Analysis of thermal characteristics of electrical wiring for load groups in cattle barns

The purpose of the current study is to analyze the thermal characteristics of electrical wirings depending on the number of operating load by connecting four types of electrical wirings that are selected by surveying the conditions for the electric fans, automatic waterers and halogen warm lamps tha...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Industrial Health 2015, Vol.53(6), pp.505-510
Hauptverfasser: KIM, Doo Hyun, YOO, Sang-Ok, KIM, Sung Chul, HWANG, Dong Kyu
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 510
container_issue 6
container_start_page 505
container_title Industrial Health
container_volume 53
creator KIM, Doo Hyun
YOO, Sang-Ok
KIM, Sung Chul
HWANG, Dong Kyu
description The purpose of the current study is to analyze the thermal characteristics of electrical wirings depending on the number of operating load by connecting four types of electrical wirings that are selected by surveying the conditions for the electric fans, automatic waterers and halogen warm lamps that were installed in cattle barns in different years. The conditions of 64 cattle barns were surveyed and an experimental test was conducted at a cattle barn. The condition-survey covered inappropriate design, construction and misuse of electrical facility, including electrical wiring mostly used, and the mode of load current was evaluated. The survey showed that the mode of load current increased as the installation year of the fans, waterers and halogen lamps became older. Accordingly, the cattle barn manager needed to increase the capacity of the circuit breaker, which promoted the degradation of insulation of the electrical wires’ sheath and increased possibility for electrical fires in the long-run. The test showed that the saturation temperature of the wire insulated sheath increased depending on the installation year of the load groups, in case of VCTFK and VFF electric wires, therefore, requiring their careful usage in the cattle barns.
doi_str_mv 10.2486/indhealth.2014-0235
format Article
fullrecord <record><control><sourceid>gale_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4667040</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A446532940</galeid><sourcerecordid>A446532940</sourcerecordid><originalsourceid>FETCH-LOGICAL-c669t-7b13f6b2ee1d406d68e0d2610b12c03acc30eae98768d709c164dfe95f2fcc463</originalsourceid><addsrcrecordid>eNptkt1q3DAQhUVpaLZpn6BQDIXceasfW2vfFJaQtoFAb1LonZDlka0gS4ukbcnbV143JgtFIMHMdw4zHCH0geAtrRr-2bh-BGnTuKWYVCWmrH6FNqRpcNlgyl-jDcakLRvG-SV6G-MjxozXLXuDLiknmavrDfq1d9I-RRMLr4s0QpikLdQog1QJgonJqFMLLKgUjMrdPyYYNxTah8J62RdD8MdDLIwrlEzJQtHJ4OI7dKGljfD-33uFfn69fbj5Xt7_-HZ3s78vFedtKncdYZp3FID0FeY9bwD3eTzcEaowk0oxDBLaZsebfodbRXjVa2hrTbVSFWdX6Mviezh2E_QKXArSikMwkwxPwksjzjvOjGLwv0XF-Q5XOBt8WgwGaUEYp33G1GSiEvuq4jWj7Yna_ofKp4fJKO9Am1w_E1y_ECxBRW-PyXgXz0G2gCr4GAPodXaCxRy0WIMWc9BiDjqrPr5ce9U8J5uBuwV4jEkOsAIy5EhPKzyb1kzw-VrNV2b-BwIc-wthyMGg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Analysis of thermal characteristics of electrical wiring for load groups in cattle barns</title><source>PubMed (Medline)</source><source>J-STAGE Free</source><source>MEDLINE</source><source>EZB Electronic Journals Library</source><source>PubMed Central Open Access</source><creator>KIM, Doo Hyun ; YOO, Sang-Ok ; KIM, Sung Chul ; HWANG, Dong Kyu</creator><creatorcontrib>KIM, Doo Hyun ; YOO, Sang-Ok ; KIM, Sung Chul ; HWANG, Dong Kyu</creatorcontrib><description>The purpose of the current study is to analyze the thermal characteristics of electrical wirings depending on the number of operating load by connecting four types of electrical wirings that are selected by surveying the conditions for the electric fans, automatic waterers and halogen warm lamps that were installed in cattle barns in different years. The conditions of 64 cattle barns were surveyed and an experimental test was conducted at a cattle barn. The condition-survey covered inappropriate design, construction and misuse of electrical facility, including electrical wiring mostly used, and the mode of load current was evaluated. The survey showed that the mode of load current increased as the installation year of the fans, waterers and halogen lamps became older. Accordingly, the cattle barn manager needed to increase the capacity of the circuit breaker, which promoted the degradation of insulation of the electrical wires’ sheath and increased possibility for electrical fires in the long-run. The test showed that the saturation temperature of the wire insulated sheath increased depending on the installation year of the load groups, in case of VCTFK and VFF electric wires, therefore, requiring their careful usage in the cattle barns.