Endoscopic ultrasound-guided pancreatic pseudocyst cystogastrostomy using a novel self-expandable metal stent with antimigration system: A case series

Development of symptomatic pseudocysts after acute pancreatitis is a common occurrence. Endoscopic ultrasound (EUS)-guided transmural drainage has become the treatment of choice for symptomatic pseudocysts. Following this procedure, stent migration can occur. A recently developed fully covered bilia...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Endoscopic Ultrasound 2015-07, Vol.4 (3), p.229-234
Hauptverfasser: Nelsen, Eric M, Johnson, Eric A, Walker, Andrew J, Pfau, Patrick, Gopal, Deepak V
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 234
container_issue 3
container_start_page 229
container_title Endoscopic Ultrasound
container_volume 4
creator Nelsen, Eric M
Johnson, Eric A
Walker, Andrew J
Pfau, Patrick
Gopal, Deepak V
description Development of symptomatic pseudocysts after acute pancreatitis is a common occurrence. Endoscopic ultrasound (EUS)-guided transmural drainage has become the treatment of choice for symptomatic pseudocysts. Following this procedure, stent migration can occur. A recently developed fully covered biliary metal stent with antimigration system has shown promise as an alternative endoprosthetic option for cystogastrostomy. The aim of this study is to describe the success and complications of using covered metal stents with antimigration system to drain pseudocysts at a single tertiary care center. The patients undergoing cystogastrostomy using the biliary metal stent with antimigration system over the course of a 10-month period (January-November, 2014) were retrospectively reviewed and all the pertinent information including length of the follow-up, age and sex of the patient, pseudocyst size, pseudocyst size at follow-up, and symptom improvement were recorded. Five patients underwent endoscopic cystogastrostomy using a biliary metal stent with antimigration system. The average age of the patients was 57 years, with all the patients being males. The average size of the largest dimension of pseudocyst was 9 cm. The average follow-up time to repeat imaging was 30 days. All the patients had a significant improvement in their pseudocyst size, with two patients having complete resolution, one patient with a residual 2 cm cyst, and another with a residual 5 cm pseudocyst at follow-up. The average size at follow-up was 2 cm. No complications occurred during the follow-up period. No episodes of stent migration occurred. All the patients had symptom improvement at follow-up. Using a novel biliary covered self-expandable metal stent with antimigration system with EUS guidance to drain pseudocysts appears to be a safe and effective procedure in certain settings. Our experience shows rapid cyst resolution with no complications and no stent migration. This stent gives the providers another option when performing cystogastrostomy.
doi_str_mv 10.4103/2303-9027.163007
format Article
fullrecord <record><control><sourceid>gale_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4568636</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A426418887</galeid><sourcerecordid>A426418887</sourcerecordid><originalsourceid>FETCH-LOGICAL-c494t-f34604375e91b22ad2087d3f4f20dfd2fc7e38af030d7feec02889b44c4f5ac23</originalsourceid><addsrcrecordid>eNptUk1r3DAQNaWlCdvceyqCQunFW1mSLW0PhSWkHxDopT0LWRp5BbLkWnLa_SP9vZXZJGShCKRh5r3HzOhV1esGb1mD6QdCMa13mPBt01GM-bPqkhDS1bzZ4eclfihfVFcpuR4zxmkrqHhZXZCOctYKcln9vQkmJh0np9Hi86xSXIKph8UZMGhSQc-gcilOCRYT9TFltF5xUCnPsQTjES3JhQEpFOIdeJTA2xr-FK5RvQc0QlYlmyFk9NvlA1Ihu9ENc9GNAaWiBuNHtEdaJSjs2UF6Vb2wyie4un831c_PNz-uv9a33798u97f1prtWK4tZR1mlLewa3pClCFYcEMtswQba4jVHKhQFlNsuAXQmAix6xnTzLZKE7qpPp10p6UfwejS46y8nGY3qvkoo3LyvBLcQQ7xTrK2Ex3tisD7e4E5_logZTm6pMF7FSAuSTa8oS0RrHS5qd6eoIPyIF2wsSjqFS73jHSsEULwgtr-B1WOgdHpGMC6kj8jvHtCOIDy-ZCiX9blpnMgPgF1-bc0g30cs8FydZRcLSNXy8iTowrlzdP1PBIe_EP_AQljycg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1713528404</pqid></control><display><type>article</type><title>Endoscopic ultrasound-guided pancreatic pseudocyst cystogastrostomy using a novel self-expandable metal stent with antimigration system: A case series</title><source>Medknow Open Access