Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study
During a previously published study on gaseous microemboli (GMEs) and perfusionist interventions, it was noted that emboli could be detected after the arterial filter when blood/air challenges entered the membrane oxygenator's integral cardiotomy. The findings indicated that further study into...
Gespeichert in:
Veröffentlicht in: | The Journal of extra-corporeal technology 2009-03, Vol.41 (1), p.20-27 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 27 |
---|---|
container_issue | 1 |
container_start_page | 20 |
container_title | The Journal of extra-corporeal technology |
container_volume | 41 |
creator | Myers, Gerard J Voorhees, Cheri Haynes, Rob Eke, Bob |
description | During a previously published study on gaseous microemboli (GMEs) and perfusionist interventions, it was noted that emboli could be detected after the arterial filter when blood/air challenges entered the membrane oxygenator's integral cardiotomy. The findings indicated that further study into the oxygenator's integral cardiotomy reservoir was warranted. This is the first know published report that connects the vent return to GME activity after the arterial filter. To study the air handling ability of the membranes integral cardiotomy, an in vitro study was conducted on five hard shell coated membrane oxygenators (Terumo Capiox SX25, X coated; Sorin Synthesis, phosphorylcholine coated; Gish Vision, GBS coated; Medtronic Affinity NT, trillium coated; Maquet Quadrox, bioline coated). The oxygenators were matched with their own manufacturer's coated arterial filters (Medtronic 351T Arterial Filter, Sorin Synthesis Integrated Arterial Filter, Terumo CXAF200X Arterial Filter, Gish GAF40GBS-2 Arterial Filter, and Maquet Quart HBF140 Arterial Filter). There were three arms to the study, and three separate oxygenator/filter combinations were used in each arm. The first arm consisted of a pump flow of 4.0 L/min with only the filter purge blood entering the integral cardiotomy. In the second arm, 500 mL/min of simulated vent blood was added to the filter purge blood entering the integral cardiotomy. During the final arm, 200 mL/min of air was added to the vent blood as it entered the integral cardiotomy, to more closely simulate vent return during cardiopulmonary bypass. All GME activity in the oxygenator/filter combinations was examined using the Hatteland CMD20 Microemboli Counter. Placement of the Hatteland probes was 4 in after the hard shell reservoir outlet (PRO) and 12 in after the arterial filter (PAF). When vent blood flow was turned on, there was a significant increase in the PRO microemboli activity detected in all reservoirs. In the PAF position, three of the oxygenator/filter combinations were able to remove 98-99% of the GME, one removed 84.3%, and another removed only 55.5% of the GMEs coming out of the oxygenator's reservoir. All oxygenators were found to have a dramatic increase in reservoir GME activity when the vent was turned on. Depending on the oxygenator/filter combination, vent return into the oxygenator's integral cardiotomy resulted in the presence of significant amounts of GMEs after the arterial filter. |
doi_str_mv | 10.1051/ject/200941020 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4680219</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>67121366</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3690-c47e54ead9448bbf9cb08c05489002ad85c3dccbed1db3be847cb5697bb3329b3</originalsourceid><addsrcrecordid>eNpVUU1P3DAUtKoi2G659lj51FvAH4nX5lCpQlCQkOihPVv-eNkaJTHYTqTl1-MVK1pO70meGc-bQegLJWeUdPT8AVw5Z4SolhJGPqAVU0I1UgnyEa0IYaypMHmCPuX8QIighNNjdEIVryuTK_T8K-bSmFQgBTPgPgx1w1uTIc4Zj8GlCKONQ8DGlbCEssOxr7AFcJgKbFMlOZN8iCWOO5wgQ1piSBn7OYVpixeYSp0X2EyVgatCijiX2e8-o6PeDBlOD3ON_lxf_b68ae7uf95e_rhrHBeKNK7dQNeC8aptpbW9cpZIR7pWqnqf8bJz3DtnwVNvuQXZbpzthNpYyzlTlq_R91fdx9mO4F01VF3rxxRGk3Y6mqDfv0zhr97GRbdCElajWqNvB4EUn2bIRY8hOxgGM-1T0mJDGeVCVODZK7CmlnOC_u0TSvS-Lr2vS7_VVQlf_7f2D37oh78AIDCWOA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67121366</pqid></control><display><type>article</type><title>Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><creator>Myers, Gerard J ; Voorhees, Cheri ; Haynes, Rob ; Eke, Bob</creator><creatorcontrib>Myers, Gerard J ; Voorhees, Cheri ; Haynes, Rob ; Eke, Bob</creatorcontrib><description>During a previously published study on gaseous microemboli (GMEs) and perfusionist interventions, it was noted that emboli could