Comparison of cannulated screws with FiberWire or stainless steel wire for patella fracture fixation: A pilot study
Abstract Purpose This pilot study tested whether FiberWire provides similar protection to steel wire against repair displacement in patella fractures. Methods Thirteen cadaver knees were cyclically loaded with 10 cycles (0–90° flexion) and fracture displacement was recorded. Fixation methods were al...
Gespeichert in:
Veröffentlicht in: | Journal of orthopaedics 2015-06, Vol.12 (2), p.92-96 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 96 |
---|---|
container_issue | 2 |
container_start_page | 92 |
container_title | Journal of orthopaedics |
container_volume | 12 |
creator | Bryant, Tony L Anderson, Christopher L Stevens, Christopher G Conrad, Bryan P Vincent, Heather K Sadasivan, Kalia K |
description | Abstract Purpose This pilot study tested whether FiberWire provides similar protection to steel wire against repair displacement in patella fractures. Methods Thirteen cadaver knees were cyclically loaded with 10 cycles (0–90° flexion) and fracture displacement was recorded. Fixation methods were also tested in load to failure (>3 mm displacement). Results There was no difference between wire types in fracture displacement (1.4 mm ± 0.33 mm vs 1.2 mm ± 0.34 mm, respectively; p = 0.418) or in the load to failure (714.7 N ± 110.9 N vs 744.5 N ± 92.8 N, respectively; p = 0.360). Conclusion FiberWire provides similar protection to steel wire against repair displacement after fixation of patellar fractures. |
doi_str_mv | 10.1016/j.jor.2014.04.011 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4421085</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S0972978X14000300</els_id><sourcerecordid>1681263232</sourcerecordid><originalsourceid>FETCH-LOGICAL-c436t-52c135158b9650569c875bf86b1e7048d0ed5fc55f1a40cfb68452dba192a2ef3</originalsourceid><addsrcrecordid>eNp9Us1u1DAQthCIloUH4IJy5LJbjxPnB6RK1YpSpEocAMHNcpwxdfDawXZa9m14Fp4MR1uqwgF5JI9m5vvGnm8IeQ50AxTqk3Ez-rBhFKoNzQbwgBzTrmHrrmm_PLznH5EnMY6UlozX5WNyxHjONJQek7T1u0kGE70rvC6UdG62MuFQRBXwJhY3Jl0V56bH8NkELHwoYpLGWYwxe4g2V-S4zokp46yVhQ5SpXkJmh8yGe9eFWe_fk7G-pQh87B_Sh5paSM-u71X5NP5m4_bi_Xl-7fvtmeXa1WVdVpzpqDkwNu-qznldafahve6rXvAhlbtQHHgWnGuQVZU6b5uK86GXkLHJENdrsjpgXea-x0OCl0K0oopmJ0Me-GlEX9nnLkSX_21qCoGtOWZ4OUtQfDfZ4xJ7ExUyycd-jkKqFtgdcnyWRE4lKrgYwyo79oAFYtaYhRZLbGoJWg2gIx5cf99d4g_8uSC14cCzFO6NhhEVAadwiHPXCUxePNf-tN_0MoaZ5S033CPcfRzcHn8AkRkgooPy7os2wIVzb2z_QaGb75b</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1681263232</pqid></control><display><type>article</type><title>Comparison of cannulated screws with FiberWire or stainless steel wire for patella fracture fixation: A pilot study</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Bryant, Tony L ; Anderson, Christopher L ; Stevens, Christopher G ; Conrad, Bryan P ; Vincent, Heather K ; Sadasivan, Kalia K</creator><creatorcontrib>Bryant, Tony L ; Anderson, Christopher L ; Stevens, Christopher G ; Conrad, Bryan P ; Vincent, Heather K ; Sadasivan, Kalia K</creatorcontrib><description>Abstract Purpose This pilot study tested whether FiberWire provides similar protection to steel wire against repair displacement in patella fractures. Methods Thirteen cadaver knees were cyclically loaded with 10 cycles (0–90° flexion) and fracture displacement was recorded. Fixation methods were also tested in load to failure (>3 mm displacement). Results There was no difference between wire types in fracture displacement (1.4 mm ± 0.33 mm vs 1.2 mm ± 0.34 mm, respectively; p = 0.418) or in the load to failure (714.7 N ± 110.9 N vs 744.5 N ± 92.8 N, respectively; p = 0.360). Conclusion FiberWire provides similar protection to steel wire against repair displacement after fixation of patellar fractures.