Comparison of gait parameters in distal femoral replacement using a metallic endoprosthesis versus allograft reconstruction
Abstract Background/aim Restoration of gait mechanics after reconstruction have been associated with improved functional outcomes and increased longevity of the reconstruction. The goal of this study is to compare the gait mechanics of an allograft reconstruction of the distal femur to both metallic...
Gespeichert in:
Veröffentlicht in: | Journal of orthopaedics 2015-10, Vol.12 (Suppl 1), p.S25-S30 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | S30 |
---|---|
container_issue | Suppl 1 |
container_start_page | S25 |
container_title | Journal of orthopaedics |
container_volume | 12 |
creator | AlGheshyan, Fahad Eltoukhy, Moataz Zakaria, Khaled Temple, Harry Thomas Asfour, Shihab |
description | Abstract Background/aim Restoration of gait mechanics after reconstruction have been associated with improved functional outcomes and increased longevity of the reconstruction. The goal of this study is to compare the gait mechanics of an allograft reconstruction of the distal femur to both metallic endoprosthetic reconstruction relative to normal control subjects. Methods Gait parameters were captured using motion capture system, and then analyzed and compared for patients with metallic endoprosthetic reconstructions, and patients with allograft reconstructions of the distal femur following resection of malignant bone tumor, with subjects having no history of musculoskeletal disorders serving as a control group. Results All reconstructed distal femurs following tumor resection resulted in decreased range of motion reflected in observed flexion/extension angles compared to the normal limbs. The allograft reconstructed knees demonstrated normal patterns of rotation whereas the metal subjects had abnormal patterns of rotation and statistically significant differences in rotational moments. Conclusion Allograft distal femoral reconstruction after malignant excision remains a viable option for surgeons faced with problems associated with iatrogenic muscle, bone and soft tissue defects. |
doi_str_mv | 10.1016/j.jor.2015.01.022 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4674537</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0972978X15000239</els_id><sourcerecordid>1753011551</sourcerecordid><originalsourceid>FETCH-LOGICAL-c506t-87f3d484cb2240f46b806f70dcd8aff9ee3b970acf83f4fe086199abd766f3ec3</originalsourceid><addsrcrecordid>eNp9Uk2LFDEQbURx19Uf4EVy9DJtJelOuhEWZFg_YMGDCt5COl2ZTdudjEl6YPHPm2HWZfXgqRLqvZfKe1VVLynUFKh4M9VTiDUD2tZAa2DsUXUOvWSbXnbfHz84n1XPUpoAOGsFf1qdMSFpL1h7Xv3ahmWvo0vBk2DJTrtMyl0vmDEm4jwZXcp6JhaXEEuNuJ-1wQV9Jmtyfkc0KWA9z84Q9GPYx5DyDSaXyKFIrImUXthFbXMhm-BTjqvJLvjn1ROr54Qv7upF9e391dftx8315w-ftu-uN6YFkTedtHxsusYMjDVgGzF0IKyE0YydtrZH5EMvQRvbcdtYhE7QvtfDKIWwHA2_qC5Puvt1WHA0ZfTyE7WPbtHxVgXt1N8d727ULhxUI2TTclkEXt8JxPBzxZTV4pLBedYew5oUlS0HStuWFig9QU2xIUW0989QUMfQ1KRKaOoYmgKqSmiF8-rhfPeMPykVwNsTAItLB4dRJePQGxxdcTSrMbj_yl_-wzaz887o-QfeYprCGn2xX1GVmAL15bg1x6WhLQAw3vPf9WvCoQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1753011551</pqid></control><display><type>article</type><title>Comparison of gait parameters in distal femoral replacement using a metallic endoprosthesis versus allograft reconstruction</title><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>AlGheshyan, Fahad ; Eltoukhy, Moataz ; Zakaria, Khaled ; Temple, Harry Thomas ; Asfour, Shihab</creator><creatorcontrib>AlGheshyan, Fahad ; Eltoukhy, Moataz ; Zakaria, Khaled ; Temple, Harry Thomas ; Asfour, Shihab</creatorcontrib><description>Abstract Background/aim Restoration of gait mechanics after reconstruction have been associated with improved functional outcomes and increased longevity of the reconstruction. The goal of this study is to compare the gait mechanics of an allograft reconstruction of the distal femur to both metallic endoprosthetic reconstruction relative to normal control subjects. Methods Gait parameters were captured using motion capture system, and then analyzed and compared for patients with metallic endoprosthetic reconstructions, and patients with allograft reconstructions of the distal femur following resection of malignant bone tumor, with subjects having no history of musculoskeletal disorders serving as a control group. Results All reconstructed distal femurs following tumor resection resulted in decreased range of motion reflected in observed flexion/extension angles compared to the normal limbs. The allograft reconstructed knees demonstrated normal patterns of rotation whereas the metal subjects had abnormal patterns of rotation and statistically significant differences in rotational moments. Conclusion Allograft distal femoral reconstruction after malignant excision remains a viable option for surgeons faced with problems associated with iatrogenic muscle, bone and soft tissue defects.