Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study

Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position. Prospective observational study in consecutive adults admitted to a French intensive care...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medicine (Baltimore) 2015-09, Vol.94 (39), p.e1557-e1557
Hauptverfasser: Jacq, Gwenaëlle, Gritti, Karine, Carré, Cécile, Fleury, Nadège, Lang, Annie, Courau-Courtois, Josette, Bedos, Jean-Pierre, Legriel, Stephane
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page e1557
container_issue 39
container_start_page e1557
container_title Medicine (Baltimore)
container_volume 94
creator Jacq, Gwenaëlle
Gritti, Karine
Carré, Cécile
Fleury, Nadège
Lang, Annie
Courau-Courtois, Josette
Bedos, Jean-Pierre
Legriel, Stephane
description Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position. Prospective observational study in consecutive adults admitted to a French intensive care unit in 2009 to 2011 and fulfilling our inclusion criteria. Four combinations (B–E) of transducer level, catheter access site, and patient position were compared with a reference combination (A) (Apatient supine with all catheters in the same plane and a single transducer level (M) for zero point reference (Z) aligned on the phlebostatic axis; B45° head-of-bed elevation with M and Z aligned on the phlebostatic axis; C45° head-of-bed elevation with M aligned on the catheter access site and Z on the phlebostatic axis; D45° head-of-bed elevation with M and Z aligned on the catheter access site; and E45° head-of-bed elevation with M aligned on the phlebostatic axis and Z on the catheter access site). We included 103 patients, 68 men and 35 women, with a median age of 69 years (interquartile range [IQR], 56–78); at inclusion, 91 (88.3%) received mechanical ventilation, 45 (43.7%) catecholamines, and 66 (64.1%) sedation. The IAPM access site was femoral in 49 (47.6%) and radial in 54 (52.4%) patients, with 62 of 103 (60.2%) catheters on the right side. Measured absolute mean arterial pressure values were significantly higher with 3 study combinations (C–E) than with the reference combination (A). After adjustment, the differences versus A (median, 83 [IQR, 74–92] mm Hg) remained significant for D (median, 91 [IQR, 85–100] mm Hg, P 
doi_str_mv 10.1097/MD.0000000000001557
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4616871</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1718909118</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3554-579780b9e347d785de9e4363291ddb8fae7f38a0eb383927ca8b51261ec42c643</originalsourceid><addsrcrecordid>eNpdkc1uEzEUhS1ERdPCEyChWbKZ4n-PWSBFKW0jNSoSsLY8njuNwRmn9kyqvD0uKVWLN5Z8z_l87IPQe4LPCNbq0-r8DD9bRAj1Cs2IYLIWWvLXaIYxFbXSih-jk5x_FQ1TlL9Bx1RyKiUVM3S3ip0NfvSQq9hXy2Fns99BNU8jJG9D9S1BzlOCahUHP8bkh9vKD9UiFY-zIeyrZSgqWwjDmD9X8-KIeQtufMDctBnSrgzjUFjfx6nbv0VHvQ0Z3j3up-jnxdcfi6v6-uZyuZhf144JwWtRcje41cC46lQjOtDAmWRUk65rm96C6lljMbSsYZoqZ5tWECoJOE6d5OwUfTlwt1O7gc6VeMkGs01-Y9PeROvNy8ng1-Y27gyXRDaKFMDHR0CKdxPk0Wx8dhCCHSBO2RBFGo01IU2RsoPUlbfnBP3TNQSbh7LM6tz8X1ZxfXie8Mnzr50i4AfBfQyljvw7TPeQzBpsGNd_eeWXaE0LDmsscF1OKGd_ACijoTc</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1718909118</pqid></control><display><type>article</type><title>Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study</title><source>Wolters Kluwer Open Health</source><source>MEDLINE</source><source>DOAJ Directory of Open Access Journals</source><source>IngentaConnect Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Jacq, Gwenaëlle ; Gritti, Karine ; Carré, Cécile ; Fleury, Nadège ; Lang, Annie ; Courau-Courtois, Josette ; Bedos, Jean-Pierre ; Legriel, Stephane</creator><creatorcontrib>Jacq, Gwenaëlle ; Gritti, Karine ; Carré, Cécile ; Fleury, Nadège ; Lang, Annie ; Courau-Courtois, Josette ; Bedos, Jean-Pierre ; Legriel, Stephane</creatorcontrib><description>Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position. Prospective observational study in consecutive adults admitted to a French intensive care unit in 2009 to 2011 and fulfilling our inclusion criteria. Four combinations (B–E) of transducer level, catheter access site, and patient position were compared with