Medical Journals</source><source>PubMed Central Open Access</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>Nelsen, Eric M ; Johnson, Eric A ; Walker, Andrew J ; Pfau, Patrick ; Gopal, Deepak V</creator><creatorcontrib>Nelsen, Eric M ; Johnson, Eric A ; Walker, Andrew J ; Pfau, Patrick ; Gopal, Deepak V</creatorcontrib><description>Development of symptomatic pseudocysts after acute pancreatitis is a common occurrence. Endoscopic ultrasound (EUS)-guided transmural drainage has become the treatment of choice for symptomatic pseudocysts. Following this procedure, stent migration can occur. A recently developed fully covered biliary metal stent with antimigration system has shown promise as an alternative endoprosthetic option for cystogastrostomy. The aim of this study is to describe the success and complications of using covered metal stents with antimigration system to drain pseudocysts at a single tertiary care center. The patients undergoing cystogastrostomy using the biliary metal stent with antimigration system over the course of a 10-month period (January-November, 2014) were retrospectively reviewed and all the pertinent information including length of the follow-up, age and sex of the patient, pseudocyst size, pseudocyst size at follow-up, and symptom improvement were recorded. Five patients underwent endoscopic cystogastrostomy using a biliary metal stent with antimigration system. The average age of the patients was 57 years, with all the patients being males. The average size of the largest dimension of pseudocyst was 9 cm. The average follow-up time to repeat imaging was 30 days. All the patients had a significant improvement in their pseudocyst size, with two patients having complete resolution, one patient with a residual 2 cm cyst, and another with a residual 5 cm pseudocyst at follow-up. The average size at follow-up was 2 cm. No complications occurred during the follow-up period. No episodes of stent migration occurred. All the patients had symptom improvement at follow-up. Using a novel biliary covered self-expandable metal stent with antimigration system with EUS guidance to drain pseudocysts appears to be a safe and effective procedure in certain settings. Our experience shows rapid cyst resolution with no complications and no stent migration. This stent gives the providers another option when performing cystogastrostomy.</description><identifier>ISSN: 2303-9027</identifier><identifier>EISSN: 2226-7190</identifier><identifier>DOI: 10.4103/2303-9027.163007</identifier><identifier>PMID: 26374582</identifier><language>eng</language><publisher>China: Medknow Publications and Media Pvt. Ltd</publisher><subject>Care and treatment ; Complications and side effects ; Cysts ; Development and progression ; Endoscopic ultrasonography ; Methods ; Original ; Pancreatitis ; Patient outcomes ; Stents</subject><ispartof>Endoscopic Ultrasound, 2015-07, Vol.4 (3), p.229-234</ispartof><rights>COPYRIGHT 2015 Medknow Publications and Media Pvt. Ltd.</rights><rights>Copyright: © Endoscopic Ultrasound 2015</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c494t-f34604375e91b22ad2087d3f4f20dfd2fc7e38af030d7feec02889b44c4f5ac23</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4568636/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4568636/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,725,778,782,883,27907,27908,53774,53776</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26374582$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nelsen, Eric M</creatorcontrib><creatorcontrib>Johnson, Eric A</creatorcontrib><creatorcontrib>Walker, Andrew J</creatorcontrib><creatorcontrib>Pfau, Patrick</creatorcontrib><creatorcontrib>Gopal, Deepak V</creatorcontrib><title>Endoscopic ultrasound-guided pancreatic pseudocyst cystogastrostomy using a novel self-expandable metal stent with antimigration system: A case series</title><title>Endoscopic Ultrasound</title><addtitle>Endosc Ultrasound</addtitle><description>Development of symptomatic pseudocysts after acute pancreatitis is a common occurrence. Endoscopic ultrasound (EUS)-guided transmural drainage has become the treatment of choice for symptomatic pseudocysts. Following this procedure, stent migration can