Artificial aortic valve dysfunction due to pannus and thrombus - different methods of cardiac surgical management
Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pann...
Gespeichert in:
Veröffentlicht in: | Kardiochirurgia i torakochirurgia polska 2015-09, Vol.12 (3), p.199-203 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 203 |
---|---|
container_issue | 3 |
container_start_page | 199 |
container_title | Kardiochirurgia i torakochirurgia polska |
container_volume | 12 |
creator | Ostrowski, Stanisław Marcinkiewicz, Anna Kośmider, Anna Walczak, Andrzej Zwoliński, Radosław Jaszewski, Ryszard |
description | Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case.
The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs' surface was found. A biological aortic prosthesis was reimplanted without complications.
The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored.
Precise and modern diagnostic methods facilitated selection of the treatment method. However, the intraoperative view also seems to be crucial in individualizing the surgical approach. |
doi_str_mv | 10.5114/kitp.2015.54453 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4631909</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1751992926</sourcerecordid><originalsourceid>FETCH-LOGICAL-c421t-f13ae0c50f5797c01803e5d5c14421ce9ae879c071a627ded4d343781abd44693</originalsourceid><addsrcrecordid>eNpdkc9PFDEUxxsjEUTP3kwTL15m6euP6fRiQgiKCYkXODfd_tgtzrRLO7MJ_z1dQKKe-pr36ff15YPQJyArAcDPfsd5t6IExEpwLtgbdAKDkh2ngr5ttWTQCcHIMXpf6x0hYgAyvEPHtJeEUslP0P15mWOINpoRm9xqi_dm3HvsHmpYkp1jTtgtHs8Z70xKS8UmOTxvS57W7dJhF0PwxacZT37eZldxDtia4qKxuC5lE23LnkwyGz817AM6Cmas_uPLeYpuv1_eXFx1179-_Lw4v-4spzB3AZjxxAoShFTSEhgI88IJC7z1rVfGD1JZIsH0VDrvuGOcyQHM2nHeK3aKvj3n7pb15J1to4sZ9a7EyZQHnU3U_3ZS3OpN3mveM1DkEPD1JaDk-8XXWU-xWj-OJvm8VA1SgFJU0b6hX_5D7_JSUluvUQMMDRHQqLNnypZca_Hh9TNA9EGnPujUB536SWd78fnvHV75P_7YI_nqndE</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1781826351</pqid></control><display><type>article</type><title>Artificial aortic valve dysfunction due to pannus and thrombus - different methods of cardiac surgical management</title><source>DOAJ Directory of Open Access Journals</source><source>PubMed Central Open Access</source><source>PubMed Central</source><creator>Ostrowski, Stanisław ; Marcinkiewicz, Anna ; Kośmider, Anna ; Walczak, Andrzej ; Zwoliński, Radosław ; Jaszewski, Ryszard</creator><creatorcontrib>Ostrowski, Stanisław ; Marcinkiewicz, Anna ; Kośmider, Anna ; Walczak, Andrzej ; Zwoliński, Radosław ; Jaszewski, Ryszard</creatorcontrib><description>Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case.
The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs' surface was found. A biological aortic prosthesis was reimplanted without complications.
The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored.
Precise and modern diagnostic methods facilitated selection of the treatment method. However, the intraoperative view also seems to be crucial in individualizing the surgical approach.</description><identifier>ISSN: 1731-5530</identifier><identifier>EISSN: 1897-4252</identifier><identifier>DOI: 10.5114/kitp.2015.54453</identifier><identifier>PMID: 26702274</identifier><language>eng</language><publisher>Poland: Termedia Publishing House</publisher><subject>Original Paper</subject><ispartof>Kardiochirurgia i torakochirurgia polska, 2015-09, Vol.12 (3), p.199-203</ispartof><rights>Copyright Termedia Publishing House 2015</rights><rights>Copyright © 2015 Polish Society of Cardiothoracic Surgeons (Polskie Towarzystwo KardioTorakochirurgów) and the editors of the Polish Journal of Cardio-Thoracic Surgery (Kardiochirurgia i Torakochirurgia Polska) 2015</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c421t-f13ae0c50f5797c01803e5d5c14421ce9ae879c071a627ded4d343781abd44693</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4631909/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4631909/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,315,728,781,785,865,886,27929,27930,53796,53798</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26702274$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ostrowski, Stanisław</creatorcontrib><creatorcontrib>Marcinkiewicz, Anna</creatorcontrib><creatorcontrib>Kośmider, Anna</creatorcontrib><creatorcontrib>Walczak, Andrzej</creatorcontrib><creatorcontrib>Zwoliński, Radosław</creatorcontrib><creatorcontrib>Jaszewski, Ryszard</creatorcontrib><title>Artificial aortic valve dysfunction due to pannus and thrombus - different methods of cardiac surgical management</title><title>Kardiochirurgia i torakochirurgia polska</title><addtitle>Kardiochir Torakochirurgia Pol</addtitle><description>Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case.
The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs' surface was found. A biological aortic prosthesis was reimplanted without complications.
The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored.