a reference combination (A) (Apatient supine with all catheters in the same plane and a single transducer level (M) for zero point reference (Z) aligned on the phlebostatic axis; B45° head-of-bed elevation with M and Z aligned on the phlebostatic axis; C45° head-of-bed elevation with M aligned on the catheter access site and Z on the phlebostatic axis; D45° head-of-bed elevation with M and Z aligned on the catheter access site; and E45° head-of-bed elevation with M aligned on the phlebostatic axis and Z on the catheter access site). We included 103 patients, 68 men and 35 women, with a median age of 69 years (interquartile range [IQR], 56–78); at inclusion, 91 (88.3%) received mechanical ventilation, 45 (43.7%) catecholamines, and 66 (64.1%) sedation. The IAPM access site was femoral in 49 (47.6%) and radial in 54 (52.4%) patients, with 62 of 103 (60.2%) catheters on the right side. Measured absolute mean arterial pressure values were significantly higher with 3 study combinations (C–E) than with the reference combination (A). After adjustment, the differences versus A (median, 83 [IQR, 74–92] mm Hg) remained significant for D (median, 91 [IQR, 85–100] mm Hg, P &lt; 0.001) and E (median, 88 [IQR, 77–99] mm Hg, P &lt; 0.001). The difference versus A was not significant for B (median, 85 [IQR, 76–94] mm Hg, P = 0.21) or C (median, 90 [IQR, 84–100] mm Hg, P = 0.006). Several modalities used for zeroing and/or transducer leveling during IAPM may result in statistically and clinically significant overestimation of measured mean arterial pressure values. For patients in the 45° head-of-bed elevation position, aligning the Z on the phlebostatic axis provides values that are not significantly different from those obtained using the reference supine modality.</description><identifier>ISSN: 0025-7974</identifier><identifier>EISSN: 1536-5964</identifier><identifier>DOI: 10.1097/MD.0000000000001557</identifier><identifier>PMID: 26426625</identifier><language>eng</language><publisher>United States: Wolters Kluwer Health, Inc. All rights reserved</publisher><subject>Aged ; Arterial Pressure ; Blood Pressure Determination - methods ; Critical Illness - therapy ; Female ; Humans ; Intensive Care Units ; Male ; Middle Aged ; Monitoring, Physiologic - methods ; Prospective Studies ; Quality Improvement Study</subject><ispartof>Medicine (Baltimore), 2015-09, Vol.94 (39), p.e1557-e1557</ispartof><rights>Wolters Kluwer Health, Inc. All rights reserved.</rights><rights>Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. 2015</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c3554-579780b9e347d785de9e4363291ddb8fae7f38a0eb383927ca8b51261ec42c643</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4616871/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4616871/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,860,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26426625$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Jacq, Gwenaëlle</creatorcontrib><creatorcontrib>Gritti, Karine</creatorcontrib><creatorcontrib>Carré, Cécile</creatorcontrib><creatorcontrib>Fleury, Nadège</creatorcontrib><creatorcontrib>Lang, Annie</creatorcontrib><creatorcontrib>Courau-Courtois, Josette</creatorcontrib><creatorcontrib>Bedos, Jean-Pierre</creatorcontrib><creatorcontrib>Legriel, Stephane</creatorcontrib><title>Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study</title><title>Medicine (Baltimore)</title><addtitle>Medicine (Baltimore)</addtitle><description>Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position. Prospective observational study in consecutive adults admitted to a French intensive care unit in 2009 to 2011 and fulfilling our inclusion criteria. Four combinations (B–E) of transducer level, catheter access site, and patient position were compared with a reference combination (A) (Apatient supine with all catheters in the same plane and a single transducer level (M) for zero point reference (Z) aligned on the phlebostatic axis; B45° head-of-bed elevation with M and Z aligned on the phlebostatic axis; C45° head-of-bed elevation with M aligned on the catheter access site and Z on the phlebostatic axis; D45° head-of-bed