</description><identifier>ISSN: 0019-8366</identifier><identifier>EISSN: 1880-8026</identifier><identifier>DOI: 10.2486/indhealth.2014-0235</identifier><identifier>PMID: 26118855</identifier><language>eng</language><publisher>Japan: National Institute of Occupational Safety and Health</publisher><subject>Agriculture - instrumentation ; Analysis ; Animals ; Barns ; Cattle ; Cattle barn ; Electric wire ; Electric wiring ; Electric Wiring - standards ; Electrical fire ; Materials Testing ; Mode of load current ; Original ; Safety ; Temperature ; Thermal characteristics ; Thermal Conductivity ; Thermal properties ; Time Factors</subject><ispartof>Industrial Health, 2015, Vol.53(6), pp.505-510</ispartof><rights>2015 by National Institute of Occupational Safety and Health</rights><rights>COPYRIGHT 2015 National Institute of Occupational Safety and Health, Japan</rights><rights>2015 National Institute of Occupational Safety and Health 2015</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4667040/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4667040/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,1881,4021,27921,27922,27923,53789,53791</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26118855$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>KIM, Doo Hyun</creatorcontrib><creatorcontrib>YOO, Sang-Ok</creatorcontrib><creatorcontrib>KIM, Sung Chul</creatorcontrib><creatorcontrib>HWANG, Dong Kyu</creatorcontrib><title>Analysis of thermal characteristics of electrical wiring for load groups in cattle barns</title><title>Industrial Health</title><addtitle>Ind Health</addtitle><description>The purpose of the current study is to analyze the thermal characteristics of electrical wirings depending on the number of operating load by connecting four types of electrical wirings that are selected by surveying the conditions for the electric fans, automatic waterers and halogen warm lamps that were installed in cattle barns in different years. The conditions of 64 cattle barns were surveyed and an experimental test was conducted at a cattle barn. The condition-survey covered inappropriate design, construction and misuse of electrical facility, including electrical wiring mostly used, and the mode of load current was evaluated. The survey showed that the mode of load current increased as the installation year of the fans, waterers and halogen lamps became older. Accordingly, the cattle barn manager needed to increase the capacity of the circuit breaker, which promoted the degradation of insulation of the electrical wires’ sheath and increased possibility for electrical fires in the long-run. The test showed that the saturation temperature of the wire insulated sheath increased depending on the installation year of the load groups, in case of VCTFK and VFF electric wires, therefore, requiring their careful usage in the cattle barns.</description><subject>Agriculture - instrumentation</subject><subject>Analysis</subject><subject>Animals</subject><subject>Barns</subject><subject>Cattle</subject><subject>Cattle barn</subject><subject>Electric wire</subject><subject>Electric wiring</subject><subject>Electric Wiring - standards</subject><subject>Electrical fire</subject><subject>Materials Testing</subject><subject>Mode of load current</subject><subject>Original</subject><subject>Safety</subject><subject>Temperature</subject><subject>Thermal characteristics</subject><subject>Thermal Conductivity</subject><subject>Thermal properties</subject><subject>Time Factors</subject><issn>0019-8366</issn><issn>1880-8026</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNptkt1q3DAQhUVpaLZpn6BQDIXceasfW2vfFJaQtoFAb1LonZDlka0gS4ukbcnbV143JgtFIMHMdw4zHCH0geAtrRr-2bh-BGnTuKWYVCWmrH6FNqRpcNlgyl-jDcakLRvG-SV6G-MjxozXLXuDLiknmavrDfq1d9I-RRMLr4s0QpikLdQog1QJgonJqFMLLKgUjMrdPyYYNxTah8J62RdD8MdDLIwrlEzJQtHJ4OI7dKGljfD-33uFfn69fbj5Xt7_-HZ3s78vFedtKncdYZp3FID0FeY9bwD3eTzcEaowk0oxDBLaZsebfodbRXjVa2hrTbVSFWdX6Mviezh2E_QKXArSikMwkwxPwksjzjvOjGLwv0XF-Q5XOBt8WgwGaUEYp33G1GSiEvuq4jWj7Yna_ofKp4fJKO9Am1w_E1y_ECxBRW-PyXgXz0G2gCr4GAPodXaCxRy0WIMWc9BiDjqrPr5ce9U8J5uBuwV4jEkOsAIy5EhPKzyb1kzw-VrNV2b-BwIc-wthyMGg</recordid><startdate>2015</startdate><enddate>2015</enddate><creator>KIM, Doo Hyun</creator><creator>YOO, Sang-Ok</creator><creator>KIM, Sung Chul</creator><creator>HWANG, Dong Kyu</creator><general>National Institute of Occupational Safety and