Assessment of hepatic VX2 tumors of rabbits with second harmonic imaging under high and low acoustic pressures
AIM: To investigate the possible clinical application value of second harmonic imaging under low acoustic pressure.METIBODS: Six New Zealand rabbits, averaging 2.7±0.4kg, were selected and operated upon to construct hepatic VX2 tumor carder model. Hepatic VX2 tumors were imaged with B mode Ultrasono...
Gespeichert in:
Veröffentlicht in: | World journal of gastroenterology : WJG 2003-08, Vol.9 (8), p.1679-1682 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1682 |
---|---|
container_issue | 8 |
container_start_page | 1679 |
container_title | World journal of gastroenterology : WJG |
container_volume | 9 |
creator | Du, Wen-Hua Yang, Wei-Xiao Wang, Xiang Xiong, Xiu-Qin Zhou, Yi Li, Tao |
description | AIM: To investigate the possible clinical application value of second harmonic imaging under low acoustic pressure.METIBODS: Six New Zealand rabbits, averaging 2.7±0.4kg, were selected and operated upon to construct hepatic VX2 tumor carder model. Hepatic VX2 tumors were imaged with B mode Ultrasonography (US), and second harmonic imaging (SHI) under high mechanic index (1.6) and low mechanic index (0.1). Echo agent was intravenously injected through ear vein at a dose of 0.01 mL/kg under B mode US and high HI SHI, and 0.05 mL/kg under low HI SHI, and then the venous channel was cleaned with sterilized saline.All the images were recorded by magnetic optics (MO), and they were analyzed further by at least two independent experienced sonographers.RESULTS: Totally 6 hypoechoic and 3 hyperechoic lesions were found in the six carder rabbits with a mean size about2.1±0.4 under B mode ultrasound, they were oval or round in shape with a clear outline or a hypoechoic halo at the margin of the lesions. Contrast agent could not change the echogenicity of the lesions under B mode US and SHI under high acoustic pressure. However, it could greatly increase the real time visualization sensitivity of the lesions with SHIunder low acoustic pressure.CONCLUSION: Our results suggest that contrast enhanced SHI with low HI and a bubble non-destructive method would be much more helpful than conventional SHI in our future clinical applications. |
doi_str_mv | 10.3748/wjg.v9.i8.1679 |
format | Article |
fullrecord | <record><control><sourceid>wanfang_jour_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4611523</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>8407182</cqvip_id><wanfj_id>wjg200308007</wanfj_id><sourcerecordid>wjg200308007</sourcerecordid><originalsourceid>FETCH-LOGICAL-c441t-9c32a731f64a4cfaa1f21858312025290892d6ee93a083f65b83f4bc4cba5d53</originalsourceid><addsrcrecordid>eNpVUcuK3DAQFCEhOzvJNcegwLI3T_SyLV0Cy5IXLOSyhNxEW5ZtTWxpVrJnyN9HZoY8Lt2gKlVXdyH0hpIdr4V8f9r3u6PaObmjVa2eoQ1jVBVMCvIcbSghdaE4q6_QdUp7QhjnJXuJrihTVGZ0g_xdSjalyfoZhw4P9gCzM_j7D4bnZQoxra8RmsbNCZ_cPOBkTfAtHiBOwWeqm6B3vseLb23Eg-sHDBkfwwmDCUta5Q4xz1hyeYVedDAm-_rSt-jx08fH-y_Fw7fPX-_vHgojBJ0LZTiDmtOuEiBMB0A7RmUpOWWElUwRqVhbWas4EMm7qmxyFY0RpoGyLfkWfTjLHpZmsq3J20UY9SFms_GXDuD0_4h3g-7DUYuK0jJfaYtuzgIn8B34Xu_DEn12rPPBGSGcyHzbTLu9zInhabFp1pNLxo4jeJtX1zUXivFyNbQ7E00MKUXb_fFCiV6DXHX1UWkn9Rpk_vD23w3-0i_JZcK7i-IQfP-UE9ANmJ-dG63O6ddUMv4beuOnfw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73492355</pqid></control><display><type>article</type><title>Assessment of hepatic VX2 tumors of rabbits with second harmonic imaging under high and low acoustic pressures</title><source>MEDLINE</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Du, Wen-Hua ; Yang, Wei-Xiao ; Wang, Xiang ; Xiong, Xiu-Qin ; Zhou, Yi ; Li, Tao</creator><creatorcontrib>Du, Wen-Hua ; Yang, Wei-Xiao ; Wang, Xiang ; Xiong, Xiu-Qin ; Zhou, Yi ; Li, Tao</creatorcontrib><description>AIM: To investigate the possible clinical application value of second harmonic imaging