Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study
Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position. Prospective observational study in consecutive adults admitted to a French intensive care...
Gespeichert in:
Veröffentlicht in: | Medicine (Baltimore) 2015-09, Vol.94 (39), p.e1557-e1557 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | e1557 |
---|---|
container_issue | 39 |
container_start_page | e1557 |
container_title | Medicine (Baltimore) |
container_volume | 94 |
creator | Jacq, Gwenaëlle Gritti, Karine Carré, Cécile Fleury, Nadège Lang, Annie Courau-Courtois, Josette Bedos, Jean-Pierre Legriel, Stephane |
description | Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position. Prospective observational study in consecutive adults admitted to a French intensive care unit in 2009 to 2011 and fulfilling our inclusion criteria. Four combinations (B–E) of transducer level, catheter access site, and patient position were compared with a reference combination (A) (Apatient supine with all catheters in the same plane and a single transducer level (M) for zero point reference (Z) aligned on the phlebostatic axis; B45° head-of-bed elevation with M and Z aligned on the phlebostatic axis; C45° head-of-bed elevation with M aligned on the catheter access site and Z on the phlebostatic axis; D45° head-of-bed elevation with M and Z aligned on the catheter access site; and E45° head-of-bed elevation with M aligned on the phlebostatic axis and Z on the catheter access site). We included 103 patients, 68 men and 35 women, with a median age of 69 years (interquartile range [IQR], 56–78); at inclusion, 91 (88.3%) received mechanical ventilation, 45 (43.7%) catecholamines, and 66 (64.1%) sedation. The IAPM access site was femoral in 49 (47.6%) and radial in 54 (52.4%) patients, with 62 of 103 (60.2%) catheters on the right side. Measured absolute mean arterial pressure values were significantly higher with 3 study combinations (C–E) than with the reference combination (A). After adjustment, the differences versus A (median, 83 [IQR, 74–92] mm Hg) remained significant for D (median, 91 [IQR, 85–100] mm Hg, P |
doi_str_mv | 10.1097/MD.0000000000001557 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4616871</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1718909118</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3554-579780b9e347d785de9e4363291ddb8fae7f38a0eb383927ca8b51261ec42c643</originalsourceid><addsrcrecordid>eNpdkc1uEzEUhS1ERdPCEyChWbKZ4n-PWSBFKW0jNSoSsLY8njuNwRmn9kyqvD0uKVWLN5Z8z_l87IPQe4LPCNbq0-r8DD9bRAj1Cs2IYLIWWvLXaIYxFbXSih-jk5x_FQ1TlL9Bx1RyKiUVM3S3ip0NfvSQq9hXy2Fns99BNU8jJG9D9S1BzlOCahUHP8bkh9vKD9UiFY-zIeyrZSgqWwjDmD9X8-KIeQtufMDctBnSrgzjUFjfx6nbv0VHvQ0Z3j3up-jnxdcfi6v6-uZyuZhf144JwWtRcje41cC46lQjOtDAmWRUk65rm96C6lljMbSsYZoqZ5tWECoJOE6d5OwUfTlwt1O7gc6VeMkGs01-Y9PeROvNy8ng1-Y27gyXRDaKFMDHR0CKdxPk0Wx8dhCCHSBO2RBFGo01IU2RsoPUlbfnBP3TNQSbh7LM6tz8X1ZxfXie8Mnzr50i4AfBfQyljvw7TPeQzBpsGNd_eeWXaE0LDmsscF1OKGd_ACijoTc</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1718909118</pqid></control><display><type>article</type><title>Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study</title><source>Wolters Kluwer Open Health</source><source>MEDLINE</source><source>DOAJ Directory of Open Access Journals</source><source>IngentaConnect Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Jacq, Gwenaëlle ; Gritti, Karine ; Carré, Cécile ; Fleury, Nadège ; Lang, Annie ; Courau-Courtois, Josette ; Bedos, Jean-Pierre ; Legriel, Stephane</creator><creatorcontrib>Jacq, Gwenaëlle ; Gritti, Karine ; Carré, Cécile ; Fleury, Nadège ; Lang, Annie ; Courau-Courtois, Josette ; Bedos, Jean-Pierre ; Legriel, Stephane</creatorcontrib><description>Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position. Prospective observational study in consecutive adults admitted to a French intensive care unit in 2009 to 2011 and fulfilling our inclusion criteria. Four combinations (B–E) of transducer level, catheter access site, and patient position were compared with a reference combination (A) (Apatient supine with all catheters in the same plane and a single transducer