Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection
Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present stu...
Gespeichert in:
Veröffentlicht in: | Journal of international oral health 2015-09, Vol.7 (9), p.22-24 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 24 |
---|---|
container_issue | 9 |
container_start_page | 22 |
container_title | Journal of international oral health |
container_volume | 7 |
creator | Kamble, Suresh S Khandeparker, Rakshit Vijay Somasundaram, P Raghav, Shweta Babaji, Rashmi P Varghese, T Joju |
description | Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present study was aimed to evaluate the dimensional accuracy of elastomeric impression materials when treated with different disinfectants; autoclave, chemical, and microwave method.
The impression materials used for the study were, dentsply aquasil (addition silicone polyvinylsiloxane syringe and putty), zetaplus (condensation silicone putty and light body), and impregum penta soft (polyether). All impressions were made according to manufacturer's instructions. Dimensional changes were measured before and after different disinfection procedures.
Dentsply aquasil showed smallest dimensional change (-0.0046%) and impregum penta soft highest linear dimensional changes (-0.026%). All the tested elastomeric impression materials showed some degree of dimensional changes.
The present study showed that all the disinfection procedures produce minor dimensional changes of impression material. However, it was within American Dental Association specification. Hence, steam autoclaving and microwave method can be used as an alternative method to chemical sterilization as an effective method. |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4589713</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3831271851</sourcerecordid><originalsourceid>FETCH-LOGICAL-p1393-c7b185cbc2f28a58bcc1d7f2e710910d643adeb90299b64458e821ad683d65293</originalsourceid><addsrcrecordid>eNpdkd9KwzAUxosoTuZeQQLeeOGgSf_mRhjd1MGGN_O6nKanNqNtatJu7D18YFM3Rc1NTr58_L5zkjPnyuVROKUR5-enOvJZPHImxmxdu0KX-X5w6YxY6HtBSOmV85GougUNndwhWeyg6m2pGqIKMpc1NsYeoCIzIXoN4jDoiwpMp2rUUpBl3Wo0g4msobMSVIbsS2zIRqMVcrKXXUlmfadEBTu8J2sptNp_ldDkJCmxlsImzKWRTYFiSL92LgoLwslpHzuvj4tN8jxdvTwtk9lq2lKPe1MRZTQORCZYwWII4kwImkcFw4i6nLq5HRJyzLjLOM9CO3mMMaOQh7GXhwHj3th5OHLbPqsxF9h0Gqq01bIGfUgVyPTvTSPL9E3tUoviEfUs4O4E0Oq9R9OltTQCqwoaVL1JaUS5z9gx6_afdat6bd92cDHXEuMgtK6b3x39tPL9Yd4nHP-Wfw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1720458856</pqid></control><display><type>article</type><title>Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection</title><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>Kamble, Suresh S ; Khandeparker, Rakshit Vijay ; Somasundaram, P ; Raghav, Shweta ; Babaji, Rashmi P ; Varghese, T Joju</creator><creatorcontrib>Kamble, Suresh S ; Khandeparker, Rakshit Vijay ; Somasundaram, P ; Raghav, Shweta ; Babaji, Rashmi P ; Varghese, T Joju</creatorcontrib><description>Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present study was aimed to evaluate the dimensional accuracy of elastomeric impression materials when treated with different disinfectants; autoclave, chemical, and microwave method.
The impression materials used for the study were, dentsply aquasil (addition silicone polyvinylsiloxane syringe and putty), zetaplus (condensation silicone putty and light body), and impregum penta soft (polyether). All impressions were made according to manufacturer's instructions. Dimensional changes were measured before and after different disinfection procedures.
Dentsply aquasil showed smallest dimensional change (-0.0046%) and impregum penta soft highest linear dimensional changes (-0.026%). All the tested elastomeric impression materials showed some degree of dimensional changes.
