Comparison of gait parameters in distal femoral replacement using a metallic endoprosthesis versus allograft reconstruction

Abstract Background/aim Restoration of gait mechanics after reconstruction have been associated with improved functional outcomes and increased longevity of the reconstruction. The goal of this study is to compare the gait mechanics of an allograft reconstruction of the distal femur to both metallic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of orthopaedics 2015-10, Vol.12 (Suppl 1), p.S25-S30
Hauptverfasser: AlGheshyan, Fahad, Eltoukhy, Moataz, Zakaria, Khaled, Temple, Harry Thomas, Asfour, Shihab
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page S30
container_issue Suppl 1
container_start_page S25
container_title Journal of orthopaedics
container_volume 12
creator AlGheshyan, Fahad
Eltoukhy, Moataz
Zakaria, Khaled
Temple, Harry Thomas
Asfour, Shihab
description Abstract Background/aim Restoration of gait mechanics after reconstruction have been associated with improved functional outcomes and increased longevity of the reconstruction. The goal of this study is to compare the gait mechanics of an allograft reconstruction of the distal femur to both metallic endoprosthetic reconstruction relative to normal control subjects. Methods Gait parameters were captured using motion capture system, and then analyzed and compared for patients with metallic endoprosthetic reconstructions, and patients with allograft reconstructions of the distal femur following resection of malignant bone tumor, with subjects having no history of musculoskeletal disorders serving as a control group. Results All reconstructed distal femurs following tumor resection resulted in decreased range of motion reflected in observed flexion/extension angles compared to the normal limbs. The allograft reconstructed knees demonstrated normal patterns of rotation whereas the metal subjects had abnormal patterns of rotation and statistically significant differences in rotational moments. Conclusion Allograft distal femoral reconstruction after malignant excision remains a viable option for surgeons faced with problems associated with iatrogenic muscle, bone and soft tissue defects.
doi_str_mv 10.1016/j.jor.2015.01.022
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4674537</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0972978X15000239</els_id><sourcerecordid>1753011551</sourcerecordid><originalsourceid>FETCH-LOGICAL-c506t-87f3d484cb2240f46b806f70dcd8aff9ee3b970acf83f4fe086199abd766f3ec3</originalsourceid><addsrcrecordid>eNp9Uk2LFDEQbURx19Uf4EVy9DJtJelOuhEWZFg_YMGDCt5COl2ZTdudjEl6YPHPm2HWZfXgqRLqvZfKe1VVLynUFKh4M9VTiDUD2tZAa2DsUXUOvWSbXnbfHz84n1XPUpoAOGsFf1qdMSFpL1h7Xv3ahmWvo0vBk2DJTrtMyl0vmDEm4jwZXcp6JhaXEEuNuJ-1wQV9Jmtyfkc0KWA9z84Q9GPYx5DyDSaXyKFIrImUXthFbXMhm-BTjqvJLvjn1ROr54Qv7upF9e391dftx8315w-ftu-uN6YFkTedtHxsusYMjDVgGzF0IKyE0YydtrZH5EMvQRvbcdtYhE7QvtfDKIWwHA2_qC5Puvt1WHA0ZfTyE7WPbtHxVgXt1N8d727ULhxUI2TTclkEXt8JxPBzxZTV4pLBedYew5oUlS0HStuWFig9QU2xIUW0989QUMfQ1KRKaOoYmgKqSmiF8-rhfPeMPykVwNsTAItLB4dRJePQGxxdcTSrMbj_yl_-wzaz887o-QfeYprCGn2xX1GVmAL15bg1x6WhLQAw3vPf9WvCoQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1753011551</pqid></control><display><type>article</type><title>Comparison of gait parameters in distal femoral replacement using a metallic endoprosthesis versus allograft reconstruction</title><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>AlGheshyan, Fahad ; Eltoukhy, Moataz ; Zakaria, Khaled ; Temple, Harry Thomas ; Asfour, Shihab</creator><creatorcontrib>AlGheshyan, Fahad ; Eltoukhy, Moataz ; Zakaria, Khaled ; Temple, Harry Thomas ; Asfour, Shihab</creatorcontrib><description>Abstract Background/aim Restoration of gait mechanics after reconstruction have been associated with improved functional outcomes and increased longevity of the reconstruction. The goal of this study is to compare the gait mechanics of an allograft reconstruction of the distal femur to both metallic endoprosthetic reconstruction relative to normal control subjects. Methods Gait parameters were captured using motion capture system, and then analyzed and compared for patients with metallic endoprosthetic reconstructions, and patients with allograft reconstructions of the distal femur following resection of malignant bone tumor, with subjects having no history of musculoskeletal disorders serving as a control group. Results All reconstructed distal femurs following tumor resection resulted in decreased range of motion reflected in observed flexion/extension angles compared to the normal limbs. The allograft reconstructed knees demonstrated normal patterns of rotation whereas the metal subjects had abnormal patterns of rotation and statistically significant differences in rotational moments. Conclusion Allograft distal femoral reconstruction after malignant excision remains a viable option for surgeons faced with problems associated with iatrogenic muscle, bone and soft tissue defects.