Single- and Multiple- Track Location Shear Wave and Acoustic Radiation Force Impulse Imaging: Matched Comparison of Contrast, CNR, and Resolution

Acoustic radiation force impulse (ARFI) imaging and shear wave elasticity imaging (SWEI) use the dynamic response of tissue to impulsive mechanical stimulus to characterize local elasticity. A variant of conventional, multiple track location SWEI (MTL-SWEI), denoted single track location SWEI (STL-S...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ultrasound in medicine & biology 2015-02, Vol.41 (4), p.1043-1057
Hauptverfasser: Hollender, Peter J., Rosenzweig, Stephen J., Nightingale, Kathryn R., Trahey, Gregg E.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1057
container_issue 4
container_start_page 1043
container_title Ultrasound in medicine & biology
container_volume 41
creator Hollender, Peter J.
Rosenzweig, Stephen J.
Nightingale, Kathryn R.
Trahey, Gregg E.
description Acoustic radiation force impulse (ARFI) imaging and shear wave elasticity imaging (SWEI) use the dynamic response of tissue to impulsive mechanical stimulus to characterize local elasticity. A variant of conventional, multiple track location SWEI (MTL-SWEI), denoted single track location SWEI (STL-SWEI) offers the promise of creating speckle-free shear wave images. This work compares the three imaging modalities using a high push and track beam density combined acquisition sequence to image inclusions of different sizes and contrasts. STL-SWEI is shown to have significantly higher CNR than MTL-SWEI, allowing for operation at higher resolution. ARFI and STL-SWEI perform similarly in the larger inclusions, with STL-SWEI providing better visualization of small targets ≤2.5 mm in diameter. The processing of each modality introduces different trade-offs between smoothness and resolution of edges and structures; these are discussed in detail.
doi_str_mv 10.1016/j.ultrasmedbio.2014.11.006
format Article
fullrecord <record><control><sourceid>pubmedcentral</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4346467</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>pubmedcentral_primary_oai_pubmedcentral_nih_gov_4346467</sourcerecordid><originalsourceid>FETCH-pubmedcentral_primary_oai_pubmedcentral_nih_gov_43464673</originalsourceid><addsrcrecordid>eNqlj8tOwzAQRS0EouHxDxbrJth5OIQFEopagURZpJVgF00dN3FJ4sh2KvEZ_DFOYcOa1dXVnDmaQeiGkoASym73wdhaDaYT1VaqICQ0DigNCGEnyKN3aeaHGX0_RR6JCPUTFmYzdGHMnhCSsig9R7MwSQlNIuqhr7Xs61b4GPoKr5xXDlPbaOAf-EVxsFL1eN0I0PgNDuLIPXI1Gis5LqCSP8RSaS7wczeMrZkSaue9xyuwvBEVzlU3gJbGkWrnWj_db-c4fy3mR2UhjGrHSXWFznbgJNe_eYkelotN_uQP49Z9zMW025aDlh3oz1KBLP9OetmUtTqUcRSzmKXRvwXfysZ5CQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Single- and Multiple- Track Location Shear Wave and Acoustic Radiation Force Impulse Imaging: Matched Comparison of Contrast, CNR, and Resolution</title><source>Access via ScienceDirect (Elsevier)</source><creator>Hollender, Peter J. ; Rosenzweig, Stephen J. ; Nightingale, Kathryn R. ; Trahey, Gregg E.</creator><creatorcontrib>Hollender, Peter J. ; Rosenzweig, Stephen J. ; Nightingale, Kathryn R. ; Trahey, Gregg E.</creatorcontrib><description>Acoustic radiation force impulse (ARFI) imaging and shear wave elasticity imaging (SWEI) use the dynamic response of tissue to impulsive mechanical stimulus to characterize local elasticity. A variant of conventional, multiple track location SWEI (MTL-SWEI), denoted single track location SWEI (STL-SWEI) offers the promise of creating speckle-free shear wave images. This work compares the three imaging modalities using a high push and track beam density combined acquisition sequence to image inclusions of different sizes and contrasts. STL-SWEI is shown to have significantly higher CNR than MTL-SWEI, allowing for operation at higher resolution. ARFI and STL-SWEI perform similarly in the larger inclusions, with STL-SWEI providing better visualization of small targets ≤2.5 mm in diameter. The processing of each modality introduces different trade-offs between smoothness and resolution of edges and structures; these are discussed in detail.</description><identifier>ISSN: 0301-5629</identifier><identifier>EISSN: 1879-291X</identifier><identifier>DOI: 10.1016/j.ultrasmedbio.2014.11.006</identifier><identifier>PMID: 25701531</identifier><language>eng</language><ispartof>Ultrasound in medicine &amp; biology, 2015-02, Vol.41 (4), p.1043-1057</ispartof><rights>2014 World Federation for Ultrasound in Medicine amp; Biology. All rights reserved. 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,315,782,786,887,27931,27932</link.rule.ids></links><search><creatorcontrib>Hollender, Peter J.</creatorcontrib><creatorcontrib>Rosenzweig, Stephen J.</creatorcontrib><creatorcontrib>Nightingale, Kathryn R.</creatorcontrib><creatorcontrib>Trahey, Gregg E.