-291 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 291 |
---|---|
container_issue | 2 |
container_start_page | 286 |
container_title | European journal of dentistry |
container_volume | 10 |
creator | Bilgin, Mehmet Selim Baytaroğlu, Ebru Nur Erdem, Ali Dilber, Erhan |
description | ABSTRACT
The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now. |
doi_str_mv | 10.4103/1305-7456.178304 |
format | Article |
fullrecord | <record><control><sourceid>gale_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4813451</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A446903065</galeid><sourcerecordid>A446903065</sourcerecordid><originalsourceid>FETCH-LOGICAL-c586r-e648c9091e95a48761b1f0329a69d1d73dfe27655285a1a3a358c7647be0e8163</originalsourceid><addsrcrecordid>eNp1ks9v0zAUxyMEYmNw54QiIU1c0trxj8QXpGraAGmCC5wtx3luvSV2sZNW_Pc4pKtaBPLB1vPn-9Xz8zfL3mK0oBiRJSaIFRVlfIGrmiD6LLs8lDh9fjwzfpG9ivEBIU64EC-zi7JCgglcXmZ2lQfYWdjn3uTa99txgFAo20KbtxDt2i3_qvbKjUbpYQyQD6A3zv4cIebGh-TU-51qOkhS9wcwqglWq8F69zp7YVQX4c1hv8p-3N1-v_lc3H_79OVmdV9oVvNQAKe1FkhgEEzRuuK4wQaRUiguWtxWpDVQVpyxsmYKK6IIq3XFadUAghpzcpV9nH23Y9NDq1MnQXVyG2yvwi_plZXnN85u5NrvJK0xoQwngw8Hg-Cnpw2yt1FD1ykHfoxyGjUhglKW0PczulYdSOuMT456wuWKUi4QQXyiFv-g0mqht9o7MDbVzwTXJ4INqG7YRN-N0xjjOYhmUAcfYwBzfCZGckqInCIgpwjIOSFJ8u50PEfBUyQS8HUG9r5Lvx4fu3EPQSb20fn9mXFxYizLmsuVnMMkvZFPsUmGy9lw2FjoQT74MbiUgP_3-BtBrd5n</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1783339445</pqid></control><display><type>article</type><title>A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication</title><source>Thieme Connect Journals Open Access</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>Bilgin, Mehmet Selim ; Baytaroğlu, Ebru Nur ; Erdem, Ali ; Dilber, Erhan</creator><creatorcontrib>Bilgin, Mehmet Selim ; Baytaroğlu, Ebru Nur ; Erdem, Ali ; Dilber, Erhan</creatorcontrib><description>ABSTRACT
The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now.</description><identifier>ISSN: 1305-7456</identifier><identifier>EISSN: 1305-7464</identifier><identifier>DOI: 10.4103/1305-7456.178304</identifier><identifier>PMID: 27095912</identifier><language>eng</language><publisher>A-12, Second Floor, Sector -2, NOIDA -201301, India: Thieme Medical and Scientific Publishers Private Ltd</publisher><subject>Dental technology ; Dentures ; Design and construction ; Innovations ; Medical computer applications ; Review ; Review Article</subject><ispartof>European journal of dentistry, 2016-04, Vol.10 (2), p.286-291</ispartof><rights>COPYRIGHT 2016 Medknow Publications and Media Pvt. Ltd.</rights><rights>Copyright: © European Journal of Dentistry 2016</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c586r-e648c9091e95a48761b1f0329a69d1d73dfe27655285a1a3a358c7647be0e8163</citedby><cites>FETCH-LOGICAL-c586r-e648c9091e95a48761b1f0329a69d1d73dfe27655285a1a3a358c7647be0e8163</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4813451/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4813451/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,20891,27924,27925,53791,53793,54587</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27095912$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bilgin, Mehmet Selim</creatorcontrib><creatorcontrib>Baytaroğlu, Ebru Nur</creatorcontrib><creatorcontrib>Erdem, Ali</creatorcontrib><creatorcontrib>Dilber, Erhan</creatorcontrib><title>A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication</title><title>European journal of dentistry</title><addtitle>Eur J Dent</addtitle><description>ABSTRACT
