Evaluation of analytical errors in a clinical chemistry laboratory: a 3 year experience

Proficient laboratory service is the cornerstone of modern healthcare systems and has an impact on over 70% of medical decisions on admission, discharge, and medications. In recent years, there is an increasing awareness of the importance of errors in laboratory practice and their possible negative...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of medical and health sciences research 2015-01, Vol.5 (1), p.8-12
Hauptverfasser: Sakyi, As, Laing, Ef, Ephraim, Rk, Asibey, Of, Sadique, Ok
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 12
container_issue 1
container_start_page 8
container_title Annals of medical and health sciences research
container_volume 5
creator Sakyi, As
Laing, Ef
Ephraim, Rk
Asibey, Of
Sadique, Ok
description Proficient laboratory service is the cornerstone of modern healthcare systems and has an impact on over 70% of medical decisions on admission, discharge, and medications. In recent years, there is an increasing awareness of the importance of errors in laboratory practice and their possible negative impact on patient outcomes. We retrospectively analyzed data spanning a period of 3 years on analytical errors observed in our laboratory. The data covered errors over the whole testing cycle including pre-, intra-, and post-analytical phases and discussed strategies pertinent to our settings to minimize their occurrence. We described the occurrence of pre-analytical, analytical and post-analytical errors observed at the Komfo Anokye Teaching Hospital clinical biochemistry laboratory during a 3-year period from January, 2010 to December, 2012. Data were analyzed with Graph Pad Prism 5(GraphPad Software Inc. CA USA). A total of 589,510 tests was performed on 188,503 outpatients and hospitalized patients. The overall error rate for the 3 years was 4.7% (27,520/58,950). Pre-analytical, analytical and post-analytical errors contributed 3.7% (2210/58,950), 0.1% (108/58,950), and 0.9% (512/58,950), respectively. The number of tests reduced significantly over the 3-year period, but this did not correspond with a reduction in the overall error rate (P = 0.90) along with the years. Analytical errors are embedded within our total process setup especially pre-analytical and post-analytical phases. Strategic measures including quality assessment programs for staff involved in pre-analytical processes should be intensified.
doi_str_mv 10.4103/2141-9248.149763
format Article
fullrecord <record><control><sourceid>gale_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4350069</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A399212103</galeid><sourcerecordid>A399212103</sourcerecordid><originalsourceid>FETCH-LOGICAL-c393t-46bf61f50771e6ce427d310a878a870245d5604baec15f85f8743c28c7e986393</originalsourceid><addsrcrecordid>eNptUc9LXDEQDqVSxXrvqQR66WXX_M57PRRErC0IvVh6DNnsPE3JJtvkrfj--85zVSqYZEiY-b6PzHyEfOBsqTiTp4IrvuiF6pZc9dbIN-RICGsxxfRbfD-VD8lJa38YLqMVE_wdORTaKq1Nf0R-X9z5tPNjLJmWgfrs0zTG4BOFWkttNGbqaUgxPyTDLWxiG-tEk1-V6sdSpy8IkHQCXyncb6FGyAHek4PBpwYnj_cx-fXt4vr8--Lq5-WP87OrRZC9HBfKrAbDB82s5WACKGHXkjPf2Q6DCaXX2jC18hC4Hjo8VskgumCh7wxKHJOve93tbrWBdYA8Vp_ctsaNr5MrPrqXlRxv3U25c0pqHMgs8PlRoJa_O2ijwwYDpOQzlF1z3BguhcEJI_TTHnrjE7iYh4KKYYa7M9n3ggu0BVHLV1C41zi6UDIMEfMvCGxPCLW0VmF4_j1nbnbazVa62Uq3dxopH__v-pnw5Kv8BysUofo</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1661326497</pqid></control><display><type>article</type><title>Evaluation of analytical errors in a clinical chemistry laboratory: a 3 year experience</title><source>African Journals Online (Open Access)</source><source>PubMed Central</source><source>EZB Electronic Journals Library</source><source>PubMed Central Open Access</source><creator>Sakyi, As ; Laing, Ef ; Ephraim, Rk ; Asibey, Of ; Sadique, Ok</creator><creatorcontrib>Sakyi, As ; Laing, Ef ; Ephraim, Rk ; Asibey, Of ; Sadique, Ok</creatorcontrib><description>Proficient laboratory service is the cornerstone of modern healthcare systems and has an impact on over 70% of medical decisions on admission, discharge, and medications. In recent years, there is an increasing awareness of the importance of errors in laboratory practice and their possible negative impact on patient outcomes. We retrospectively analyzed data spanning a period of 3 years on analytical errors observed in our laboratory. The data covered errors over the whole testing cycle including pre-, intra-, and post-analytical phases and discussed strategies pertinent to our settings to minimize their occurrence. We described the occurrence of pre-analytical, analytical and post-analytical errors observed at the Komfo Anokye Teaching Hospital clinical biochemistry laboratory during a 3-year period from