Dosimetric Characteristics of a Two-Dimensional Diode Array Detector Irradiated with Passively Scattered Proton Beams
To evaluate the dosimetric characteristics of a two-dimensional (2D) diode array detector irradiated with passively scattered proton beams. A diode array detector, MapCHECK (Model 1175, Sun Nuclear, Melbourne, FL, USA) was characterized in passive-scattered proton beams. The relative sensitivity of...
Gespeichert in:
Veröffentlicht in: | Cancers 2015-07, Vol.7 (3), p.1425-1435 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1435 |
---|---|
container_issue | 3 |
container_start_page | 1425 |
container_title | Cancers |
container_volume | 7 |
creator | Liengsawangwong, Praimakorn Sahoo, Nanayan Ding, Xiaoning Lii, MingFwu Gillin, Michale T Zhu, Xiaorong Ronald |
description | To evaluate the dosimetric characteristics of a two-dimensional (2D) diode array detector irradiated with passively scattered proton beams.
A diode array detector, MapCHECK (Model 1175, Sun Nuclear, Melbourne, FL, USA) was characterized in passive-scattered proton beams. The relative sensitivity of the diodes and absolute dose calibration were determined using a 250 MeV beam. The pristine Bragg curves (PBCs) measured by MapCHECK diodes were compared with those of an ion chamber using a range shift method. The water-equivalent thickness (WET) of the diode array detector's intrinsic buildup also was determined. The inverse square dependence, linearity, and other proton dosimetric quantities measured by MapCHECK were also compared with those of the ion chambers. The change in the absolute dose response of the MapCHECK as a function of accumulated radiation dose was used as an indicator of radiation damage to the diodes. 2D dose distribution with and without the compensator were measured and compared with the treatment planning system (TPS) calculations.
The WET of the MapCHECK diode's buildup was determined to be 1.7 cm. The MapCHECK-measured PBC were virtually identical to those measured by a parallel-plate ion chamber for 160, 180, and 250 MeV proton beams. The inverse square results of the MapCHECK were within ±0.4% of the ion chamber results. The linearity of MapCHECK results was within 1% of those from the ion chamber as measured in the range between 10 and 300 MU. All other dosimetric quantities were within 1.3% of the ion chamber results. The 2D dose distributions for non-clinical fields without compensator and the patient treatment fields with the compensator were consistent with the TPS results. The absolute dose response of the MapCHECK was changed by 7.4% after an accumulated dose increased by 170 Gy.
The MapCHECK is a convenient and useful tool for 2D dose distribution measurements using passively scattered proton beams. Variations in MapCHECK's dose response with increasing levels of total accumulated radiation dose should be carefully monitored. |
doi_str_mv | 10.3390/cancers7030844 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4586777</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3835558051</sourcerecordid><originalsourceid>FETCH-LOGICAL-c418t-72440826ea439aef62d52fb0ef5532b0b1a99cecf506f9258ab9efd4f75ae0da3</originalsourceid><addsrcrecordid>eNpdkc1rHSEUxaW0NCHNtssidNPNpI46Om4K6Xv9CAQaaLqWO861zzAzpuokvP--hqQh6d145f48eM8h5G3LToQw7KODxWHKmgnWS_mCHHKmeaOUkS-f9AfkOOcrVkuIViv9mhxwxZVkXB6SdRtzmLGk4OhmBwlcwRRyCS7T6CnQy9vYbCux5BAXmOg2xBHpaUqwp1ss6EpM9KxexwAFR3obyo5eQM7hBqc9_emgVMU6uEixxIV-RpjzG_LKw5Tx-OE8Ir--frncfG_Of3w725yeN062fWk0l5L1XCFIYQC94mPH_cDQd53gAxtaMMah8x1T3vCuh8GgH6XXHSAbQRyRT_e61-sw4-hwKQkme53CDGlvIwT7fLKEnf0db6zseqW1rgIfHgRS_LNiLnYO2eE0wYJxzbat3ivTa9NX9P1_6FVcU7XsjuKtEXURXqmTe8qlmHNC__iZltm7UO3zUOuDd09XeMT_RSj-Ar_zoSM</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1721938262</pqid></control><display><type>article</type><title>Dosimetric Characteristics of a Two-Dimensional Diode Array Detector Irradiated with Passively Scattered Proton Beams</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central Open Access</source><source>MDPI - Multidisciplinary Digital Publishing Institute</source><source>PubMed Central</source><creator>Liengsawangwong, Praimakorn ; Sahoo, Nanayan ; Ding, Xiaoning ; Lii, MingFwu ; Gillin, Michale T ; Zhu, Xiaorong Ronald</creator><creatorcontrib>Liengsawangwong, Praimakorn ; Sahoo, Nanayan ; Ding, Xiaoning ; Lii, MingFwu ; Gillin, Michale T ; Zhu, Xiaorong Ronald</creatorcontrib><description>To evaluate the dosimetric characteristics of a two-dimensional (2D) diode array detector irradiated with passively scattered proton beams.