be detected after the arterial filter when blood/air challenges entered the membrane oxygenator's integral cardiotomy. The findings indicated that further study into the oxygenator's integral cardiotomy reservoir was warranted. This is the first know published report that connects the vent return to GME activity after the arterial filter. To study the air handling ability of the membranes integral cardiotomy, an in vitro study was conducted on five hard shell coated membrane oxygenators (Terumo Capiox SX25, X coated; Sorin Synthesis, phosphorylcholine coated; Gish Vision, GBS coated; Medtronic Affinity NT, trillium coated; Maquet Quadrox, bioline coated). The oxygenators were matched with their own manufacturer's coated arterial filters (Medtronic 351T Arterial Filter, Sorin Synthesis Integrated Arterial Filter, Terumo CXAF200X Arterial Filter, Gish GAF40GBS-2 Arterial Filter, and Maquet Quart HBF140 Arterial Filter). There were three arms to the study, and three separate oxygenator/filter combinations were used in each arm. The first arm consisted of a pump flow of 4.0 L/min with only the filter purge blood entering the integral cardiotomy. In the second arm, 500 mL/min of simulated vent blood was added to the filter purge blood entering the integral cardiotomy. During the final arm, 200 mL/min of air was added to the vent blood as it entered the integral cardiotomy, to more closely simulate vent return during cardiopulmonary bypass. All GME activity in the oxygenator/filter combinations was examined using the Hatteland CMD20 Microemboli Counter. Placement of the Hatteland probes was 4 in after the hard shell reservoir outlet (PRO) and 12 in after the arterial filter (PAF). When vent blood flow was turned on, there was a significant increase in the PRO microemboli activity detected in all reservoirs. In the PAF position, three of the oxygenator/filter combinations were able to remove 98-99% of the GME, one removed 84.3%, and another removed only 55.5% of the GMEs coming out of the oxygenator's reservoir. All oxygenators were found to have a dramatic increase in reservoir GME activity when the vent was turned on. Depending on the oxygenator/filter combination, vent return into the oxygenator's integral cardiotomy resulted in the presence of significant amounts of GMEs after the arterial filter.</description><identifier>ISSN: 0022-1058</identifier><identifier>EISSN: 2969-8960</identifier><identifier>DOI: 10.1051/ject/200941020</identifier><identifier>PMID: 19361028</identifier><language>eng</language><publisher>United States: American Society of ExtraCorporeal Technology</publisher><subject>Abstract ; Cardiac Surgical Procedures ; Cardiopulmonary Bypass - adverse effects ; Cardiopulmonary Bypass - instrumentation ; Embolism, Air - etiology ; Extracorporeal Membrane Oxygenation - adverse effects ; Extracorporeal Membrane Oxygenation - instrumentation ; Health technology assessment ; Humans ; In Vitro Techniques ; Risk Factors ; Time Factors</subject><ispartof>The Journal of extra-corporeal technology, 2009-03, Vol.41 (1), p.20-27</ispartof><rights>Copyright 2009 AMSECT 2009</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3690-c47e54ead9448bbf9cb08c05489002ad85c3dccbed1db3be847cb5697bb3329b3</citedby><cites>FETCH-LOGICAL-c3690-c47e54ead9448bbf9cb08c05489002ad85c3dccbed1db3be847cb5697bb3329b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4680219/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4680219/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,723,776,780,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19361028$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Myers, Gerard J</creatorcontrib><creatorcontrib>Voorhees, Cheri</creatorcontrib><creatorcontrib>Haynes, Rob</creatorcontrib><creatorcontrib>Eke, Bob</creatorcontrib><title>Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study</title><title>The Journal of extra-corporeal technology</title><addtitle>J Extra Corpor Technol</addtitle><description>During a previously published study on gaseous microemboli (GMEs) and perfusionist interventions, it was noted that emboli could be detected after the arterial filter when blood/air challenges entered the membrane oxygenator's integral cardiotomy. The findings indicated that further study into the oxygenator's integral cardiotomy reservoir was warranted. This is the first know published report that connects the vent return to GME activity after the arterial filter. To study