January, 2010 to December, 2012. Data were analyzed with Graph Pad Prism 5(GraphPad Software Inc. CA USA). A total of 589,510 tests was performed on 188,503 outpatients and hospitalized patients. The overall error rate for the 3 years was 4.7% (27,520/58,950). Pre-analytical, analytical and post-analytical errors contributed 3.7% (2210/58,950), 0.1% (108/58,950), and 0.9% (512/58,950), respectively. The number of tests reduced significantly over the 3-year period, but this did not correspond with a reduction in the overall error rate (P = 0.90) along with the years. Analytical errors are embedded within our total process setup especially pre-analytical and post-analytical phases. Strategic measures including quality assessment programs for staff involved in pre-analytical processes should be intensified.</description><identifier>ISSN: 2141-9248</identifier><identifier>EISSN: 2277-9205</identifier><identifier>DOI: 10.4103/2141-9248.149763</identifier><identifier>PMID: 25745569</identifier><language>eng</language><publisher>India: Medknow Publications and Media Pvt. Ltd</publisher><subject>Biomedical laboratories ; Diagnostic errors ; Evaluation ; Original ; Quality management</subject><ispartof>Annals of medical and health sciences research, 2015-01, Vol.5 (1), p.8-12</ispartof><rights>COPYRIGHT 2015 Medknow Publications and Media Pvt. Ltd.</rights><rights>Copyright: © Annals of Medical and Health Sciences Research 2015</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c393t-46bf61f50771e6ce427d310a878a870245d5604baec15f85f8743c28c7e986393</citedby><cites>FETCH-LOGICAL-c393t-46bf61f50771e6ce427d310a878a870245d5604baec15f85f8743c28c7e986393</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4350069/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4350069/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,315,728,781,785,886,4025,27925,27926,27927,53793,53795</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25745569$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sakyi, As</creatorcontrib><creatorcontrib>Laing, Ef</creatorcontrib><creatorcontrib>Ephraim, Rk</creatorcontrib><creatorcontrib>Asibey, Of</creatorcontrib><creatorcontrib>Sadique, Ok</creatorcontrib><title>Evaluation of analytical errors in a clinical chemistry laboratory: a 3 year experience</title><title>Annals of medical and health sciences research</title><addtitle>Ann Med Health Sci Res</addtitle><description>Proficient laboratory service is the cornerstone of modern healthcare systems and has an impact on over 70% of medical decisions on admission, discharge, and medications. In recent years, there is an increasing awareness of the importance of errors in laboratory practice and their possible negative impact on patient outcomes. We retrospectively analyzed data spanning a period of 3 years on analytical errors observed in our laboratory. The data covered errors over the whole testing cycle including pre-, intra-, and post-analytical phases and discussed strategies pertinent to our settings to minimize their occurrence. We described the occurrence of pre-analytical, analytical and post-analytical errors observed at the Komfo Anokye Teaching Hospital clinical biochemistry laboratory during a 3-year period from January, 2010 to December, 2012. Data were analyzed with Graph Pad Prism 5(GraphPad Software Inc. CA USA). A total of 589,510 tests was performed on 188,503 outpatients and hospitalized patients. The overall error rate for the 3 years was 4.7% (27,520/58,950). Pre-analytical, analytical and post-analytical errors contributed 3.7% (2210/58,950), 0.1% (108/58,950), and 0.9% (512/58,950), respectively. The number of tests reduced significantly over the 3-year period, but this did not correspond with a reduction in the overall error rate (P = 0.90) along with the years. Analytical errors are embedded within our total process setup especially pre-analytical and post-analytical phases. Strategic measures including quality assessment programs for staff involved in pre-analytical processes should be intensified.