</description><identifier>ISSN: 0972-978X</identifier><identifier>EISSN: 0972-978X</identifier><identifier>DOI: 10.1016/j.jor.2014.04.011</identifier><identifier>PMID: 25972700</identifier><language>eng</language><publisher>India: Elsevier B.V</publisher><subject>Fixation ; Fracture ; Knee ; Original ; Orthopedics ; Patella</subject><ispartof>Journal of orthopaedics, 2015-06, Vol.12 (2), p.92-96</ispartof><rights>Prof. P K Surendran Memorial Education Foundation</rights><rights>2014 Prof. P K Surendran Memorial Education Foundation</rights><rights>Copyright © 2014, Professor P K Surendran Memorial Education Foundation. Publishing Services by Reed Elsevier India Pvt. Ltd. All rights reserved. 2014 Prof. P K Surendran Memorial Education Foundation</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c436t-52c135158b9650569c875bf86b1e7048d0ed5fc55f1a40cfb68452dba192a2ef3</citedby><cites>FETCH-LOGICAL-c436t-52c135158b9650569c875bf86b1e7048d0ed5fc55f1a40cfb68452dba192a2ef3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4421085/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4421085/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27923,27924,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25972700$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bryant, Tony L</creatorcontrib><creatorcontrib>Anderson, Christopher L</creatorcontrib><creatorcontrib>Stevens, Christopher G</creatorcontrib><creatorcontrib>Conrad, Bryan P</creatorcontrib><creatorcontrib>Vincent, Heather K</creatorcontrib><creatorcontrib>Sadasivan, Kalia K</creatorcontrib><title>Comparison of cannulated screws with FiberWire or stainless steel wire for patella fracture fixation: A pilot study</title><title>Journal of orthopaedics</title><addtitle>J Orthop</addtitle><description>Abstract Purpose This pilot study tested whether FiberWire provides similar protection to steel wire against repair displacement in patella fractures. Methods Thirteen cadaver knees were cyclically loaded with 10 cycles (0–90° flexion) and fracture displacement was recorded. Fixation methods were also tested in load to failure (>3 mm displacement). Results There was no difference between wire types in fracture displacement (1.4 mm ± 0.33 mm vs 1.2 mm ± 0.34 mm, respectively; p = 0.418) or in the load to failure (714.7 N ± 110.9 N vs 744.5 N ± 92.8 N, respectively; p = 0.360). Conclusion FiberWire provides similar protection to steel wire against repair displacement after fixation of patellar fractures.</description><subject>Fixation</subject><subject>Fracture</subject><subject>Knee</subject><subject>Original</subject><subject>Orthopedics</subject><subject>Patella</subject><issn>0972-978X</issn><issn>0972-978X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNp9Us1u1DAQthCIloUH4IJy5LJbjxPnB6RK1YpSpEocAMHNcpwxdfDawXZa9m14Fp4MR1uqwgF5JI9m5vvGnm8IeQ50AxTqk3Ez-rBhFKoNzQbwgBzTrmHrrmm_PLznH5EnMY6UlozX5WNyxHjONJQek7T1u0kGE70rvC6UdG62MuFQRBXwJhY3Jl0V56bH8NkELHwoYpLGWYwxe4g2V-S4zokp46yVhQ5SpXkJmh8yGe9eFWe_fk7G-pQh87B_Sh5paSM-u71X5NP5m4_bi_Xl-7fvtmeXa1WVdVpzpqDkwNu-qznldafahve6rXvAhlbtQHHgWnGuQVZU6b5uK86GXkLHJENdrsjpgXea-x0OCl0K0oopmJ0Me-GlEX9nnLkSX_21qCoGtOWZ4OUtQfDfZ4xJ7ExUyycd-jkKqFtgdcnyWRE4lKrgYwyo79oAFYtaYhRZLbGoJWg2gIx5cf99d4g_8uSC14cCzFO6NhhEVAadwiHPXCUxePNf-tN_0MoaZ5S033CPcfRzcHn8AkRkgooPy7os2wIVzb2z_QaGb75b</recordid><startdate>20150601</startdate><enddate>20150601</enddate><creator>Bryant, Tony L</creator><creator>Anderson, Christopher L</creator><creator>Stevens, Christopher G</creator><creator>Conrad, Bryan P</creator><creator>Vincent, Heather