</description><identifier>ISSN: 0972-978X</identifier><identifier>EISSN: 0972-978X</identifier><identifier>DOI: 10.1016/j.jor.2015.01.022</identifier><identifier>PMID: 26719625</identifier><language>eng</language><publisher>India: Elsevier B.V</publisher><subject>Distal femoral replacement ; Gait analysis ; Motion capture ; Original ; Orthopedics</subject><ispartof>Journal of orthopaedics, 2015-10, Vol.12 (Suppl 1), p.S25-S30</ispartof><rights>Prof. P K Surendran Memorial Education Foundation</rights><rights>2015 Prof. P K Surendran Memorial Education Foundation</rights><rights>Copyright © 2015, Professor P K Surendran Memorial Education Foundation. Publishing Services by Reed Elsevier India Pvt. Ltd. All rights reserved. 2015 Prof. P K Surendran Memorial Education Foundation</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c506t-87f3d484cb2240f46b806f70dcd8aff9ee3b970acf83f4fe086199abd766f3ec3</citedby><cites>FETCH-LOGICAL-c506t-87f3d484cb2240f46b806f70dcd8aff9ee3b970acf83f4fe086199abd766f3ec3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4674537/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4674537/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26719625$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>AlGheshyan, Fahad</creatorcontrib><creatorcontrib>Eltoukhy, Moataz</creatorcontrib><creatorcontrib>Zakaria, Khaled</creatorcontrib><creatorcontrib>Temple, Harry Thomas</creatorcontrib><creatorcontrib>Asfour, Shihab</creatorcontrib><title>Comparison of gait parameters in distal femoral replacement using a metallic endoprosthesis versus allograft reconstruction</title><title>Journal of orthopaedics</title><addtitle>J Orthop</addtitle><description>Abstract Background/aim Restoration of gait mechanics after reconstruction have been associated with improved functional outcomes and increased longevity of the reconstruction. The goal of this study is to compare the gait mechanics of an allograft reconstruction of the distal femur to both metallic endoprosthetic reconstruction relative to normal control subjects. Methods Gait parameters were captured using motion capture system, and then analyzed and compared for patients with metallic endoprosthetic reconstructions, and patients with allograft reconstructions of the distal femur following resection of malignant bone tumor, with subjects having no history of musculoskeletal disorders serving as a control group. Results All reconstructed distal femurs following tumor resection resulted in decreased range of motion reflected in observed flexion/extension angles compared to the normal limbs. The allograft reconstructed knees demonstrated normal patterns of rotation whereas the metal subjects had abnormal patterns of rotation and statistically significant differences in rotational moments. Conclusion Allograft distal femoral reconstruction after malignant excision remains a viable option for surgeons faced with problems associated with iatrogenic muscle, bone and soft tissue defects.</description><subject>Distal femoral replacement</subject><subject>Gait analysis</subject><subject>Motion capture</subject><subject>Original</subject><subject>Orthopedics</subject><issn>0972-978X</issn><issn>0972-978X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNp9Uk2LFDEQbURx19Uf4EVy9DJtJelOuhEWZFg_YMGDCt5COl2ZTdudjEl6YPHPm2HWZfXgqRLqvZfKe1VVLynUFKh4M9VTiDUD2tZAa2DsUXUOvWSbXnbfHz84n1XPUpoAOGsFf1qdMSFpL1h7Xv3ahmWvo0vBk2DJTrtMyl0vmDEm4jwZXcp6JhaXEEuNuJ-1wQV9Jmtyfkc0KWA9z84Q9GPYx5DyDSaXyKFIrImUXthFbXMhm-BTjqvJLvjn1ROr54Qv7upF9e391dftx8315w-ftu-uN6YFkTedtHxsusYMjDVgGzF0IKyE0YydtrZH5EMvQRvbcdtYhE7QvtfDKIWwHA2_qC5Puvt1WHA0ZfTyE7WPbtHxVgXt1N8d727ULhxUI2TTclkEXt8JxPBzxZTV4pLBedYew5oUlS0HStuWFig9QU2xIUW0989QUMfQ1KRKaOoYmgKqSmiF8-rhfPeMPykVwNsTAItLB4dRJePQGxxdcTSrMbj_yl_-wzaz887o-QfeYprCGn2xX1GVmAL15bg1x6WhLQAw3vPf9WvCoQ</recordid><startdate>20151001</startdate><enddate>20151001</enddate><creator>AlGheshyan, Fahad</creator><creator>Eltoukhy, Moataz</creator><creator>Zakaria, Khaled</creator><creator>Temple, Harry