</creatorcontrib><title>Single- and Multiple- Track Location Shear Wave and Acoustic Radiation Force Impulse Imaging: Matched Comparison of Contrast, CNR, and Resolution</title><title>Ultrasound in medicine &amp; biology</title><description>Acoustic radiation force impulse (ARFI) imaging and shear wave elasticity imaging (SWEI) use the dynamic response of tissue to impulsive mechanical stimulus to characterize local elasticity. A variant of conventional, multiple track location SWEI (MTL-SWEI), denoted single track location SWEI (STL-SWEI) offers the promise of creating speckle-free shear wave images. This work compares the three imaging modalities using a high push and track beam density combined acquisition sequence to image inclusions of different sizes and contrasts. STL-SWEI is shown to have significantly higher CNR than MTL-SWEI, allowing for operation at higher resolution. ARFI and STL-SWEI perform similarly in the larger inclusions, with STL-SWEI providing better visualization of small targets ≤2.5 mm in diameter. The processing of each modality introduces different trade-offs between smoothness and resolution of edges and structures; these are discussed in detail.</description><issn>0301-5629</issn><issn>1879-291X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNqlj8tOwzAQRS0EouHxDxbrJth5OIQFEopagURZpJVgF00dN3FJ4sh2KvEZ_DFOYcOa1dXVnDmaQeiGkoASym73wdhaDaYT1VaqICQ0DigNCGEnyKN3aeaHGX0_RR6JCPUTFmYzdGHMnhCSsig9R7MwSQlNIuqhr7Xs61b4GPoKr5xXDlPbaOAf-EVxsFL1eN0I0PgNDuLIPXI1Gis5LqCSP8RSaS7wczeMrZkSaue9xyuwvBEVzlU3gJbGkWrnWj_db-c4fy3mR2UhjGrHSXWFznbgJNe_eYkelotN_uQP49Z9zMW025aDlh3oz1KBLP9OetmUtTqUcRSzmKXRvwXfysZ5CQ</recordid><startdate>20150217</startdate><enddate>20150217</enddate><creator>Hollender, Peter J.</creator><creator>Rosenzweig, Stephen J.</creator><creator>Nightingale, Kathryn R.</creator><creator>Trahey, Gregg E.</creator><scope>5PM</scope></search><sort><creationdate>20150217</creationdate><title>Single- and Multiple- Track Location Shear Wave and Acoustic Radiation Force Impulse Imaging: Matched Comparison of Contrast, CNR, and Resolution</title><author>Hollender, Peter J. ; Rosenzweig, Stephen J. ; Nightingale, Kathryn R. ; Trahey, Gregg E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-pubmedcentral_primary_oai_pubmedcentral_nih_gov_43464673</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hollender, Peter J.</creatorcontrib><creatorcontrib>Rosenzweig, Stephen J.</creatorcontrib><creatorcontrib>Nightingale, Kathryn R.</creatorcontrib><creatorcontrib>Trahey, Gregg E.</creatorcontrib><collection>PubMed Central (Full Participant titles)</collection><jtitle>Ultrasound in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hollender, Peter J.</au><au>Rosenzweig, Stephen J.</au><au>Nightingale, Kathryn R.</au><au>Trahey, Gregg E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Single- and Multiple- Track Location Shear Wave and Acoustic Radiation Force Impulse Imaging: Matched Comparison of Contrast, CNR, and Resolution</atitle><jtitle>Ultrasound in medicine &amp; biology</jtitle><date>2015-02-17</date><risdate>2015</risdate><volume>41</volume><issue>4</issue><spage>1043</spage><epage>1057</epage><pages>1043-1057</pages><issn>0301-5629</issn><eissn>1879-291X</eissn><abstract>Acoustic radiation force impulse (ARFI) imaging and shear wave elasticity imaging (SWEI) use the dynamic response of tissue to impulsive mechanical stimulus to characterize local elasticity. A variant of conventional, multiple track location SWEI (MTL-SWEI), denoted single track location SWEI (STL-SWEI) offers the promise of creating speckle-free shear wave images. This work compares the three imaging modalities using a high push and track beam density combined acquisition sequence to image inclusions of different sizes and contrasts. STL-SWEI is shown to have significantly higher CNR than MTL-SWEI, allowing for operation at higher resolution. ARFI and STL-SWEI perform similarly in the larger inclusions, with STL-SWEI providing better visualization of small targets ≤2.5 mm in diameter. The processing of each modality introduces different trade-offs between smoothness and resolution of edges and structures; these are discussed in detail.</abstract><pmid>25701531</pmid><doi>10.1016/j.ultrasmedbio.2014.11.006</doi></addata></record>
fulltext fulltext
identifier ISSN: 0301-5629
ispartof Ultrasound in medicine & biology, 2015-02, Vol.41 (4), p.1043-1057
issn 0301-5629
1879-291X
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4346467
source Access via ScienceDirect (Elsevier)
title Single- and Multiple- Track Location Shear Wave and Acoustic Radiation Force Impulse Imaging: Matched Comparison of Contrast, CNR, and Resolution
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T18%3A09%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmedcentral&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Single-%20and%20Multiple-%20Track%20Location%20Shear%20Wave%20and%20Acoustic%20Radiation%20Force%20Impulse%20Imaging:%20Matched%20Comparison%20of%20Contrast,%20CNR,%20and%20Resolution&rft.jtitle=Ultrasound%20in%20medicine%20&%20biology&rft.au=Hollender,%20Peter%20J.&rft.date=2015-02-17&rft.volume=41&rft.issue=4&rft.spage=1043&rft.epage=1057&rft.pages=1043-1057&rft.issn=0301-5629&rft.eissn=1879-291X&rft_id=info:doi/10.1016/j.ultrasmedbio.2014.11.006&rft_dat=%3Cpubmedcentral%3Epubmedcentral_primary_oai_pubmedcentral_nih_gov_4346467%3C/pubmedcentral%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/25701531&rfr_iscdi=true