occur. A recently developed fully covered biliary metal stent with antimigration system has shown promise as an alternative endoprosthetic option for cystogastrostomy. The aim of this study is to describe the success and complications of using covered metal stents with antimigration system to drain pseudocysts at a single tertiary care center. The patients undergoing cystogastrostomy using the biliary metal stent with antimigration system over the course of a 10-month period (January-November, 2014) were retrospectively reviewed and all the pertinent information including length of the follow-up, age and sex of the patient, pseudocyst size, pseudocyst size at follow-up, and symptom improvement were recorded. Five patients underwent endoscopic cystogastrostomy using a biliary metal stent with antimigration system. The average age of the patients was 57 years, with all the patients being males. The average size of the largest dimension of pseudocyst was 9 cm. The average follow-up time to repeat imaging was 30 days. All the patients had a significant improvement in their pseudocyst size, with two patients having complete resolution, one patient with a residual 2 cm cyst, and another with a residual 5 cm pseudocyst at follow-up. The average size at follow-up was 2 cm. No complications occurred during the follow-up period. No episodes of stent migration occurred. All the patients had symptom improvement at follow-up. Using a novel biliary covered self-expandable metal stent with antimigration system with EUS guidance to drain pseudocysts appears to be a safe and effective procedure in certain settings. Our experience shows rapid cyst resolution with no complications and no stent migration. This stent gives the providers another option when performing cystogastrostomy.</description><subject>Care and treatment</subject><subject>Complications and side effects</subject><subject>Cysts</subject><subject>Development and progression</subject><subject>Endoscopic ultrasonography</subject><subject>Methods</subject><subject>Original</subject><subject>Pancreatitis</subject><subject>Patient outcomes</subject><subject>Stents</subject><issn>2303-9027</issn><issn>2226-7190</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNptUk1r3DAQNaWlCdvceyqCQunFW1mSLW0PhSWkHxDopT0LWRp5BbLkWnLa_SP9vZXZJGShCKRh5r3HzOhV1esGb1mD6QdCMa13mPBt01GM-bPqkhDS1bzZ4eclfihfVFcpuR4zxmkrqHhZXZCOctYKcln9vQkmJh0np9Hi86xSXIKph8UZMGhSQc-gcilOCRYT9TFltF5xUCnPsQTjES3JhQEpFOIdeJTA2xr-FK5RvQc0QlYlmyFk9NvlA1Ihu9ENc9GNAaWiBuNHtEdaJSjs2UF6Vb2wyie4un831c_PNz-uv9a33798u97f1prtWK4tZR1mlLewa3pClCFYcEMtswQba4jVHKhQFlNsuAXQmAix6xnTzLZKE7qpPp10p6UfwejS46y8nGY3qvkoo3LyvBLcQQ7xTrK2Ex3tisD7e4E5_logZTm6pMF7FSAuSTa8oS0RrHS5qd6eoIPyIF2wsSjqFS73jHSsEULwgtr-B1WOgdHpGMC6kj8jvHtCOIDy-ZCiX9blpnMgPgF1-bc0g30cs8FydZRcLSNXy8iTowrlzdP1PBIe_EP_AQljycg</recordid><startdate>20150701</startdate><enddate>20150701</enddate><creator>Nelsen, Eric M</creator><creator>Johnson, Eric A</creator><creator>Walker, Andrew J</creator><creator>Pfau, Patrick</creator><creator>Gopal, Deepak V</creator><general>Medknow Publications and Media Pvt. Ltd</general><general>Medknow Publications &amp; Media Pvt Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20150701</creationdate><title>Endoscopic ultrasound-guided pancreatic pseudocyst cystogastrostomy using a novel self-expandable metal stent with antimigration system: A case series</title><author>Nelsen, Eric M ; Johnson, Eric A ; Walker, Andrew J ; Pfau, Patrick ; Gopal, Deepak V</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c494t-f34604375e91b22ad2087d3f4f20dfd2fc7e38af030d7feec02889b44c4f5ac23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Care and treatment</topic><topic>Complications and side effects</topic><topic>Cysts</topic><topic>Development and progression</topic><topic>Endoscopic ultrasonography</topic><topic>Methods</topic><topic>Original</topic><topic>Pancreatitis</topic><topic>Patient outcomes</topic><topic>Stents</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nelsen, Eric M</creatorcontrib><creatorcontrib>Johnson, Eric A</creatorcontrib><creatorcontrib>Walker, Andrew J</creatorcontrib><creatorcontrib>Pfau, Patrick</creatorcontrib><creatorcontrib>Gopal, Deepak