The present study showed that all the disinfection procedures produce minor dimensional changes of impression material. However, it was within American Dental Association specification. Hence, steam autoclaving and microwave method can be used as an alternative method to chemical sterilization as an effective method.</description><identifier>ISSN: 0976-7428</identifier><identifier>EISSN: 0976-1799</identifier><identifier>PMID: 26435611</identifier><language>eng</language><publisher>India: Medknow Publications & Media Pvt. Ltd</publisher><subject>Comparative analysis ; Dentistry ; Disinfection & disinfectants ; Molds & molding ; Original Research ; Teeth</subject><ispartof>Journal of international oral health, 2015-09, Vol.7 (9), p.22-24</ispartof><rights>Copyright International Society of Preventive & Community Dentistry Sep 2015</rights><rights>Copyright: © Journal of International Oral Health 2015</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4589713/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4589713/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,724,777,781,882,53772,53774</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26435611$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kamble, Suresh S</creatorcontrib><creatorcontrib>Khandeparker, Rakshit Vijay</creatorcontrib><creatorcontrib>Somasundaram, P</creatorcontrib><creatorcontrib>Raghav, Shweta</creatorcontrib><creatorcontrib>Babaji, Rashmi P</creatorcontrib><creatorcontrib>Varghese, T Joju</creatorcontrib><title>Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection</title><title>Journal of international oral health</title><addtitle>J Int Oral Health</addtitle><description>Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present study was aimed to evaluate the dimensional accuracy of elastomeric impression materials when treated with different disinfectants; autoclave, chemical, and microwave method.
The impression materials used for the study were, dentsply aquasil (addition silicone polyvinylsiloxane syringe and putty), zetaplus (condensation silicone putty and light body), and impregum penta soft (polyether). All impressions were made according to manufacturer's instructions. Dimensional changes were measured before and after different disinfection procedures.
Dentsply aquasil showed smallest dimensional change (-0.0046%) and impregum penta soft highest linear dimensional changes (-0.026%). All the tested elastomeric impression materials showed some degree of dimensional changes.
The present study showed that all the disinfection procedures produce minor dimensional changes of impression material. However, it was within American Dental Association specification. Hence, steam autoclaving and microwave method can be used as an alternative method to chemical sterilization as an effective method.</description><subject>Comparative analysis</subject><subject>Dentistry</subject><subject>Disinfection & disinfectants</subject><subject>Molds & molding</subject><subject>Original Research</subject><subject>Teeth</subject><issn>0976-7428</issn><issn>0976-1799</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNpdkd9KwzAUxosoTuZeQQLeeOGgSf_mRhjd1MGGN_O6nKanNqNtatJu7D18YFM3Rc1NTr58_L5zkjPnyuVROKUR5-enOvJZPHImxmxdu0KX-X5w6YxY6HtBSOmV85GougUNndwhWeyg6m2pGqIKMpc1NsYeoCIzIXoN4jDoiwpMp2rUUpBl3Wo0g4msobMSVIbsS2zIRqMVcrKXXUlmfadEBTu8J2sptNp_ldDkJCmxlsImzKWRTYFiSL92LgoLwslpHzuvj4tN8jxdvTwtk9lq2lKPe1MRZTQORCZYwWII4kwImkcFw4i6nLq5HRJyzLjLOM9CO3mMMaOQh7GXhwHj3th5OHLbPqsxF9h0Gqq01bIGfUgVyPTvTSPL9E3tUoviEfUs4O4E0Oq9R9OltTQCqwoaVL1JaUS5z9gx6_afdat6bd92cDHXEuMgtK6b3x39tPL9Yd4nHP-Wfw</recordid><startdate>201509</startdate><enddate>201509</enddate><creator>Kamble, Suresh S</creator><creator>Khandeparker, Rakshit Vijay</creator><creator>Somasundaram, P</creator><creator>Raghav, Shweta</creator><creator>Babaji, Rashmi P</creator><creator>Varghese, T Joju</creator><general>Medknow Publications & Media Pvt. Ltd</general><general>Dentmedpub Research and Printing Co</general><scope>NPM</scope><scope>04Q</scope><scope>04T</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8C1</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M7P</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>201509</creationdate><title>Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection</title><author>Kamble, Suresh