the air handling ability of the membranes integral cardiotomy, an in vitro study was conducted on five hard shell coated membrane oxygenators (Terumo Capiox SX25, X coated; Sorin Synthesis, phosphorylcholine coated; Gish Vision, GBS coated; Medtronic Affinity NT, trillium coated; Maquet Quadrox, bioline coated). The oxygenators were matched with their own manufacturer's coated arterial filters (Medtronic 351T Arterial Filter, Sorin Synthesis Integrated Arterial Filter, Terumo CXAF200X Arterial Filter, Gish GAF40GBS-2 Arterial Filter, and Maquet Quart HBF140 Arterial Filter). There were three arms to the study, and three separate oxygenator/filter combinations were used in each arm. The first arm consisted of a pump flow of 4.0 L/min with only the filter purge blood entering the integral cardiotomy. In the second arm, 500 mL/min of simulated vent blood was added to the filter purge blood entering the integral cardiotomy. During the final arm, 200 mL/min of air was added to the vent blood as it entered the integral cardiotomy, to more closely simulate vent return during cardiopulmonary bypass. All GME activity in the oxygenator/filter combinations was examined using the Hatteland CMD20 Microemboli Counter. Placement of the Hatteland probes was 4 in after the hard shell reservoir outlet (PRO) and 12 in after the arterial filter (PAF). When vent blood flow was turned on, there was a significant increase in the PRO microemboli activity detected in all reservoirs. In the PAF position, three of the oxygenator/filter combinations were able to remove 98-99% of the GME, one removed 84.3%, and another removed only 55.5% of the GMEs coming out of the oxygenator's reservoir. All oxygenators were found to have a dramatic increase in reservoir GME activity when the vent was turned on. Depending on the oxygenator/filter combination, vent return into the oxygenator's integral cardiotomy resulted in the presence of significant amounts of GMEs after the arterial filter.</description><subject>Abstract</subject><subject>Cardiac Surgical Procedures</subject><subject>Cardiopulmonary Bypass - adverse effects</subject><subject>Cardiopulmonary Bypass - instrumentation</subject><subject>Embolism, Air - etiology</subject><subject>Extracorporeal Membrane Oxygenation - adverse effects</subject><subject>Extracorporeal Membrane Oxygenation - instrumentation</subject><subject>Health technology assessment</subject><subject>Humans</subject><subject>In Vitro Techniques</subject><subject>Risk Factors</subject><subject>Time Factors</subject><issn>0022-1058</issn><issn>2969-8960</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVUU1P3DAUtKoi2G659lj51FvAH4nX5lCpQlCQkOihPVv-eNkaJTHYTqTl1-MVK1pO70meGc-bQegLJWeUdPT8AVw5Z4SolhJGPqAVU0I1UgnyEa0IYaypMHmCPuX8QIighNNjdEIVryuTK_T8K-bSmFQgBTPgPgx1w1uTIc4Zj8GlCKONQ8DGlbCEssOxr7AFcJgKbFMlOZN8iCWOO5wgQ1piSBn7OYVpixeYSp0X2EyVgatCijiX2e8-o6PeDBlOD3ON_lxf_b68ae7uf95e_rhrHBeKNK7dQNeC8aptpbW9cpZIR7pWqnqf8bJz3DtnwVNvuQXZbpzthNpYyzlTlq_R91fdx9mO4F01VF3rxxRGk3Y6mqDfv0zhr97GRbdCElajWqNvB4EUn2bIRY8hOxgGM-1T0mJDGeVCVODZK7CmlnOC_u0TSvS-Lr2vS7_VVQlf_7f2D37oh78AIDCWOA</recordid><startdate>20090301</startdate><enddate>20090301</enddate><creator>Myers, Gerard J</creator><creator>Voorhees, Cheri</creator><creator>Haynes, Rob</creator><creator>Eke, Bob</creator><general>American Society of ExtraCorporeal Technology</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20090301</creationdate><title>Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study</title><author>Myers, Gerard J ; Voorhees, Cheri ; Haynes, Rob ; Eke, Bob</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3690-c47e54ead9448bbf9cb08c05489002ad85c3dccbed1db3be847cb5697bb3329b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Abstract</topic><topic>Cardiac Surgical Procedures</topic><topic>Cardiopulmonary Bypass - adverse effects</topic><topic>Cardiopulmonary Bypass - instrumentation</topic><topic>Embolism, Air - etiology</topic><topic>Extracorporeal Membrane Oxygenation - adverse effects</topic><topic>Extracorporeal Membrane Oxygenation - instrumentation</topic><topic>Health technology assessment</topic><topic>Humans</topic><topic>In Vitro Techniques</topic><topic>Risk Factors</topic><topic>Time Factors</topic><toplevel>online_resources</toplevel><creatorcontrib>Myers, Gerard J</creatorcontrib><creatorcontrib>Voorhees, Cheri</creatorcontrib><creatorcontrib>Haynes, Rob</creatorcontrib><creatorcontrib>Eke, Bob</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>The