under low acoustic pressure.METIBODS: Six New Zealand rabbits, averaging 2.7±0.4kg, were selected and operated upon to construct hepatic VX2 tumor carder model. Hepatic VX2 tumors were imaged with B mode Ultrasonography (US), and second harmonic imaging (SHI) under high mechanic index (1.6) and low mechanic index (0.1). Echo agent was intravenously injected through ear vein at a dose of 0.01 mL/kg under B mode US and high HI SHI, and 0.05 mL/kg under low HI SHI, and then the venous channel was cleaned with sterilized saline.All the images were recorded by magnetic optics (MO), and they were analyzed further by at least two independent experienced sonographers.RESULTS: Totally 6 hypoechoic and 3 hyperechoic lesions were found in the six carder rabbits with a mean size about2.1±0.4 under B mode ultrasound, they were oval or round in shape with a clear outline or a hypoechoic halo at the margin of the lesions. Contrast agent could not change the echogenicity of the lesions under B mode US and SHI under high acoustic pressure. However, it could greatly increase the real time visualization sensitivity of the lesions with SHIunder low acoustic pressure.CONCLUSION: Our results suggest that contrast enhanced SHI with low HI and a bubble non-destructive method would be much more helpful than conventional SHI in our future clinical applications.</description><identifier>ISSN: 1007-9327</identifier><identifier>EISSN: 2219-2840</identifier><identifier>DOI: 10.3748/wjg.v9.i8.1679</identifier><identifier>PMID: 12918100</identifier><language>eng</language><publisher>United States: Department of Ultrasonography, Daping Hospital and Research Institute of Surgery, the Third Military Medical University, Chongqing 400042, China</publisher><subject>Air ; Animals ; Liver Cancer ; Liver Neoplasms, Experimental - diagnostic imaging ; Microspheres ; Rabbits ; Ultrasonography - methods ; 低声压 ; 次谐波成像 ; 肝肿瘤 ; 超声检查</subject><ispartof>World journal of gastroenterology : WJG, 2003-08, Vol.9 (8), p.1679-1682</ispartof><rights>Copyright © Wanfang Data Co. Ltd. All Rights Reserved.</rights><rights>The Author(s) 2003. Published by Baishideng Publishing Group Inc. All rights reserved. 2003</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c441t-9c32a731f64a4cfaa1f21858312025290892d6ee93a083f65b83f4bc4cba5d53</citedby><cites>FETCH-LOGICAL-c441t-9c32a731f64a4cfaa1f21858312025290892d6ee93a083f65b83f4bc4cba5d53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/84123X/84123X.jpg</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4611523/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4611523/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,723,776,780,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12918100$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Du, Wen-Hua</creatorcontrib><creatorcontrib>Yang, Wei-Xiao</creatorcontrib><creatorcontrib>Wang, Xiang</creatorcontrib><creatorcontrib>Xiong, Xiu-Qin</creatorcontrib><creatorcontrib>Zhou, Yi</creatorcontrib><creatorcontrib>Li, Tao</creatorcontrib><title>Assessment of hepatic VX2 tumors of rabbits with second harmonic imaging under high and low acoustic pressures</title><title>World journal of gastroenterology : WJG</title><addtitle>World Journal of Gastroenterology</addtitle><description>AIM: To investigate the possible clinical application value of second harmonic imaging under low acoustic pressure.METIBODS: Six New Zealand rabbits, averaging 2.7±0.4kg, were selected and operated upon to construct hepatic VX2 tumor carder model. Hepatic VX2 tumors were imaged with B mode Ultrasonography (US), and second harmonic imaging (SHI) under high mechanic index (1.6) and low mechanic index (0.1). Echo agent was intravenously injected through ear vein at a dose of 0.01 mL/kg under B mode US and high HI SHI, and 0.05 mL/kg under low HI SHI, and then the venous channel