A diode array detector, MapCHECK (Model 1175, Sun Nuclear, Melbourne, FL, USA) was characterized in passive-scattered proton beams. The relative sensitivity of the diodes and absolute dose calibration were determined using a 250 MeV beam. The pristine Bragg curves (PBCs) measured by MapCHECK diodes were compared with those of an ion chamber using a range shift method. The water-equivalent thickness (WET) of the diode array detector's intrinsic buildup also was determined. The inverse square dependence, linearity, and other proton dosimetric quantities measured by MapCHECK were also compared with those of the ion chambers. The change in the absolute dose response of the MapCHECK as a function of accumulated radiation dose was used as an indicator of radiation damage to the diodes. 2D dose distribution with and without the compensator were measured and compared with the treatment planning system (TPS) calculations.
The WET of the MapCHECK diode's buildup was determined to be 1.7 cm. The MapCHECK-measured PBC were virtually identical to those measured by a parallel-plate ion chamber for 160, 180, and 250 MeV proton beams. The inverse square results of the MapCHECK were within ±0.4% of the ion chamber results. The linearity of MapCHECK results was within 1% of those from the ion chamber as measured in the range between 10 and 300 MU. All other dosimetric quantities were within 1.3% of the ion chamber results. The 2D dose distributions for non-clinical fields without compensator and the patient treatment fields with the compensator were consistent with the TPS results. The absolute dose response of the MapCHECK was changed by 7.4% after an accumulated dose increased by 170 Gy.
The MapCHECK is a convenient and useful tool for 2D dose distribution measurements using passively scattered proton beams. Variations in MapCHECK's dose response with increasing levels of total accumulated radiation dose should be carefully monitored.</description><identifier>ISSN: 2072-6694</identifier><identifier>EISSN: 2072-6694</identifier><identifier>DOI: 10.3390/cancers7030844</identifier><identifier>PMID: 26264024</identifier><language>eng</language><publisher>Switzerland: MDPI AG</publisher><subject>Oncology ; Radiation therapy</subject><ispartof>Cancers, 2015-07, Vol.7 (3), p.1425-1435</ispartof><rights>Copyright MDPI AG 2015</rights><rights>2015 by the authors; licensee MDPI, Basel, Switzerland. 2015</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c418t-72440826ea439aef62d52fb0ef5532b0b1a99cecf506f9258ab9efd4f75ae0da3</citedby><cites>FETCH-LOGICAL-c418t-72440826ea439aef62d52fb0ef5532b0b1a99cecf506f9258ab9efd4f75ae0da3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4586777/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4586777/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,315,729,782,786,887,27931,27932,53798,53800</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26264024$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Liengsawangwong, Praimakorn</creatorcontrib><creatorcontrib>Sahoo, Nanayan</creatorcontrib><creatorcontrib>Ding, Xiaoning</creatorcontrib><creatorcontrib>Lii, MingFwu</creatorcontrib><creatorcontrib>Gillin, Michale T</creatorcontrib><creatorcontrib>Zhu, Xiaorong Ronald</creatorcontrib><title>Dosimetric Characteristics of a Two-Dimensional Diode Array Detector Irradiated with Passively Scattered Proton Beams</title><title>Cancers</title><addtitle>Cancers (Basel)</addtitle><description>To evaluate the dosimetric characteristics of a two-dimensional (2D) diode array detector irradiated with passively scattered proton beams.