The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now.</description><subject>Dental technology</subject><subject>Dentures</subject><subject>Design and construction</subject><subject>Innovations</subject><subject>Medical computer applications</subject><subject>Review</subject><subject>Review Article</subject><issn>1305-7456</issn><issn>1305-7464</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>0U6</sourceid><recordid>eNp1ks9v0zAUxyMEYmNw54QiIU1c0trxj8QXpGraAGmCC5wtx3luvSV2sZNW_Pc4pKtaBPLB1vPn-9Xz8zfL3mK0oBiRJSaIFRVlfIGrmiD6LLs8lDh9fjwzfpG9ivEBIU64EC-zi7JCgglcXmZ2lQfYWdjn3uTa99txgFAo20KbtxDt2i3_qvbKjUbpYQyQD6A3zv4cIebGh-TU-51qOkhS9wcwqglWq8F69zp7YVQX4c1hv8p-3N1-v_lc3H_79OVmdV9oVvNQAKe1FkhgEEzRuuK4wQaRUiguWtxWpDVQVpyxsmYKK6IIq3XFadUAghpzcpV9nH23Y9NDq1MnQXVyG2yvwi_plZXnN85u5NrvJK0xoQwngw8Hg-Cnpw2yt1FD1ykHfoxyGjUhglKW0PczulYdSOuMT456wuWKUi4QQXyiFv-g0mqht9o7MDbVzwTXJ4INqG7YRN-N0xjjOYhmUAcfYwBzfCZGckqInCIgpwjIOSFJ8u50PEfBUyQS8HUG9r5Lvx4fu3EPQSb20fn9mXFxYizLmsuVnMMkvZFPsUmGy9lw2FjoQT74MbiUgP_3-BtBrd5n</recordid><startdate>20160401</startdate><enddate>20160401</enddate><creator>Bilgin, Mehmet Selim</creator><creator>Baytaroğlu, Ebru Nur</creator><creator>Erdem, Ali</creator><creator>Dilber, Erhan</creator><general>Thieme Medical and Scientific Publishers Private Ltd</general><general>Wolters Kluwer - Medknow Publications</general><general>Medknow Publications and Media Pvt. Ltd</general><general>Medknow Publications & Media Pvt Ltd</general><scope>0U6</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20160401</creationdate><title>A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication</title><author>Bilgin, Mehmet Selim ; Baytaroğlu, Ebru Nur ; Erdem, Ali ; Dilber, Erhan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c586r-e648c9091e95a48761b1f0329a69d1d73dfe27655285a1a3a358c7647be0e8163</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Dental technology</topic><topic>Dentures</topic><topic>Design and construction</topic><topic>Innovations</topic><topic>Medical computer applications</topic><topic>Review</topic><topic>Review Article</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bilgin, Mehmet Selim</creatorcontrib><creatorcontrib>Baytaroğlu, Ebru Nur</creatorcontrib><creatorcontrib>Erdem, Ali</creatorcontrib><creatorcontrib>Dilber, Erhan</creatorcontrib><collection>Thieme Connect Journals Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>European journal of dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bilgin, Mehmet Selim</au><au>Baytaroğlu, Ebru Nur</au><au>Erdem, Ali</au><au>Dilber, Erhan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication</atitle><jtitle>European journal of dentistry</jtitle><addtitle>Eur J Dent</addtitle><date>2016-04-01</date><risdate>2016</risdate><volume>10</volume><issue>2</issue><spage>286</spage><epage>291</epage><pages>286-291</pages><issn>1305-7456</issn><eissn>1305-7464</eissn><abstract>ABSTRACT
The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now.</abstract><cop>A-12, Second Floor, Sector -2, NOIDA -201301, India</cop><pub>Thieme Medical and Scientific Publishers Private Ltd</pub><pmid>27095912</pmid><doi>10.4103/1305-7456.178304</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1305-7456 |
ispartof | European journal of dentistry, 2016-04, Vol.10 (2), p.286-291 |
issn | 1305-7456 1305-7464 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4813451 |
source | Thieme Connect Journals Open Access; EZB-FREE-00999 freely available EZB journals; PubMed Central |
subjects | Dental technology Dentures Design and construction Innovations Medical computer applications Review Review Article |
title | A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T07%3A20%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20review%20of%20computer-aided%20design/computer-aided%20manufacture%20techniques%20for%20removable%20denture%20fabrication&rft.jtitle=European%20journal%20of%20dentistry&rft.au=Bilgin,%20Mehmet%20Selim&rft.date=2016-04-01&rft.volume=10&rft.issue=2&rft.spage=286&rft.epage=291&rft.pages=286-291&rft.issn=1305-7456&rft.eissn=1305-7464&rft_id=info:doi/10.4103/1305-7456.178304&rft_dat=%3Cgale_pubme%3EA446903065%3C/gale_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1783339445&rft_id=info:pmid/27095912&rft_galeid=A446903065&rfr_iscdi=true |