level (M) for zero point reference (Z) aligned on the phlebostatic axis; B45° head-of-bed elevation with M and Z aligned on the phlebostatic axis; C45° head-of-bed elevation with M aligned on the catheter access site and Z on the phlebostatic axis; D45° head-of-bed elevation with M and Z aligned on the catheter access site; and E45° head-of-bed elevation with M aligned on the phlebostatic axis and Z on the catheter access site). We included 103 patients, 68 men and 35 women, with a median age of 69 years (interquartile range [IQR], 56–78); at inclusion, 91 (88.3%) received mechanical ventilation, 45 (43.7%) catecholamines, and 66 (64.1%) sedation. The IAPM access site was femoral in 49 (47.6%) and radial in 54 (52.4%) patients, with 62 of 103 (60.2%) catheters on the right side. Measured absolute mean arterial pressure values were significantly higher with 3 study combinations (C–E) than with the reference combination (A). After adjustment, the differences versus A (median, 83 [IQR, 74–92] mm Hg) remained significant for D (median, 91 [IQR, 85–100] mm Hg, P < 0.001) and E (median, 88 [IQR, 77–99] mm Hg, P < 0.001). The difference versus A was not significant for B (median, 85 [IQR, 76–94] mm Hg, P = 0.21) or C (median, 90 [IQR, 84–100] mm Hg, P = 0.006). Several modalities used for zeroing and/or transducer leveling during IAPM may result in statistically and clinically significant overestimation of measured mean arterial pressure values. For patients in the 45° head-of-bed elevation position, aligning the Z on the phlebostatic axis provides values that are not significantly different from those obtained using the reference supine modality.</description><identifier>ISSN: 0025-7974</identifier><identifier>EISSN: 1536-5964</identifier><identifier>DOI: 10.1097/MD.0000000000001557</identifier><identifier>PMID: 26426625</identifier><language>eng</language><publisher>United States: Wolters Kluwer Health, Inc. All rights reserved</publisher><subject>Aged ; Arterial Pressure ; Blood Pressure Determination - methods ; Critical Illness - therapy ; Female ; Humans ; Intensive Care Units ; Male ; Middle Aged ; Monitoring, Physiologic - methods ; Prospective Studies ; Quality Improvement Study</subject><ispartof>Medicine (Baltimore), 2015-09, Vol.94 (39), p.e1557-e1557</ispartof><rights>Wolters Kluwer Health, Inc. All rights reserved.</rights><rights>Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. 2015</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c3554-579780b9e347d785de9e4363291ddb8fae7f38a0eb383927ca8b51261ec42c643</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4616871/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4616871/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,860,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26426625$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Jacq, Gwenaëlle</creatorcontrib><creatorcontrib>Gritti, Karine</creatorcontrib><creatorcontrib>Carré, Cécile</creatorcontrib><creatorcontrib>Fleury, Nadège</creatorcontrib><creatorcontrib>Lang, Annie</creatorcontrib><creatorcontrib>Courau-Courtois, Josette</creatorcontrib><creatorcontrib>Bedos, Jean-Pierre</creatorcontrib><creatorcontrib>Legriel, Stephane</creatorcontrib><title>Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study</title><title>Medicine (Baltimore)</title><addtitle>Medicine (Baltimore)</addtitle><description>Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position. Prospective observational study in consecutive adults admitted to a French intensive care unit in 2009 to 2011 and fulfilling our inclusion criteria. Four combinations (B–E) of transducer level, catheter access site, and patient position were compared with a reference combination (A) (Apatient supine with all catheters in the same plane and a single transducer level (M) for zero point reference (Z) aligned on the phlebostatic axis; B45° head-of-bed elevation with M and Z aligned on the phlebostatic axis; C45° head-of-bed elevation with M aligned on the catheter access site and Z on the phlebostatic axis; D45° head-of-bed elevation with M and Z aligned on the catheter access site; and