Comparative stress analysis of delayed and immediate loading of a single implant in an edentulous maxilla model
Stress distribution in peri-implant bone in an edentulous maxilla following delayed and immediate loading implant and the effect of implant length on the maximum stress were evaluated by using two kinds of finite element analyses. A threaded implant was loaded with a 100 N vertical force, either imm...
Gespeichert in:
Veröffentlicht in: | Journal of dental biomechanics 2014-05, Vol.5, p.1758736014533982-1758736014533982 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1758736014533982 |
---|---|
container_issue | |
container_start_page | 1758736014533982 |
container_title | Journal of dental biomechanics |
container_volume | 5 |
creator | Gao, Jie Matsushita, Yasuyuki Esaki, Daisuke Matsuzaki, Tatsuya Koyano, Kiyoshi |
description | Stress distribution in peri-implant bone in an edentulous maxilla following delayed and immediate loading implant and the effect of implant length on the maximum stress were evaluated by using two kinds of finite element analyses. A threaded implant was loaded with a 100 N vertical force, either immediately or delayed, and examined by finite element analysis with a simple contact relation or a bonding interaction between the implant and the bone, respectively. Higher stresses were observed in cortical bone around the implant neck following delayed loading and in the trabecular bone around the implant threading in the immediate loading model. The maximum stress in the immediate loading model was dramatically higher than in delayed loading. Increased implant length caused decrease in bone stresses in both loading models. Though the stress level was higher, the decrease in the maximum trabecular bone stress in immediate loading was profound. |
doi_str_mv | 10.1177/1758736014533982 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4206692</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1758736014533982</sage_id><sourcerecordid>1616480296</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4152-ca2b3dd378c692294765963c2e343be2fe8b4488518767920614fea8fd890eac3</originalsourceid><addsrcrecordid>eNp1UU1r3DAQFaWlCdvceyo65uJGX7blSyEs_QgEcmnPYtYabxVkayvZIfvvM8umIQlEFw1v3rx5w2PssxRfpWzbC9nWttWNkKbWurPqHTs9QNUBe_-sPmFnpdwKelp1WqiP7ETV2igaOWVpncYdZJjDHfIyZyyFwwRxX0LhaeAeI-zRE-Z5GEf0AWbkMYEP0_ZAAF6oikjdXYRp5mEiMkeP07zEtBQ-wn2IEfiYSOwT-zBALHj2-K_Ynx_ff69_Vdc3P6_Wl9dVb2Stqh7URnuvW9s3nVKdaZu6a3SvUBu9QTWg3RhjbS1t27SdEo00A4IdvO0EQq9X7NtRd7dsyHVPbjJEt8thhLx3CYJ72ZnCX7dNd86QFq0kgfNHgZz-LVhmN4bSIx0yIV3lZCMbY4UiVysmjtQ-p1IyDk9rpHCHqNzrqGjky3N7TwP_gyFCdSQU2KK7TUumUMrbgg8315z4</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1616480296</pqid></control><display><type>article</type><title>Comparative stress analysis of delayed and immediate loading of a single implant in an edentulous maxilla model</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central Open Access</source><source>CLOCKSS</source><source>Portico (Triggered Content) Open Access</source><source>PubMed Central</source><creator>Gao, Jie ; Matsushita, Yasuyuki ; Esaki, Daisuke ; Matsuzaki, Tatsuya ; Koyano, Kiyoshi</creator><creatorcontrib>Gao, Jie ; Matsushita, Yasuyuki ; Esaki, Daisuke ; Matsuzaki, Tatsuya ; Koyano, Kiyoshi</creatorcontrib><description>Stress distribution in peri-implant bone in an edentulous maxilla following delayed and immediate loading implant and the effect of implant length on the maximum stress were evaluated by using two kinds of finite element analyses. A threaded implant was loaded with a 100 N vertical force, either immediately or delayed, and examined by finite element analysis with a simple contact relation or a bonding interaction between the implant and the bone, respectively. Higher stresses were observed in cortical bone around the implant neck following delayed loading and in the trabecular bone around the implant threading in the immediate loading model. The maximum stress in the immediate loading model was dramatically higher than in delayed loading. Increased implant length caused decrease in bone stresses in both loading models. Though the stress level was higher, the decrease in the maximum trabecular bone stress in immediate loading was profound.</description><identifier>ISSN: 1758-7360</identifier><identifier>EISSN: 1758-7360</identifier><identifier>DOI: 10.1177/1758736014533982</identifier><identifier>PMID: 25342982</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Original</subject><ispartof>Journal of dental biomechanics, 2014-05, Vol.5, p.1758736014533982-1758736014533982</ispartof><rights>The Author(s) 2014</rights><rights>The Author(s) 2014 2014 SAGE Publications</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4152-ca2b3dd378c692294765963c2e343be2fe8b4488518767920614fea8fd890eac3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4206692/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4206692/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,27903,27904,53769,53771</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25342982$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gao, Jie</creatorcontrib><creatorcontrib>Matsushita, Yasuyuki</creatorcontrib><creatorcontrib>Esaki, Daisuke</creatorcontrib><creatorcontrib>Matsuzaki, Tatsuya</creatorcontrib><creatorcontrib>Koyano, Kiyoshi</creatorcontrib><title>Comparative stress analysis of delayed and immediate loading of a single implant in an edentulous maxilla model</title><title>Journal of dental biomechanics</title><addtitle>J Dent Biomech</addtitle><description>Stress