Health</general><general>National Institute of Occupational Safety and Health, Japan</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>5PM</scope></search><sort><creationdate>2015</creationdate><title>Analysis of thermal characteristics of electrical wiring for load groups in cattle barns</title><author>KIM, Doo Hyun ; YOO, Sang-Ok ; KIM, Sung Chul ; HWANG, Dong Kyu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c669t-7b13f6b2ee1d406d68e0d2610b12c03acc30eae98768d709c164dfe95f2fcc463</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Agriculture - instrumentation</topic><topic>Analysis</topic><topic>Animals</topic><topic>Barns</topic><topic>Cattle</topic><topic>Cattle barn</topic><topic>Electric wire</topic><topic>Electric wiring</topic><topic>Electric Wiring - standards</topic><topic>Electrical fire</topic><topic>Materials Testing</topic><topic>Mode of load current</topic><topic>Original</topic><topic>Safety</topic><topic>Temperature</topic><topic>Thermal characteristics</topic><topic>Thermal Conductivity</topic><topic>Thermal properties</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>KIM, Doo Hyun</creatorcontrib><creatorcontrib>YOO, Sang-Ok</creatorcontrib><creatorcontrib>KIM, Sung Chul</creatorcontrib><creatorcontrib>HWANG, Dong Kyu</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Industrial Health</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KIM, Doo Hyun</au><au>YOO, Sang-Ok</au><au>KIM, Sung Chul</au><au>HWANG, Dong Kyu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Analysis of thermal characteristics of electrical wiring for load groups in cattle barns</atitle><jtitle>Industrial Health</jtitle><addtitle>Ind Health</addtitle><date>2015</date><risdate>2015</risdate><volume>53</volume><issue>6</issue><spage>505</spage><epage>510</epage><pages>505-510</pages><issn>0019-8366</issn><eissn>1880-8026</eissn><abstract>The purpose of the current study is to analyze the thermal characteristics of electrical wirings depending on the number of operating load by connecting four types of electrical wirings that are selected by surveying the conditions for the electric fans, automatic waterers and halogen warm lamps that were installed in cattle barns in different years. The conditions of 64 cattle barns were surveyed and an experimental test was conducted at a cattle barn. The condition-survey covered inappropriate design, construction and misuse of electrical facility, including electrical wiring mostly used, and the mode of load current was evaluated. The survey showed that the mode of load current increased as the installation year of the fans, waterers and halogen lamps became older. Accordingly, the cattle barn manager needed to increase the capacity of the circuit breaker, which promoted the degradation of insulation of the electrical wires’ sheath and increased possibility for electrical fires in the long-run. The test showed that the saturation temperature of the wire insulated sheath increased depending on the installation year of the load groups, in case of VCTFK and VFF electric wires, therefore, requiring their careful usage in the cattle barns.</abstract><cop>Japan</cop><pub>National Institute of Occupational Safety and Health</pub><pmid>26118855</pmid><doi>10.2486/indhealth.2014-0235</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0019-8366
ispartof Industrial Health, 2015, Vol.53(6), pp.505-510
issn 0019-8366
1880-8026
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4667040
source PubMed (Medline); J-STAGE Free; MEDLINE; EZB Electronic Journals Library; PubMed Central Open Access
subjects Agriculture - instrumentation
Analysis
Animals
Barns
Cattle
Cattle barn
Electric wire
Electric wiring
Electric Wiring - standards
Electrical fire
Materials Testing
Mode of load current
Original
Safety
Temperature
Thermal characteristics
Thermal Conductivity
Thermal properties
Time Factors
title Analysis of thermal characteristics of electrical wiring for load groups in cattle barns
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T16%3A53%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Analysis%20of%20thermal%20characteristics%20of%20electrical%20wiring%20for%20load%20groups%20in%20cattle%20barns&rft.jtitle=Industrial%20Health&rft.au=KIM,%20Doo%20Hyun&rft.date=2015&rft.volume=53&rft.issue=6&rft.spage=505&rft.epage=510&rft.pages=505-510&rft.issn=0019-8366&rft.eissn=1880-8026&rft_id=info:doi/10.2486/indhealth.2014-0235&rft_dat=%3Cgale_pubme%3EA446532940%3C/gale_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/26118855&rft_galeid=A446532940&rfr_iscdi=true