was cleaned with sterilized saline.All the images were recorded by magnetic optics (MO), and they were analyzed further by at least two independent experienced sonographers.RESULTS: Totally 6 hypoechoic and 3 hyperechoic lesions were found in the six carder rabbits with a mean size about2.1±0.4 under B mode ultrasound, they were oval or round in shape with a clear outline or a hypoechoic halo at the margin of the lesions. Contrast agent could not change the echogenicity of the lesions under B mode US and SHI under high acoustic pressure. However, it could greatly increase the real time visualization sensitivity of the lesions with SHIunder low acoustic pressure.CONCLUSION: Our results suggest that contrast enhanced SHI with low HI and a bubble non-destructive method would be much more helpful than conventional SHI in our future clinical applications.</description><subject>Air</subject><subject>Animals</subject><subject>Liver Cancer</subject><subject>Liver Neoplasms, Experimental - diagnostic imaging</subject><subject>Microspheres</subject><subject>Rabbits</subject><subject>Ultrasonography - methods</subject><subject>低声压</subject><subject>次谐波成像</subject><subject>肝肿瘤</subject><subject>超声检查</subject><issn>1007-9327</issn><issn>2219-2840</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVUcuK3DAQFCEhOzvJNcegwLI3T_SyLV0Cy5IXLOSyhNxEW5ZtTWxpVrJnyN9HZoY8Lt2gKlVXdyH0hpIdr4V8f9r3u6PaObmjVa2eoQ1jVBVMCvIcbSghdaE4q6_QdUp7QhjnJXuJrihTVGZ0g_xdSjalyfoZhw4P9gCzM_j7D4bnZQoxra8RmsbNCZ_cPOBkTfAtHiBOwWeqm6B3vseLb23Eg-sHDBkfwwmDCUta5Q4xz1hyeYVedDAm-_rSt-jx08fH-y_Fw7fPX-_vHgojBJ0LZTiDmtOuEiBMB0A7RmUpOWWElUwRqVhbWas4EMm7qmxyFY0RpoGyLfkWfTjLHpZmsq3J20UY9SFms_GXDuD0_4h3g-7DUYuK0jJfaYtuzgIn8B34Xu_DEn12rPPBGSGcyHzbTLu9zInhabFp1pNLxo4jeJtX1zUXivFyNbQ7E00MKUXb_fFCiV6DXHX1UWkn9Rpk_vD23w3-0i_JZcK7i-IQfP-UE9ANmJ-dG63O6ddUMv4beuOnfw</recordid><startdate>20030801</startdate><enddate>20030801</enddate><creator>Du, Wen-Hua</creator><creator>Yang, Wei-Xiao</creator><creator>Wang, Xiang</creator><creator>Xiong, Xiu-Qin</creator><creator>Zhou, Yi</creator><creator>Li, Tao</creator><general>Department of Ultrasonography, Daping Hospital and Research Institute of Surgery, the Third Military Medical University, Chongqing 400042, China</general><general>Baishideng Publishing Group Inc</general><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>W91</scope><scope>~WA</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>2B.</scope><scope>4A8</scope><scope>92I</scope><scope>93N</scope><scope>PSX</scope><scope>TCJ</scope><scope>5PM</scope></search><sort><creationdate>20030801</creationdate><title>Assessment of hepatic VX2 tumors of rabbits with second harmonic imaging under high and low acoustic pressures</title><author>Du, Wen-Hua ; Yang, Wei-Xiao ; Wang, Xiang ; Xiong, Xiu-Qin ; Zhou, Yi ; Li, Tao</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c441t-9c32a731f64a4cfaa1f21858312025290892d6ee93a083f65b83f4bc4cba5d53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Air</topic><topic>Animals</topic><topic>Liver Cancer</topic><topic>Liver Neoplasms, Experimental - diagnostic imaging</topic><topic>Microspheres</topic><topic>Rabbits</topic><topic>Ultrasonography - methods</topic><topic>低声压</topic><topic>次谐波成像</topic><topic>肝肿瘤</topic><topic>超声检查</topic><toplevel>online_resources</toplevel><creatorcontrib>Du, Wen-Hua</creatorcontrib><creatorcontrib>Yang, Wei-Xiao</creatorcontrib><creatorcontrib>Wang, Xiang</creatorcontrib><creatorcontrib>Xiong, Xiu-Qin</creatorcontrib><creatorcontrib>Zhou, Yi</creatorcontrib><creatorcontrib>Li, Tao</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库-医药卫生</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Wanfang Data Journals - Hong Kong</collection><collection>WANFANG Data Centre</collection><collection>Wanfang Data Journals</collection><collection>万方数据期刊 - 香港版</collection><collection>China