V</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Endoscopic Ultrasound</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nelsen, Eric M</au><au>Johnson, Eric A</au><au>Walker, Andrew J</au><au>Pfau, Patrick</au><au>Gopal, Deepak V</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Endoscopic ultrasound-guided pancreatic pseudocyst cystogastrostomy using a novel self-expandable metal stent with antimigration system: A case series</atitle><jtitle>Endoscopic Ultrasound</jtitle><addtitle>Endosc Ultrasound</addtitle><date>2015-07-01</date><risdate>2015</risdate><volume>4</volume><issue>3</issue><spage>229</spage><epage>234</epage><pages>229-234</pages><issn>2303-9027</issn><eissn>2226-7190</eissn><abstract>Development of symptomatic pseudocysts after acute pancreatitis is a common occurrence. Endoscopic ultrasound (EUS)-guided transmural drainage has become the treatment of choice for symptomatic pseudocysts. Following this procedure, stent migration can occur. A recently developed fully covered biliary metal stent with antimigration system has shown promise as an alternative endoprosthetic option for cystogastrostomy. The aim of this study is to describe the success and complications of using covered metal stents with antimigration system to drain pseudocysts at a single tertiary care center. The patients undergoing cystogastrostomy using the biliary metal stent with antimigration system over the course of a 10-month period (January-November, 2014) were retrospectively reviewed and all the pertinent information including length of the follow-up, age and sex of the patient, pseudocyst size, pseudocyst size at follow-up, and symptom improvement were recorded. Five patients underwent endoscopic cystogastrostomy using a biliary metal stent with antimigration system. The average age of the patients was 57 years, with all the patients being males. The average size of the largest dimension of pseudocyst was 9 cm. The average follow-up time to repeat imaging was 30 days. All the patients had a significant improvement in their pseudocyst size, with two patients having complete resolution, one patient with a residual 2 cm cyst, and another with a residual 5 cm pseudocyst at follow-up. The average size at follow-up was 2 cm. No complications occurred during the follow-up period. No episodes of stent migration occurred. All the patients had symptom improvement at follow-up. Using a novel biliary covered self-expandable metal stent with antimigration system with EUS guidance to drain pseudocysts appears to be a safe and effective procedure in certain settings. Our experience shows rapid cyst resolution with no complications and no stent migration. This stent gives the providers another option when performing cystogastrostomy.</abstract><cop>China</cop><pub>Medknow Publications and Media Pvt. Ltd</pub><pmid>26374582</pmid><doi>10.4103/2303-9027.163007</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2303-9027
ispartof Endoscopic Ultrasound, 2015-07, Vol.4 (3), p.229-234
issn 2303-9027
2226-7190
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4568636
source Medknow Open Access Medical Journals; PubMed Central Open Access; EZB-FREE-00999 freely available EZB journals; PubMed Central
subjects Care and treatment
Complications and side effects
Cysts
Development and progression
Endoscopic ultrasonography
Methods
Original
Pancreatitis
Patient outcomes
Stents
title Endoscopic ultrasound-guided pancreatic pseudocyst cystogastrostomy using a novel self-expandable metal stent with antimigration system: A case series
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T07%3A30%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Endoscopic%20ultrasound-guided%20pancreatic%20pseudocyst%20cystogastrostomy%20using%20a%20novel%20self-expandable%20metal%20stent%20with%20antimigration%20system:%20A%20case%20series&rft.jtitle=Endoscopic%20Ultrasound&rft.au=Nelsen,%20Eric%20M&rft.date=2015-07-01&rft.volume=4&rft.issue=3&rft.spage=229&rft.epage=234&rft.pages=229-234&rft.issn=2303-9027&rft.eissn=2226-7190&rft_id=info:doi/10.4103/2303-9027.163007&rft_dat=%3Cgale_pubme%3EA426418887%3C/gale_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1713528404&rft_id=info:pmid/26374582&rft_galeid=A426418887&rfr_iscdi=true