Thomas</creator><creator>Asfour, Shihab</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20151001</creationdate><title>Comparison of gait parameters in distal femoral replacement using a metallic endoprosthesis versus allograft reconstruction</title><author>AlGheshyan, Fahad ; Eltoukhy, Moataz ; Zakaria, Khaled ; Temple, Harry Thomas ; Asfour, Shihab</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c506t-87f3d484cb2240f46b806f70dcd8aff9ee3b970acf83f4fe086199abd766f3ec3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Distal femoral replacement</topic><topic>Gait analysis</topic><topic>Motion capture</topic><topic>Original</topic><topic>Orthopedics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>AlGheshyan, Fahad</creatorcontrib><creatorcontrib>Eltoukhy, Moataz</creatorcontrib><creatorcontrib>Zakaria, Khaled</creatorcontrib><creatorcontrib>Temple, Harry Thomas</creatorcontrib><creatorcontrib>Asfour, Shihab</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of orthopaedics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>AlGheshyan, Fahad</au><au>Eltoukhy, Moataz</au><au>Zakaria, Khaled</au><au>Temple, Harry Thomas</au><au>Asfour, Shihab</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of gait parameters in distal femoral replacement using a metallic endoprosthesis versus allograft reconstruction</atitle><jtitle>Journal of orthopaedics</jtitle><addtitle>J Orthop</addtitle><date>2015-10-01</date><risdate>2015</risdate><volume>12</volume><issue>Suppl 1</issue><spage>S25</spage><epage>S30</epage><pages>S25-S30</pages><issn>0972-978X</issn><eissn>0972-978X</eissn><abstract>Abstract Background/aim Restoration of gait mechanics after reconstruction have been associated with improved functional outcomes and increased longevity of the reconstruction. The goal of this study is to compare the gait mechanics of an allograft reconstruction of the distal femur to both metallic endoprosthetic reconstruction relative to normal control subjects. Methods Gait parameters were captured using motion capture system, and then analyzed and compared for patients with metallic endoprosthetic reconstructions, and patients with allograft reconstructions of the distal femur following resection of malignant bone tumor, with subjects having no history of musculoskeletal disorders serving as a control group. Results All reconstructed distal femurs following tumor resection resulted in decreased range of motion reflected in observed flexion/extension angles compared to the normal limbs. The allograft reconstructed knees demonstrated normal patterns of rotation whereas the metal subjects had abnormal patterns of rotation and statistically significant differences in rotational moments. Conclusion Allograft distal femoral reconstruction after malignant excision remains a viable option for surgeons faced with problems associated with iatrogenic muscle, bone and soft tissue defects.</abstract><cop>India</cop><pub>Elsevier B.V</pub><pmid>26719625</pmid><doi>10.1016/j.jor.2015.01.022</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0972-978X
ispartof Journal of orthopaedics, 2015-10, Vol.12 (Suppl 1), p.S25-S30
issn 0972-978X
0972-978X
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4674537
source EZB-FREE-00999 freely available EZB journals; PubMed Central; Alma/SFX Local Collection
subjects Distal femoral replacement
Gait analysis
Motion capture
Original
Orthopedics
title Comparison of gait parameters in distal femoral replacement using a metallic endoprosthesis versus allograft reconstruction
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T17%3A46%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20gait%20parameters%20in%20distal%20femoral%20replacement%20using%20a%20metallic%20endoprosthesis%20versus%20allograft%20reconstruction&rft.jtitle=Journal%20of%20orthopaedics&rft.au=AlGheshyan,%20Fahad&rft.date=2015-10-01&rft.volume=12&rft.issue=Suppl%201&rft.spage=S25&rft.epage=S30&rft.pages=S25-S30&rft.issn=0972-978X&rft.eissn=0972-978X&rft_id=info:doi/10.1016/j.jor.2015.01.022&rft_dat=%3Cproquest_pubme%3E1753011551%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1753011551&rft_id=info:pmid/26719625&rft_els_id=S0972978X15000239&rfr_iscdi=true