Online Journals (COJ)</collection><collection>China Online Journals (COJ)</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>World journal of gastroenterology : WJG</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Du, Wen-Hua</au><au>Yang, Wei-Xiao</au><au>Wang, Xiang</au><au>Xiong, Xiu-Qin</au><au>Zhou, Yi</au><au>Li, Tao</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Assessment of hepatic VX2 tumors of rabbits with second harmonic imaging under high and low acoustic pressures</atitle><jtitle>World journal of gastroenterology : WJG</jtitle><addtitle>World Journal of Gastroenterology</addtitle><date>2003-08-01</date><risdate>2003</risdate><volume>9</volume><issue>8</issue><spage>1679</spage><epage>1682</epage><pages>1679-1682</pages><issn>1007-9327</issn><eissn>2219-2840</eissn><abstract>AIM: To investigate the possible clinical application value of second harmonic imaging under low acoustic pressure.METIBODS: Six New Zealand rabbits, averaging 2.7±0.4kg, were selected and operated upon to construct hepatic VX2 tumor carder model. Hepatic VX2 tumors were imaged with B mode Ultrasonography (US), and second harmonic imaging (SHI) under high mechanic index (1.6) and low mechanic index (0.1). Echo agent was intravenously injected through ear vein at a dose of 0.01 mL/kg under B mode US and high HI SHI, and 0.05 mL/kg under low HI SHI, and then the venous channel was cleaned with sterilized saline.All the images were recorded by magnetic optics (MO), and they were analyzed further by at least two independent experienced sonographers.RESULTS: Totally 6 hypoechoic and 3 hyperechoic lesions were found in the six carder rabbits with a mean size about2.1±0.4 under B mode ultrasound, they were oval or round in shape with a clear outline or a hypoechoic halo at the margin of the lesions. Contrast agent could not change the echogenicity of the lesions under B mode US and SHI under high acoustic pressure. However, it could greatly increase the real time visualization sensitivity of the lesions with SHIunder low acoustic pressure.CONCLUSION: Our results suggest that contrast enhanced SHI with low HI and a bubble non-destructive method would be much more helpful than conventional SHI in our future clinical applications.</abstract><cop>United States</cop><pub>Department of Ultrasonography, Daping Hospital and Research Institute of Surgery, the Third Military Medical University, Chongqing 400042, China</pub><pmid>12918100</pmid><doi>10.3748/wjg.v9.i8.1679</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1007-9327 |
ispartof | World journal of gastroenterology : WJG, 2003-08, Vol.9 (8), p.1679-1682 |
issn | 1007-9327 2219-2840 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4611523 |
source | MEDLINE; PubMed Central; Alma/SFX Local Collection |
subjects | Air Animals Liver Cancer Liver Neoplasms, Experimental - diagnostic imaging Microspheres Rabbits Ultrasonography - methods 低声压 次谐波成像 肝肿瘤 超声检查 |
title | Assessment of hepatic VX2 tumors of rabbits with second harmonic imaging under high and low acoustic pressures |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T01%3A15%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wanfang_jour_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Assessment%20of%20hepatic%20VX2%20tumors%20of%20rabbits%20with%20second%20harmonic%20imaging%20under%20high%20and%20low%20acoustic%20pressures&rft.jtitle=World%20journal%20of%20gastroenterology%20:%20WJG&rft.au=Du,%20Wen-Hua&rft.date=2003-08-01&rft.volume=9&rft.issue=8&rft.spage=1679&rft.epage=1682&rft.pages=1679-1682&rft.issn=1007-9327&rft.eissn=2219-2840&rft_id=info:doi/10.3748/wjg.v9.i8.1679&rft_dat=%3Cwanfang_jour_pubme%3Ewjg200308007%3C/wanfang_jour_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73492355&rft_id=info:pmid/12918100&rft_cqvip_id=8407182&rft_wanfj_id=wjg200308007&rfr_iscdi=true |