Precise and modern diagnostic methods facilitated selection of the treatment method. However, the intraoperative view also seems to be crucial in individualizing the surgical approach.</description><subject>Original Paper</subject><issn>1731-5530</issn><issn>1897-4252</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNpdkc9PFDEUxxsjEUTP3kwTL15m6euP6fRiQgiKCYkXODfd_tgtzrRLO7MJ_z1dQKKe-pr36ff15YPQJyArAcDPfsd5t6IExEpwLtgbdAKDkh2ngr5ttWTQCcHIMXpf6x0hYgAyvEPHtJeEUslP0P15mWOINpoRm9xqi_dm3HvsHmpYkp1jTtgtHs8Z70xKS8UmOTxvS57W7dJhF0PwxacZT37eZldxDtia4qKxuC5lE23LnkwyGz817AM6Cmas_uPLeYpuv1_eXFx1179-_Lw4v-4spzB3AZjxxAoShFTSEhgI88IJC7z1rVfGD1JZIsH0VDrvuGOcyQHM2nHeK3aKvj3n7pb15J1to4sZ9a7EyZQHnU3U_3ZS3OpN3mveM1DkEPD1JaDk-8XXWU-xWj-OJvm8VA1SgFJU0b6hX_5D7_JSUluvUQMMDRHQqLNnypZca_Hh9TNA9EGnPujUB536SWd78fnvHV75P_7YI_nqndE</recordid><startdate>20150901</startdate><enddate>20150901</enddate><creator>Ostrowski, Stanisław</creator><creator>Marcinkiewicz, Anna</creator><creator>Kośmider, Anna</creator><creator>Walczak, Andrzej</creator><creator>Zwoliński, Radosław</creator><creator>Jaszewski, Ryszard</creator><general>Termedia Publishing House</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7T5</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>H94</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20150901</creationdate><title>Artificial aortic valve dysfunction due to pannus and thrombus - different methods of cardiac surgical management</title><author>Ostrowski, Stanisław ; Marcinkiewicz, Anna ; Kośmider, Anna ; Walczak, Andrzej ; Zwoliński, Radosław ; Jaszewski, Ryszard</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c421t-f13ae0c50f5797c01803e5d5c14421ce9ae879c071a627ded4d343781abd44693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Original Paper</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ostrowski, Stanisław</creatorcontrib><creatorcontrib>Marcinkiewicz, Anna</creatorcontrib><creatorcontrib>Kośmider, Anna</creatorcontrib><creatorcontrib>Walczak, Andrzej</creatorcontrib><creatorcontrib>Zwoliński, Radosław</creatorcontrib><creatorcontrib>Jaszewski, Ryszard</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Immunology Abstracts</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Access via ProQuest (Open Access)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Kardiochirurgia i torakochirurgia polska</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ostrowski, Stanisław</au><au>Marcinkiewicz, Anna</au><au>Kośmider, Anna</au><au>Walczak, Andrzej</au><au>Zwoliński, Radosław</au><au>Jaszewski, Ryszard</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Artificial aortic valve dysfunction due to pannus and thrombus - different methods of cardiac surgical management</atitle><jtitle>Kardiochirurgia i torakochirurgia polska</jtitle><addtitle>Kardiochir Torakochirurgia Pol</addtitle><date>2015-09-01</date><risdate>2015</risdate><volume>12</volume><issue>3</issue><spage>199</spage><epage>203</epage><pages>199-203</pages><issn>1731-5530</issn><eissn>1897-4252</eissn><abstract>Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case.
The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs' surface was found. A biological aortic prosthesis was reimplanted without complications.
The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored.
Precise and modern diagnostic methods facilitated selection of the treatment method. However, the intraoperative view also seems to be crucial in individualizing the surgical approach.</abstract><cop>Poland</cop><pub>Termedia Publishing House</pub><pmid>26702274</pmid><doi>10.5114/kitp.2015.54453</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1731-5530 |
ispartof | Kardiochirurgia i torakochirurgia polska, 2015-09, Vol.12 (3), p.199-203 |
issn | 1731-5530 1897-4252 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4631909 |
source | DOAJ Directory of Open Access Journals; PubMed Central Open Access; PubMed Central |
subjects | Original Paper |
title | Artificial aortic valve dysfunction due to pannus and thrombus - different methods of cardiac surgical management |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-16T01%3A26%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Artificial%20aortic%20valve%20dysfunction%20due%20to%20pannus%20and%20thrombus%20-%20different%20methods%20of%20cardiac%20surgical%20management&rft.jtitle=Kardiochirurgia%20i%20torakochirurgia%20polska&rft.au=Ostrowski,%20Stanis%C5%82aw&rft.date=2015-09-01&rft.volume=12&rft.issue=3&rft.spage=199&rft.epage=203&rft.pages=199-203&rft.issn=1731-5530&rft.eissn=1897-4252&rft_id=info:doi/10.5114/kitp.2015.54453&rft_dat=%3Cproquest_pubme%3E1751992926%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1781826351&rft_id=info:pmid/26702274&rfr_iscdi=true |