K</creator><creator>Sadasivan, Kalia K</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20150601</creationdate><title>Comparison of cannulated screws with FiberWire or stainless steel wire for patella fracture fixation: A pilot study</title><author>Bryant, Tony L ; Anderson, Christopher L ; Stevens, Christopher G ; Conrad, Bryan P ; Vincent, Heather K ; Sadasivan, Kalia K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c436t-52c135158b9650569c875bf86b1e7048d0ed5fc55f1a40cfb68452dba192a2ef3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Fixation</topic><topic>Fracture</topic><topic>Knee</topic><topic>Original</topic><topic>Orthopedics</topic><topic>Patella</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bryant, Tony L</creatorcontrib><creatorcontrib>Anderson, Christopher L</creatorcontrib><creatorcontrib>Stevens, Christopher G</creatorcontrib><creatorcontrib>Conrad, Bryan P</creatorcontrib><creatorcontrib>Vincent, Heather K</creatorcontrib><creatorcontrib>Sadasivan, Kalia K</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of orthopaedics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bryant, Tony L</au><au>Anderson, Christopher L</au><au>Stevens, Christopher G</au><au>Conrad, Bryan P</au><au>Vincent, Heather K</au><au>Sadasivan, Kalia K</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of cannulated screws with FiberWire or stainless steel wire for patella fracture fixation: A pilot study</atitle><jtitle>Journal of orthopaedics</jtitle><addtitle>J Orthop</addtitle><date>2015-06-01</date><risdate>2015</risdate><volume>12</volume><issue>2</issue><spage>92</spage><epage>96</epage><pages>92-96</pages><issn>0972-978X</issn><eissn>0972-978X</eissn><abstract>Abstract Purpose This pilot study tested whether FiberWire provides similar protection to steel wire against repair displacement in patella fractures. Methods Thirteen cadaver knees were cyclically loaded with 10 cycles (0–90° flexion) and fracture displacement was recorded. Fixation methods were also tested in load to failure (>3 mm displacement). Results There was no difference between wire types in fracture displacement (1.4 mm ± 0.33 mm vs 1.2 mm ± 0.34 mm, respectively; p = 0.418) or in the load to failure (714.7 N ± 110.9 N vs 744.5 N ± 92.8 N, respectively; p = 0.360). Conclusion FiberWire provides similar protection to steel wire against repair displacement after fixation of patellar fractures.</abstract><cop>India</cop><pub>Elsevier B.V</pub><pmid>25972700</pmid><doi>10.1016/j.jor.2014.04.011</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0972-978X |
ispartof | Journal of orthopaedics, 2015-06, Vol.12 (2), p.92-96 |
issn | 0972-978X 0972-978X |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4421085 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central; Alma/SFX Local Collection |
subjects | Fixation Fracture Knee Original Orthopedics Patella |
title | Comparison of cannulated screws with FiberWire or stainless steel wire for patella fracture fixation: A pilot study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T02%3A23%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20cannulated%20screws%20with%20FiberWire%20or%20stainless%20steel%20wire%20for%20patella%20fracture%20fixation:%20A%C2%A0pilot%20study&rft.jtitle=Journal%20of%20orthopaedics&rft.au=Bryant,%20Tony%20L&rft.date=2015-06-01&rft.volume=12&rft.issue=2&rft.spage=92&rft.epage=96&rft.pages=92-96&rft.issn=0972-978X&rft.eissn=0972-978X&rft_id=info:doi/10.1016/j.jor.2014.04.011&rft_dat=%3Cproquest_pubme%3E1681263232%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1681263232&rft_id=info:pmid/25972700&rft_els_id=1_s2_0_S0972978X14000300&rfr_iscdi=true |