A diode array detector, MapCHECK (Model 1175, Sun Nuclear, Melbourne, FL, USA) was characterized in passive-scattered proton beams. The relative sensitivity of the diodes and absolute dose calibration were determined using a 250 MeV beam. The pristine Bragg curves (PBCs) measured by MapCHECK diodes were compared with those of an ion chamber using a range shift method. The water-equivalent thickness (WET) of the diode array detector's intrinsic buildup also was determined. The inverse square dependence, linearity, and other proton dosimetric quantities measured by MapCHECK were also compared with those of the ion chambers. The change in the absolute dose response of the MapCHECK as a function of accumulated radiation dose was used as an indicator of radiation damage to the diodes. 2D dose distribution with and without the compensator were measured and compared with the treatment planning system (TPS) calculations.
The WET of the MapCHECK diode's buildup was determined to be 1.7 cm. The MapCHECK-measured PBC were virtually identical to those measured by a parallel-plate ion chamber for 160, 180, and 250 MeV proton beams. The inverse square results of the MapCHECK were within ±0.4% of the ion chamber results. The linearity of MapCHECK results was within 1% of those from the ion chamber as measured in the range between 10 and 300 MU. All other dosimetric quantities were within 1.3% of the ion chamber results. The 2D dose distributions for non-clinical fields without compensator and the patient treatment fields with the compensator were consistent with the TPS results. The absolute dose response of the MapCHECK was changed by 7.4% after an accumulated dose increased by 170 Gy.
The MapCHECK is a convenient and useful tool for 2D dose distribution measurements using passively scattered proton beams. Variations in MapCHECK's dose response with increasing levels of total accumulated radiation dose should be carefully monitored.</description><subject>Oncology</subject><subject>Radiation therapy</subject><issn>2072-6694</issn><issn>2072-6694</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>8G5</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><sourceid>GUQSH</sourceid><sourceid>M2O</sourceid><recordid>eNpdkc1rHSEUxaW0NCHNtssidNPNpI46Om4K6Xv9CAQaaLqWO861zzAzpuokvP--hqQh6d145f48eM8h5G3LToQw7KODxWHKmgnWS_mCHHKmeaOUkS-f9AfkOOcrVkuIViv9mhxwxZVkXB6SdRtzmLGk4OhmBwlcwRRyCS7T6CnQy9vYbCux5BAXmOg2xBHpaUqwp1ss6EpM9KxexwAFR3obyo5eQM7hBqc9_emgVMU6uEixxIV-RpjzG_LKw5Tx-OE8Ir--frncfG_Of3w725yeN062fWk0l5L1XCFIYQC94mPH_cDQd53gAxtaMMah8x1T3vCuh8GgH6XXHSAbQRyRT_e61-sw4-hwKQkme53CDGlvIwT7fLKEnf0db6zseqW1rgIfHgRS_LNiLnYO2eE0wYJxzbat3ivTa9NX9P1_6FVcU7XsjuKtEXURXqmTe8qlmHNC__iZltm7UO3zUOuDd09XeMT_RSj-Ar_zoSM</recordid><startdate>20150730</startdate><enddate>20150730</enddate><creator>Liengsawangwong, Praimakorn</creator><creator>Sahoo, Nanayan</creator><creator>Ding, Xiaoning</creator><creator>Lii, MingFwu</creator><creator>Gillin, Michale T</creator><creator>Zhu, Xiaorong Ronald</creator><general>MDPI AG</general><general>MDPI</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7T5</scope><scope>7TO</scope><scope>7XB</scope><scope>8FE</scope><scope>8FH</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>H94</scope><scope>HCIFZ</scope><scope>LK8</scope><scope>M2O</scope><scope>M7P</scope><scope>MBDVC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20150730</creationdate><title>Dosimetric Characteristics of a Two-Dimensional Diode Array Detector Irradiated with Passively Scattered Proton Beams</title><author>Liengsawangwong, Praimakorn ; Sahoo, Nanayan ; Ding, Xiaoning ; Lii, MingFwu ; Gillin, Michale T ; Zhu, Xiaorong Ronald</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c418t-72440826ea439aef62d52fb0ef5532b0b1a99cecf506f9258ab9efd4f75ae0da3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Oncology</topic><topic>Radiation therapy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Liengsawangwong, Praimakorn</creatorcontrib><creatorcontrib>Sahoo, Nanayan</creatorcontrib><creatorcontrib>Ding, Xiaoning</creatorcontrib><creatorcontrib>Lii, MingFwu</creatorcontrib><creatorcontrib>Gillin, Michale T</creatorcontrib><creatorcontrib>Zhu, Xiaorong Ronald</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Immunology Abstracts</collection><collection>Oncogenes and Growth Factors