</description><identifier>ISSN: 0972-978X</identifier><identifier>EISSN: 0972-978X</identifier><identifier>DOI: 10.1016/j.jor.2015.01.022</identifier><identifier>PMID: 26719625</identifier><language>eng</language><publisher>India: Elsevier B.V</publisher><subject>Distal femoral replacement ; Gait analysis ; Motion capture ; Original ; Orthopedics</subject><ispartof>Journal of orthopaedics, 2015-10, Vol.12 (Suppl 1), p.S25-S30</ispartof><rights>Prof. P K Surendran Memorial Education Foundation</rights><rights>2015 Prof. P K Surendran Memorial Education Foundation</rights><rights>Copyright © 2015, Professor P K Surendran Memorial Education Foundation. Publishing Services by Reed Elsevier India Pvt. Ltd. All rights reserved. 2015 Prof. P K Surendran Memorial Education Foundation</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c506t-87f3d484cb2240f46b806f70dcd8aff9ee3b970acf83f4fe086199abd766f3ec3</citedby><cites>FETCH-LOGICAL-c506t-87f3d484cb2240f46b806f70dcd8aff9ee3b970acf83f4fe086199abd766f3ec3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4674537/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4674537/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26719625$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>AlGheshyan, Fahad</creatorcontrib><creatorcontrib>Eltoukhy, Moataz</creatorcontrib><creatorcontrib>Zakaria, Khaled</creatorcontrib><creatorcontrib>Temple, Harry Thomas</creatorcontrib><creatorcontrib>Asfour, Shihab</creatorcontrib><title>Comparison of gait parameters in distal femoral replacement using a metallic endoprosthesis versus allograft reconstruction</title><title>Journal of orthopaedics</title><addtitle>J Orthop</addtitle><description>Abstract Background/aim Restoration of gait mechanics after reconstruction have been associated with improved functional outcomes and increased longevity of the reconstruction. The goal of this study is to compare the gait mechanics of an allograft reconstruction of the distal femur to both metallic endoprosthetic reconstruction relative to normal control subjects. Methods Gait parameters were captured using motion capture system, and then analyzed and compared for patients with metallic endoprosthetic reconstructions, and patients with allograft reconstructions of the distal femur following resection of malignant bone tumor, with subjects having no history of musculoskeletal disorders serving as a control group. Results All reconstructed distal femurs following tumor resection resulted in decreased range of motion reflected in observed flexion/extension angles compared to the normal limbs. The allograft reconstructed knees demonstrated normal patterns of rotation whereas the metal subjects had abnormal patterns of rotation and statistically significant differences in rotational moments. Conclusion Allograft distal femoral reconstruction after malignant excision remains a viable option for surgeons faced with problems associated with iatrogenic muscle, bone and soft tissue defects.</description><subject>Distal femoral replacement</subject><subject>Gait analysis</subject><subject>Motion capture</subject><subject>Original</subject><subject>Orthopedics</subject><issn>0972-978X</issn><issn>0972-978X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNp9Uk2LFDEQbURx19Uf4EVy9DJtJelOuhEWZFg_YMGDCt5COl2ZTdudjEl6YPHPm2HWZfXgqRLqvZfKe1VVLynUFKh4M9VTiDUD2tZAa2DsUXUOvWSbXnbfHz84n1XPUpoAOGsFf1qdMSFpL1h7Xv3ahmWvo0vBk2DJTrtMyl0vmDEm4jwZXcp6JhaXEEuNuJ-1wQV9Jmtyfkc0KWA9z84Q9GPYx5DyDSaXyKFIrImUXthFbXMhm-BTjqvJLvjn1ROr54Qv7upF9e391dftx8315w-ftu-uN6YFkTedtHxsusYMjDVgGzF0IKyE0YydtrZH5EMvQRvbcdtYhE7QvtfDKIWwHA2_qC5Puvt1WHA0ZfTyE7WPbtHxVgXt1N8d727ULhxUI2TTclkEXt8JxPBzxZTV4pLBedYew5oUlS0HStuWFig9QU2xIUW0989QUMfQ1KRKaOoYmgKqSmiF8-rhfPeMPykVwNsTAItLB4dRJePQGxxdcTSrMbj_yl_-wzaz887o-QfeYprCGn2xX1GVmAL15bg1x6WhLQAw3vPf9WvCoQ</recordid><startdate>20151001</startdate><enddate>20151001</enddate><creator>AlGheshyan, Fahad</creator><creator>Eltoukhy, Moataz</creator><creator>Zakaria, Khaled</creator><creator>Temple, Harry