elevation with M and Z aligned on the catheter access site; and E45° head-of-bed elevation with M aligned on the phlebostatic axis and Z on the catheter access site). We included 103 patients, 68 men and 35 women, with a median age of 69 years (interquartile range [IQR], 56–78); at inclusion, 91 (88.3%) received mechanical ventilation, 45 (43.7%) catecholamines, and 66 (64.1%) sedation. The IAPM access site was femoral in 49 (47.6%) and radial in 54 (52.4%) patients, with 62 of 103 (60.2%) catheters on the right side. Measured absolute mean arterial pressure values were significantly higher with 3 study combinations (C–E) than with the reference combination (A). After adjustment, the differences versus A (median, 83 [IQR, 74–92] mm Hg) remained significant for D (median, 91 [IQR, 85–100] mm Hg, P &lt; 0.001) and E (median, 88 [IQR, 77–99] mm Hg, P &lt; 0.001). The difference versus A was not significant for B (median, 85 [IQR, 76–94] mm Hg, P = 0.21) or C (median, 90 [IQR, 84–100] mm Hg, P = 0.006). Several modalities used for zeroing and/or transducer leveling during IAPM may result in statistically and clinically significant overestimation of measured mean arterial pressure values. For patients in the 45° head-of-bed elevation position, aligning the Z on the phlebostatic axis provides values that are not significantly different from those obtained using the reference supine modality.</description><subject>Aged</subject><subject>Arterial Pressure</subject><subject>Blood Pressure Determination - methods</subject><subject>Critical Illness - therapy</subject><subject>Female</subject><subject>Humans</subject><subject>Intensive Care Units</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Monitoring, Physiologic - methods</subject><subject>Prospective Studies</subject><subject>Quality Improvement Study</subject><issn>0025-7974</issn><issn>1536-5964</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdkc1uEzEUhS1ERdPCEyChWbKZ4n-PWSBFKW0jNSoSsLY8njuNwRmn9kyqvD0uKVWLN5Z8z_l87IPQe4LPCNbq0-r8DD9bRAj1Cs2IYLIWWvLXaIYxFbXSih-jk5x_FQ1TlL9Bx1RyKiUVM3S3ip0NfvSQq9hXy2Fns99BNU8jJG9D9S1BzlOCahUHP8bkh9vKD9UiFY-zIeyrZSgqWwjDmD9X8-KIeQtufMDctBnSrgzjUFjfx6nbv0VHvQ0Z3j3up-jnxdcfi6v6-uZyuZhf144JwWtRcje41cC46lQjOtDAmWRUk65rm96C6lljMbSsYZoqZ5tWECoJOE6d5OwUfTlwt1O7gc6VeMkGs01-Y9PeROvNy8ng1-Y27gyXRDaKFMDHR0CKdxPk0Wx8dhCCHSBO2RBFGo01IU2RsoPUlbfnBP3TNQSbh7LM6tz8X1ZxfXie8Mnzr50i4AfBfQyljvw7TPeQzBpsGNd_eeWXaE0LDmsscF1OKGd_ACijoTc</recordid><startdate>20150901</startdate><enddate>20150901</enddate><creator>Jacq, Gwenaëlle</creator><creator>Gritti, Karine</creator><creator>Carré, Cécile</creator><creator>Fleury, Nadège</creator><creator>Lang, Annie</creator><creator>Courau-Courtois, Josette</creator><creator>Bedos, Jean-Pierre</creator><creator>Legriel, Stephane</creator><general>Wolters Kluwer Health, Inc. All rights reserved</general><general>Wolters Kluwer Health</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20150901</creationdate><title>Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study</title><author>Jacq, Gwenaëlle ; Gritti, Karine ; Carré, Cécile ; Fleury, Nadège ; Lang, Annie ; Courau-Courtois, Josette ; Bedos, Jean-Pierre ; Legriel, Stephane</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3554-579780b9e347d785de9e4363291ddb8fae7f38a0eb383927ca8b51261ec42c643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Aged</topic><topic>Arterial Pressure</topic><topic>Blood Pressure Determination - methods</topic><topic>Critical Illness - therapy</topic><topic>Female</topic><topic>Humans</topic><topic>Intensive Care Units</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Monitoring, Physiologic - methods</topic><topic>Prospective Studies</topic><topic>Quality Improvement Study</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jacq, Gwenaëlle</creatorcontrib><creatorcontrib>Gritti, Karine</creatorcontrib><creatorcontrib>Carré, Cécile</creatorcontrib><creatorcontrib>Fleury, Nadège</creatorcontrib><creatorcontrib>Lang, Annie</creatorcontrib><creatorcontrib>Courau-Courtois, Josette</creatorcontrib><creatorcontrib>Bedos, Jean-Pierre</creatorcontrib><creatorcontrib>Legriel, Stephane</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Medicine (Baltimore)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jacq, Gwenaëlle</au><au>Gritti, Karine</au><au>Carré, Cécile</au><au>Fleury, Nadège</au><au>Lang, Annie</au><au>Courau-Courtois, Josette</au><au>Bedos, Jean-Pierre</au><au>Legriel, Stephane</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study</atitle><jtitle>Medicine (Baltimore)</jtitle><addtitle>Medicine (Baltimore)</addtitle><date>2015-09-01</date><risdate>2015</risdate><volume>94</volume><issue>39</issue><spage>e1557</spage><epage>e1557</epage><pages>e1557-e1557</pages><issn>0025-7974</issn><eissn>1536-5964</eissn><abstract>Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position. Prospective observational study in consecutive adults admitted to a French intensive care unit in 2009 to 2011 and fulfilling our inclusion criteria. Four combinations (B–E) of transducer level, catheter access site, and patient position were compared with a reference combination (A) (Apatient supine with all catheters in the same plane and a single transducer level (M) for zero point reference (Z) aligned on the phlebostatic axis; B45° head-of-bed elevation with M and Z aligned on the phlebostatic axis; C45° head-of-bed elevation with M aligned on the catheter access site and Z on the phlebostatic axis; D45° head-of-bed elevation with M and Z aligned on the catheter access site; and E45° head-of-bed elevation with M aligned on the phlebostatic axis and Z on the catheter access site). We included 103 patients, 68 men and 35 women, with a median age of 69 years (interquartile range [IQR], 56–78); at inclusion, 91 (88.3%) received mechanical ventilation, 45 (43.7%) catecholamines, and 66 (64.1%) sedation. The IAPM access site was femoral in 49 (47.6%) and radial in 54 (52.4%) patients, with 62 of 103 (60.2%) catheters on the right side. Measured absolute mean arterial pressure values were significantly higher with 3 study combinations (C–E) than with the reference combination (A). After adjustment, the differences versus A (median, 83 [IQR, 74–92] mm Hg) remained significant for D (median, 91 [IQR, 85–100] mm Hg, P &lt; 0.001) and E (median, 88 [IQR, 77–99] mm Hg, P &lt; 0.001). The difference versus A was not significant for B (median, 85 [IQR, 76–94] mm Hg, P = 0.21) or C (median, 90 [IQR, 84–100] mm Hg, P = 0.006). Several modalities used for zeroing and/or transducer leveling during IAPM may result in statistically and clinically significant overestimation of measured mean arterial pressure values. For patients in the 45° head-of-bed elevation position, aligning the Z on the phlebostatic axis provides values that are not significantly different from those obtained using the reference supine modality.</abstract><cop>United States</cop><pub>Wolters Kluwer Health, Inc. All rights reserved</pub><pmid>26426625</pmid><doi>10.1097/MD.0000000000001557</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0025-7974
ispartof Medicine (Baltimore), 2015-09, Vol.94 (39), p.e1557-e1557
issn 0025-7974
1536-5964
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4616871
source Wolters Kluwer Open Health; MEDLINE; DOAJ Directory of Open Access Journals; IngentaConnect Open Access Journals; EZB-FREE-00999 freely available EZB journals; PubMed Central; Alma/SFX Local Collection
subjects Aged
Arterial Pressure
Blood Pressure Determination - methods
Critical Illness - therapy
Female
Humans
Intensive Care Units
Male
Middle Aged
Monitoring, Physiologic - methods
Prospective Studies
Quality Improvement Study
title Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T21%3A57%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Modalities%20of%20Invasive%20Arterial%20Pressure%20Monitoring%20in%20Critically%20Ill%20Patients:%20A%20Prospective%20Observational%20Study&rft.jtitle=Medicine%20(Baltimore)&rft.au=Jacq,%20Gwena%C3%ABlle&rft.date=2015-09-01&rft.volume=94&rft.issue=39&rft.spage=e1557&rft.epage=e1557&rft.pages=e1557-e1557&rft.issn=0025-7974&rft.eissn=1536-5964&rft_id=info:doi/10.1097/MD.0000000000001557&rft_dat=%3Cproquest_pubme%3E1718909118%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1718909118&rft_id=info:pmid/26426625&rfr_iscdi=true