</description><subject>Biomedical laboratories</subject><subject>Diagnostic errors</subject><subject>Evaluation</subject><subject>Original</subject><subject>Quality management</subject><issn>2141-9248</issn><issn>2277-9205</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNptUc9LXDEQDqVSxXrvqQR66WXX_M57PRRErC0IvVh6DNnsPE3JJtvkrfj--85zVSqYZEiY-b6PzHyEfOBsqTiTp4IrvuiF6pZc9dbIN-RICGsxxfRbfD-VD8lJa38YLqMVE_wdORTaKq1Nf0R-X9z5tPNjLJmWgfrs0zTG4BOFWkttNGbqaUgxPyTDLWxiG-tEk1-V6sdSpy8IkHQCXyncb6FGyAHek4PBpwYnj_cx-fXt4vr8--Lq5-WP87OrRZC9HBfKrAbDB82s5WACKGHXkjPf2Q6DCaXX2jC18hC4Hjo8VskgumCh7wxKHJOve93tbrWBdYA8Vp_ctsaNr5MrPrqXlRxv3U25c0pqHMgs8PlRoJa_O2ijwwYDpOQzlF1z3BguhcEJI_TTHnrjE7iYh4KKYYa7M9n3ggu0BVHLV1C41zi6UDIMEfMvCGxPCLW0VmF4_j1nbnbazVa62Uq3dxopH__v-pnw5Kv8BysUofo</recordid><startdate>201501</startdate><enddate>201501</enddate><creator>Sakyi, As</creator><creator>Laing, Ef</creator><creator>Ephraim, Rk</creator><creator>Asibey, Of</creator><creator>Sadique, Ok</creator><general>Medknow Publications and Media Pvt. Ltd</general><general>Medknow Publications &amp; Media Pvt Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>201501</creationdate><title>Evaluation of analytical errors in a clinical chemistry laboratory: a 3 year experience</title><author>Sakyi, As ; Laing, Ef ; Ephraim, Rk ; Asibey, Of ; Sadique, Ok</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c393t-46bf61f50771e6ce427d310a878a870245d5604baec15f85f8743c28c7e986393</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Biomedical laboratories</topic><topic>Diagnostic errors</topic><topic>Evaluation</topic><topic>Original</topic><topic>Quality management</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sakyi, As</creatorcontrib><creatorcontrib>Laing, Ef</creatorcontrib><creatorcontrib>Ephraim, Rk</creatorcontrib><creatorcontrib>Asibey, Of</creatorcontrib><creatorcontrib>Sadique, Ok</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Annals of medical and health sciences research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sakyi, As</au><au>Laing, Ef</au><au>Ephraim, Rk</au><au>Asibey, Of</au><au>Sadique, Ok</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of analytical errors in a clinical chemistry laboratory: a 3 year experience</atitle><jtitle>Annals of medical and health sciences research</jtitle><addtitle>Ann Med Health Sci Res</addtitle><date>2015-01</date><risdate>2015</risdate><volume>5</volume><issue>1</issue><spage>8</spage><epage>12</epage><pages>8-12</pages><issn>2141-9248</issn><eissn>2277-9205</eissn><abstract>Proficient laboratory service is the cornerstone of modern healthcare systems and has an impact on over 70% of medical decisions on admission, discharge, and medications. In recent years, there is an increasing awareness of the importance of errors in laboratory practice and their possible negative impact on patient outcomes. We retrospectively analyzed data spanning a period of 3 years on analytical errors observed in our laboratory. The data covered errors over the whole testing cycle including pre-, intra-, and post-analytical phases and discussed strategies pertinent to our settings to minimize their occurrence. We described the occurrence of pre-analytical, analytical and post-analytical errors observed at the Komfo Anokye Teaching Hospital clinical biochemistry laboratory during a 3-year period from January, 2010 to December, 2012. Data were analyzed with Graph Pad Prism 5(GraphPad Software Inc. CA USA). A total of 589,510 tests was performed on 188,503 outpatients and hospitalized patients. The overall error rate for the 3 years was 4.7% (27,520/58,950). Pre-analytical, analytical and post-analytical errors contributed 3.7% (2210/58,950), 0.1% (108/58,950), and 0.9% (512/58,950), respectively. The number of tests reduced significantly over the 3-year period, but this did not correspond with a reduction in the overall error rate (P = 0.90) along with the years. Analytical errors are embedded within our total process setup especially pre-analytical and post-analytical phases. Strategic measures including quality assessment programs for staff involved in pre-analytical processes should be intensified.</abstract><cop>India</cop><pub>Medknow Publications and Media Pvt. Ltd</pub><pmid>25745569</pmid><doi>10.4103/2141-9248.149763</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2141-9248
ispartof Annals of medical and health sciences research, 2015-01, Vol.5 (1), p.8-12
issn 2141-9248
2277-9205
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4350069
source African Journals Online (Open Access); PubMed Central; EZB Electronic Journals Library; PubMed Central Open Access
subjects Biomedical laboratories
Diagnostic errors
Evaluation
Original
Quality management
title Evaluation of analytical errors in a clinical chemistry laboratory: a 3 year experience
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-17T23%3A20%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20analytical%20errors%20in%20a%20clinical%20chemistry%20laboratory:%20a%203%20year%20experience&rft.jtitle=Annals%20of%20medical%20and%20health%20sciences%20research&rft.au=Sakyi,%20As&rft.date=2015-01&rft.volume=5&rft.issue=1&rft.spage=8&rft.epage=12&rft.pages=8-12&rft.issn=2141-9248&rft.eissn=2277-9205&rft_id=info:doi/10.4103/2141-9248.149763&rft_dat=%3Cgale_pubme%3EA399212103%3C/gale_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1661326497&rft_id=info:pmid/25745569&rft_galeid=A399212103&rfr_iscdi=true