Journal of extra-corporeal technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Myers, Gerard J</au><au>Voorhees, Cheri</au><au>Haynes, Rob</au><au>Eke, Bob</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study</atitle><jtitle>The Journal of extra-corporeal technology</jtitle><addtitle>J Extra Corpor Technol</addtitle><date>2009-03-01</date><risdate>2009</risdate><volume>41</volume><issue>1</issue><spage>20</spage><epage>27</epage><pages>20-27</pages><issn>0022-1058</issn><eissn>2969-8960</eissn><abstract>During a previously published study on gaseous microemboli (GMEs) and perfusionist interventions, it was noted that emboli could be detected after the arterial filter when blood/air challenges entered the membrane oxygenator's integral cardiotomy. The findings indicated that further study into the oxygenator's integral cardiotomy reservoir was warranted. This is the first know published report that connects the vent return to GME activity after the arterial filter. To study the air handling ability of the membranes integral cardiotomy, an in vitro study was conducted on five hard shell coated membrane oxygenators (Terumo Capiox SX25, X coated; Sorin Synthesis, phosphorylcholine coated; Gish Vision, GBS coated; Medtronic Affinity NT, trillium coated; Maquet Quadrox, bioline coated). The oxygenators were matched with their own manufacturer's coated arterial filters (Medtronic 351T Arterial Filter, Sorin Synthesis Integrated Arterial Filter, Terumo CXAF200X Arterial Filter, Gish GAF40GBS-2 Arterial Filter, and Maquet Quart HBF140 Arterial Filter). There were three arms to the study, and three separate oxygenator/filter combinations were used in each arm. The first arm consisted of a pump flow of 4.0 L/min with only the filter purge blood entering the integral cardiotomy. In the second arm, 500 mL/min of simulated vent blood was added to the filter purge blood entering the integral cardiotomy. During the final arm, 200 mL/min of air was added to the vent blood as it entered the integral cardiotomy, to more closely simulate vent return during cardiopulmonary bypass. All GME activity in the oxygenator/filter combinations was examined using the Hatteland CMD20 Microemboli Counter. Placement of the Hatteland probes was 4 in after the hard shell reservoir outlet (PRO) and 12 in after the arterial filter (PAF). When vent blood flow was turned on, there was a significant increase in the PRO microemboli activity detected in all reservoirs. In the PAF position, three of the oxygenator/filter combinations were able to remove 98-99% of the GME, one removed 84.3%, and another removed only 55.5% of the GMEs coming out of the oxygenator's reservoir. All oxygenators were found to have a dramatic increase in reservoir GME activity when the vent was turned on. Depending on the oxygenator/filter combination, vent return into the oxygenator's integral cardiotomy resulted in the presence of significant amounts of GMEs after the arterial filter.</abstract><cop>United States</cop><pub>American Society of ExtraCorporeal Technology</pub><pmid>19361028</pmid><doi>10.1051/ject/200941020</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0022-1058 |
ispartof | The Journal of extra-corporeal technology, 2009-03, Vol.41 (1), p.20-27 |
issn | 0022-1058 2969-8960 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4680219 |
source | MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central |
subjects | Abstract Cardiac Surgical Procedures Cardiopulmonary Bypass - adverse effects Cardiopulmonary Bypass - instrumentation Embolism, Air - etiology Extracorporeal Membrane Oxygenation - adverse effects Extracorporeal Membrane Oxygenation - instrumentation Health technology assessment Humans In Vitro Techniques Risk Factors Time Factors |
title | Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T23%3A04%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Post-arterial%20filter%20gaseous%20microemboli%20activity%20of%20five%20integral%20cardiotomy%20reservoirs%20during%20venting:%20an%20in%20vitro%20study&rft.jtitle=The%20Journal%20of%20extra-corporeal%20technology&rft.au=Myers,%20Gerard%20J&rft.date=2009-03-01&rft.volume=41&rft.issue=1&rft.spage=20&rft.epage=27&rft.pages=20-27&rft.issn=0022-1058&rft.eissn=2969-8960&rft_id=info:doi/10.1051/ject/200941020&rft_dat=%3Cproquest_pubme%3E67121366%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=67121366&rft_id=info:pmid/19361028&rfr_iscdi=true |