S ; Khandeparker, Rakshit Vijay ; Somasundaram, P ; Raghav, Shweta ; Babaji, Rashmi P ; Varghese, T Joju</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p1393-c7b185cbc2f28a58bcc1d7f2e710910d643adeb90299b64458e821ad683d65293</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Comparative analysis</topic><topic>Dentistry</topic><topic>Disinfection & disinfectants</topic><topic>Molds & molding</topic><topic>Original Research</topic><topic>Teeth</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kamble, Suresh S</creatorcontrib><creatorcontrib>Khandeparker, Rakshit Vijay</creatorcontrib><creatorcontrib>Somasundaram, P</creatorcontrib><creatorcontrib>Raghav, Shweta</creatorcontrib><creatorcontrib>Babaji, Rashmi P</creatorcontrib><creatorcontrib>Varghese, T Joju</creatorcontrib><collection>PubMed</collection><collection>India Database</collection><collection>India Database: Health & Medicine</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Public Health Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Biological Science Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of international oral health</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kamble, Suresh S</au><au>Khandeparker, Rakshit Vijay</au><au>Somasundaram, P</au><au>Raghav, Shweta</au><au>Babaji, Rashmi P</au><au>Varghese, T Joju</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection</atitle><jtitle>Journal of international oral health</jtitle><addtitle>J Int Oral Health</addtitle><date>2015-09</date><risdate>2015</risdate><volume>7</volume><issue>9</issue><spage>22</spage><epage>24</epage><pages>22-24</pages><issn>0976-7428</issn><eissn>0976-1799</eissn><abstract>Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present study was aimed to evaluate the dimensional accuracy of elastomeric impression materials when treated with different disinfectants; autoclave, chemical, and microwave method.
The impression materials used for the study were, dentsply aquasil (addition silicone polyvinylsiloxane syringe and putty), zetaplus (condensation silicone putty and light body), and impregum penta soft (polyether). All impressions were made according to manufacturer's instructions. Dimensional changes were measured before and after different disinfection procedures.
Dentsply aquasil showed smallest dimensional change (-0.0046%) and impregum penta soft highest linear dimensional changes (-0.026%). All the tested elastomeric impression materials showed some degree of dimensional changes.
The present study showed that all the disinfection procedures produce minor dimensional changes of impression material. However, it was within American Dental Association specification. Hence, steam autoclaving and microwave method can be used as an alternative method to chemical sterilization as an effective method.</abstract><cop>India</cop><pub>Medknow Publications & Media Pvt. Ltd</pub><pmid>26435611</pmid><tpages>3</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0976-7428 |
ispartof | Journal of international oral health, 2015-09, Vol.7 (9), p.22-24 |
issn | 0976-7428 0976-1799 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4589713 |
source | EZB-FREE-00999 freely available EZB journals; PubMed Central |
subjects | Comparative analysis Dentistry Disinfection & disinfectants Molds & molding Original Research Teeth |
title | Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T15%3A56%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparative%20Evaluation%20of%20Dimensional%20Accuracy%20of%20Elastomeric%20Impression%20Materials%20when%20Treated%20with%20Autoclave,%20Microwave,%20and%20Chemical%20Disinfection&rft.jtitle=Journal%20of%20international%20oral%20health&rft.au=Kamble,%20Suresh%20S&rft.date=2015-09&rft.volume=7&rft.issue=9&rft.spage=22&rft.epage=24&rft.pages=22-24&rft.issn=0976-7428&rft.eissn=0976-1799&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E3831271851%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1720458856&rft_id=info:pmid/26435611&rfr_iscdi=true |