Thomas</creator><creator>Asfour, Shihab</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20151001</creationdate><title>Comparison of gait parameters in distal femoral replacement using a metallic endoprosthesis versus allograft reconstruction</title><author>AlGheshyan, Fahad ; Eltoukhy, Moataz ; Zakaria, Khaled ; Temple, Harry Thomas ; Asfour, Shihab</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c506t-87f3d484cb2240f46b806f70dcd8aff9ee3b970acf83f4fe086199abd766f3ec3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Distal femoral replacement</topic><topic>Gait analysis</topic><topic>Motion capture</topic><topic>Original</topic><topic>Orthopedics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>AlGheshyan, Fahad</creatorcontrib><creatorcontrib>Eltoukhy, Moataz</creatorcontrib><creatorcontrib>Zakaria, Khaled</creatorcontrib><creatorcontrib>Temple, Harry Thomas</creatorcontrib><creatorcontrib>Asfour, Shihab</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of orthopaedics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>AlGheshyan, Fahad</au><au>Eltoukhy, Moataz</au><au>Zakaria, Khaled</au><au>Temple, Harry Thomas</au><au>Asfour, Shihab</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of gait parameters in distal femoral replacement using a metallic endoprosthesis versus allograft reconstruction</atitle><jtitle>Journal of orthopaedics</jtitle><addtitle>J Orthop</addtitle><date>2015-10-01</date><risdate>2015</risdate><volume>12</volume><issue>Suppl 1</issue><spage>S25</spage><epage>S30</epage><pages>S25-S30</pages><issn>0972-978X</issn><eissn>0972-978X</eissn><abstract>Abstract Background/aim Restoration of gait mechanics after reconstruction have been associated with improved functional outcomes and increased longevity of the reconstruction. The goal of this study is to compare the gait mechanics of an allograft reconstruction of the distal femur to both metallic endoprosthetic reconstruction relative to normal control subjects. Methods Gait parameters were captured using motion capture system, and then analyzed and compared for patients with metallic endoprosthetic reconstructions, and patients with allograft reconstructions of the distal femur following resection of malignant bone tumor, with subjects having no history of musculoskeletal disorders serving as a control group. Results All reconstructed distal femurs following tumor resection resulted in decreased range of motion reflected in observed flexion/extension angles compared to the normal limbs. The allograft reconstructed knees demonstrated normal patterns of rotation whereas the metal subjects had abnormal patterns of rotation and statistically significant differences in rotational moments. Conclusion Allograft distal femoral reconstruction after malignant excision remains a viable option for surgeons faced with problems associated with iatrogenic muscle, bone and soft tissue defects.</abstract><cop>India</cop><pub>Elsevier B.V</pub><pmid>26719625</pmid><doi>10.1016/j.jor.2015.01.022</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0972-978X |
ispartof | Journal of orthopaedics, 2015-10, Vol.12 (Suppl 1), p.S25-S30 |
issn | 0972-978X 0972-978X |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4674537 |
source | EZB-FREE-00999 freely available EZB journals; PubMed Central; Alma/SFX Local Collection |
subjects | Distal femoral replacement Gait analysis Motion capture Original Orthopedics |
title | Comparison of gait parameters in distal femoral replacement using a metallic endoprosthesis versus allograft reconstruction |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T17%3A46%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20gait%20parameters%20in%20distal%20femoral%20replacement%20using%20a%20metallic%20endoprosthesis%20versus%20allograft%20reconstruction&rft.jtitle=Journal%20of%20orthopaedics&rft.au=AlGheshyan,%20Fahad&rft.date=2015-10-01&rft.volume=12&rft.issue=Suppl%201&rft.spage=S25&rft.epage=S30&rft.pages=S25-S30&rft.issn=0972-978X&rft.eissn=0972-978X&rft_id=info:doi/10.1016/j.jor.2015.01.022&rft_dat=%3Cproquest_pubme%3E1753011551%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1753011551&rft_id=info:pmid/26719625&rft_els_id=S0972978X15000239&rfr_iscdi=true |