Abstracts</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Biological Science Collection</collection><collection>Research Library</collection><collection>Biological Science Database</collection><collection>Research Library (Corporate)</collection><collection>Access via ProQuest (Open Access)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Cancers</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Liengsawangwong, Praimakorn</au><au>Sahoo, Nanayan</au><au>Ding, Xiaoning</au><au>Lii, MingFwu</au><au>Gillin, Michale T</au><au>Zhu, Xiaorong Ronald</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dosimetric Characteristics of a Two-Dimensional Diode Array Detector Irradiated with Passively Scattered Proton Beams</atitle><jtitle>Cancers</jtitle><addtitle>Cancers (Basel)</addtitle><date>2015-07-30</date><risdate>2015</risdate><volume>7</volume><issue>3</issue><spage>1425</spage><epage>1435</epage><pages>1425-1435</pages><issn>2072-6694</issn><eissn>2072-6694</eissn><abstract>To evaluate the dosimetric characteristics of a two-dimensional (2D) diode array detector irradiated with passively scattered proton beams.
A diode array detector, MapCHECK (Model 1175, Sun Nuclear, Melbourne, FL, USA) was characterized in passive-scattered proton beams. The relative sensitivity of the diodes and absolute dose calibration were determined using a 250 MeV beam. The pristine Bragg curves (PBCs) measured by MapCHECK diodes were compared with those of an ion chamber using a range shift method. The water-equivalent thickness (WET) of the diode array detector's intrinsic buildup also was determined. The inverse square dependence, linearity, and other proton dosimetric quantities measured by MapCHECK were also compared with those of the ion chambers. The change in the absolute dose response of the MapCHECK as a function of accumulated radiation dose was used as an indicator of radiation damage to the diodes. 2D dose distribution with and without the compensator were measured and compared with the treatment planning system (TPS) calculations.
The WET of the MapCHECK diode's buildup was determined to be 1.7 cm. The MapCHECK-measured PBC were virtually identical to those measured by a parallel-plate ion chamber for 160, 180, and 250 MeV proton beams. The inverse square results of the MapCHECK were within ±0.4% of the ion chamber results. The linearity of MapCHECK results was within 1% of those from the ion chamber as measured in the range between 10 and 300 MU. All other dosimetric quantities were within 1.3% of the ion chamber results. The 2D dose distributions for non-clinical fields without compensator and the patient treatment fields with the compensator were consistent with the TPS results. The absolute dose response of the MapCHECK was changed by 7.4% after an accumulated dose increased by 170 Gy.
The MapCHECK is a convenient and useful tool for 2D dose distribution measurements using passively scattered proton beams. Variations in MapCHECK's dose response with increasing levels of total accumulated radiation dose should be carefully monitored.</abstract><cop>Switzerland</cop><pub>MDPI AG</pub><pmid>26264024</pmid><doi>10.3390/cancers7030844</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2072-6694 |
ispartof | Cancers, 2015-07, Vol.7 (3), p.1425-1435 |
issn | 2072-6694 2072-6694 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4586777 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central Open Access; MDPI - Multidisciplinary Digital Publishing Institute; PubMed Central |
subjects | Oncology Radiation therapy |
title | Dosimetric Characteristics of a Two-Dimensional Diode Array Detector Irradiated with Passively Scattered Proton Beams |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T05%3A36%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dosimetric%20Characteristics%20of%20a%20Two-Dimensional%20Diode%20Array%20Detector%20Irradiated%20with%20Passively%20Scattered%20Proton%20Beams&rft.jtitle=Cancers&rft.au=Liengsawangwong,%20Praimakorn&rft.date=2015-07-30&rft.volume=7&rft.issue=3&rft.spage=1425&rft.epage=1435&rft.pages=1425-1435&rft.issn=2072-6694&rft.eissn=2072-6694&rft_id=info:doi/10.3390/cancers7030844&rft_dat=%3Cproquest_pubme%3E3835558051%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1721938262&rft_id=info:pmid/26264024&rfr_iscdi=true |