distribution in peri-implant bone in an edentulous maxilla following delayed and immediate loading implant and the effect of implant length on the maximum stress were evaluated by using two kinds of finite element analyses. A threaded implant was loaded with a 100 N vertical force, either immediately or delayed, and examined by finite element analysis with a simple contact relation or a bonding interaction between the implant and the bone, respectively. Higher stresses were observed in cortical bone around the implant neck following delayed loading and in the trabecular bone around the implant threading in the immediate loading model. The maximum stress in the immediate loading model was dramatically higher than in delayed loading. Increased implant length caused decrease in bone stresses in both loading models. Though the stress level was higher, the decrease in the maximum trabecular bone stress in immediate loading was profound.</description><subject>Original</subject><issn>1758-7360</issn><issn>1758-7360</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNp1UU1r3DAQFaWlCdvceyo65uJGX7blSyEs_QgEcmnPYtYabxVkayvZIfvvM8umIQlEFw1v3rx5w2PssxRfpWzbC9nWttWNkKbWurPqHTs9QNUBe_-sPmFnpdwKelp1WqiP7ETV2igaOWVpncYdZJjDHfIyZyyFwwRxX0LhaeAeI-zRE-Z5GEf0AWbkMYEP0_ZAAF6oikjdXYRp5mEiMkeP07zEtBQ-wn2IEfiYSOwT-zBALHj2-K_Ynx_ff69_Vdc3P6_Wl9dVb2Stqh7URnuvW9s3nVKdaZu6a3SvUBu9QTWg3RhjbS1t27SdEo00A4IdvO0EQq9X7NtRd7dsyHVPbjJEt8thhLx3CYJ72ZnCX7dNd86QFq0kgfNHgZz-LVhmN4bSIx0yIV3lZCMbY4UiVysmjtQ-p1IyDk9rpHCHqNzrqGjky3N7TwP_gyFCdSQU2KK7TUumUMrbgg8315z4</recordid><startdate>20140514</startdate><enddate>20140514</enddate><creator>Gao, Jie</creator><creator>Matsushita, Yasuyuki</creator><creator>Esaki, Daisuke</creator><creator>Matsuzaki, Tatsuya</creator><creator>Koyano, Kiyoshi</creator><general>SAGE Publications</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20140514</creationdate><title>Comparative stress analysis of delayed and immediate loading of a single implant in an edentulous maxilla model</title><author>Gao, Jie ; Matsushita, Yasuyuki ; Esaki, Daisuke ; Matsuzaki, Tatsuya ; Koyano, Kiyoshi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4152-ca2b3dd378c692294765963c2e343be2fe8b4488518767920614fea8fd890eac3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Original</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gao, Jie</creatorcontrib><creatorcontrib>Matsushita, Yasuyuki</creatorcontrib><creatorcontrib>Esaki, Daisuke</creatorcontrib><creatorcontrib>Matsuzaki, Tatsuya</creatorcontrib><creatorcontrib>Koyano, Kiyoshi</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of dental biomechanics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gao, Jie</au><au>Matsushita, Yasuyuki</au><au>Esaki, Daisuke</au><au>Matsuzaki, Tatsuya</au><au>Koyano, Kiyoshi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparative stress analysis of delayed and immediate loading of a single implant in an edentulous maxilla model</atitle><jtitle>Journal of dental biomechanics</jtitle><addtitle>J Dent Biomech</addtitle><date>2014-05-14</date><risdate>2014</risdate><volume>5</volume><spage>1758736014533982</spage><epage>1758736014533982</epage><pages>1758736014533982-1758736014533982</pages><issn>1758-7360</issn><eissn>1758-7360</eissn><abstract>Stress distribution in peri-implant bone in an edentulous maxilla following delayed and immediate loading implant and the effect of implant length on the maximum stress were evaluated by using two kinds of finite element analyses. A threaded implant was loaded with a 100 N vertical force, either immediately or delayed, and examined by finite element analysis with a simple contact relation or a bonding interaction between the implant and the bone, respectively. Higher stresses were observed in cortical bone around the implant neck following delayed loading and in the trabecular bone around the implant threading in the immediate loading model. The maximum stress in the immediate loading model was dramatically higher than in delayed loading. Increased implant length caused decrease in bone stresses in both loading models. Though the stress level was higher, the decrease in the maximum trabecular bone stress in immediate loading was profound.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>25342982</pmid><doi>10.1177/1758736014533982</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1758-7360 |
ispartof | Journal of dental biomechanics, 2014-05, Vol.5, p.1758736014533982-1758736014533982 |
issn | 1758-7360 1758-7360 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4206692 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central Open Access; CLOCKSS; Portico (Triggered Content) Open Access; PubMed Central |
subjects | Original |
title | Comparative stress analysis of delayed and immediate loading of a single implant in an edentulous maxilla model |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T04%3A24%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparative%20stress%20analysis%20of%20delayed%20and%20immediate%20loading%20of%20a%20single%20implant%20in%20an%20edentulous%20maxilla%20model&rft.jtitle=Journal%20of%20dental%20biomechanics&rft.au=Gao,%20Jie&rft.date=2014-05-14&rft.volume=5&rft.spage=1758736014533982&rft.epage=1758736014533982&rft.pages=1758736014533982-1758736014533982&rft.issn=1758-7360&rft.eissn=1758-7360&rft_id=info:doi/10.1177/1758736014533982&rft_dat=%3Cproquest_pubme%3E1616480296%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1616480296&rft_id=info:pmid/25342982&rft_sage_id=10.1177_1758736014533982&rfr_iscdi=true |