E45° head-of-bed elevation with M aligned on the phlebostatic axis and Z on the catheter access site). We included 103 patients, 68 men and 35 women, with a median age of 69 years (interquartile range [IQR], 56–78); at inclusion, 91 (88.3%) received mechanical ventilation, 45 (43.7%) catecholamines, and 66 (64.1%) sedation. The IAPM access site was femoral in 49 (47.6%) and radial in 54 (52.4%) patients, with 62 of 103 (60.2%) catheters on the right side. Measured absolute mean arterial pressure values were significantly higher with 3 study combinations (C–E) than with the reference combination (A). After adjustment, the differences versus A (median, 83 [IQR, 74–92] mm Hg) remained significant for D (median, 91 [IQR, 85–100] mm Hg, P < 0.001) and E (median, 88 [IQR, 77–99] mm Hg, P < 0.001). The difference versus A was not significant for B (median, 85 [IQR, 76–94] mm Hg, P = 0.21) or C (median, 90 [IQR, 84–100] mm Hg, P = 0.006). Several modalities used for zeroing and/or transducer leveling during IAPM may result in statistically and clinically significant overestimation of measured mean arterial pressure values. For patients in the 45° head-of-bed elevation position, aligning the Z on the phlebostatic axis provides values that are not significantly different from those obtained using the reference supine modality.</description><subject>Aged</subject><subject>Arterial Pressure</subject><subject>Blood Pressure Determination - methods</subject><subject>Critical Illness - therapy</subject><subject>Female</subject><subject>Humans</subject><subject>Intensive Care Units</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Monitoring, Physiologic - methods</subject><subject>Prospective Studies</subject><subject>Quality Improvement Study</subject><issn>0025-7974</issn><issn>1536-5964</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdkc1uEzEUhS1ERdPCEyChWbKZ4n-PWSBFKW0jNSoSsLY8njuNwRmn9kyqvD0uKVWLN5Z8z_l87IPQe4LPCNbq0-r8DD9bRAj1Cs2IYLIWWvLXaIYxFbXSih-jk5x_FQ1TlL9Bx1RyKiUVM3S3ip0NfvSQq9hXy2Fns99BNU8jJG9D9S1BzlOCahUHP8bkh9vKD9UiFY-zIeyrZSgqWwjDmD9X8-KIeQtufMDctBnSrgzjUFjfx6nbv0VHvQ0Z3j3up-jnxdcfi6v6-uZyuZhf144JwWtRcje41cC46lQjOtDAmWRUk65rm96C6lljMbSsYZoqZ5tWECoJOE6d5OwUfTlwt1O7gc6VeMkGs01-Y9PeROvNy8ng1-Y27gyXRDaKFMDHR0CKdxPk0Wx8dhCCHSBO2RBFGo01IU2RsoPUlbfnBP3TNQSbh7LM6tz8X1ZxfXie8Mnzr50i4AfBfQyljvw7TPeQzBpsGNd_eeWXaE0LDmsscF1OKGd_ACijoTc</recordid><startdate>20150901</startdate><enddate>20150901</enddate><creator>Jacq, Gwenaëlle</creator><creator>Gritti, Karine</creator><creator>Carré, Cécile</creator><creator>Fleury, Nadège</creator><creator>Lang, Annie</creator><creator>Courau-Courtois, Josette</creator><creator>Bedos, Jean-Pierre</creator><creator>Legriel, Stephane</creator><general>Wolters Kluwer Health, Inc. All rights reserved</general><general>Wolters Kluwer Health</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20150901</creationdate><title>Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study</title><author>Jacq, Gwenaëlle ; Gritti, Karine ; Carré, Cécile ; Fleury, Nadège ; Lang, Annie ; Courau-Courtois, Josette ; Bedos, Jean-Pierre ; Legriel, Stephane</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3554-579780b9e347d785de9e4363291ddb8fae7f38a0eb383927ca8b51261ec42c643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Aged</topic><topic>Arterial Pressure</topic><topic>Blood Pressure Determination - methods</topic><topic>Critical Illness - therapy</topic><topic>Female</topic><topic>Humans</topic><topic>Intensive Care Units</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Monitoring, Physiologic - methods</topic><topic>Prospective Studies</topic><topic>Quality Improvement Study</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jacq, Gwenaëlle</creatorcontrib><creatorcontrib>Gritti, Karine</creatorcontrib><creatorcontrib>Carré, Cécile</creatorcontrib><creatorcontrib>Fleury, Nadège</creatorcontrib><creatorcontrib>Lang, Annie</creatorcontrib><creatorcontrib>Courau-Courtois, Josette</creatorcontrib><creatorcontrib>Bedos, Jean-Pierre</creatorcontrib><creatorcontrib>Legriel, Stephane</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Medicine (Baltimore)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jacq, Gwenaëlle</au><au>Gritti, Karine</au><au>Carré, Cécile</au><au>Fleury, Nadège</au><au>Lang, Annie</au><au>Courau-Courtois, Josette</au><au>Bedos, Jean-Pierre</au><au>Legriel, Stephane</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study</atitle><jtitle>Medicine (Baltimore)</jtitle><addtitle>Medicine (Baltimore)</addtitle><date>2015-09-01</date><risdate>2015</risdate><volume>94</volume><issue>39</issue><spage>e1557</spage><epage>e1557</epage><pages>e1557-e1557</pages><issn>0025-7974</issn><eissn>1536-5964</eissn><abstract>Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position. Prospective observational study in consecutive adults admitted to a French intensive care unit in 2009 to 2011 and fulfilling our inclusion criteria. Four combinations (B–E) of transducer level, catheter access site, and patient position were compared with a reference combination (A) (Apatient supine with all catheters in the same plane and a single transducer level (M) for zero point reference (Z) aligned on the phlebostatic axis; B45° head-of-bed elevation with M and Z aligned on the phlebostatic axis; C45° head-of-bed elevation with M aligned on the catheter access site and Z on the phlebostatic axis; D45° head-of-bed elevation with M and Z aligned on the catheter access site; and E45° head-of-bed elevation with M aligned on the phlebostatic axis and Z on the catheter access site). We included 103 patients, 68 men and 35 women, with a median age of 69 years (interquartile range [IQR], 56–78); at inclusion, 91 (88.3%) received mechanical ventilation, 45 (43.7%) catecholamines, and 66 (64.1%) sedation. The IAPM access site was femoral in 49 (47.6%) and radial in 54 (52.4%) patients, with 62 of 103 (60.2%) catheters on the right side. Measured absolute mean arterial pressure values were significantly higher with 3 study combinations (C–E) than with the reference combination (A). After adjustment, the differences versus A (median, 83 [IQR, 74–92] mm Hg) remained significant for D (median, 91 [IQR, 85–100] mm Hg, P < 0.001) and E (median, 88 [IQR, 77–99] mm Hg, P < 0.001). The difference versus A was not significant for B (median, 85 [IQR, 76–94] mm Hg, P = 0.21) or C (median, 90 [IQR, 84–100] mm Hg, P = 0.006). Several modalities used for zeroing and/or transducer leveling during IAPM may result in statistically and clinically significant overestimation of measured mean arterial pressure values. For patients in the 45° head-of-bed elevation position, aligning the Z on the phlebostatic axis provides values that are not significantly different from those obtained using the reference supine modality.</abstract><cop>United States</cop><pub>Wolters Kluwer Health, Inc. All rights reserved</pub><pmid>26426625</pmid><doi>10.1097/MD.0000000000001557</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0025-7974 |
ispartof | Medicine (Baltimore), 2015-09, Vol.94 (39), p.e1557-e1557 |
issn | 0025-7974 1536-5964 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4616871 |
source | Wolters Kluwer Open Health; MEDLINE; DOAJ Directory of Open Access Journals; IngentaConnect Open Access Journals; EZB-FREE-00999 freely available EZB journals; PubMed Central; Alma/SFX Local Collection |
subjects | Aged Arterial Pressure Blood Pressure Determination - methods Critical Illness - therapy Female Humans Intensive Care Units Male Middle Aged Monitoring, Physiologic - methods Prospective Studies Quality Improvement Study |
title | Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T21%3A57%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Modalities%20of%20Invasive%20Arterial%20Pressure%20Monitoring%20in%20Critically%20Ill%20Patients:%20A%20Prospective%20Observational%20Study&rft.jtitle=Medicine%20(Baltimore)&rft.au=Jacq,%20Gwena%C3%ABlle&rft.date=2015-09-01&rft.volume=94&rft.issue=39&rft.spage=e1557&rft.epage=e1557&rft.pages=e1557-e1557&rft.issn=0025-7974&rft.eissn=1536-5964&rft_id=info:doi/10.1097/MD.0000000000001557&rft_dat=%3Cproquest_pubme%3E1718909118%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1718909118&rft_id=info:pmid/26426625&rfr_iscdi=true |